Portable Dosing Unit

Similar documents
Method Statement: Testing Dry Riser System

System Pressure Manager Standard & System Pressure Manager Plus

Disinfection procedure for water mains and services

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

Electronic Single and Twin Pump System Pressure Managers

Accu-Tab Systems 1000 Series by Axiall Corporation

Transferring and Storage

Technical Service Bulletin March 2015 TSB142.01

Contents. Foreword. Acknowledgements. General Introduction

Accu-Tab PowerBase 3012AT by Axiall Corporation

GENO -Flushing Compressor Product Data Sheet F 02

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

ph monitoring of the generated Chlorine Dioxide solution to ensure correct conditions for maximum conversion efficiency

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Accu-Tab Systems 2000 P Series by Axiall Corporation

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Prestige Water Equipment Ltd.

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

Waste Management System.

To plot the following performance characteristics; A pump is a device, which lifts water from a lower level to a higher

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22

1020 Industrial Drive, Orlinda, TN fax

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Ventam 85 Installation & Commissioning Instructions

Prestige Water Equipment Ltd.

matrix installation guide

DIVER COMMUNICATIONS: DIVE PANEL: EMERGENCY BREATHING APPARATUS: DIMENSIONS: ANALYSIS: ACCESS: DECK & VESSEL COMMUNICATIONS: GAS PIPEWORK:

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

Water Hygiene Chlorination Water Treatment Legionella Control

Self-supporting hot water high pressure cleaner on trailer Hudson 315

OWNER S MANUAL NMB SERIES

Associated Hazard (outcome) Control Measures. Reduction of water supply

Workhorse-15 Oxygen Generator

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

HOT WATER HIGH PRESSURE WASHER ON TRAILER YUKON 315

DECLARATION OF INCORPORATION

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

CHE Well Testing Package/Service:

Information required for a pump quotation

Washdown Hygiene & Cleaning Equipment

Design Requirements for Eyewash and Safety Shower Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Section GAS CHLORINATION SYSTEM

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Accu-Tab PowerBase 3070AT by Axiall Corporation

REGISTRATION EXAMINATION, JUNE 2015 CERTIFYING PLUMBER ANSWER SCHEDULE

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

PHYSICAL FACILITIES Consultant s Handbook Division 33 Utilities 1300 Disinfecting Underground Potable Water Piping.

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007

Flamco Flamco-Fill STA Flamco-Fill STM

MEDICAL EQUIPMENT CATALOG

Hot Water Stationary Unit

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

BOSS PULISCI PROVA IMPIANTI MEDIA

Introduction. Part one: Identify the Hydraulic Trainer Components

Spirax Compact FREME Flash Recovery Energy Management Equipment

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Dräger PAS AirPack 2 Compressed Air Breathing Apparatus

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Summary of the MRA LPG Codes of Practice

Portable Electric Desalinator Operation Manual Rainman Desalination

Chesil - Electronic Pressurisation Unit

Apparatus Operator/Pumper

GROUTEC SCOTT VICKERS. Grouting Equipment

LEADERS IN HYGIENE TECHNOLOGY. Washdown Hygiene & Cleaning Equipment

LEADERS IN HYGIENE TECHNOLOGY

FlowSol B / B HE * * Manual for the specialised craftsman. Installation Operation Commissioning

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Air Plus User Manual

The Refurbishment of Filtration & Chemicalisation Systems On A Recent Project

Installation and commissioning instructions 255 series and 256 series

CAPITAL CONTROLS SERIES NXT3000

Installation Instructions for NP100 Series Nitrogen Control Panels

GRUNDFOS INSTRUCTIONS. PM Rain. Installation and operating instructions

APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Chapter 14 Water Shuttle Operations

Siphon vessel / Priming aid

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

FLOWMETERING STORAGE TANKS FROM THE INSIDE

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Accu-Tab PowerBase 3140AT by Axiall Corporation

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

INSTALLATION AND SERVICE MANUAL FOR LANCER DISPENSING TOWERS

PREVENTION OF EXCESSIVE PRESSURE DURING FILLING OF CRYOGENIC VESSELS

Expansion Vessels for Potable Installations

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

SELECT PUREWATER 300

A little technical and safety...

