Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B

Similar documents
Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

diaphragm In-line service One pilot valve sub-assembly provides for any outlet set pressure, that is, 80 to 225 psi (5,5 to 15,5 bar)

The TYCO Model PRV-1 Pressure. Reducing Valves described herein must be installed and maintained in compliance with this document and with the

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Technical Data. UL Listing is based on the following criteria:

OBSOLETE. Wet pipe low flow manifold system

TECHNICAL DATA Q= C. Table 1 - Specifications

Services Department for information concerning the use of the ACC-1 for use with dry pipe valves other than the Model DPV-1.

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. Page 1 of 12

Model DPV-1 Dry Pipe Valve External Resetting. General Description. Technical Data. Page 1 of 20 AUGUST 2018 TFP1020. Worldwide Contacts

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Worldwide Contacts. General Description

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Worldwide Contacts. End Connection

HORIZONTAL BLADDER TANK

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Wet pipe low flow foam/water system

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Horizontal Bladder Tanks

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Electric Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

VERTICAL BLADDER TANK

TECHNICAL DATA CAUTION

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Dry Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Model MTB-ASME Horizontal Bladder Tanks

Vertical Bladder Tanks

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA OBSOLETE

Speed control assembly model A-1

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Pressure Independent Control Series

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

TECHNICAL DATA CAUTION

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA OBSOLETE

FloWash. Industrial Filter Cart

Bermad Pressure Reducing. Model: 42T

AIR FOAM CHAMBER DATA SHEET

TECHNICAL DATA. Trimpac 256a. October 31, 2013

a pilot sprinkler were to be closed after its initial operation, for example a remote manual control station).

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

AWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

FOAM TANK (1/2) DATA SHEET

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Air Eliminators and Combination Air Eliminators Strainers

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

SCA Series Inverted Bucket Steam Traps

WHEATLEY Series 500 Swing Check Valve

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Anti-flood device Model B-1

BS Series Basket Strainer

Irrigation System Winterization and Pressurization Procedures

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Electric Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

V43 Pressure Actuated Water Regulating Valve

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

TECHNICAL DATA. Q = C v P S

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Vertical and Horizontal Bladder Tanks

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Foam Chamber Model-FC

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA ACCELERATOR MODEL E-1

TECHNICAL DATA. Dry 132a. October 1, 2008

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

TITAN FLOW CONTROL, INC.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

TECHNICAL DATA. than the water inlet pressure to the concentrate

Bermad Model:

TECHNICAL DATA OBSOLETE

ELKHART BRASS MANUFACTURING COMPANY

Transcription:

Worldwide ontacts www.tyco-fire.com Model Pipe Line Strainer General Description The welded steel body Model Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connections to automatic sprinkler, water spray deluge, foam-water deluge, or standpipe fire protection systems. They are used where it is necessary to protect spray nozzles, sprinklers, or other type discharge outlets from obstruction by debris that may be in the water supply. Model Pipe Line Strainers feature: ompact, lightweight, welded hot dipped galvanized assembly Flanged inlet, outlet, and flushing connections orrosion resistant stainless steel screen High pressure rating Low pressure loss Wide range of inlet and outlet sizes Single and double outlet models The Model Pipe Line Strainer is a re designation for the Gem Model. NOTIE The Model Pipe Line Strainers de scribed herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NTIONL FIRE PROTETION SSOITION (NFP), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. ontact the installing contractor or product manufac turer with any questions. IMPORTNT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Technical Data pprovals UL and -UL Listed FM pproved Maximum Working Pressure 250 psi (7,2 bar) Finish Galvanized Friction Loss Refer to Graphs and Physical haracteristics ody....steel Inlet onnection...................... Steel End onnection...................... Steel asket ssembly............. Stainless Steel Gaskets............. Fiberglass and ramid with Nitrile inder asket Screen Perforations 1/ inch (3,2 mm) diameter holes spaced so as to provide 40 percent open area. Design riteria The Strainer is to be positioned horizontally as shown in Figures 1 or 2, and typically the outlet(s) are pointed vertically up as shown. The Strainer may be rotated axially to have the outlet(s) pointed from vertically to horizontally as viewed from the flushing connection end of the Strainer. In this case, the over ssembly with the flushing connection must be realigned, as applicable, to have the flushing connection at the lowest elevation of the asket ssembly so as to permit complete flushing of the asket ssembly. pipe saddle support sized to fit the Strainer ody (Dimension P, Figure 1 or 2) must be located beneath the center of each outlet. If the Strainer is rotated such that the outlet(s) are not pointed vertically up, additional provisions must be made for separate support of the outlet piping. The Strainer must be located where there is adequate clearance for complete removal of the asket ssembly to facilitate cleaning of the asket ssembly. In planning the installation, consideration must be given to disposal of flushing water since large quantities may be required to ensure thorough cleaning of the asket ssembly. Typically, the flushing connection is fitted with an appropriately sized, normally closed, flushing connection valve and hose connection. Installation The Model Pipe Line Strainer is shipped as an assembly. Inlet, outlet, and flushing connections are to be made in accordance with accepted piping practices. Provisions for the pipe saddle, basket removal clearances, and strainer flushing must be made in accordance with the requirements given in the Design riteria Section. Page 1 of 6 UGUST 201 TFP1644

