Extractive continuous process gas analysis Series 6 OXYMAT 64

Similar documents
Continuous Gas Analyzers, extractive OXYMAT 64

Continuous Gas Analyzers, extractive

Extractive continuous process gas analysis Series 6 OXYMAT 61

1 Overview. Continuous Gas Analyzers, extractive CALOMAT 6. 1/148 Siemens AP US Edition. General information

Continuous Gas Analyzers, extractive OXYMAT 61

1 Overview. Extractive continuous process gas analysis Series 6 ULTRAMAT 6. General information

1 Overview. Continuous Gas Analyzers, extractive ULTRAMAT 6. General information

1 Overview. Extractive continuous process gas analysis Series 6 FIDAMAT 6. General information

ULTRAMAT 6. General information 2/29

1 Overview. Continuous Gas Analyzers, extractive FIDAMAT 6. General information

Continuous Gas Analyzers, extractive

1 Overview. Continuous Gas Analyzers, extractive OXYMAT 6. 1/98 Siemens AP US Edition. General information

Continuous Gas Analyzers, extractive

OXYMAT 6. General information 1/117

Extractive continuous process gas analysis Series 6 ULTRAMAT/OXYMAT 6

1 Overview ULTRAMAT/OXYMAT 6. General information

Continuous Gas Analyzers, extractive

ULTRAMAT/OXYMAT 6. General information 2/71

OXYMAT 64. Gas analyzer for measurements of trace oxygen 7MB2041. Operating Instructions June Continuous gas analysis

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive SIPROCESS GA700

1 General information Device description Scope Task definition Explosion protection, Device variants...

ULTRAMAT 6 NDIR Gas Analyzers, Singlechannel or Dual-channel Versions

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

1 Overview ULTRAMAT 23. General information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

FTC130 Transmitter. Operating Manual

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Continuous Gas Analyzers, extractive ULTRAMAT 23

LFE OEM TCD - Thermal Conductivity Detector

Continuous Gas Analyzers, extractive

Pressure transmitter PASCAL Ci4

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pressure Measurement Single-range transmitters for general applications

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Supplementary Operator s Manual 42/24-14 EN Rev. 3

SITRANS P measuring instruments for pressure

Gas density monitor With integrated transmitter Model GDM-100-TI

Continuous Gas Analyzers, extractive

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

OXYMAT 6 Gas Analyzers for the Determination of Oxygen

Transmitter CS 21 Operation Manual

Pneumatic high-pressure controller Model CPC7000

High-performance submersible pressure transmitter For level measurement Model LH-20

Mass Flow Controller (MFC) for Gases

Extractive continuous process gas analysis ULTRAMAT 23

Columbus Instruments

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Pneumatic high-pressure controller Model CPC7000

Installation and Operation Manual

Continuous Gas Analyzers, extractive

Continuous Gas Analyzer, extractive

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

High-performance submersible pressure transmitter For level measurement Model LH-10

EasyLine Continuous Gas Analyzers. So smart, they re simple

High-performance submersible pressure transmitter For level measurement Model LH-10

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

C-Flow Coriolis Mass Flow Meters

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

FIDAMAT 5E-ANM, -ANM-P gas analyzers for Measurement of Total Hydrocarbon Content 7MB , -6.. Instruction Manual

780S Ultra High Purity Series

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Technical Data Sheet MF010-O-LC

Mass Flow Meter (MFM) for gases

Transmitter CS 21 Operation Manual

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Mass Flow Meter (MFM) for Gases

2/2-Way Proportional Valve (motor-driven)

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

FIDAMAT 5E gas analyzer for Measurement of Total Hydrocarbon Content 7MB1420 Instruction Manual

SonoMeter 30 Energy Meters

GasSense NDIR User Manual

Mass Flow Controller (MFC) for Gases

EasyLine EL3000 Series Continuous Gas Analyzers Models EL3020, EL3040

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Data Sheet 10/ EN July 2007

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

High-performance submersible pressure transmitter For level measurement Model LH-20

EPP4 Pressure Regulator Basic G 1/4"

Continuous Gas Analysis ULTRAMAT 23 Supplement 1 for Operating Instructions C79000-G52xx-C Product Information

Pressure Measurement Single-range transmitters for general applications

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Hand-held pressure calibrator with integrated pump Model CPH6600

Transcription:

