Fisher 4194H Differential Pressure Indicating Controllers

Similar documents
Fisher 4194 Differential Pressure Indicating Controllers

4194 Series Differential Pressure Indicating Controllers

Fisher 4195K Gauge Pressure Indicating Controllers

Fisher L2sj Low Emission Liquid Level Controller

Fisher 4660 High-Low Pressure Pilot

Fisher C1 Pneumatic Controllers and Transmitters

Fisher C1 Pneumatic Controllers and Transmitters

Model 4000 Pressure Controller

Fisher 4660 High-Low Pressure Pilot

Type 4660 High-Low Pressure Pilot

Fisher 2625 and 2625NS Volume Boosters

Type R622 Pressure Reducing Regulator

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

1805 Series Relief Valves

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters

T208VR Series Tank Blanketing Vacuum Regulator

1805 Series Relief Valves

PRO-50 Instrument Supply Regulator

C1 Series Pneumatic Controllers and Transmitters

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

S300 Series. Valve Link. Features. Fisher Controls

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Fisher C1 Pneumatic Controllers and Transmitters

670 Series Panel-Mounted Loading Regulators

Type EZH Relief or Backpressure Regulator

Fisher DSA Steam-Atomized Desuperheater

Fisher DVI Desuperheater Venturi Inline

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Y692VB Series Vacuum Breaker

Design DSA Steam-Atomized Desuperheater

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Fisher and Whisper Disk Diffusers

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

1305 Series Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

Model 130M Pneumatic Controller

Type 299 Pressure Reducing Regulators

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

64 Series Pressure Reducing Regulators

Powers Controls RC 195 Single Input Receiver-Controller

Fisher 8532 High-Performance Butterfly Valve

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Powers Controls RC 195 Multiple Input Receiver- Controller

OPERATING AND MAINTENANCE MANUAL

RESIDENTIAL REGULATORS

Type Cronos Pressure Reducing Regulator

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

66 Series Direct-Operated Regulators and Vacuum Service Equipment

1200 Series Pressure Regulators

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Types 95L and 95H Pressure Regulators

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

9700 Transmitter Submersible hydrostatic level transmitter

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type 99 Pressure Reducing Regulators

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

RC 195 Receiver-Controller

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Electropneumatic Transducer (I/P) Installation, Operation and

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

MEGR-1912 Instruction Manual

Model Series 62 Constant Differential Relay

Types 749B and R130 Changeover Manifolds

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Type ACE95jr Tank Blanketing Valve

Float Operated Level Controllers

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Safety manual for Fisher GX Control Valve and Actuator

Type 1190 Low-Pressure Gas Blanketing Regulator

Types ACE95 and ACE95Sr Tank Blanketing Valves

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

1301 Series High-Pressure Regulators

Types ACE95 and ACE95Sr Tank Blanketing Valves

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

The Ins and Outs of I/P Transducers

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Page 1 of 12

Masoneilan* 78 Model Air Filter Regulator

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

1800CPB2 Pilot-Loaded Service Regulators

1800C and 1800C-HC Service Regulators

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Air Operated Hydraulic Pumping Systems to 50,000 psi

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

How to specify a product. Process Sensors and Mechanical Instruments

TECHNICAL DATA. Q= Cv S

Transcription:

