Livewell/Baitwell Pumps. Livewell/Aerator

Similar documents
PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

INSTALLATION INSTRUCTIONS

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Flow Material Length. Weight GPM LPM. Style 3095

Compact Transfer Pump

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

444C DUAL PERFORMANCE VALUE PACK

Operating Instructions Models and Hydrostatic Test Pumps

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

400C & 450C DUAL PERFORMANCE VALUE PACKS

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

TECHNICAL ACCESSORIES

Standard Grout Header. Protected Pressure Gauge. High Pressure Gauge. In-Line Grout Header. Inline Protected Pressure Gauge

VERTICAL BLADDER TANK

200 PSI COMPRESSORS - MODEL NUMBERS

Operating Instructions Model and Hydrostatic Test Pump

100C Air Compressor Kit

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Operating Instructions Model and Hydrostatic Test Pump

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Full Range Pressure Compensating Variable Flow Control

HORIZONTAL BLADDER TANK

IMPORTANT SAFETY INSTRUCTIONS

KJ4000 Operating Instructions & Parts Manual NSN

Ultra Concentrate Dispensing System

TECHNICAL DATA. Trimpac 256a. October 31, 2013

2016 /17 Catalog. distributed exclusively throughout the U.S by

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

TECHNICAL DATA. Trimpac 244a. September 16, 2013

PRO SINK -R 1 and 2. Dilution system CONTENTS

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Page 1 of 12

National Marine Manufacturers Association

Installation of Your SprayMaster System

Nozzles and portable monitors

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Impeller Replacement -

DS06D,G Dial Set Pressure Regulating Valve

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

12 Impeller Replacement

Instruction Manual Updated 5/26/2009 Ver. 2.0

Marschalk Model # 94000

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES

NHR Powder Feed Hopper

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

TABLE OF CONTENTS. Solution Mixing...pg. 2 Components...pg. 3 Set-Up...pg. 4 Operation...pg. 5 Toubleshooting...pg. 6

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

Variable Area Flow Meters

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

Precision and Instrument Regulators 1/4" port size

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Valve with Integrated Pressure Regulator for medical OXYgen

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

S0300-BV-CAT-020 AIR COMPRESSOR SYSTEM, SUB SALV, 1150-CFM, 500-PSI. System - DS0130. System DS0130 7/8/2018 2:56:57 AM

Direct Operated Precision Regulator Modular Style. Standard Specifications

Electropneumatic Transducer (I/P) Installation, Operation and

1020 Industrial Drive, Orlinda, TN fax

TurboDraft Fire Eductor

TECHNICAL DATA CAUTION

Instruction Manual Updated 7/26/2011 Ver. 2.2

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Operating Instructions Models and Hydrostatic Test Pumps

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Section 1 Freshwater Systems Electric Pumps 06 Manual Pumps 1 1 Faucets 14 Showers 19 Transom Showers 20 Accessories 22

Installation and Use Manual

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

GTX. 1 of 9. The GTX scrubber s 2 recover drain and hose are larger than those on many other machines, making the GTX scrubber less likely to clog.

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Portable Oil Lube Air Compressors

CROSS REFERENCE PARTS LIST T & S

Laboratory Flowmeters

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Tigerloop Article. 1 of 8 11/22/ :33 AM. Tigerloop Article - As seen in Fuel Oil News Magazine. by Lindy Lindtveit

Precision Rotary Airlocks and Diverter Valves

LMU100/200 Series. Standard Specifications

DUAL 444C ONBOARD AIR SYSTEM

Ozone Stuff Album A Work in Progress. 03/09/2017 by J Tim Rainey DDS

vanishing water how to use the table: Choose the stream width Choose the stream length based on the gravel depth

Transcription:

Livewell/Baitwell Pumps 03 Livewell/Baitwell Pumps Livewell/Aerator 049

050 03 Livewell / Baitwell Pumps selection GUIDE Livewell / Baitwell Pumps Tournament Series Bronze Base Fitting Discharge Outlet 209B Bronze Base. Call for more information. 1600 (6054) 1¹/8 (29mm) discharge outlet Call for more information. Tournament Series Dual Port Fitting Discharge Outlet 209FDP Dual Port. Call for more information. 1600 (6054) 1¹/8 discharge outlet 1 Gentle- Oxygenator Fitting 255 Ideal for 25lbs (11kg) of bait. Call for more information. 700 (2650) Fish Box Evacuation Pump Fitting gpm (lpm) 50900-1000 model, fuse 10 amp. Gentle- Oxygenator 5 (19) 50900-1100 24 volt DC model, fuse 5 amp. 24 volt DC SK900 Service Kit. C Series Tournament Series Angled Inlet 401C ¾ fuse 2.5 amp. 500 (1893) 403C ¾ fuse 5 amp. 800 (3028) 405C 1¹/8 (29mm) discharge hose, fuse 6 amp. 1100 (3685) STC Series Tournament Series Straight Inlet 401STC ¾ (1.9cm) discharge hose, fuse 2.5 amp. 500 (1893) 403STC ¾ (1.9cm) discharge hose, fuse 5 amp. 800 (3028) 405STC 1¹/8 (2.9cm) discharge hose, fuse 6 amp. 1100 (3685) FC Series Tournament Series Seacock Inlet 401FC ¾ (1.9cm) discharge hose, fuse 2.5 amp. 500 (1893) 403FC ¾ (1.9cm) discharge hose, fuse 5 amp. 800 (3028) 405FC 1¹/8 (2.9cm) discharge hose, fuse 6 amp. 1100 (4162)