Overview Siemens AG 208 Extractive continuous process gas analysis General information Design 9" rack unit with HU for installation - In hinged frame - In cabinets with or without telescope rails Front plate can be swung down for servicing purposes (laptop connection) Connections for sample gas - Input: Clamping ring connection for a pipe diameter of 6 mm or ¼" - Output: Pipe connection with diameter 6 mm or ¼" High-pressure and low-pressure versions Catalytically active and inactive cell The gas analyzer is used for the trace measurement of oxygen. Benefits High linearity Compact design Open interface architecture (RS 85, RS 232, PROFIBUS) SIPROM GA network for maintenance and service information (option) Application Production of technical gases Measurements in N 2 and CO 2 Welding Measurements in protective gases during welding of highly alloyed steels, titanium, etc. Systems for air separation Measurements in N 2 and in inert gases (e.g. Ne, Ar) Measurements in CO 2 Food production Measurement in CO 2 (e.g. breweries) Electronics industry Low-pressure version with pump Flow soldering systems Display and control panel Large LCD field for simultaneous display of - Measured value -Status bar - Measuring ranges Contrast of the LCD field adjustable via the menu Permanent LED backlighting Washable membrane keyboard with five softkeys Five-digit measured-value display (decimal point counts as one digit) Menu-driven operation for parameterization, configuration, test functions, adjustment User help in plain text Graphic display of concentration trend; programmable time intervals Bilingual operating software German/English, English/ Spanish, French/English, Spanish/English, Italian/English Switchover from ppm/vpm measuring range to % measuring range Input and outputs One analog output per medium (from 0, 2, to 20 ma; NAMUR parameterizable) Six digital inputs freely configurable (e.g. for measurement range switchover, processing of external signals from sample preparation) Six relay outputs freely configurable (failure, maintenance demanded, maintenance switch, threshold alarm, external magnetic valves) Two analog inputs configurable (e.g. correction of cross-interference, external pressure sensor) Expansion by eight additional digital inputs and eight additional relay outputs for autocalibration with up to four calibration gases Communication RS 85 present in basic unit (connection from the rear). Options RS 85/RS 232 converter RS 85/Ethernet converter RS 85/USB converter Connection to networks via PROFIBUS DP/PA interface SIPROM GA software as the service and maintenance tool Siemens AP 0 208 /3

Extractive continuous process gas analysis Siemens AG 208 General information LED backlit graphic display and membrane keyboard with noticeable click Status line to display the analyzer status (programmable) Two code levels according to NAMUR (maintenance and specialist level) Easy operation menu controlusing the softkeys Display of concentrations as numbers and bargraph Display of start-of-scale and full-scale values Display of current measuring ranges Keyboard to enter values ESC key to abort inputs INFO key for help in plain text CLEAR key to delete inputs ENTER key to accept input values MEAS key to return to measurement mode, membrane keyboard and graphic display Designs Parts wetted by sample gas, standard Gas path Sample gas path Pressure sensor Flow indicator Pressure switch Bushing Pipe inlet O 2 sensor Bypass line Connection pieces Enclosure Membrane Sensor adapter Bypass restrictor Measurement pipe Variable area Suspension boundary Angle pieces Enclosure Diaphragm 9" rack unit Stainless steel, mat. no..57 Stainless steel ZrO 2 ceramic FPM (Viton) PTFE (Teflon) Polycarbonate SiO Aluminum Stainless steel, mat. no..57 Duran glass Duran glass, black PTFE (Teflon) FKM (Viton) Polycarbonate NBR /32 Siemens AP 0 208

Gas path (high-pressure version) Siemens AG 208 Extractive continuous process gas analysis General information Legend for the gas path figure Sample gas inlet; inlet pressure 6 Bypass restrictor - Without internal pressure regulator: 2 000 hpa (abs.), regulated 7 Pressure switch - With internal pressure regulator: 2 000... 6 000 hpa (abs.) 8 Flow measuring tube 2 Sample gas outlet; sample gas flows off free of dynamic pressure 9 Purging gas connection 3 Pressure regulator (order version) 0 Restrictor O 2 sensor Sample gas restrictor 5 Pressure sensor 9 2 3 0 O 2 sensor (KAZ /KIZ) 5 6 P 7 8 F Gas path, high-pressure version The sample gas pressure (2 000 to 6 000 hpa) is regulated by the pressure regulator (3) at approx. 2 000 hpa or is provided by the operator with 2 000 hpa. This pressure is applied at the restrictor (0). The restrictor (0) reduces the pressure such that a sample gas flow of 5 to 30 l/h is created. This flow is subdivided via the sample gas restrictor () and the adjustable bypass restrictor (6) such that there is a sample gas flow of 7.5 l/h through the sensor. If the sample gas can flow off into the atmosphere unhampered, the sample gas pressure corresponds to the atmospheric pressure. If the sample gas flows off via an exhaust gas line, it works like a flow resistance. If the resulting dynamic pressure exceeds 00 hpa (rel.), a maintenance demanded is output. Siemens AP 0 208 /33

