WATER - JACKETED CO 2 INCUBATORS

Similar documents
Water jacket CO Incubators 3503/3517/3524

PERFORM Operating Document

PERFORM Operating Document

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Model 130M Pneumatic Controller

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

RAM 4021 Operation Manual

Rejuvenation Instructions

with O 2 Controller Instruction Manual

RAM 4021-DPX Operation Manual

Digital Melting Point Apparatus

UsER manual for Watersens ph -REDOX

R E D I C O N T R O L S

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

FAULT CODE TROUBLESHOOTING INDEX

Installation of Your SprayMaster System

Installation and Use Manual

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

CSA Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Float Operated Level Controllers

FX134, FX1234, FX3030 Problem and Solutions

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Operating Instructions Part No

200 PSI HIGH-FLOW AIR SOURCE KIT

Installation, Operation, and Maintenance Manual

Propane Conversion Kit Instructions

256 Pneumatic Pressure Indicator

Operator: Save these instructions for future use!

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INSTALLATION GUIDE Gas Rangetops

200 PSI FAST-FILL AIR SOURCE KIT

36H SERIES Combination Gas Valve

Universal Valve Company Inc

Temperature Controllers

RC 195 Receiver-Controller

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

400C & 450C DUAL PERFORMANCE VALUE PACKS

Powers Controls RC 195 Multiple Input Receiver- Controller

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

444C DUAL PERFORMANCE VALUE PACK

NIV EAU MATIC ST User Manual Made in Canada

1020 Industrial Drive, Orlinda, TN fax

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Operating Instructions Part No

Aquavar SOLO 2 Frequently Asked Questions

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 2300 Units

Universal Valve Company Inc

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

accidents which arise due to non-observance of these instructions and the safety information herein.

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Pressure Injection Cell Operator s Manual

Model: 43T. Bermad Pressure Relief Valve

USER S INFORMATION MANUAL

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Reverse Osmosis System Installation Guide and Operation Manual.

Air Plus User Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Budget Range Operators Handbook

Operator: Save these instructions for future use!

Pressure Dump Valve Service Kit for Series 3000 Units

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Conversion instructions from natural gas to propane

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

5 Channel Calibrator

Instructions for High Altitude Conversion

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

6 & 8 Bubble Panel Installation Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

Technical

IMPORTANT SAFETY INSTRUCTIONS

User Manual GRI- 1500Li

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

Vapotherm Q50 Compressor. Instructions for Use

Instruction Manual Recovery Station

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Operator: Save these instructions for future use!

The Univentor 1250 Anaesthesia Unit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Transcription:

WATER - JACKETED CO 2 INCUBATORS MODELS: 39200-10, 39200-15 INSTALLATION AND OPERATION MANUAL Cole-Parmer Instruments 625 East Bunker Court Vernon Hills, IL 60061 Phone (847) 549-7600 Fax (847) 549-7676

TABLE OF CONTENTS SECTION 1.0 RECEIVING AND INSPECTION SECTION 2.0 INSTALLATION SECTION 3.0 CONTROL PANEL OVERVIEW SECTION 4.0 OPERATION SECTION 5.0 FYRITE READING SECTION 6.0 MAINTENANCE SECTION 7.0 TROUBLESHOOTING SECTION 8.0 PARTS LIST UNIT SPECIFICATIONS SCHEMATICS REV 6/99 #4861324 These units are CO2 Water Jacketed incubators for professional, industrial or educational use where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. These units are not intended for hazardous or household locations or use. 2

1Section RECEIVING AND INSPECTION IMPORTANT: READ THIS MANUAL IMMEDIATELY Your satisfaction and safety require a complete understanding of this unit, including its proper function and operational characteristics. Be sure operators are given adequate training before attempting to put the unit in service. Note: This equipment must be used only for its intended application; any alterations or modifications will void your warranty. 1.1 Inspection: The carrier, when accepting shipment, also accepts responsibility for safe delivery and is liable for loss or damage claims. On delivery, inspect for visible exterior damage, note and describe on the freight bill any damage found, and enter your claim on the form supplied by the carrier. 1.2 Inspect for concealed loss or damage on the unit itself, both interior and exterior. If any, the carrier will arrange for official inspection to substantiate your claim. 1.3 Return Shipment: Save the shipping crate until you are sure all is well. If for any reason you must return the unit, contact your Cole Parmer representative for authorization. Supply nameplate data, including model number and serial number. Please see the manual cover for information on where to contact Cole Parmer. 1.4 Accessories: Make sure all of the equipment indicated on the packing slip is included with the unit. Carefully check all packaging before discarding. Each unit is equipped with 6 shelves, 2 shelf stands, 4 leveling feet, 1 humidity pan, 1 supply hose kit and 1 power cord. 3