Crest Heating Boilers FBN(L) Series &

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

Transcription:

Portable Dosing Unit The purpose of this project is to provide trailer mounted portable hypochlorite dosing units that can be used on Melbourne Water mains where mains pressures are less than 100 MWG or on water storages. The primary function of these units is to perform emergency dosing of a water main or tank following a failure in the existing disinfection process. Another possible use for these units includes the super-chlorination of a water main or water tank following remedial or new works. These units are designed with a maximum storage capacity of 400 litres of 12.5% sodium hypochlorite. JONOCO Pty Ltd were responsible for the design, manufacture and supply of trailer mounted (mobile) disinfection units to meet the necessary requirements. These units are designed for a theoretical operational life of 10 years. Photo 1 Portable Dosing Unit (PDU) This unit is based on a purpose built 2.1m x 1.5m twin axle trailer with lockable canopy housing both sodium hypochlorite and potable water storage and delivery systems. The canopy has sides hinged from the top for easy access while rear doors are hinged on the sides with fitted stays. Two small roof mounted rotating cowls are provided on trailer canopy over the sodium hypochlorite area to help in the ventilation of the trailer.

Photo 2 Sodium Hypochlorite Dosing System. This system consists of Transfer Pump, Transfer Hose, 400Litre Storage Tank, two Chemical Dosing Pumps (one large and one small) Flow-meters, Pressure Relief Valves and Dosing Hose. Transfer Pump is used to transfer sodium hypochlorite to and from storage tank via valve selection. Transfer Hose is a 10 metre long 40mm braided hose to assist in the transfer of sodium hypochlorite. The 400 litre storage tank is fabricated from translucent HDPE for storage of sodium hypochlorite. Photo 3 Transfer Pump

Photo 4 Flow Indicators and Pressure Relief Valves Photo 5 Dosing Pumps Two Chemical Dosing Pumps are used in the delivery of sodium hypochlorite to the water main, tanks or reservoirs. Depending on what dosing rate is required is what chemical dosing pump is used. To confirm the amount of sodium hypochlorite that is used a flowmeter (Rotameter) has been fitted to each pump. This flowmeter provides the operator with a visual indication of the set flow rate of the dosing pump. Also on the discharge of each pump is a pressure relief valve. This relief valve ensures the over pressurisation of the pipe-work does not occur. Photo 6 Potable Water System Potable Water System consists of delivery pump, pressure vessel, pressure switch, storage tank, valve and pipework, emergency eye/face wash unit and retractable hose

Photo 7 Potable Water Delivery Pump Photo 8 Potable Water Storage Tank The delivery pump is used to delivery potable water to the ancillary equipment of the PDU. This is controlled by a pressure switch set to 28MWG. A 240 Litre storage tanks is fabricated from translucent HDPE for the potable water. Photo 9 - Emergency Eye/Face Wash Unit in deployed position. (Insert) Unit in stored or travel position. (Insert) Retractable Hose unit Potable water is provided from the storage tank to the unit via the potable water delivery pump/pressure vessel system. Retractable hose is provided to facilitates the wash down and flushing of equipment.

Photo 10 Onboard Petrol Generator. (Insert) Generator Control Panel All of the Portable Dosing Unit equipment is 240 VAC supplied. This can be supplied via the on-board petrol generator where electrical supply is not available. An electrical appliance inlet socket on the front of the trailer allows for the connection of electrical supply from either the trailer or any other source of 240 VAC, 50HZ supply. For further information please contact: Mr Noel McKay 03 9540 0311 Mobile 0418 592 754 Mr David Poloni 03 9384 0020 Mobile 0438 008 039