Spray drift of drift reducing nozzle types spraying a bare soil surface with a boom sprayer

Similar documents
Determination of Contribution to Off-field Deposition from Multiple Swaths

An Attempt to Relate Drop Size to Drift Risk

Best Practices to manage spray drift issues (How to reduce emissions from spray drift)

Modelling spray drift from boom sprayers

INFLUENCE OF BOOM HEIGHT AND WORKING PRESSURE ON DISTRIBUTION UNIFORMITY ON THE WIDTH OF SPRAYING MACHINES

Phantom Air Blast Sprayer Conversion to Spinning Disk

Techniques for measuring Spray drift

Measurement & Analytics Wet gas monitoring

Capacity of transport infrastructure networks

Distribution of fishing intensity of pulseand beam trawling in the North Sea. Marcel Machiels. IMARES rapport C146A/15

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Measuring Surface Wind Velocity Changes

BICYCLE RESEARCH REPORT NO. 89

Parallel Particle Impactors New Personal Samplers for Accurate Assessment of Worker Exposure to Respirable or Thoracic Dust

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Pesticide Applicator Safety for Structural Applicators Calculations

Influence of wind direction on noise emission and propagation from wind turbines

Abstract. 1 Introduction

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

BOOMLESS NOZZLES WIDE ANGLE FULL CONE SPRAY TIPS

Evaluation of Plant Growth Regulators and Fertilizer to Fairway Height Creeping Bentgrass J.A. Borger and M.B. Naedel 1

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

STATIONARY SPRINKLER IRRIGATION SYSTEM

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

(segmental) Instruction manual

IK 12 VC: 7,5 ltr. Tank explanation

Charles T. Golob, William J. Johnston, and Karine Paré Dept. Crop and Soil Sciences Washington State University Jan. 3, 2008

Siting classification for Surface. Michel Leroy, Météo-France

Viscosity Agents vs. Invert Emulsions for Glyphosate Efficacy.

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

Analyzing a Malfunctioning Clarifier with COMSOL s Mixture Model

FOR WASTEWATER APPLICATIONS

IR-4 FIELD DATA BOOK

Oxygen mass transfer in a bubble column with non-newtonian fluids

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Lab 1. Adiabatic and reversible compression of a gas

Smoke and heat Ventilator Testing

Earmuff Comfort Evaluation

BS EN 14605: 2005 Type 3 or 4 Protective Clothing

IMPACT OF DOCKING METHOD ON LOADS IN ELEMENTS FLOATING DOCK VESSEL UNIT

Statistical Analysis of PGA Tour Skill Rankings USGA Research and Test Center June 1, 2007

IR-4 FIELD DATA BOOK

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

Final Report. Herbicide screening trial. Les Mitchell Eurofins Agrisearch. Project Number: TU13032

IMARES Wageningen UR. North Sea mackerel egg survey C.J.G. van Damme & C. Bakker. Report number C106/14

Dollarspot continues to be a

TRAINING ON ANTAM STANDARD CODE For TESTING OF KNAPSACK MISTERS CUM DUSTERS

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

KWA. Evaluation of the MassTech 001 Tank Integrity Test System. EPA Forms Obtained From

Objective: Experimental Procedures:

TECHNICAL ACCESSORIES

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Evaluation of n-situ easurement ethods for ir ermeability of indows

The effect of close proximity, low height barriers on railway noise

EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

New Zealand Piped Irrigation System Performance Assessment Code of Practice

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Civitas + Harmonizer with or without Low Rates of Fungicides to Control Snow Mold on Putting Greens in Washington

Modeling Approaches to Increase the Efficiency of Clear-Point- Based Solubility Characterization

FEATURES Precision Turfgrass Management

Dropp UltraMAX CONTENTS

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS

Transferpette. Lightweight precise rugged reliable!

Guidance on room integrity testing and its interpretation

Validation of SEC/GPC Software

AMENDMENTS TO THE IMSBC CODE AND SUPPLEMENTS

3D Turbulence at the Offshore Wind Farm Egmond aan Zee J.W. Wagenaar P.J. Eecen

COURSE OUTLINE. Page : 1 of 5

THE EFFECT OF VARIOUS DIKE REINFORCEMENT ALTERNATIVES ON THE FLOOD SAFETY ASPECTS OF THE DELTADIKE CONCEPT

Manual for continuous distillation

The Daily Record. 42 The National Strategies Secondary Mathematics exemplification: Y7 NUMBER. Place value, ordering and rounding

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

ENTAM - TEST REPORT. Trailed Field Crop Sprayer HARDI CM plus TWIN FORCE. Design 66

Variation of Nordic Classic Ski Characteristics from Norwegian national team athletes

Exposure estimations before and after the new EFSA-Guidance ECPA s perspective based on examples

Hygea Ultrasonic Validation Kit

LABORATORY EXPERIMENTS FOR WAVE RUN-UP ON THE TETRAPOD ARMOURED RUBBLE MOUND STRUCTURE WITH A STEEP FRONT SLOPE

01 18/11/2013 correction of the reference of the product 1 4 5

Procedia Engineering Procedia Engineering 2 (2010)

ACCESSORIES CATALOGUE. Guarany offers a complete line of accessories to optimize many spraying applications, assuring the best cost-benefit.