Extractive continuous process gas analysis General information Gas path (low pressure) Siemens AG 208 Legend for the gas path figure Sample gas inlet; flow 25 ml/min (7.5 l/h) 5 Pressure switch 2 Sample gas outlet; sample gas flows off free of dynamic pressure 6 Flow measuring tube 3 O 2 sensor 7 Purging gas connection Pressure sensor 8 Restrictor 7 2 8 O 2 sensor (KAZ /KIZ) 3 P 5 6 F Gas path, low-pressure version With the low-pressure version, the sample gas flow must be set externally to 25 ml/min. With a built-in pressure switch, the sample gas pressure is approx. 30 hpa above the current atmospheric pressure since the sample gas flows off via a restrictor. If the resulting dynamic pressure exceeds 00 hpa (rel.), a maintenance demanded is output. In order to reduce the 90% time, we recommend installation of a bypass upstream of the gas inlet which then provides a faster exchange of gas. This is particularly important with long sample gas lines between the gas sampling point and the analyzer. Please make absolutely sure that the flow in the does not exceed 25 ml/min. /3 Siemens AP 0 208

Siemens AG 208 Extractive continuous process gas analysis Gas path (low pressure with integrated sample gas pump) Legend for the gas path figure Sample gas inlet 6 Flow measuring tube 2 Sample gas outlet; sample gas flows off free of dynamic pressure 7 Sample gas pump 3 O 2 sensor 8 Restrictor Pressure sensor 9 Purging gas connection 5 Needle valve General information 9 2 7 5 Δp O 2 sensor CIZ/CAZ 3 Oxygen sensor module, complete 8 F 6 Low-pressure version with integral sample gas pump The device version " low-pressure with pump" is equipped with a sample gas pump which automatically provides a constant sample gas flow of 25 ml/min through the sensor. By means of an internal bypass, the total flow of sample gas through the analyzer is increased to approx. 0. l/min. This measure significantly improves the analyzer's response time. Siemens AP 0 208 /35