2Section INSTALLATION Local city, county, or other ordinances may govern the use of this equipment. If you have any questions about local requirements, please contact the appropriate local agency. Installation may be performed by the end user. Under normal circumstances this unit is intended for use indoors, at room temperatures between 5 and 40 C, at no greater than 80% relative Humidity (at 25 C) and with a supply voltage that does not vary by more than 10%. Customer service should be contacted for operating conditions outside of these limits. 2.1 Power Source: The power supply must be properly grounded (earthed) and correctly sized to match the unit data plate rating. The supply voltage must match the data plate voltage within +/- 10%. These units are intended for 50/60HZ application. If supplied with a detachable cord set, plug the female end into the inlet on the unit and the male plug into the supply. Assure that units requiring a fuse have a fuse installed. This fuse may be at the inlet or a part of the cord set male plug. 2.2 Location: Select a site for the incubator with consideration for conditions which may effect performance, such as heat from radiators, ovens, autoclaves, etc. Avoid direct sun, fast moving air currents, heating/cooling ducts, and high-traffic areas. To ensure air circulation around the unit, allow a minimum of 5cm between the incubator and any walls or partitions which might obstruct free air flow. 2.3 Lifting / Handling: These units are heavy and care should be taken to use appropriate lifting devices that are sufficiently rated for these loads. Units should only be lifted from their bottom surfaces. Doors, handles and knobs are not adequate for lifting or transport. All moving parts, such as shelves and trays should be removed and doors need to be positively locked in the closed position during transfer to prevent shifting and damage. 2.4 Leveling: The unit must sit level and solidly. Leveling feet are supplied, and are to be installed in the holes in the base of the unit. Turn them counterclockwise to raise the level. If the unit must be moved, turn the leveling feet in all the way to prevent damage. CAUTION: Position and level incubator before filling the water jacket. 2.5 Filling and Draining: Turn the power switch to the I/On position. The front 4

panel has a WATER JACKET LOW warning light. Fill the water jacket with DISTILLED WATER ONLY through the filling port at the back labeled FILL W/J HERE. Stop filling when the warning light goes off. The jacket holds approximately sixteen and a half (16.5) gallons; DO NOT over-fill the water jacket. To drain the water jacket, attach siphon hose to siphon tube adjacent to fill port marked SIPHON HERE. Start a siphon and allow the unit to empty into a suitable service drain or catchment area. 2.6 Cleaning: The unit chamber should be cleaned and disinfected prior to use. Your operating conditions and appropriate protocol will determine the correct procedure for decontamination. A typical decontamination procedure that is adequate for many situations has been described below. As well, certain steps are listed that will help reduce the likelihood of contamination and the necessity of decontamination. Whatever process is appropriate, it needs to be done on a regularly scheduled basis. Depending on usage and protocol, this may be monthly, quarterly or otherwise. Regardless of the decontamination procedure used, certain precautions will need to be taken: A. Always disconnect the unit from the electrical service when cleaning. Assure all volatile or flammable cleaners are evaporated and dry before reconnecting the unit to the power supply. B. Special care should be taken when cleaning around sensing heads to prevent damage. C. If you use chlorine-based bleaches or abrasive cleaners this will modify the stainless steel interior finish. DO NOT USE hard tools such as metal wire brushes or steel wool. Use non-abrasive cleaners and soft tools such as plastic brushes. D. Use only DISTILLED water in the water jacket and the humidity pan. DO NOT USE de-ionized water due to its reactivity with metal components. TYPICAL DECONTAMINATION PROCEDURE 1. Remove the humidity pan every week and autoclave, or wash with soap and water then disinfect with 70% alcohol solution. Replace in the incubator with fresh, DISTILLED water. 2. Flush the sample port tubing with 70% alcohol solution. Replace any lines that have a green color. 3. Remove the door gaskets, clean and disinfect. Clean and disinfect all mounting grooves for the door gaskets. 5

