Yujiro Kitaide 1, Naoki Maruyama 1, Masafumi Hirota 1, Yusuke Onishi 2, Toshiaki Tsuchiya 2

Similar documents
Investigation to Improve Efficiency of Transcritical R744 Two-Stage Vapor Compression Systems

A virtual EXV mass flow sensor for applications with two-phase flow inlet conditions

Experimental Analysis and CFD Simulation of Pressure Drop of Carbon Dioxide in Horizontal Micro Tube Heat Exchangers

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

CYCLE ANALYSIS OF LINEAR COMPRESSORS USING THREE- DIMENSIONAL CFD

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

Modeling and Testing of an Automobile AC Scroll Compressor, Part II: Model Validation

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

A Numerical Simulation of Fluid-Structure Interaction for Refrigerator Compressors Suction and Exhaust System Performance Analysis

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

TESTING AND ANALYZING ON P-V DIAGRAM OF CO 2 ROLLING PISTON EXPANDER

Transient Analyses In Relief Systems

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

MODELING OF THERMAL BEHAVIOR INSIDE A BUBBLE

ALICE SPD cooling system

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Ball Beating Lubrication in Refrigetation Compressors

Investigation of Suction Process of Scroll Compressors

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Compressors. Basic Classification and design overview

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

An Experimental Performance Study of Vortex Tube Refrigeration System

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

Investigation of failure in performance of linear compressor & its rectifications

Linear Compressor Suction Valve Optimization

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Performance Analysis of Centrifugal Compressor under Multiple Working Conditions Based on Time-weighted Average

Characterization and Performance Testing of Two- Stage Reciprocating Compressors using a Hot-Gas Load Stand with Carbon Dioxide

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Mass Split of Two-Phase-Flow

ENGINEERING FLUID MECHANICS

Experimental Investigation on the Operating Characteristics of a Semi-hermetic Twin Screw Refrigeration Compressor by means of p-v Diagram

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand

RESIDENTIAL WATER DISTRIBUTION

Gas-Liquid Flow Distributions in Multipass Channels with Vertical Upward Branches

SUPERMETRO - Super-High-Speed-Train in Low Pressure Tunnel

Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

Modification and experimental research on vortex tube

Tip Seal Behavior in Scroll Compressors

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Two-phase Flow Across Small Diameter Split U-type Junctions

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Scroll Compressor Performance With Oil Injection/Separation

A Chiller Control Algorithm for Multiple Variablespeed Centrifugal Compressors

Citation Journal of Thermal Science, 18(4),

Baffles and Traps Cryotrap

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components

Development of Large Capacity CO2 Scroll Compressor

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

An Experimental and Numerical Analysis of Refrigerant Flow Inside the Suction Muffler of Hermetic Reciprocating Compressor

Impact of major leakages on characteristics of a rotary vane expander for ORC

Figure 1 Schematic of opposing air bearing concept

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Increase in Evaporation Caused by Running Spa Jets swhim.com

B outflow. Outflow. B1 Introduction. introduction

Experiment of a new style oscillating water column device of wave energy converter

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

An innovative technology for Coriolis metering under entrained gas conditions

COMMERCIAL REFRIGERATION SYSTEMS WITH CO 2 AS REFRIGERANT

Characterization and Performance Testing of Natural Gas Compressors for Residential and Commercial Applications

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

Scroll Compressor Operating Envelope Considerations

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Flow transients in multiphase pipelines

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

Pressure Drop of Two-Phase Flow Through Horizontal Channel with Smooth Expansion

Capacity Modulation of Linear Compressor for Household Refrigerator

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

ADVANCES in NATURAL and APPLIED SCIENCES

Heat Pump Connections and Interior Piping

Study on Stress Analysis of Araldite HY-951 and CY-230 Bell Crank Lever using Photoelasticity and FEM