4194H Differential Pressure Controllers D200049012 Product Bulletin Fisher 4194H Differential Pressure Indicating Controllers Fisher 4194H differential pressure indicating controllers show process differential pressure and set point on an easy to read process scale. These high static pressure controllers sense two different pressures and compare the difference between these pressures with an operator adjusted set point. A pneumatic signal is then delivered to a control element to change the process differential pressure toward the set point. 4194H controllers use a differential pressure unit such as the Barton 199 for differential pressure up to 5.2 bar (75 psi). The product line includes proportional only, proportional plusreset, and differential gap controllers. The controllers are also available with anti reset windup, internal auto/manual station, and remote set point adjustability (see table 1). 4194H controllers are used throughout industries where process monitoring and accurate measurement of differential pressure are required. W5825 CONTROLLER WITH DIFFERENTIAL UNIT PROCESS DIFFERENTIAL INDICAR SET POINT ADJUSTMENT Features Easy Maintenance Simple design of the controller allows fast, easy maintenance and minimal spare parts inventory. W5826 1 GAUGE INTERIOR OF CONTROLLER OUTPUT GAUGE Easy Adjustment Adjustments of set point and zero and span of the process pointer, and switching between direct and reverse action are accomplished quickly and without special tools. Also, the set point and proportional band can be adjusted with no interaction between the two adjustments. Highly Visible Display Two red pointers on a 114 mm (4.50 inch) long white on black scale show differential pressure and deviation from set point at a glance. Two other gauges monitor supply and output pressures. Low Air/Gas Consumption The relay and nozzle design reduces the steady-state consumption rate to as low as 0.07 m 3 /hr (2.5 scfh); less than the 6 scfh requirement set for the oil and gas industry by the US Environmental Protection Agency (New Source Performance Standards Subpart OOOO, EPA HQ QAR 2010-0505). Corrosion Resistant Thermoplastic housing withstands a broad range of corrosive environments. Internal constructions are available to resist a corrosive supply pressure media. www.fisher.com

Product Bulletin 4194H Differential Pressure Controllers D200049012 Specifications Available Configurations See table 1 Sensing Element Range (Input Signal) See table 2 Process Scale Linear, square root, or others on request (1) Process Connections Standard: 1/4 NPT internal stainless steel (all input ranges) Optional: 1/2 NPT external stainless steel Output Signal Proportional or Proportional Plus Reset Range: 0.2 to 1.0 bar (3 to 15 psig) or 0.4 to 2.0 bar (6 to 30 psig) Differential Gap Output: 0 and 1.4 bar (0 and 20 psig) or 0 and 2.4 bar (0 and 35 psig) Action: Field reversible between direct (increasing sensed pressure increases output pressure) or reverse (increasing sensed pressure decreases output pressure) Supply and Output Connections 1/4 NPT internal Supply Pressure Requirements (2) See table 4 Supply Pressure Medium Air or non-corrosive Natural Gas Remote Set Point Pressures 0.2 to 1.0 bar (3 to 15 psig) or 0.4 to 2.0 bar (6 to 30 psig) Construction Materials See table 3 Controller Adjustments Proportional Band: 5 to 500% of process scale range Reset: Adjustable from 0.01 to more than 74 min per repeat (from 100 to less than 0.0135 repeats per min) Differential Gap Controllers: Adjustable from 1 to 100% of process scale range Set Point: Continuously adjustable from 0 to 100% of the scale range Controller Performance (3) Repeatability: 0.4% of process scale range Dead Band: Less than 0.2% of process scale range Steady State Air Consumption (4)(5) 0.2 to 1.0 bar (3 to 15 psig) Output: 0.08 m 3 /hr (2.8 scfh) 0.4 to 2.0 bar (6 to 30 psig) Output: 0.07 m 3 /hr (2.5 scfh) Operative Ambient Temperature Limits (2)(6) 40 to 70 C ( 40 to 160 F) (continued) Table of Contents Features... 1 Construction Features... 7 Principle of Operation... 5 4194H Controllers... 5 Auto/Manual Option... 6 Installation... 9 Ordering Information... 10 Applications... 10 Construction... 10 2