4. Remove all shelves, shelf supports, shelf standards and shields. Autoclave, or wash and disinfect as described in item 1. 5. Wash and disinfect all interior surfaces. 6. Give special attention to cleaning and disinfecting all access ports, air bleeds, shaft holes, electrical pass-throughs and any other passages into the chamber. 7. Replace all air and CO2 filters every six months or when noticeably dirty on the upstream side. CO2 filters are located in the shadow box just behind the GAS IN fitting and in line with the CO2 tubing kit. Units with flow meters require operator- supplied air pumps. These pumps should be checked for proper air filtering. OPERATION FOR MINIMIZING CONTAMINATION 1. Keep the outside of the incubator, including the air in the laboratory, as clean as possible. This is particularly important for units placed directly on the floor. Do not place incubators near doors, air vents or other areas of high air movement or traffic. 2. The floor around the unit needs to be clean. Units that are placed on the floor should be mounted higher Ð typically on a caster platform Ð for ease of moving the unit during cleaning and access to the back of the unit. 3. Minimize the number of times access is made to the chamber during normal operation. 4. Do not depend on the use of antibiotics to maintain uncontaminated conditions, as this is an inadequate technique for sterilization. Preferably use aseptic techniques as described above for maintaining sterile conditions in the incubator. 2.7 Shelves and Interior Parts: Shelving supports and a humidity pan are supplied with each unit. See Figure 1 for proper placement of these accessories. 6

Figure 1 7

3Section CONTROLS OVERVIEW (See Figure Two) 3.1 Power Switch: The main power I/O (On/Off) switch on the panel controls all power to the incubator. It must be in the I/On position before any systems are operational. The POWER ON light indicates power to the unit. 3.2 Main Temperature Controller: Marked C, this controller contains the digital temperature display, UP and DOWN arrow pads, HIGH and LOW alarm indicators and an alarm MUTE indicator. A. Digital Temperature Display indicates the actual temperature within the incubator chamber to.1 C. B. UP and DOWN Arrow Pads are used for inputting the set point, calibrating the display and muting or unmuting the audible alarm. C. HIGH and LOW Alarm Indicator will light whenever there is an alarm condition associated with the temperature within the incubator. D. Alarm MUTE Indicator will light whenever the audible alarm has been muted. 3.3 Element Energized: This pilot lamp is on whenever the temperature controller is energizing the heating element. The element will go on and off when heat is needed to maintain the set point temperature. 3.4 High Limit Thermostat: Completely independent of the Main Temperature Controller, the High Limit Thermostat functions as an override control. If at any time the Main Temperature Control fails in the On position, the chamber temperature is then limited to the High Limit Thermostat set point which is approximately (but not limited to) 1 C above the Main Controllers set point. Note that the Element Energized indicator will continue to function under the control of the High Limit Thermostat. 3.5 Temperature High Limit: This pilot lamp is on whenever the High Limit Thermostat has taken control of the incubator and shut down the elements. Under normal operating conditions this pilot lamp should never be on. 8

NOTE: If the unit is being run on the High Limit Thermostat, the temperature stability of the unit will suffer. 3.6 CO2 Sample Port: Chamber atmosphere can be taken from the Sample Port on the control panel. CO2 concentration can then be checked using a Fyrite gas analyzer or other instrument such as a gas chromatograph. 3.7 Door Temperature Controller: Located inside the outer door. The Door Temperature Controller maintains temperature level of the door elements to minimize condensation on the inner glass door. It provides fast heat-up and temperature recovery after the door has been opened, and minimizes chance of contamination. 3.8 Door Element Energized: This pilot lamp is on whenever the door temperature controller is energizing the heating element. The element will go on and off as heat is needed to maintain the door temperature set point. 3.9 Water Jacket Low: This pilot lamp is on whenever the water level in the jacket is low indicating distilled water should be added. 3.10 CO2 Controller: Marked % CO2, this controller contains the digital CO2 display, UP and DOWN arrow pads, HIGH and LOW alarm indicators, and alarm mute indicators. A. Digital CO2 Display indicates the % CO2 content within the incubator chamber to.1%. B. UP and DOWN Arrow Pads are used for inputting the set point, calibrating the display and muting or unmuting the audible alarm. C. HIGH and LOW Alarm Indicators will light whenever there is an alarm condition associated with the CO2% within the incubator chamber. D. Alarm Mute Indicator will light whenever the audible alarm has been muted. 3.11 CO2 Injecting: This pilot lamp is on whenever the CO2 controller is injecting CO 2 into the incubator chamber. 3.12 Humidity Display: Marked % RH, this digital display shows the relative humidity within the chamber in whole percents. Figure 2 9