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 11, Issue 5 Ver. III (Sep- Oct. 2014), 91-96 Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion Valve applied to a Small Scale Refrigerant Cycle (art II: Experimental evaluation of pressure drop) Yujiro Kitaide 1, Naoki Maruyama 1, Masafumi Hirota 1, Yusuke Onishi 2, oshiaki suchiya 2 1 (Graduate School of Engineering, Mie University, su, Mie, Japan) 2 (Fuji Electric Co., Ltd., Yokkaichi, Mie, Japan) Abstract: he application of a new pulse driven-type electromagnetic control expansion valve to an R744 cycle is proposed and the characteristics of the valve are experimentally examined in this paper. First, the structure of the valve is simulated by elements such as ducts, a pin hole, a groove and an orifice. he pressure drops caused by each element that makes up a valve are estimated individually, and summed up to discern the total pressure drop. Especially, the influence of the machining tolerance is estimated because the parts that make up the valve are very fine. hen an experiment for the pressure drop measurement is conducted by constructing a refrigerator cycle. he experimental results are then compared to theoretically estimated results. Both results show similar tendencies of a similar order against the mass flow rate, even though a refrigerant has a very complicated gas-liquid two-phase fluid flow. he pressure drop can be controlled by an electromagnetic control valve for the designated range. As a result, it was shown that the pulse driven-type electromagnetic control expansion valve proposed in this paper can be applied to control the pressure drop in a way suitable for fulfilling cooling demand. Keywords: Electric expansion valve, Electromagnetic control, Refrigerator, ulse drive, CO 2 (R744) I. Introduction Low temperature heat, such as that applied to an air conditioning unit or a fridge, is obtained from a heat pump or refrigerator using a refrigerant cycle, even though other energy conversion systems such as thermoacoustic refrigerators with thermoacoustic engines have been proposed [1-5]. he cycle contains a refrigerant as a working fluid, but a majority of currently used refrigerants are harmful to the environment, including causing problems such as the greenhouse effect. Accordingly, a heat pump using CO 2 (R744) as a working fluid has been practically used in recent years. R744 is a natural refrigerant which has a lower impact on the greenhouse effect when compared to conventional artificial refrigerants. However, the electric consumption of the heat pump that uses R744 becomes higher than that of a conventional refrigerant cycle with an artificial refrigerant, because the refrigerant needs high compression pressure in the cycle. herefore, the development of an energy-conserving heat pump using R744 has been expected. he refrigerant cycle consists of a compressor, a condenser, a decompression device, an evaporator and a working fluid. A capillary tube or an expansion valve is generally employed as a decompression device. he optimum design and control of the elements that make up the system, such as electric expansion valves, which are suitable for operation conditions have been investigated [6]. he application of a new pulse driven-type electromagnetic control expansion valve to an R744 cycle is proposed, and the characteristics of the valve are theoretically evaluated [7]. An electromagnetic control expansion valve is experimentally examined in this paper. he valve can control the pressure drop of a refrigerant continuously from the liquid to the two-phase state appropriate to the desired level of cooling. he motion of the pressure control elements inside the valve is much quicker than those of conventional systems using stepping motors. It contributes to the optimum operation of the refrigerator. he R744 cycle has a higher decompression and lower volume flow rate than other conventional refrigerant cycles at equal system capacity. he decompression of the refrigerant is caused at a microchanel and an orifice inside a valve. he flow patterns of CO 2 passing through a microchanel or a short orifice are very complicated, because the fluid starts boiling and expands when it passes through these elements. he flow characteristics, especially for a pressure drop in a microchanel, have been examined in detail [8-16]. A pulse driven-type electromagnetic controlled expansion valve is one of the most promising pieces of decompression equipment for refrigerant cycles. In this paper, the application of the valve to an R744 cycle is proposed, and the characteristics of the valve are experimentally examined and compared to the theoretically obtained results for the future design of the valve. 91 age

Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion.. II. Experimental Apparatus and rocedure Figure 1 shows a schematic layout of the experimental apparatus employed in this experiment. he system consists of a compressor, a condenser, an electromagnetic control expansion valve as a test piece and an evaporator. he mass flow rate is measured by a Coriolis mass flow meter. he mass flow rate of the refrigerant is controlled by a compressor with an inverter. he mass flow rate of refrigerant is also influenced by the pressure drop of the expansion valve and the filling amount of the refrigerant to the circuit. he principal local pressures and temperatures are measured by semiconductor pressure transducers and thermocouples, respectively. hese pressures and temperatures are recorded by a multi-channel data logger. he schematic configuration and photo of the test section are shown in Fig. 2. he test section consists of a cylinder with a pin hole and a V-shaped groove, a plunger and an orifice. he plunger is moved upwards and downwards by a solenoid which is controlled by pulse signal. If the plunger moves to the upper position, it contacts the cylinder. Refrigerant passes through only a V-shaped groove and flows toward to the orifice, as shown in Fig. 2(a). On the other hand, the plunger also contacts the orifice when it moves to its lowest position. Refrigerant can not flow into the orifice and is stopped, even though the gap between cylinder and plunger becomes large in this case. During the movement of the plunger between the upper and lower positions, refrigerant passes through narrow paths with varying cross sections. he pressure drop can be controlled by the position of the plunger, and its position is controlled by pulse driven electromagnetic devices. Accordingly, the refrigerant sustains its pressure drop when it passes through the expansion valve. est section Mass flow meter Condenser ulse driven-type electromagnetic control expansion valve Compressor Controller Inverter Evaporator Figure 1 Schematic layout of experimental apparatus Cylinder in hole lunger Refrigerant Groove Orifice Body: od11.8 Cylinder: od4.76 x id3.0 V-shaped groove (inside) (a) Detail of valve (upper position of plunger) (b) hoto of test piece Figure 2 ulse driven-type electromagnetic control expansion valve R744 was used as the refrigerant. Inlet pressure, inlet temperature and directing outlet pressure, namely pressure drops are chosen based on the empirical conditions for a small scale CO 2 refrigerator. Figure 3 shows a part of the Mollier chart of R744. he red striped area shows the inlet pressure and temperature of R744 to the valve. he blue striped area shows the outlet condition of the R744. he temperature difference of the fluid between inlet and outlet is around 10 ºC, and the quality of the gas, x, becomes between 0<x<0.2. he mass flow rate is set based on empirical conditions. he inlet temperature of R744 to the valve is controlled by the cooling amount of the condenser. And the inlet pressure and mass flow rates are controlled by the filling amount of refrigerant and the compressor which is operated by an inverter control. he position of the plunger shown in Fig. 2(a) is fixed at the upper position in this experiment. Accordingly, the characteristics of the pressure drop caused by the V-shaped groove, rapid-contraction and rapid-expansion effects at its inlet and exit interfaces are examined. After the steady state condition is achieved, local pressures and temperatures are measured and recorded. 92 age

ressure p (Ma-abs) 0ºC d d / 2 Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion.. 10.0 9.0 8.0 7.0 6.0 5.0 10ºC 5ºC 15ºC 25ºC 20ºC 30ºC 4.0 x =0 Quality 0.1 0.2 0.3 Specific enthalpy h (kj/kg) Figure 3 A part of the R744 Mollier chart for the experimental conditions III. Experimental Results and Discussion 3.1 heoretical estimation of pressure drop in the expansion valve Before the experiment, the pressure drop caused by the proposed expansion valve is theoretically estimated. he details of the estimation are shown in reference 7. he configuration of the valve is simulated by fundamental elements, as shown in Fig. 4. he specifications of the elements are shown in able 1. Especially, the processing accuracy of the groove is introduced in the estimation, because the groove has a very fine structure. he pressure drops caused by the elements that make up the valve are estimated individually, and the overall pressure drop is estimated. he theoretically obtained overall pressure drop and experimental results are shown in Fig. 5. It is difficult to estimate the local quality inside a valve by experiment. he principal pressure drop was caused by the V-shaped groove and its entrance and exit interface [7]. herefore the quality at the exit of the V-shaped groove and after there are assumed to be x = 0, 0.1 and 0.2 in the simulation. x = 0 means that the refrigerant did not start to boil after it passed the valve. hese results are shown in Fig. 5(a) - (c), respectively. he gradient of the theoretically estimated pressure drop becomes more gentle as the quality increases, because the density of the refrigerant becomes smaller even though the flow velocity increases. he pressure drop rises quickly and sharply as the groove width grows narrower. his is especially typical for the case of d d = 0.30 mm. d 0 Cylinder p 1 p 2 p 3 p d p 4 p 5 p 6 p 7 p 8 p 9 p 10 l 7 l 5 l d l 2 l 9 d 2 d 7 d 9 d d d 5 in hole Decompression domain (V-shaped groove) Diffuser Flow path to container cavity Container cavity Orifice Low-pressure tube d d d 11 (a) Flow model of refrigerant (b) Cross section of V-shaped groove Figure 4 Flow model for pulse driven-type electromagnetic control expansion valve able 1 Specification of the valve for theoretical estimation Index Elements Hydraulic diameter d (mm) Length l (mm) 0 Cylinder 3.0 1 Rapid-contraction 2 in hole 0.6 0.88 93 age

