DECLARATION OF INCORPORATION

Similar documents
PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

double rotary environmental cartridge mechanical seals 302 TM series

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

SCA Series Inverted Bucket Steam Traps

Installation Operation Maintenance

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

MFP14-PPU (Vented) Automatic Packaged Pump Units

System Pressure Manager Standard & System Pressure Manager Plus

553 Series.

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

GREIG FILTERS, INC. OPERATION MANUAL

DF1 and DF2 Diffusers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

TSS21 Sealed Thermostatic Steam Tracer Trap

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Vertical and Horizontal Bladder Tanks

VERTICAL BLADDER TANK

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

INSTALLATION INSTRUCTIONS

776 Cryogenic Safety Valve

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

HORIZONTAL BLADDER TANK

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

Series 58 SAFETY VALVES 312

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

OPERATION MANUAL NTF-15

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

SB-E ISS.01. Operation Manual: KB-522 & KB-522-SS Pressure Feed Cup E P ITW Finishing Systems and Products

756 Safety Relief Valves

Manual Actuated Boiler Blowdown Valves

Portable Oil Lube Air Compressors

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Interface Devices, Inc. Hydraulic Mini Mule

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

AVM7 Stainless Steel Thermostatic Air Vent

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

CVS10 Sanitary Check Valves

Siphon vessel / Priming aid

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Mainsboost Installation, Operation & Maintenance Instructions

Pressure Automated Calibration Equipment

TECHNICAL DATA. Trimpac 244a. September 16, 2013

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

INSTALLATION, OPERATION and MAINTENANCE MANUAL

FOAM TANK (1/2) DATA SHEET

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

OPERATION MANUAL NTF-60 Plus

MEDICAL EQUIPMENT CATALOG

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Unit 24: Applications of Pneumatics and Hydraulics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Chesterton Seal Support Systems Type BSS & PSS

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Installation, Operation, and Maintenance Manual

Installation, commissioning and servicing instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Inert Air (N2) Systems Manual

6900 Maintenance Instruction System Flush

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Budget Range Operators Handbook

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

29 SERIES - SAFETY VALVE

S and SF Inverted Bucket Steam Traps

CAST IRON SAFETY VALVE TYPE 6301

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

DCV6 Disc Check Valve

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

REFRIGERATION SYSTEM COMPONENTS

Transcription:

AESSEAL (MCK) Ltd. Systems Division 139a Hillsborough Old Road Lisburn Northern Ireland BT27 5QE Tel +44 (0) 2892 669966 Fax +44 (0) 2892 669977 When selecting and installing suitable Barrier Fluid System for your Double Seal application consideration should be given to the following selection parameters. These parameters must also be considered in conjunction with your specific site standards and requirements. 1. Materials of Construction Consideration must always be given when selecting and installing a barrier system to the suitability of its materials of construction with reference to the environment and process within which it will be operating. A full list of system materials of construction is available on request. 2. Barrier Fluid Page 1 of 6 a. When selecting and installing a Barrier Fluid the site must determine its compatibility with the process to which it is to be applied. Consideration must also be given to personnel and environmental exposure when selecting and installing the barrier medium and appropriate precautions taken and protective equipment and clothing worn. b. The flammability and auto ignition characteristics of the barrier fluid must be considered in conjunction with the system surface temperature and its location to other equipment. c. Vaporisation must also be considered. Barrier fluids such as solvents should not be used due to their low vaporisation temperatures. 3. Temperature a. Site specific surface temperature limits must always be considered. Where the surface temperature of the system is likely to exceed these site limits a guard should be placed around the system. 4. Pressure a. All pressure vessels are tested to 1.5 times the recommended working pressure. When considering a specific site pressure requirement the pressure rating of the system components must also be considered. Such items as the tubing where the temperature and pressure relationship should be understood. Details are available on request. 5. Electrical Requirements a. Electrical requirements will be site specific set against the applicable local or National Standards. A Systems Application Form should be completed by the customer when ordering a system and this will indicate the electrical classification required. DECLARATION OF INCORPORATION This Mechanical Seal Support System must not be put into service until the relevant machinery into which it is incorporated has been declared to be in conformity with the provisions of the Machinery Directive. James F McKeever Managing Director, AESSEAL (MCK) Ltd. Copyright 2004 All Rights Reserved

INSTALLING & COMMISSIONING A SYSTEM Page 2 of 6 PRESSURE EQUIPMENT DIRECTIVE COMPLIANT Copyright 2004 All Rights Reserved

TYPICAL DUTIES General Purpose Condensate System GENERAL SPECIFICATION Standard Equipment: Options: High Performance Condensate System, which should be connected directly to a suitable Condensate Pump Discharge Port to form a low maintenance, high reliability barrier fluid support system. In normal operation the pump pressurises the vessel, but negligible water is drawn. The thermosyphon effect (natural convection) ensures that the seal is kept cool. In the meantime the integrity of the barrier is maintained to extend seal life and prevent any loss of product. Vessel Fill Valve Pump Discharge Connection Valve Thermal Relief Valve Level Gauge 3-Way Ball Valve Drain Valve Finned Tubing Stainless Steel Hose Kit Page 3 of 6 CS3 coding: M7 VAS/CONDES-15 Literature: Price List Ref: n/a Current issue in the Systems folder in the In-Use Directory Availability: 2-4 weeks from placement of order TECHNICAL FEATURES Vessel: Material: Finish: Capacity: Pressure Ratings: In accordance with ASME VIII Div 1 rules. All Welders to have current WPQR s coded to ASME XI. All pressure welds to have current supporting PQR s. 316 Stainless Steel body Glass Bead Blast finish 15 litre (4 US Gallons) nominal capacity Maximum working pressure 30 bar(g) @ 200 C (435 PSI @ 392 F) Vessel tested to 45 bar(g) (650 PSI) Connections: Top Port 1 NPT Pump Discharge Connection Port Fill Valve Port Vessel Drain Port Seal feed line Port Seal riser line port 2 x Instrument Connection Ports 2 x Level Switch Connection Ports ¾ NPT Copyright 2004 All Rights Reserved