4Section OPERATION READ THIS SECTION IN ITS ENTIRETY BEFORE ATTEMPTING OPERATION IMPORTANT: In order to assure the proper operation of this incubator, it is essential that you regularly verify the accuracy of the temperature and CO2 controls. Temperature can be confirmed by use of a thermometer inside of the chamber. CO2 can be confirmed with the use of a Fyrite Gas Analyzer or other equipment such as a gas chromatograph. These must be checked at least on a weekly basis. Any questions should be directed to a technical service representative. 4.1 Power Source: Connect service cord to grounded outlet; attach female end of the cordset into the fused and recessed male plug at the back of the unit and the male plug end of the cordset into the building supply. NOTE: Fill water jacket (See 2.5) and set temperature before connecting CO2 supply to the incubator. 4.2 Humidity: Humidification of the incubator is achieved by the evaporation of water from the chamber reservoir in the bottom of the incubator. Fill the stainless steel pan supplied with DISTILLED WATER ONLY and place it on the floor of the chamber to achieve near saturation humidity. For a quicker recovery of humidity, as well as higher humidity levels, use a pan with the largest possible surface area. Stainless steel is the best choice for a humidity pan, do not use plastic, glass, or any other metal. Do not use corrosive chemicals such as copper sulfate or chlorine. Such chemicals should never be placed directly in bottom of chamber. The use of disinfecting chemicals within the humidity pan is not recommended because they can change the humidity by changing surface tension of the water and inhibiting cell culture growth. Water in the pan should be changed at least once a week to help control contamination and to maintain proper evaporation. Do not use tap water or deionized water to refill the humidity pan. Use Distilled Water only for this purpose. 4.3 Turn the High Limit Thermostat to its maximum position, clockwise. 4.4 Setting Main Temperature Controller: An accurate reference thermometer should be used inside the chamber when setting and calibrating the incubator temperature. Be certain that the thermometer can be easily viewed through the glass door and is not touching any shelves or chamber walls as this will give 10

an inaccurate reading. To set temperature on the control press either the UP or DOWN arrow pad until the digital display begins to blink from bright to dim. While blinking the display is showing the current set point which can be changed by pushing the UP and DOWN arrow pads until the desired value is reached. If no adjustments are made within five (5) seconds, the controller will default back to displaying the temperature within the chamber. Once set point is established allow 24 hours for the temperature to stabilize. 4.5 Calibrating Main Temperature Controller: During Main Temperature Calibration it is important that the inner glass door not be opened for any reason, the outer heated door be opened as little as possible and the temperature has been stabile at set point for several hours. Compare the reference thermometer with the digital display. If there is an unacceptable difference put the display into calibrate mode by pressing both the UP and DOWN arrow pads at the same time until the two outside decimal points begin to flash. While the decimal points are flashing the display can be changed to match the reference thermometer by pushing the UP or DOWN arrow pads. If no adjustments are made within five (5) seconds the display will default back to displaying the temperature in the chamber. After the display has restabilized and maintained set point for several hours, check the actual temperature again. If the reference thermometer does not match the display, repeat the calibration. 4.6 Setting Door Temperature Controller: The Door Temperature Control should initially be set at the 38 C guide mark and adjusted upward if necessary to eliminate condensation on the glass door. Note that the door temperature can be adjusted to keep condensation from forming, but cannot eliminate it once formed. Use a dry towel to wipe off the inner door before resetting the control. The door temperature should be 1 C to 1.5 C above the Main Temperature. You may wish to use a reference thermometer taped to the center of the door liner to aid in determining the temperature; if so, the thermometer must be read very quickly before it drops due to the cooler room temperature. Adjust the control as necessary and wait several hours before checking again. Do not set the door temperature too high or incubator uniformity will suffer and condensation will appear on the chamber walls. 4.7 Setting High Limit Thermostat: With the Main control calibrated and stabile at set point, the High Limit needs to be adjusted. Previously turned to its maximum position as stated in section 4.3, now turn the control knob counterclockwise just until the TEMPERATURE HIGH LIMIT indicator light comes on. Next, turn the control knob clockwise just until the indicator light goes off. Then turn the control knob clockwise two (2) of the smallest divisions on its scale past the point where the indicator light went off. This will adjust the High Limit set point to approximately 1 C above the Main Temperature Control set point. It is recommended that the High Limit set point be checked periodically to assure no changes have occurred. A mark on the dial will aid for 11