Extractive continuous process gas analysis General information Function Siemens AG 208 The measuring cell consists of a cylindrical (pipe-shaped) ZrO 2 membrane. The sample gas (low O 2 content) flows at a constant rate through the inside of the membrane, which is regulated at 650 C. The exterior of the sensor is exposed to the ambient air (approx. 2 % O 2 ). Both sides of the ZrO 2 membrane are coated with thin platinum films that act as electrodes. This forms a solid, electrochemical cell. The amount of oxygen atoms ionized depends on the oxygen concentration at the electrodes. The differences in concentration at each side means that a differential partial pressure prevails. Since ZrO 2 conducts ions at 650 C, ionic migration takes place in the direction of the lower partial pressure. An oxygen gradient arises across the width of the ZrO 2 membrane, which, according to equation (), results in an electrical potential difference between the platinum electrodes. Defects in the crystal lattice, caused by contamination of the ZrO 2 material with Y 2 O 3 and/or CaO (introduced originally to prevent cracks forming in ceramic material) make it easier for O 2 ions to diffuse in the ZrO 2 grid. Catalytically active ZrO 2 sensor (CAZ) The electrode material is made of platinum (Pt). This type of sensor has a higher cross-sensitivity when flammable accompanying gas components are present. Catalytically inactive ZrO 2 sensor (CIZ) The catalytically inactive sensor has the same general design as the CAZ. The contacts and electrode surface inside the pipe are made of a specially developed material which largely prevents catalytic oxidation except of H 2, CO and CH. 2 3 5 6 7 Pipe made of ZrO 2 and Y 2 O 3 or ceramic CaO-mixed oxide Ceramic protective coating Sample electrode (Pt) Reference electrode (Pt) Thermoelement Contact to reference electrode Contact to sample electrode Measuring effect U = U A + RT/F (In [O 2,air] - In [O 2 ] (equation ) U measuring effect U A asymmetric voltage (voltage, at [O 2 ] = [O 2,air] T ceramic temperature [O 2,air] O 2 concentration in the air [O 2 ] O 2 concentration in sample gas Note The sample gas must be fed into the analyzer free of dust. Condensation should be avoided. Therefore, gas modified for the measuring tasks is necessary in most application cases. Calibration Calibration of the calibration point is carried out as with the other analyzers of after a maximum of days by connecting the calibration gas O 2 in residual N 2 at concentrations of approx. 60 to 90% of the master measuring range. Contrary to the other analyzers of, the zero point calibration cannot be carried out using pure nitrogen, but with a "small" concentration of oxygen in nitrogen appropriate to the selected measuring range (e.g.: Measuring range 0 to 0 vpm; calibration gas approx. 2 vpm O 2 in residual N 2 ). Essential characteristics Four measurement ranges freely parameterizable, all measurement ranges linear Galvanically isolated measurement value output 0/2/ through 20 ma (also inverted) and as per NAMUR Autoranging selectable; possibility of remote switching Storage of measured values possible during adjustments Wide range of selectable time constants (static/dynamic noise suppression); i.e. the response time of the device can be adapted to the respective measuring task Easy handling thanks to menu-driven operation Low long-term drift Two control levels with their own authorization codes for the prevention of accidental and unauthorized operator interventions Automatic measuring range calibration can be configured Operation based on the NAMUR recommendation Monitoring of the sample gas (via pressure switch) Customer-specific analyzer options such as: - Customer acceptance -TAG labels - Drift recording Simple handling using a numerical membrane keyboard and operator prompting Smallest span 0 to 0 vpm O 2 Largest span 0 to 00 % (testing with ambient air) Internal pressure sensor for correction of the influence of sample gas pressure fluctuations, principle of operation /36 Siemens AP 0 208

Siemens AG 208 Extractive continuous process gas analysis Influence of interfering gas Catalytically active sensor (CAZ) Very large cross-interference of all combustible accompanying gases. Thus not suitable for use with combustible accompanying gases! Catalytically inactive sensor (CIZ) There is only a slight cross-interference in the case of accompanying gases with a concentration in the range of the O 2 concentration. H 2, CO and CH still have a noticeable effect in the case of flammable accompanying gas components. Measured component / interfering Diagonal gas offset gas 78 vpm O 2 /0 vpm CO -6. vpm 0 vpm O 2 /0 vpm CO -0.6 vpm 7 vpm O 2 / 25 vpm CH -0.3 vpm 25 vpm O 2 / 357 vpm CH -. vpm 25 vpm O 2 / 70 vpm H 2-3 vpm 5 vpm O 2 / 9.6 vpm H 2-0.55 vpm 70 vpm O 2 / 930 vpm C 2 H -8 vpm Examples of typical diagonal gas offsets on a catalytically inactive sensor The listed deviations depend on the exemplar and can deviate up to ± 0.2 vpm. The actual deviation must be determined individually or the error will be eliminated through a corresponding calibration measure (displacement of the diagonal gas offset). General information Siemens AP 0 208 /37