051 Cartridges Amps 45DR 45DR, fuse 2.5 amp. 500 (1893) 2.5 Amp 46DR 46DR, fuse 5 amp. 800 (3028) 5 Amp 47DR 47DR, fuse 6 amp. 1100 (4162) 6 Amp Rule Oxygenator Systems gph 250 Oxygenator System - ideal for 10lbs (5kg) of bait. 500 251 Oxygenator System - ideal for 25lbs (11kg) of bait. 800 252 Oxygenator System - ideal for 50lbs (23kg) of bait. 1100 Transom Mount Livewell Pumps 24TB 360 (1363) 25DTB 500 (1893) Mounted aerator pump with strainer base assembly. 20RTB 800 (3028) 27DTB 1100 (4162) 265 Bracket Only. Cartridges Original Pro- Series Livewell Pumps 25DR 500 (1893) 20RR Cartridge. 700 (2650) 27DR 1100 (4162) Selection Guide Livewell / Baitwell Pumps 03

052 03 Livewell / Baitwell Pumps INTRODUCTION Livewell / Baitwell Pumps The Livewell/Baitwell pumps are built on Rule s unsurpassed quality and leadership in pump design and technology. The innovative design includes many new and exciting features including: a quick, one hand push button motor cartridge removal system, patented rotatable base that allows you to position the discharge nozzle at any location and threaded nylon hose barb attachments which allow for various hose mounting options. Other features include a built-in dual port option, water-cooled housing and positive snap motor cartridge locking mechanism. Pumps are available in 500 GPH, 800 GPH and 1100 GPH, plus 1600 GPH non cartridge models, and are fitted for transom or seacock mounting options. Tips on selecting a Livewell Pump Always select a pump that will deliver enough water to replace Livewell water every 10 minutes. Bigger is not better too much pump capacity could lead to air locks. Mount the pump as low and close to the hull as possible. C series with 4 (102mm) angled pick up tube for thru hull applications. STC series with 4¾ (121mm) straight pick up tube for thru hull applications. FC series with 1 (25mm) pick up tube for seacock applications. Note: High speed water intake scoops can damage the pump and possibly flood the hull.

053 Head Height Capacity 0' 3.35' (1m) 6.7' (2m) Discharge output 500 GPH 500 (1895L) 340 (1286L) 100 (378L) ¾ 800 GPH 800 (3027L) 490 (1854L) 320 (1211L) ¾ 1100 GPH 1100 (4162L) 790 (2989L) 480 (1816L) 1¹/8 1600 GPH 1600 (6056L) 1200 (4542L) 760 (2876L) 1¹/8 1100 (4164) RM1100A - 12DC - Tournament Series Bronze Base 1600 G.P.H (6054 L.P.H.) Livewell Pump Tournament Series Dual Port 1600 G.P.H (6054 L.P.H.) Livewell Pump Designed for the toughest applications the Tournament Series pump is the highest capacity Livewell pump in today s market. Pump features a bronze base, Anti- Airlock feature, and a heavy duty long life motor. 1 (25mm) NPT female intake and 1¹/8 (29mm) discharge outlet.. 209B 1600 GPH (6054 LPH) Bronze Base. Discharge Outlet Fitting 1600 GPH (6054 LPH) 1¹/8 (29mm) discharge outlet Call for more information 1 (25mm) NPT female intake Engineered to withstand the rigors of tournament fishing the Tournament Series pump is the highest capacity Livewell pump in today s market. This model features a glass filled nylon dual port base for optional washdown pump connection, Anti- Airlock feature and a heavy duty long life motor. The pump has a 1 NPT female intake, 1¹/8 discharge outlet and a ½ NPT threaded port for washdown installation. 12 volt DC. Discharge Outlet Fitting 209FDP 1600 GPH (6054 LPH) Dual Port. 1600 GPH (6054 LPH) 1¹/8 discharge outlet Call for more inforrmation 1 NPT female intake Introduction Livewell / Baitwell Pumps 03