future reference if changes to this set point occur. 4.8 Temperature Alarms: The Main Temperature Control has visual/audible alarm indicators for HIGH and LOW conditions that are activated whenever the actual temperature is 1 C above or below the set point. There is a built in delay of fifteen (15) minutes on the occurrence of the audible LOW alarm. This prevents the alarm from activating every time the door is opened and the temperature drops. 4.9 Muting Audible Alarm: The audible alarms can be muted for a single alarm occurrence by pressing and holding down either the UP or DOWN arrow pad for several seconds until the alarm is muted and the MUTE indicator comes on. This means the alarm is muted for that particular condition while it exists, but is not muted indefinitely or for a separate condition that may occur. 4.10 CO2 Supply: As stated in section 4.1, do not connect the CO2 supply to the incubator until the Temperatures have been set. Use only medical grade CO2 with an in-line filter from the tank to the incubator. These incubators use CO2 in small quantities. Precise metering of input is vital for maximum performance and only a two-stage CO2 pressure regulator is recommended. Note that some single-stage CO2 pressure regulators have two (2) gauges, be certain you are using only a two-stage regulator. 4.11 CO2 Regulator: It is highly recommended that a good quality DUAL STAGE pressure regulator be used on the CO2 tank. The high-pressure stage of the regulator coming direct from the supply tank must have a range from 0 to at least 2000 PSI (actual tank pressure as read on the gauge). The low-pressure stage should have a range from 0 to at least 40 PSI. The low-pressure gauge indicates actual CO2 pressure into the incubator. Connect the CO2 supply from the low-pressure stage of the regulator to the 3/8" inlet fitting at the back of the unit above the cord inlet. CAUTION: CO2 pressure to the incubator inlet is rated from 5 to 40 PSI. DO NOT exceed 40 PSI. 4.12 CO2 Principle of Operation: The microprocessor CO2 control system interprets the information from the CO2 sensor, displays the CO2 concentration directly on the digital display, reads the set point and controls the percentage of CO2 in the incubator chamber. The Thermal Conductivity (TC) sensor operates under the principle that CO2 is 1.5 times more dense than air and if you measure the changes in density they can be interpreted as changes in CO2 content. This method of measurement is accurate, reliable and stable as long as all factors that influence density are maintained unchanging. Other factors that effect density are humidity and temperature. When the door of the incubator is opened, the humidity is reduced, the temperature is lowered and the TC control system loses stability until the conditions in the incubator chamber have 12

recovered to original conditions. 4.13 Setting CO2 Controller: To set the CO2 percent you desire press either the UP or DOWN arrow pad until the digital display begins to blink from bright to dim. While blinking, the display is showing the current set point which can be changed by pushing the UP and DOWN arrow pads until the desired value is reached. If no adjustments are made within five (5) seconds, the controller will default back to displaying the parameter within the chamber. Once set point is established allow several hours for CO2 to stabilize. 4.14 Calibrating CO 2 Controller: During CO2 calibration it is important that the inner door not be opened for any reason and the CO2 has been stabile for several hours. Using a Fyrite gas analyzer, measure the actual CO2% within the chamber via the sample port on the control panel. (For Fyrite reading instructions see Section 5.0.) If there is an unacceptable difference between the display and the Fyrite put the display into calibration mode by pressing both the UP and DOWN arrow pads at the same time until the decimal points begin to flash. While the decimal points are flashing the display can be changed to match the Fyrite by pushing the UP or DOWN arrow pads. If no adjustments are made within five (5) seconds the display will default back to displaying the CO2% in the chamber. After the display has restabilized and maintained set point for several hours, check the actual CO2% again. If the Fyrite does not match the display, repeat the calibration. NOTE: When using the Fyrite, insure that gas is not being injected while the reading is being taken. Change the CO2 set point to 0.0 prior to taking the sample and change the set point back to the desired value after the use of the Fyrite is finished. 4.15 It is recommended that the accuracy of your CO2 control system be monitored by measuring the actual CO2 concentration on a weekly basis with a Fyrite or other measuring device. This should be done when the chamber has not been disturbed for an extended period of time i.e. after the weekend, or first thing on Monday morning. 4.16 CO2 Alarms: The CO2 controller has visual/audible alarm indicators for HIGH and LOW conditions that are activated whenever the actual CO2 content is 1% above or below the set point. There is a built in delay of fifteen (15) minutes on the occurrence of the LOW audible alarm. This prevents the alarm from activating every time the door is opened and the CO2 content drops. See Section 4.9 for MUTING the audible alarm. 13

5Section FYRITE READING NOTE: Be sure to hold canister away from face. Do not press button with canister inverted. 1. Press button on top of Fyrite canister to release CO2 concentration. Tip canister to the side to ensure all fluid is released from top of canister. 2. Loosen screw on slide scale and align top of fluid with zero on the scale. Tighten screw. 3. Connect hose and bulb to unit being tested. 4. Place hose directly over button on top of canister and press firmly. 5. With button depressed, squeeze bulb 27 times. On the last squeeze, and with bulb still deflated, release hose from button. 6. Turn Fyrite canister upside down 3 times, each time allowing all fluid to flow to the opposite end of the canister. 7. Tip canister slightly to ensure all fluid has been released from top of canister. 8. Read CO 2 concentration in %. To ensure accuracy, it is important to always follow the same procedure when taking a Fyrite reading. 14