4194H Differential Pressure Controllers D200049012 Product Bulletin Specifications (continued) Hazardous Area Classification Complies with the requirements of ATE Group II Category 2 Gas and Dust Mounting Controller is mounted on a pipestand Meets Customs Union technical regulation TP TC 012/2011 for Groups II/III Category 2 equipment II Gb c T* III Db c T* Housing Designed to NEMA 3 (Weatherproof) and IEC 529 IP54 Specifications Approximate Weight Controller: 4.5 kg (10 lb) without the differential pressure unit Differential Pressure Unit: 21.5 kg (47 lb) Total Weight (controller and differential pressure unit): 26 kg (57 lb) (with a Barton 199 Differential Pressure Unit) NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology. 1. Consult your Emerson sales office or Local Business Partner for additional information. 2. The pressure/temperature limits in this document and any applicable standard or code limitation for valve should not be exceeded. 3. With Barton 199 differential pressure unit. 4. Normal m 3 /hr normal cubic meters per hour (m 3 /hr, 0 C and 1.01325 bar, absolute). Scfh standard cubic feet per hour (ft 3 /hr, at 60 F and 14.7 psig). 5. Without auto/manual switch. With auto/manual switch, add 0.01 m 3 /hr (0.5 scfh) 6. Also for transportation and storage limits. Table 1. Available Configurations TYPE NUMBER (1) 4194HA 4194HAE 4194HAM 4194HAME 4194HB 4194HBE 4194HBF 4194HBFE 4194HBM 4194HBME 4194HBFM 4194HBFME 4194HC 4194HCE 4194HCF 4194HCFE 4194HCM 4194HCME 4194HCFM 4194HCFME 4194HS 4194HSE 4914HSM 4194HSME Proportional Only Proportional Plus Reset Proportional Plus Reset Plus Rate (2) CONFIGURATIONS Differential Gap Anti Reset Windup Remote Set Point Internal Auto/ Manual Station 1. Reverse acting constructions are designated by an R added to the type number. 2. Consult your Emerson sales office or Local Business Partner for information on rate. 3

Product Bulletin 4194H Differential Pressure Controllers D200049012 Table 2. Process Sensor (Barton 199) Ranges and Pressure Ratings AVAILABLE DIFFERENTIAL UNIT OPERATING RANGES STATIC OPERATING RANGE mbar Inch wc Bar Psig 0 to 50 0 to 63 0 to 125 0 to 188 0 to 250 Bar 0 to 1.0 0 to 3.4 0 to 5.2 0 to 20 0 to 25 0 to 50 0 to 75 0 to 100 (1) (1) Psi 0 to 15 0 to 50 0 to 75 1. Available in ranges of 0 to 70 bar (0 to 1000 psig), 0 to 172 bar (0 to 2500 psig), and 0 to 413 bar (0 to 6000 psig). Actual static pressure depends on differential pressure unit rating and materials. Table 3. Construction Materials Product Part Standard Material Optional Material 4194H Controllers Barton 199 Differential Pressure Unit Table 4. Supply Pressure Data Bar Psig Case and cover Polyester plastic Exterior tubing Copper Aluminum,stainless steel, steel, polyethylene Exterior fittings C36000 (brass) Aluminum, stainless steel, steel, polyethylene Interior tubing Copper S30400 (304 stainless steel) Nozzle S30300 (303 stainless steel) Flapper S31600 (316 stainless steel) Relay springs S30200 (302 stainless steel), steel Relay O rings Nitrile Relay diaphragms Nitrile Other relay metal parts Aluminum, stainless steel Feedback bellows assembly C51000 (bronze) S32100 (321 stainless steel) Supply and output gauges Brass (wetted parts only) Stainless steel (wetted parts only) Remote set point bellows N09902 (nickel alloy) Mounting plates Zinc plated steel Bellows Stainless steel Housing Steel Stainless steel Output Signal Range Normal Operating Supply Pressure (1) Maximum Pressure to Prevent Internal Damage (2) 0.2 to 1.0 or 0 and 1.4 (differential gap) 1.4 3.4 0.4 to 2.0 or 0 and 2.4 (differential gap) 2.4 3.4 3 to 15 or 0 and 20 (differential gap) 20 50 6 to 30 or 0 and 35 (differential gap) 35 50 1. If this pressure is exceeded, control stability may be impaired. 2. If this pressure is exceeded, damage to the controller may result. 4