Extractive continuous process gas analysis 9" rack unit Technical specifications Siemens AG 208 General Measurement ranges, internally and externally switchable; automatic measuring range switchover also possible Smallest possible span (relating to 0... 0 vpm O 2 sample gas pressure 000 hpa absolute, 0.5 l/min sample gas flow, and 25 C ambient temperature) Largest possible measuring span 0... 00% Operating position Front wall vertical Conformity CE mark in accordance with EN 5008-, EN 50082-2 and RoHS Design, enclosure Degree of protection IP20 according to EN 60529 Weight Approx. kg Electrical characteristics EMC interference immunity (electromagnetic compatibility) In accordance with standard requirements of NAMUR NE2 (08/98) and EN 6326 Electrical safety In accordance with EN 600-, overvoltage category II Power supply 00... 20 V AC (nominal range of use 90... 32 V), 8... 63 Hz or 200... 20 V AC (nominal range of use 80... 26 V), 8... 63 Hz Power consumption Approx. 37 VA Fuse values 00... 20 V:.0T/250 200... 20 V: 0.63T/250 Gas inlet conditions Sample gas flow through the sensor 7.5 l/h Overall consumption 5... 30 l/h Permissible sample gas pressure Without internal pressure regulator 2 000 hpa (abs.) With internal pressure regulator 2 000... 6 000 hpa (abs.) Sample gas temperature Min. 0... max. 50 C, but above the dew point Sample gas humidity < % relative humidity Dynamic response Warm-up period At room temperature < 30 min (the technical specification will be met after 2 hours) Damping (electrical time constant) 0... 00 s, configurable Dead time (high-pressure version) 0... 30 s (purging time of the gas path in the unit at 25 ml/min) Dead time (low-pressure version without pump) Dead time (low-pressure version with pump) Time for device-internal signal processing Pressure correction range Pressure sensor internal <5s <0s <s 800... 00 hpa (abs.) Measuring response Output signal fluctuation Zero point drift Measured-value drift Repeatability Detection limit Linearity error Influencing variables Ambient temperature Sample gas pressure only possible if the sample gas can flow out into the ambient air Residual gases, deviation from zero point Catalytically active sensor (CAZ) Catalytically inactive sensor (CIZ) Sample gas flow Power supply Electrical inputs and outputs Analog output Relay outputs Analog inputs Digital inputs Based on sample gas pressure 03 hpa absolute, 7.5 l/min sample gas flow and 25 C ambient temperature < ± % of the smallest possible measuring range according to rating plate, with electronic damping constant of s < ± % of the current span/month < ± % of the current span/month < 3% of the current measuring span % of current measuring range, < 0. vpm in measuring range 0... 0 vpm < 2% of the current measuring span Based on sample gas pressure 03 hpa absolute, 7.5 l/min sample gas flow and 25 C ambient temperature < 2%/0 K referred to current measuring span With deactivated pressure compensation: < % of current span/% pressure change With activated pressure compensation: < 0.2% of current span / % pressure change Only gases with non-combustible residual gas components can be introduced Residual gas concentration of 0 vpm H 2 ; CO and CH have a lower cross-interference; higher HCs are negligible < 2% of the smallest possible span with a change in flow of 0 ml/min < 0.% of the current measuring range with rated voltage ± 0% 0/2/... 20 ma, 20 ma (NAMUR), isolated; max. load 750 6, with changeover contacts, freely parameterizable, e.g. for measuring range identification; load: 2 V AC/ DC/ A, isolated 2, dimensioned for 0/2/ 20 ma for external pressure sensor and correction of influence of residual gas (correction of cross-interference) 6, designed for 2 V, isolated, freely parameterizable, e.g. for measurement range switchover Serial interface RS 85 Options AUTOCAL function each with 8 additional digital inputs and relay outputs, also with PROFIBUS PA or PROFIBUS DP Climatic conditions Permissible ambient temperature -0... +70 C during storage and transportation, 5... 5 C in operation Permissible humidity < 90% relative humidity as annual average, during storage and transportation (must not fall below dew point) /38 Siemens AP 0 208

Siemens AG 208 Extractive continuous process gas analysis Selection and ordering data gas analyzer 9" rack unit for installation in cabinets Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Article No. 7MB20-777 7-7A 7 7 Sensor ZrO 2 : Catalytically active cell (CAC) 0 0 ZrO 2 : Catalytically inactive cell (CIC) 9" rack unit Cannot be combined ZrO 2 : Catalytically active cell (CAC); with differential pressure sensor 2 2 ZrO 2 : Catalytically inactive cell (CIC); with differential pressure sensor 3 3 Sample gas pressure High pressure, without pressure regulator 2 000 hpa (abs.) A A High pressure, with pressure regulator 2 000... 6 000 hpa (abs.) B B Low pressure, with pump Atmosphere C C Low pressure, without suction pump Atmosphere D D Gas connection Input Clamping ring connection 6 mm A Output Fittings 6 mm Input Clamping ring connection ¼" B Output Fitting ¼" Add-on electronics Without 0 AUTOCAL function With 8 additional digital inputs/outputs With 8 additional digital inputs/outputs and PROFIBUS PA interface 6 With 8 additional digital inputs/outputs and PROFIBUS DP interface 7 Power supply 00 to 20 V AC, 8 to 63 Hz 200 to 20 V AC, 8 to 63 Hz Explosion protection Without Language German 0 English French 2 Spanish 3 Italian Additional versions Add "-Z" to Article No. and specify Order code Telescopic rails (2 units) TAG labels (specific lettering based on customer information) Clean for O 2 service (specially cleaned gas path) Measuring range indication in plain text, if different from the standard setting Special setting (only in conjunction with an application no., e.g. extended measuring range) Extended special setting (only in conjunction with an application no., e.g. determination of cross-interferences) Accessories RS 85/Ethernet converter RS 85/RS 232 converter RS 85/USB converter AUTOCAL function each with 8 digital inputs/outputs AUTOCAL function 8 digital inputs/outputs each and PROFIBUS PA AUTOCAL function 8 digital inputs/outputs each and PROFIBUS DP Set of Torx screwdrivers Order code A3 B03 Y02 Y Y2 Y3 Article No. A5E00852383 C795-Z589-U A5E00852382 C795-A380-D5 A5E00057307 A5E0005732 A5E382625 0 A Siemens AP 0 208 /39