6Section MAINTENANCE NOTE: Prior to any maintenance or service on this unit, disconnect service cord from the power supply. 6.1 Disinfect the incubator interior and remove and clean shelves and shelf slides on a regular basis. Please review the cleaning procedures described in the Installation section for detailed instructions. 6.2 Periodically check CO2 supply lines and connections for leaks. Use a liquid soap solution and wet supply line and connections to detect leaks. Look for bubbles. 6.3 Keep the CO2 flow system free from impurities. Erratic CO2 control is usually traceable to the CO2 pressure regulator on the tank, impurities in the tank, or impurities in the solenoid valve. Replace the CO2 in-line filter every six (6) months or when the filter has become noticeably dirty on the upstream side. There is a CO2 filter attached to the supply hose kit and one inside the shadow box connected to the GAS-IN line. 6.4 Storage: If the incubator is turned off for any length of time, be it hours, days, or weeks, it may be reactivated by simply turning it on and allowing 24 hours for recovery. NO adjustment or recalibration is necessary. If it is shut down, open the door, remove the humidity pan and disconnect the gas supply. If this is not done, all the warm water will condense out on the interior of the incubator. Since the water will contain carbonic acid from the CO2, damage may occur. If incubator is shut down for storage or transporting, siphon water from jacket, remove humidity pan, remove shelves and shelf standards, turn off CO2 supply at tank, screw in leveling legs and disconnect the power supply. 15

7Section TROUBLESHOOTING Always make a visual inspection of the incubator and control console when troubleshooting. Look for loose or disconnected wires or tubing which may be the source of the trouble. If service or technical assistance is needed call the number located on the front of this manual. Temp-1 Temp-2 Temp-3 Temp-4 Temperature too high Display reads "HI" or "400"+ Chamber temp spikes over set point and then settles to set point Temperature too low TEMPERATURE 1/ controller set too high-see section 4.4 2/ controller failed on Ð call Customer Service 3/ wiring error Ð call Customer Service probe is unplugged, is broken or wire to sensor is broken Ð trace wire from display to probe; move wire and watch display to see intermittent problems recalibrate Ð see section 4.5 16

Temp-5 Temp-6 Temp-7 Display reads "LO" Unit will not heat over a temperature that is below set point 1/ High Limit too low Ð see section 4.7 2/ controller set too low Ð see section 4.4 3/ unit not recovered from door opening Ð wait for display to stop changing 4/ unit not recovered from power failure or being turned off Ð incubators will need 24 hours to warm up and stabilize 5/ element failure Ð see if element light is on; compare current draw to data plate 6/ controller failure Ð confirm with front panel lights that controller is calling for heat 7/ High Limit failure Ð confirm with front panel lights that it is operating correctly 8/ wiring problem Ð check all functions and compare wiring to diagram in section 8.0, especially around any areas recently worked on 9/ loose connection Ð check shadow box for loose connections 1/ sensor is plugged in backwards Ð reverse sensor wires to controller 2/ if ambient room temperature is lower than range of unit Ð compare set points and ambient temperature to rated specifications in section 8.0 1/ confirm that fan is moving and that amperage and voltage match data plate Ð check fan motor motion in shadow box and feel for air movement in chamber 2/ confirm that set point is set high enough,turn High Limit counterclockwise and see if element light or High Limit light comes on 3/ check connections to sensor 4/ check calibration Ð using independent certified reference thermometer, follow instructions in section 4.5 Unit will not heat up at all 17

Temp-8 Temp-9 Temp- 10 Indicated chamber temperature unstable Will not maintain set point Display and reference thermometer donõt match 1/ verify that controller is asking for heat by looking for element light Ð if pilot light is not on continuously during initial start up there is a problem with the controller 2/ check amperage Ð amperage should be virtually at maximum rated (data plate) amperage 3/ do all controller functions work? 4/ is the High Limit set high enough? Ð for diagnostics, should be fully clockwise with the pilot light never on 5/ has the fuse at inlet blown? 1/ ±0.1 may be normal 2/ is fan working? Ð verify movement of cooling fan in center of shadow box 3/ is ambient room temperature radically changing Ð either door opening or room airflow from heaters or air conditioning? Ð stabilize ambient conditions 4/ sensor miss-located, damaged, or wires may be damaged - check mounts for control and HIGH LIMIT sensors, then trace wires between sensors and controls 5/ calibration sensitivity Ð call Customer Service 6/ HIGH LIMIT set too low Ð be sure that HIGH LIMIT set point is more than 5 degrees over desired Main set point; check if HIGH LIMIT pilot is on continuously; turn controller knob completely clockwise to see if problem solved then follow instructions in section 4.7 for correct setting. 7/ electrical noise Ð remove nearby sources of RFI including motors, arcing relays or radio transmitters 8/ bad connection on temperature sensor or faulty sensor Ð check connectors for continuity and mechanical soundness while watching display for erratic behavior; check sensor and wiring for mechanical damage 9/ bad connections or faulty capacitor Ð check connectors for mechanical soundness and look for corrosion around terminals or signs of arcing or other visible deterioration 1/ assure that set point is at least 5 degrees over ambient room temperature 2/ see if ambient is fluctuating 18