4194H Differential Pressure Controllers D200049012 Product Bulletin Figure 1. Operational Schematic of Fisher 4194H Differential Pressure Controllers PROCESS POINTER REMOTE SET POINT CONNECTED HERE INPUT ELEMENT CONNECTED HERE CONNECTING LINK MANUAL SET POINT ADJUSTMENT BEAM PROPORTIONAL FLAPPER (VENTED) PROPORTIONAL BAND ADJUSTMENT FEEDBACK LINK FEEDBACK MOTION DIRECT ACTION QUADRANT REVERSE ACTION QUADRANT INPUT MOTION FLAPPER DETAIL OUTPUT CONTROL DEVICE FLAPPER PIVOT NOZZLE OUTPUT PROPORTIONAL NOZZLE RELAY PROPORTIONAL NOZZLE PROPORTIONAL ONLY CONTROL OUTPUT PROPORTIONAL NOZZLE OUTPUT NOZZLE OUTPUT VALVE RELAY RELIEF VALVE VALVE RELAY RELAY C0742 PROPORTIONAL PLUS CONTROL PROPORTIONAL PLUS CONTROL WITH ANTI WINDUP DIFFERENTIAL GAP CONTROL Principle of Operation 4194H Controllers Refer to the proportional only control diagram in figure 1. The input element is connected to the process pointer and flapper by a connecting linkage. As the process differential pressure increases in a direct acting controller, the flapper moves toward the nozzle, restricting flow through the nozzle and increasing nozzle pressure. When this occurs, relay action increases the output pressure (delivery) of the controller. Output pressure is fed back to the proportional bellows. The action of the proportional bellows counters the flapper movement that resulted from the process differential pressure change, and backs the flapper away from the nozzle. Set point adjustment also changes the proximity of the nozzle and flapper; however, when the set point is changed, the nozzle moves with respect to the flapper. When 5

Product Bulletin 4194H Differential Pressure Controllers D200049012 Figure 2. Schematic of Auto/Manual Option AUMATIC POSITION AU/MANUAL SWITCH MANUAL LOADER MANUAL LOADER KNOB OUTPUT CONTROL DEVICE PLASTIC TUBE METAL BALL RELAY MANUAL POSITION RELAY OUTPUT OUTPUT CONTROL DEVICE AU/MANUAL SWITCH MANUAL LOADER OUTPUT 48A5230 A A2927 1 the controller is in the reverse acting mode (see flapper detail in figure 1), an increase in process differential pressure causes a decrease in output pressure. The schematic diagram (figure 1) emphasizes detail of construction variations between control modes. Refer to table 1 for a complete description of type number suffixes. In addition to the 4194HA (proportional only) version, the 4194HB controller is available for proportional plus reset control. In this controller, output pressure is fed back to the reset bellows as well as to the proportional bellows. Remote set point is available on all controllers. Anti reset windup is available on all controllers with reset. The 4194HS controller provides differential gap control. In this version, feedback pressure is piped directly to the reset bellows, reinforcing the change in flapper position rather than the counteracting it. This construction causes the controller output to switch from full supply pressure to zero pressure or vice versa. Auto/Manual Option Controllers with the auto/manual option have piping on the output side of the relay as shown in figure 2. Supply pressure to the relay is also applied to the manual loader. The manual loader, functioning as a regulator, applies pressure to one side of the plastic tube and to the auto/manual switch. Output pressure from the relay registers on the other side of the plastic tube as well as in the auto/manual switch. When the auto/manual switch is in the MAN position, the output of the manual loader, which is adjustable by the manual loader knob, is channelled through the auto/manual switch and becomes the output of the controller. When the auto/manual switch is in the AU position, the output of the relay is channelled through the switch to become the output of the controller. 6