Page 2 of 6 6 x 6 (150 x 150) Flange onnection Sizes 1 Inlet 6 (150) Outlet 6 (150) Flushing 2-1/2 (65) Dimensions D E F G 7 (177,) 1-1/16 (27,0) 52-1/2 (1333,5) 39-1/2 (1003,3) x (200 x 200) 4 (100) -1/4 (209,6) 1-1/4 (31,) 69-1/2 (1765,3) 54-3/4 (1390,7) 1. Refer to Table for Inlet, Outlet and Flushing flange connection specifications Dimensions ody 2 NPS olt Size Inch K L M N P R Weight lb (kg) 6 x 6 (150 x 150) 25-3/4 (654,1) 44-7/ (1139,) 50 (1270,0) 13-1/2 (342,9) 3/4 x 3-1/2 260 (11) x (200 x 200) 32-1/4 (19,2) 60 (1524,0) 65 (1651,0) 16 (406,4) 10 (250) 7/ x 3-1/2 500 (227) 2. Standard wall steel pipe per STM 53; size pipe saddle required for support of Strainer F K G UTILITY 1/2 NPT OUTLET FULL FE GSKET OVER D N E INLET P (TPERED SREEN) SUPPORT QTY. 3 L ORIENTING PIN R OLT FLUSHING M MINIMUM FOR REMOVL FIGURE 1 SINGLE OUTLET MODEL PIPE LINE STRINERS ND DIMENSIONS

Page 3 of 6 x 6 x 6 (200 x 150 x 150) Flange onnection Sizes 1 Inlet Outlet 6 (150) Flushing 4 (100) Dimensions D E F G H 9-1/2 (241,3) 2 (50,) 73-1/4 (160,6) 54-3/4 (1390,7) 1-1/2 (469,9) 10 x x (250 x 200 x 200) 10 (250) 4 (100) 11 (279,4) 3 (76,2) 4 (2133,6) 64-1/2 (163,3) 19-1/2 (495,3) 1. Refer to Table for Inlet, Outlet and Flushing flange connection specifications Dimensions ody 2 NPS J K L M N P R olt Size Inch Weight lb (kg) x 6 x 6 (200 x 150 x 150) 36-1/4 (920,) 36-5/ (930,3) 59-1/4 (1505,0) 64 (1625,6) 16 (406,4) 10 (250) 7/ x 3-1/2 510 (231) 10 x x (250 x 200 x 200) 45 (1143,0) 42 (1066,) 70 (177,0) 75 (1905,0) 19 (42,6) 12 (300) 7/ x 3-1/2 55 (3) 2. Standard wall steel pipe per STM 53; size pipe saddle required for support of Strainer F H K G J UTILITY 1/2 NPT OUTLET QTY. 2 FULL FE GSKET QTY. 2 OVER D E N INLET P (STRIGHT SREEN) SUPPORT QTY. 3 L ORIENTING PIN R OLT FLUSHING M MINIMUM FOR REMOVL FIGURE 2 DOULE OUTLET MODEL PIPE LINE STRINERS ND DIMENSIONS

Page 4 of 6 NOMINL PRESSURE DROP IN POUNDS PER SQURE INH (PSI) 10.0.0 6.0 5.0 4.0 3.0 2.0 1.0 0. FLOW RTE IN LITERS PER MINUTE (LPM) (1 GPM = 3,75 LPM) 3000 4000 6000 10000 20000 6"x6" "x" 0,60 0,50 0,40 0,30 0,20 0,10 0,0 0,06 0,05 0.6 0,04 0.5 600 1000 2000 4000 6000 FLOW RTE IN GLLONS PER MINUTE (GPM) GRPH SINGLE OUTLET MODEL PIPE LINE STRINERS NOMINL PRESSURE LOSS VS. FLOW FULL FE GSKET ORIENTING PIN HOLE FIGURE 3 MODEL PIPE LINE STRINERS ORIENTTION NOMINL PRESSURE DROP IN R (1 PSI = 0,0695 R) END RING OVER FLUSHING (a) 100% flow through either outlet (no flow through other outlet) (b) Outlet #1 with 50% flow through each outlet (c) Outlet #2 with 50% flow through each outlet NOMINL PRESSURE DROP IN POUNDS PER SQURE INH (PSI) NOMINL PRESSURE DROP IN POUNDS PER SQURE INH (PSI) 10.0.0 6.0 5.0 4.0 3.0 2.0.0 6.0 5.0 4.0 3.0 2.0 1.0 0. (a) INLET (a) (b) (b) OUTLET #1 FLOW RTE IN LITERS PER MINUTE (LPM) (1 GPM = 3,75 LPM) 3000 4000 6000 10000 20000 0,0 1.0 0. 0,06 0,05 0.6 0,04 0.5 600 1000 2000 4000 6000 FLOW RTE IN GLLONS PER MINUTE (GPM) "x6"x6" STRINER 0.6 0,04 0.5 1000 2000 4000 6000 10000 FLOW RTE IN GLLONS PER MINUTE (GPM) 10"x"x" STRINER (c) FLOW RTE IN LITERS PER MINUTE (LPM) (1 GPM = 3,75 LPM) 4000 6000 10000 20000 30000 10.0 (c) OUTLET #2 GRPH DOULE OUTLET MODEL PIPE LINE STRINERS NOMINL PRESSURE LOSS VS. FLOW 0,60 0,50 0,40 0,30 0,20 0,10 0,60 0,50 0,40 0,30 0,20 0,10 0,0 0,06 0,05 NOMINL PRESSURE DROP IN R (1 PSI = 0,0695 R) NOMINL PRESSURE DROP IN R (1 PSI = 0,0695 R)