ressure drop p (Ma) ressure drop p (Ma) ressure drop p (Ma) Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion.. 3 Rapid-contraction d Decompression domain (d d) 0.3-0.45 3.8 x 2 4 Rapid-expansion 5 Flow path to container cavity 1.1 2.8 x 2 6 Rapid-contraction 7 Container cavity 1.85 4.1 x 2 8 Rapid-contraction 9 Orifice 0.6 4.0 10 Rapid-expansion 11 Low pressure tube 2.76 rocessing accuracy of V-shaped groove 0. 01 mm for d d 3.2 Experimental results of pressure drop he experimental conditions are shown in able 2. he width of the V-shaped groove varied from 0.30 mm to 0.45 mm every 0.05 mm steps. hese conditions are chosen corresponding to the theoretical conditions of each other. he experimental results are shown in Fig. 5, too. he experimentally obtained quality at the exit of the valve, estimated using a Mollier chart, was not distinguished in the figure. During the experiment, the qualities of the refrigerant at the exit of the valve were 0<x<0.2. he pressure drops obtained by the experiment were lower than those of the theoretical results except d d = 0.45 mm. However, the tendency of both results was the same. he pressure drop required is around 5 Ma or less. he theoretically estimated pressure drops for narrower grooves are quite different from the experimental value, especially for d d = 0.30 mm. he gradient of the results obtained by d d = 0.30 mm is very sensitive against the mass flow rate. It means that it is difficult to control the pressure drop carefully. On the other hand, it is insufficient to raise the pressure drop by using d d = 0.40 mm and 0.45 mm. d d = 0.35 mm may be suitable for the control of the pressure drop. he pressure drop can be reduced by opening the V-shaped groove by the pulse driven electromagnetic control valve. he pressure drop can be controlled by an electromagnetic control valve for the designed range. As a result, it was shown that the pulse driven-type electromagnetic control expansion valve proposed in this paper can be applied to control the pressure drop in a way suitable for fulfilling cooling demand. 10 10 8 8 6 6 4 4 2 2 0 0.0 2.0 4.0 6.0 8.0. Mass flow rate m (g/s) 0 0.0 2.0 4.0 6.0 8.0. Mass flow rate m (g/s) (a) x = 0 (b) x = 0.1 10 8 6 4 2 0 0.0 2.0 4.0 6.0 8.0. Mass flow rate m (g/s) in (ºC) out (ºC) 15 5 Estimation 23 13 Experiment d d (mm) 0.30 0.35 0.40 0.45 0.30 0.35 0.40 0.45 0.30 0.35 0.40 0.45 d d +, d d - (c) x = 0.2 Figure 5 Experimentally obtained pressure drop and theoretical estimation 94 age

Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion.. able 2 Experimental conditions for refrigerating cycle and V-shaped groove Refrigerant R744 (CO 2) Inlet pressure: p 0 6-9 Ma Inlet temperature: in 15, 23 ºC Outlet pressure: p 11 4-6 Ma Mass flow rate: m 2.0-7.0 (g/s) V-shaped groove width and length: d d, l 0.3-0.45 mm, 0.05 mm steps, 3.8 mm x 2 in hole diameter and length 0.6 mm, 0.88 mm Orifice diameter and length 0.6 mm, 4.0 mm IV. Conclusions he application of a new pulse driven-type electromagnetic control expansion valve for the R744 cycle is proposed, and the characteristics of the valve are experimentally examined in this paper. he experimental results were compared with the theoretically estimated results. he influence of the machining tolerance on the pressure drop is also estimated. he experimental results show lower values compared to theoretical results. articularly, the difference between them becomes greater when the groove width is narrower, because the flow pattern is very complicated when it becomes a two-phase fluid flow and passes through a narrow duct. However, both results show similar tendencies of about the same order against the mass flow rate, even though it becomes a very complicated fluid flow. hen the validity of this estimation is verified by the experiment. he pressure drop can be controlled by an electromagnetic control valve. As a result, it was shown that the pulse driven-type electromagnetic control expansion valve proposed in this paper can control the pressure drop in a way suitable for fulfilling cooling demand. V. Nomenclature d: Hydraulic diameter of duct [m] h: Specific enthalpy [J/kg] l: Length [m] m : Mass flow rate [kg/s] p: ressure [a] : emperature [ºC] x: Quality [-] Subscripts 0-11: index of position d: V-shaped groove References [1] G. W. Swift, hermoacoustic engines, Journal of the Acoustical Society of America, 84(4), 1988, 1145-1180. [2] Y. Kitaide, N. Maruyama, Y. Iwasaki, M. Saito, K. akiguchi, S. Ishida,. suchiya, Y. Yamagami and M. Hirota, Characteristics of hermoacoustic Sound Generator and Its Application to Refrigerator, roc. of 11 th International Energy Conversion Engineering Conference 2013, aper No. AIAA 2013-3811, 2013, 1-11. [3] N. Maruyama, Y. Iwasaki, M. Saito, Y. Kitaide, M. Hirota, K. akiguchi, S. Ishida,. suchya and Y. Yamagami, rincipal characteristics of thermoacoustic refrigerator, roc. of he Fifth International Conference on Science, echnology and Innovation for Sustainable Well-Being, aper No. MME20, 2013, CD-ROM, 1-6. [4] N. Maruyama, Y. Iwasaki, M. Saito, Y. Kitaide, K. akiguchi, S. Ishida, Y. Yamagami,. suchiya and M. Hirota, rincipal Characteristics of hermoacoustic Sound Generator and Refrigerator s Application, roc. of International Conference & Utility Exhibition on Green Energy for Sustainable Development, aper No. S01-7, CD-ROM, 2014, 1-7. [5] N. Maruyama, Y. Iwasaki, M. Saito, Y. Kitaide, K. akiguchi, S. Ishida,. suchya and M. Hirota, Characteristics of a Loop-type hermoacoustic Refrigerator with a Sound Generator, roc. of 12 th International Energy Conversion Engineering Conference 2014, aper No. AIAA 2014-3560, 2014, 1-8. [6] C. Baek, J. Heo, J. Jung, H. Cho and Y. Kim, Optimal control of the gas-cooler pressure of a CO 2 heat pump using EEV opening and outdoor fan speed in the cooling mode, International Journal of Refrigeration, 36(4), 2013, 1276-1284. [7] Y. Kitaide, N. Maruyama, M. Hirota, Y. Onishi and. suchiya, Development and Evaluation of ulse Driven-type Electromagnetic Control Expansion Valve applied to Small Scale Refrigerant Cycle, (art I: heoretical estimation of pressure drop), IOSR Journal of Engineering, 11(5-III), 2014, in print. [8] A. S. amitran, K. I. Choi, J.. Oh and H. K. Oh, wo-phase pressure drop during CO 2 vaporization in horizontal smooth minichannels, International Journal of Refrigeration, 31(8), 2008, 1375-1383. [9] R. Revellin and J. R. home, Adiabatic two-phase frictional pressure drops in microchannels, Experimental hermal and Fluid Science, 31, 2007, 673-685. [10] J. ettersen, Flow vaporization of CO 2 in microchannel tubes, Experimental hermal and Fluid Science, 28(2-3), 2004, 111-121. [11] Cavallini Alberto, Del Col Davide and Rossetto Luisa, Heat transfer and pressure drop of natural refrigerants in minichannels, International Journal of Refrigeration, 36(2), 2013, 287-300. [12] M. Ducoulombier, S. Colasson, J. Bonjour and. Haberschill, Carbon dioxide flow boiling in a single microchannel - art I: ressure drops, Experimental hermal and Fluid Science, 35(4), 2011, 581-596. 95 age

Development and Evaluation of a ulse Driven-type Electromagnetic Control Expansion.. [13]. N. ran, M. C. Chyu, M. W. Wambsganss and D. M. France, wo-phase pressure drop of refrigerants during flow boiling in small channels: an experimental investigation and correlation development, International Journal of Multiphase Flow, 26(11), 2000, 1739-1754. [14] J.. Liu, Y. M. Niu, J.. Chen, Z. J. Chen and X. Feng, Experimentation and correlation of R744 two-phase flow through short tubes, Experimental hermal and Fluid Science, 28(6), 2004, 565-573. [15] W. Li, Simplified modeling analysis of mass flow characteristics in electronic expansion valve, Applied hermal Engineering, 53(1), 2013, 8-12. [16] L. Chen, J. Liu, J. Chen and Z. Chen, A new model of mass flow characteristics in electronic expansion valves considering metastability, International Journal of hermal Science, 48(6), 2009, 1235-1242. 96 age