054 03 Livewell / Baitwell Pumps Gentle- Oxygenator Fish Box Evacuation Pump Designed with the patented infuser technology and a Gentle- directional discharge, the Rule Gentle- Oxygenator is the ideal system for keeping bait and catch alive and healthy. The patented infuser technology introduces air into the base of the Livewell pump through the air control centre producing millions of micro-fine bubbles. Because the bubbles are so small, they remain suspended in the water longer, providing more aeration to your delicate bait and catch. Designed to fit almost any custom tank. Kits come complete with a pump, directional discharge, intake strainer, hose and intake valve. The new fish box evacuation pump is perfect for emptying a fish box, easily passing debris such as bait residue, particles of ice and fish scales that is often left after a days fishing. Self-priming up to 10ft (3m). Capable of extensive dry running. Compact and simple design. Quiet running. Flexible Installation. Corrosion resistant parts. Complies with USCG 183.410 and ISO 8846 MARINE (Ignition Protection). ISO 8849 MARINE (Bilge Pump Standard). 255 700 GPH (2650 LPH) ideal for 25lbs (11kg) of bait. Fitting Size Weight 5 gpm (19 lpm) Connections for 1½ (38mm) and 1 (25mm) ID hose. 10.9 long x 6.1 wide x 4.4 high (27.7cm x 15.5cm x 11.1cm). 6lb (2.7kg). 12v DC -24v DC 1 (25mm) NPT female intake 50900-1000 model, fuse 10 amp. 50900-1100 24 volt DC model, fuse 5 amp. SK900 Service Kit.

055 C Series Tournament Series Angled Inlet For Thru-Hull Applications Angled 4 (102mm) Pickup Tube.. STC Series Tournament Series Straight Inlet For Thru-Hull Applications Straight 4¾ (121mm) Pickup Tube.. 401C 500 GPH (1893 LPH), ¾ fuse 2.5 amp. 403C 800 GPH (3028 LPH), ¾ fuse 5 amp. 405C 1100 GPH (3785 LPH), 1¹/8 (29mm) discharge hose, fuse 6 amp. 401STC 500 GPH (1893 LPH), ¾ fuse 2.5 amp. 403STC 800 GPH (3028 LPH), ¾ fuse 5 amp. 405STC 1100 GPH (3785 LPH), 1¹/8 (29mm) discharge hose, fuse 6 amp. FC Series Tournament Series Seacock Inlet For Seacock Applications Straight ¾ (19mm) Tube with Tapered Threads.. Cartridges Modules for all Tournament Series Aerator Pumps. Note Can't be used on the Pro Series 401FC 500 GPH (1893 LPH), ¾ fuse 2.5 amp. 403FC 800 GPH (3028 LPH), ¾ fuse 5 amp. 405FC 1100 GPH (4162 LPH), 1¹/8 (29mm) discharge hose, fuse 6 amp. 45DR 500 GPH (1893 LPH), fuse 2.5 amp. 46DR 800 GPH (3028 LPH), fuse 5 amp. 47DR* 1100 GPH (4162 LPH), fuse 6 amp. *47DR is only suitable for model no: 405C, 405STC & 405FC Livewell / Baitwell Pumps 03

056 03 Livewell / Baitwell Pumps Rule Oxygenator Systems High performance live-bait aerators keep bait and catch alive and healthy in a smaller amount of water. Air is infused with the water at the pump impeller, then millions of micro-fine bubbles are produced and sent gently out of the pump into the Livewell. Because the bubbles are so fine, they remain suspended in the water longer and more aeration is provided for your delicate bait and catch.. 250 500 GPH Oxygenator System - ideal for 10lbs (5kg) of bait. 251 800 GPH Oxygenator System - ideal for 25lbs (11kg) of bait. 252 1100 GPH Oxygenator System - ideal for 50lbs (23kg) of bait. Portable Aerator Kit Aerates from 5 to 30 gallons (19 to 113 liters) of water. The Rule 460 GPH (1741 LPH) pump attaches easily to any non-porous surface. 9 (229mm) long spray tube can be custom cut to fit into any container. A fully adjustable spray head increases or reduces flow of water. Foam filtration system keeps water sparkling clean. The kit also includes battery clips for easy attachment to your 12 volt power source.. 202K Transom Mount Livewell Pumps Rule introduces a lineup of Transom Mounted Aerator Pumps. This allows the fisherman to have professional aeration of his Livewell without the need to install a pump through the hull. The unique quickrelease pump with strainer base assembly snaps easily into the transom bracket provided. At the end of the day, the pump can be removed for storage. Pumps feature 6 (1.8m) wire leads.. 24TB 360 GPH (1363 LPH). 25DTB 3500 GPH (1893 LPH). 20RTB 800 GPH (3028 LPH). 27DTB 1100 GPH (4162 LPH). 265 Bracket Only.

057 Cartridges Original Pro-Series Livewell Pumps Replacement motor cartridges for Rule Cartridge Bilge pumps and Livewell/Aerator pumps.. Oxygenator Spray Head Rule s Oxygenator spray head sprays streams of water back into the livewell tank enriching the water with oxygen. Adjustable spray head allows you to increase or decrease flow of water. For use with ¾ (19mm) hose. Note Not to be used with tournamentseries 25DR Cartridge 500 gph (1893 lph). 20RR Cartridge 700 gph (2650 lph). 27DR Cartridge 1100 gph (4162 lph). 78 Variable Control Livewell Pump Debris Strainer The Variable Control Valve allows increases and decreases of flow with no damage at all to the pump. Range includes fully open flow to zero flow. The Livewell Pump Debris Strainer attaches directly to any pickup tubes on Rule Livewell Pumps. Filters out trash and debris which could clog pump. Stainless steel wire mesh, ¾ (19mm) female NPSM threads. 75 73 Livewell / Baitwell Pumps 03