Page 5 of 6 Dim. 2-1/2 Inch (DN65) 5.50 (139,7) 0.75 (19,0) are and Maintenance The following inspection procedure must be performed as indicated, in addition to any specific requirements of the NFP. ny impairment must be immediately corrected. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NTIONL FIRE PROTETION SSOITION (e.g., NFP 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTE: efore closing a fire protection system control valve for inspection or maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. fter placing a fire protection system in service, notify the proper authorities and advise those responsible for monitoring proprietary and/or central station alarms. Maintenance Procedure It is recommended that the Strainers be flushed at least annually. More frequent flushing may be necessary where water supplies are non portable and/or contain debris which could clog 1/3 or more of the basket open area. NOTE: Never disassemble or remove any strainer component without verifying that the system is depressurized and drained. Flange onnection Size Dimensions*, 4 Inch (DN100) 7.50 (190,5) 0.75 (19,0) 6 Inch (DN150) 9.50 (241,3) 0. (22,2) Inch (DN200) 11.75 (29,5) 0. (22,2) 10 Inch (DN250) 14.25 (362,0) 1.00 (25,4) Qty. N 4 12 * Flange drilling per NSI 16.5 (lass 150) TLE MODEL PIPE LINE STRINERS OUTLET FLNGE DRILLING DIMENSIONS Strainers should be thoroughly flushed clean after each system operation or flow test and during routine inspections, as follows: Step 1. Open the flushing connection valve and continue flow until the water runs clear. Step 2. If heavy sediment in the water persists, or there are indications that all debris such as large stones may not have been removed, the system must be shut down, the Strainer drained, and the asket ssembly removed for cleaning. Step 3. Remove the over ssembly and the asket ssembly. When removing the asket ssembly, with draw it slowly to minimize the possibility of debris falling out the back. Step 4. lean out the asket ssembly, as well as the inside of the Strainer ody. Step 5. When reinstalling the asket ssembly, make certain that the asket ssembly End Ring with the basket orienting pin hole is at the over ssembly end of the Strainer, and that the basket orienting pinhole is at the top as shown in Figure 3. Step 6. When reinstalling the over ssembly, make certain that the asket ssembly is fully inserted into the Strainer ody, and that the asket Orienting Pin will engage with the asket ssembly End Ring (Ref. Figure 3). Gradually cross tighten all bolts so that a uniform load is applied around the periphery of the over ssembly. Limited Warranty Dim. olt ircle Diameter Dim. olt Hole Diameter Qty. N Number of olt Holes For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Orders must include the description and Part Number (P/N). ontact your local distributor for availability. Strainers Specify: (Specify size) Model Pipe Line Strainer, P/N (specify): 6 in. x 6 in....52-390-1-013 in. x in....52-390-1-016 in. x 6 in. x 6 in............... 52-390-1-017 10 in. x in. x in.............. 52-390-1-019 Replacement Parts Specify: (Specify description) for (specify size) Model Pipe Line Strainer, P/N (specify): Stainless Steel asket ssembly 6 in. x 6 in....92-390-1-113 in. x in....92-390-1-116 in. x 6 in. x 6 in............... 92-390-1-117 10 in. x in. x in.............. 92-390-1-019 Full Face Gasket 6 in. x 6 in....92-390-1-313 in. x in....92-390-1-316 in. x 6 in. x 6 in............... 92-390-1-316 10 in. x in. x in.............. 92-390-1-319

Page 6 of 6 1400 Pennbrook Parkway, Lansdale, P 19446 Telephone +1-215-362-0700 201 Johnson ontrols. ll rights reserved. ll specifications and other information shown were current as of document revision date and are subject to change without notice. NTIONL FIRE PROTETION SSOITION and NFP are registered trademarks of National Fire Protection ssociation