Temp- 11 Temp- 12 Can't adjust set points or calibration Calibrated at one temperature, but not at another CO2-1 Overshoots set point but stabilizes CO2-2 Overshoots set point and continues to rise 1/ calibration error Ð see section 4.5 2/ temperature sensor failure Ð evaluate if pilot light is operating correctly 3/ controller failure Ð evaluate if pilot light is operating correctly 4/ allow at least two hours to stabilize 5/ verify that reference thermometer is certified 1/ turn entire unit off and on to reset 2/ if repeatedly happens, call Customer Service This can be a normal condition when operating temperature varies widely. For maximum accuracy, calibration should be done at or as close to the set point temperature. CO2 LEVEL 1/ turn set point up and down to see if solenoid valve works by feeling and listening to valve 2/ recalibrate with Fyrite, see section 4.14 and section 5.0 3/ fan not operating correctly a- fan motor stopped b- fan blade fell off c- wrong fan blade installed or mounted backwards 4/ wrong restrictor installed or missing altogether 5/ tank pressure too high, see section 4.11 6/ CO2 sensor partially plugged with dirt or condensation 7/ regulator set wrong, see section 4.11 8/ incubator too heavily loaded 9/ incubator being operated without shelving 10/ CO2 attached to sample port instead of ÒCO2 INÓ fitting 11/ if display and Fyrite does not match, see Troubleshooting CO2-5 19

CO2-3 Rises very slowly CO2-4 Never rises CO2-5 CO2-6 Display and Fyrite reading do not match Is unstable Ð display or actual reading varies around set point 1/ debris in solenoid causing it to leak continuously 2/ solenoid failed while open 3/ unit miss-wired 4/ CO2 sensor or interface failure 5/ CO2 sensor plugged by debris or condensation 1/ restrictor partially plugged 2/ filter overly dirty or partially plugged 3/ CO2 tank regulator set too low, see section 4.11 4/ hose kinked or leaking 5/ poor door seal 6/ CO2 tank contains mixed gas, not 100% medical grade CO2 1/ CO2 tank empty 2/ solenoid failed while closed 3/ restrictor plugged 4/ CO2 hose blockage 5/ CO2 filter plugged 6/ set point is at 0.0 and has not been reset. See section 4.13 and 4.14 7/ CO2 controller output failed while open 1/ calibration error Ð clear chamber for 12 hrs and confirm at Ò0Ó 2/ turn set point up and down to see if solenoid valve works by feeling and listening to valve 3/ if display is varying when doing Fyrite test check to see if CO2 is injecting at time of test. 4/ take voltage reading across sensor leads 0=0V and 20=1V 5/ assure that sensor is properly mounted 6/ DISPLAY LOWER THAN FYRITE: air leak around the CO2 sensor or the fan motor shaft 7/ DISPLAY HIGHER THAN FYRITE: leak in tube from sample port to chamber, verify with liquid soap solution 8/ DISPLAY HIGHER THAN FYRITE: Fyrite fluid worn out, replace fluid with Fyrite refill 9/ DISPLAY HIGHER THAN FYRITE: poor Fyrite sampling technique, see section 5.0 10/ DISPLAY HIGHER THAN FYRITE: defective Fyrite pump or tubing 11/ Co2 sensor, interface or controller failure 20

CO2-7 CO2-8 CO2-9 1/ confirm that fan is working 2/ check for air leak around Co2 sensor or fan motor shaft 3/ magnetic field interface 4/ door not sealing properly 5/ atmospheric pressure fluctuations 6/defective Fyrite pump or tubing 7/ Co2 entering chamber too quickly a- tank pressure too high b- regulator set wrong c- restrictor incorrect or missing 8/ electronic problem with CO2 sensor, interface or controller 9/ top of unit exposed to cold air drafts 10/ unit being operated without shadow box cover 11/ electrical interface Ð atmospheric or conducted 12/ incubator too heavily loaded CanÕt adjust set points or calibration Ð Òlocked upó 1/ turn unit off and on to reset processor in controller Feeding continuously or abnormally high CO2 usage 2/ if repeatedly happens, call Customer Service 1/ do decay test: if more than 1% decay in an hour check for leak: door gasket tightness, motor inlet to chamber, sensor and probe inlet to chamber 2/ check output signal from controller 3/ check solenoid valve for correct operation 4/ leak in plumbing including between regulator and CO2 tank 5/ door being opened too often WonÕt hold calibration Fyrite reading varies but display stable 1/ atmospheric pressure fluctuations 2/ top of unit exposed to cold air drafts 3/ unit being operated without shadow box cover in place 4/ condensation collecting on CO2 sensor 5/ CO2 sensor or interface failure 6/ unit incorrectly calibrated, see section 4.14 7/ taking Fyrite reading too soon after the door has been opened 8/ air leak around CO2 sensor mounting plate MECHANICAL 21