Extractive continuous process gas analysis 9" rack unit Dimensional drawings Siemens AG 208 38.5 35.5 73 28 27.5 5.6 s 72 9.5 M 82 86.5 0 0 36 0 32 77 320 35.5 0.6 37.7 65 83, 9" rack unit, size in mm /0 Siemens AP 0 208

Circuit diagrams Pin assignment (electrical connections) Siemens AG 208 Extractive continuous process gas analysis 9" rack unit, 9" rack unit, pin assignment Siemens AP 0 208 /

Extractive continuous process gas analysis Siemens AG 208 9" rack unit Connector SUB-D 37F (option) M M 9 37 8 36 7 35 6 3 5 33 32 3 3 2 30 29 0 28 9 27 8 26 7 25 6 2 5 23 22 3 2 2 20 GND NC NC Digital input -P Digital input 3-P Digital input 2-P Digital input -P Digital input 0-P Digital input 9-P Digital input 8-P Digital input 7-P Digital input 7 to -N Relay Relay 3 Relay 2 Relay Relay 0 Relay 9 Relay 8 Relay 7 GND Isolated via optocoupler "0" = 0 V (0....5 V) "" = 2 V (3... 33 V) Contact load max. 2 V/ A, AD/DC for shown relay contact position, the relay has zero current Connector SUB-D 9F-X90 PROFIBUS DP Optional Connector SUB-D 9M-X90 PROFIBUS PA 9 8 7 6 5 3 2 DGND CNTR-N CNTR-P/direction control RxD/TxD-N (A) RxD/TxD-P (B) VP /+ 5 V 9 8 7 6 5 3 2 PA-N(-) PA-P(+), 9" rack unit, pin assignment of the AUTOCAL plate and PROFIBUS plug /2 Siemens AP 0 208

Gas connections and pin assignment Siemens AG 208 Extractive continuous process gas analysis 9" rack unit Sample gas outlet Sample gas inlet 5-pin connector: Digital inputs and analog inputs/outputs 9-pin connector: RS 85 2 Purge gas inlet 9-pin interface connector (Optional): e.g. PROFIBUS Gas connections Sample gas inlet: Clamping ring connection 6 mm or ¼" Sample gas outlet: Fittings 6 mm or ¼" 25-pin connector: Digital inputs and relay outputs Mains connection and miniature fuses 37-pin connector: Digital inputs and relay outputs (optional), 9" rack unit, gas connections and electrical connections Siemens AP 0 208 /3

Extractive continuous process gas analysis Siemens AG 208 Documentation, suggestions for spare parts Selection and ordering data More information Operating instructions Gas analyzers of and ULTRAMAT 23 Schnittstelle/Interface PROFIBUS DP/PA German and English Article No. A5E00058 The complete documentation is available in various languages for downloading free of charge: http://www.siemens.com/processanalytics/documentation Selection and ordering data Description 7MB20 2 years (quantity) 5 years (quantity) Article No. Pressure regulator as spare part x A5E0008972 Flowmeter x A5E00656 Adapter plate, LC display/keypad x C795-A37-B605 LC display x A5E3786 Connector filter x W750-E5602-K2 Fuse, T 0.63 A, line voltage 200 20 V x 2 W7905-L00-T630 Fuse, T A, line voltage 00 20 V x 2 W7905-L0-T00 / Siemens AP 0 208