Fill Valve / Pump Discharge Connection Valve / Drain Valve: Allow the filling of the vessel with liquid, attachment of the vessel to the discharge port of the pump and drainage of fluid. Stainless Steel Connection: Thermal Relief Valve: (F) Connection: Level Gauge: 3 Way Ball Valve: Connections: Finned Tubing: Allows discharge of the hottest water in the vessel to drain, should the liquid temperature and vessel pressure exceed the desired amount. This should be set at 2 bar(g) above the pump discharge pressure. Stainless Steel (F) Drain Connection Weld Pad Style, allows the viewing of liquid level within the vessel. Mild Steel (Painted), Stainless Steel Option Available Allows air to escape from the seal during filling, then is manually closed to prevent fluid loss. Allows sampling of the barrier fluid within the vessel and allows flushing of the seal faces if required. Stainless Steel (F) Improves heat transfer of the hot water to the colder environment by way of increasing the surface area of the supply and return tubing. Each length (997mm / 39.25 ) has a surface area of 0.5m 2. Cupro Nickel Tube with Copper Finns Page 4 of 6 INSTALLATION & COMMISSIONING Copyright 2004 All Rights Reserved

When correctly installed, a thermosyphon barrier fluid system is simple, effective and highly reliable. These guidelines will help ensure trouble free installation and operation. Pipework: Always use piping which has an inner diameter of at least 3/8 (10mm). Fittings: Do not use fittings with overly restricted bores. If finned tubing is being used, please note that this may be cut, bent and prepared just as ordinary tubing is. In the case where a 28 litre vessel and finned tubing is being used, a taller stand is available on request. Vessel Mounting: Please ensure that the system is mounted to a bracket/stand which is not subject to vibration. The System should be suitably mounted in a position where the pipe lengths and runs fall in line with those recommended in the drawing below. This will ensure that optimum thermosyphon action will take place. Page 5 of 6 On vertical pumps, there is a danger that when the system is filled a pocket of air may be trapped in the seal. When this happens, the outboard seal faces will run dry and may be irreversibly damaged. To prevent this, it is advisable to vent the outboard faces. This can easily be done on most seals by gently lifting the outboard rotary from the stationary. You will hear the air escape and then you will see barrier fluid appear. At this point ease the faces back. Copyright 2004 All Rights Reserved

Return pipe run: The riser (hot) pipe MUST NOT SAG. This cannot be overemphasised; the slightest sag can prevent flow. The pipe run must always go upwards. Priming the seal: Before connecting the vessel to the Pump Discharge Port, it is imperative that the vessel is filled with cold, clean water. The cold, clean water supply should be connected to the Fill Valve (1/2 NPT (F)) at the top of the vessel. At this stage, the Pump Discharge Connection should not be connected, and hence the valve may be opened to act as an air vent. During the fill stage, rotate the 3-way ball valve clockwise, and keep the valve in this position until water begins to emerge from the left hand port on the valve. At this point, rotate the 3-way ball valve anti-clockwise (counter-clockwise), and continue filling the vessel. When the fluid meniscus is around 10mm from the top of the sightglass, turn the cold, clean water supply off and close the Fill Valve. The Pump Discharge can now be connected to the Pump Discharge Connection Valve at the top of the vessel. Once this is achieved, open the Pump Discharge Connection Valve, and turn the pump on. Page 6 of 6 Direction of Flow: In an ideal system the ports on the seal should be vertical and the hot fluid will emerge from the uppermost seal connection, which is then piped to the return (side) connection on the reservoir. In practice the ports may end up being horizontal, but his should not pose a problem if the seal is correctly installed. When the system is first run, check the direction of flow i.e. which pipe gets hot. The hot pipe must go to the return (side) connection on the reservoir, or flow may cease after a short while. If the flow is the wrong way round, reverse the connections at seal or vessel. This is, of course, only valid where the ports are horizontal. If the ports are vertical, we would recommend that the seal is re-installed. It should be noted that even a slight concentric misalignment would cause the barrier fluid to flow in the opposite direction. Commissioning Checks: Check for and eliminate any leaks. Run the pump (or mixer etc.) and check which pipe gets hot. Reverse pipe connections if necessary on horizontal porting reset the seal on vertical porting. Run the system normally for several hours to reach equilibrium temperatures, periodically checking seal inlet and outlet temperatures. The riser temperature must not exceed 80 C (176 F), and also the feed/riser temperature difference should not exceed 25 C (45 F). If the riser temperature exceeds 80 C (176 F), it may become necessary fit a guard around the system to prevent personnel injury. Copyright 2004 All Rights Reserved