4194H Differential Pressure Controllers D200049012 Product Bulletin Before the auto/manual switch is operated, the output of the relay must equal the output of the manual loader to avoid bumping the process. Adjusting the set point varies the pressure on the left hand side of the plastic tube. Adjusting the manual loader knob varies the pressure on the right hand side. When the pressures are equal, the metal ball is centered in the tube. Pressure imbalance will force the ball to one end of the tube where it forms a seal, blocking air flow through the tube. Construction Features Simple Relay Maintenance A clean out wire provides a fast, easy means of cleaning the relay primary orifice during service. Pressure Protection for the Case A rubber plug in the plastic case pops out to prevent excessive pressure buildup inside the case, thus preventing structural damage. Remote Set Point The capability of adjusting the set point from a remote location is available as an option on the 4194H controllers. Auto/Manual Capability An internal auto/manual station is available for smooth bumpless transfer from automatic to manual and manual to automatic control of the controller output. The two position switch, showing either automatic or manual mode, is clearly visible with the controller cover closed. External Feedback In controller override applications, this option minimizes reset windup in the secondary controller (see figure 3). This option is available only with the two mode (4194HB) controllers. Figure 3. Schematic of External Feedback Option Easy Direct/Reverse Switching Controller action can be switched from direct to reverse or vice versa by simply loosening the screws on the proportional band cover and moving the cover out to rotate the proportional band knob to the desired action (see figure 4). NOZZLE OUTPUT Easy Mode Conversion Conversion from proportional to proportional plus reset control requires the addition of a reset valve and two pieces of tubing. Conversion from proportional to differential gap control requires the addition of one piece of tubing. Anti Reset Windup Anti reset windup is available with proportional plus reset controllers. Relief valve may be installed to limit reset windup in either direction. 47A0975 A A3238 1 VALVE PROPORTIONAL ETERNAL FEEDBACK OUTPUT OF HIGH OR LOW SELECT RELAY RELAY OUTPUT NOZZLE 7

Product Bulletin 4194H Differential Pressure Controllers D200049012 Figure 4. Controller Construction Details W3679 AU/MANUAL OPTION CONNECTING LINK 2 2 ZERO ADJUSTMENT SPAN ADJUSTMENT PROPORTIONAL BAND ADJUSTMENT W3439 1 W5826 Notes: 1 White portion of adjustment enables direct controller action; black portion enables reverse controller action. 2 For the process pointer. 8

4194H Differential Pressure Controllers D200049012 Product Bulletin Figure 5. Dimensions 260 (10.25) REMOTE SET POINT CONNECTION 330 (13.00) P VIEW 1/2 NPT (2 PLACES) FRONT VIEW 31 (1.22) 147 (5.80) 1/4 18 NPT ETERNAL FEEDBACK CONNECTION, WHEN APPLICABLE 66 (2.56) 1/4 NPT (2 HOLES) 1/4 NPT (2 PLACES) 351 (13.81) 206 (8.12) 18A5903 D A2926 2 BOTM VIEW SIDE VIEW mm (INCH) Installation A 4194H controller mounts on a pipestand and must be installed with the vent opening facing down. The coupling is secured to the pipestand by set screws. Figure 5 shows controller dimensions including those necessary for installation. 9

Product Bulletin 4194H Differential Pressure Controllers D200049012 Ordering Information When ordering, specify: Application 1. Description of the service, such as throttling or on off 2. Pressure range, composition, and temperature of process fluid 3. Ambient temperature Construction Refer to the specifications and the Construction Features section. Carefully review each specification and feature, indicating your choice whenever a selection is to be made. Refer to table 1 for type numbers; add R to any type number if reverse action is desired. 10

4194H Differential Pressure Controllers D200049012 Product Bulletin 11

Product Bulletin 4194H Differential Pressure Controllers D200049012 Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 121991, 2017 Fisher Controls International LLC. All rights reserved.