Mech-1 Mech-2 Mech-3 Mech-4 Door not sealing Motor doesn't move Motor makes noise Solenoid valve buzzing Other-1 Controller on at all times - "locked-up" Other-2 Front panel displays are all off Other-3 Unit or wall fuse/circuit breaker is blown Other-4 Unit will not turn on Other-5 Unit is smoking Ð Out of box 1/ check physical condition of gasket 2/ confirm that door latch pulls door in tightly 3/ assure that gasket is in original location 1/ if shaft spins freely: check connections to motor and check voltage to motor; 2/ if shaft rubs or is frozen, relieve binding and retest 1/ If noise is from the motor, tap the top of motor shaft with ball peen hammer. 2/ If the sound gets worse, tap the other end of the shaft - avoiding touching the fan blade. 3/ If there is no change, call Customer Service. 4/ If noise is from shaft or fan blade, realign shaft. After removing solenoid clean with alcohol for carbon build-up then blow out. Check valve seat or channels for contamination. Check CO2 filter and/or grade of CO2 used. If seat is worn, replace. OTHER 1/ turn unit off and on to reset 2/ if cannot change any condition on the front panel, call Customer Service 1/ Check for wire damage. 1/ check wall power source 2/ compare current draw and compare to specs on data plate 3/ see what other loads are on the wall circuit 1/ check wall power source 2/ check fuse/circuit breaker on unit or in wall 3/ see if unit is on, e.g., fan or heater, and just controller is off 4/ check all wiring connections, esp. around the on/off switch Put unit under vent and run at full power for one hour. 22

Other Ð6 Contamination in chamber 1/ see cleaning procedure in Installation section 2.0 2/ develop and follow Standard operating procedure for specific application; include definition of cleaning technique and maintenance schedule. NOTE: TEMPERATURE OF DOORS AND INTERIOR WALLS MUST BE EQUAL. The incubator is designed so that no internal electrical servicing should be required under normal conditions. If electrical servicing is necessary, it should be performed by qualified service personnel. an electrical schematic is provided. FOR PERSONAL SAFETY ALWAYS DISCONNECT THE POWER BEFORE SERVICING. 23

8Section PARTS LIST Description 120V 220V CO2 Controller 1750559 1750559 CO2 Filter 100199 100199 Door Element 103068 103068 Door Temperature Control 100001 100001 Float Switch, Water Jacket 210004 210004 Gasket, 7 feet 3450534 3450534 Glass Door 9520572 9520572 Heating Element 2350503 120071 High Limit Thermostat 100001 100001 Humidity Display 1750555 1750555 Humidity Sensor 4100500 4100500 I/O (On/Off) Switch X1000124 X1000124 Motor 4880508 4880507 Pilot Light - Green 4650527 4650527 Pilot Light - Red 101148 101148 Power Cord 104189 104192 Power Inlet w/filter and Fuse 104179 104179 Solenoid Valve 8600528 8600529 TC CO2 Sensor 120034 120034 Temperature Controller 1750557 1750558 24

UNIT SPECIFICATIONS Weight Shipping Net 39200-10 400 257 39200-15 400 257 Dimensions Exterior WxDxH (IN.) Interior WxDxH (IN.) 39200-10 26.5X25.25X39.75 20.5X20X28.25 39200-15 26.5X25.25X39.75 20.5X20X28.25 Capacity Cubic Feet 39200-10 6.7 39200-15 6.7 Temperature Range Uniformity Sensitivity 39200-10 Amb. +5 to 50 C + 0.2 C +0.1 C @ 37 C 39200-15 Amb. +5 to 50 C + 0.2 C +0.1 C @ 37 C CO2 Range Uniformity Sensitivity 39200-10 0 Ð 20% +0.1% @ 5% +0.1% 39200-15 0 Ð 20% +0.1% @ 5% +0.1% 25

WIRING DIAGRAM 26