CRYSTALLIZATION FOULING IN PACKED COLUMNS

NZQA registered unit standard version 3 Page 1 of 7. Demonstrate knowledge of bitumen gangbar sprayers and operations

CeCeCe TM OTHER. Active ingredient: chlormequat chloride g /

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152

The OWEZ Meteorological Mast

Pedestrian Speed-Flow Relationship for. Developing Countries. Central Business District Areas in

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

This document is a preview generated by EVS

Relative Dosimetry. Photons

Reducing Pesticide Drift by Considering Propeller Rotation Effects From Aerial Application Near Buffer Zones

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

FlexAct BT (Bag Tester) Validation November, 2015

EN ISO/IEC Technical Requirements

Modelling of Extreme Waves Related to Stability Research

Transcription:

Aspects of Applied Biology 122, 2014 International Advances in Pesticide Application Spray drift of drift reducing nozzle types spraying a bare soil surface with a boom sprayer By J C VAN DE ZANDE, J M G P MICHIELSEN, H STALLINGA and P VAN VELDE Wageningen UR - Plant Research International (WUR-PRI), P.O. Box 616, 6700 AP Wageningen, The Netherlands Corresponding Author Email: jan.vandezande@wur.nl Summary In the Netherlands spray drift reduction measures are obligatory when spraying alongside waterways. Drift Reducing Technology (DRT) is certified through standardised spray drift measurements in the field and by means of the classification of drift reducing nozzle types in the laboratory. Approved DRT and classified nozzles in the drift reduction classes 50%, 75%, 90% and 95% are officially published on a website. Since the introduction of the nozzle classification system in 1999, little measurements have been done with higher levels of drift reducing nozzles, and not at all with the recently developed nozzle types. Moreover the initial spray drift measurements in the field to calibrate the spray drift model IDEFICS were performed spraying a potato crop. Therefore a series of measurements was set up to validate the outcome of the spray drift model with field results of some old and new nozzle types spraying a bare soil surface with a boom sprayer. Results are presented for spray drift deposition next to the sprayed swath on bare soil surface and for airborne spray drift measured at 5 m and 10 m distance from the last nozzle up to 6 m height. A comparison is made with the outcome of the classification of the different nozzle types based on spray drift model calculations and the field measurements on bare soil surface. A comparison is also made with the results from the same nozzle types running over a standard drift test bench (ISO22369-3) which were measured under similar conditions in the field. Key words: Spray drift, Drift Reducing Technology, airborne drift, drift reduction, nozzle classification Introduction In the Netherlands spray drift reduction measures are obligatory when spraying alongside waterways. Drift Reducing Technology (DRT) is certified through standardised spray drift measurements in the field (ISO22866; CIW, 2003) and by means of the classification of drift reducing nozzle types (VW & LNV, 2001; Porskamp et al., 1999). Approved DRT and classified nozzles in the drift reduction classes 50%, 75%, 90% and 95% are published on the website (TCT, 2013). Nozzle classification in drift reduction classes is done based on spray drift calculations using the IDEFICS model (Holterman et al., 1997) under standard field conditions and drop size and drop speed measurements in the laboratory of the specific nozzle. Since the introduction of the classification system in 1999 little measurements have been done with higher levels of drift reducing nozzles, and not at all with the recently developed nozzle types. Moreover the initial spray drift measurements in the field to calibrate the model were only performed spraying a potato crop (Zande et al., 245

2000). Therefore a series of measurements was setup to validate the outcome of the model with field results of some old and new nozzle types spraying a bare soil surface with a boom sprayer. Results are presented for spray drift deposition next to the sprayed swath on bare soil surface and for airborne spray drift measured at 5 m and 10 m distance from the last nozzle up to 6 m height. A comparison is made with the outcome of the classification of the different nozzle types based on model calculations) and the field measurements on bare soil surface to show the similarity (or difference). A comparison is also made with the results from the same nozzle types running over a standard drift test bench (ISO22369-3; Balsari et al., 2007) which were measured under similar conditions in the field. Materials and Methods In November 2012 field measurements of spray drift were done to quantify the effect of different drift reducing nozzle types. Measurements were performed spraying a bare soil surface using a 27 m working width John Deere 840i sprayer (Fig. 1). Boom height during measurements was 50 cm above soil surface, nozzle spacing was 50 cm, sprayer speed was 6 km h -1 and spray pressure was for some nozzles 3 bar and some 1 bar. Nozzles were selected from earlier measurement (Zande et al., 2000, 2012) and from the low drift nozzle list (TCT, 2013) from the classes 75%, 90% and 95% drift reduction. As reference nozzle a Teejet XR11004 nozzle was used sprayed at 3 bar spray pressure. The nozzle types selected were: TeeJet DG11004 pre-orifice flat fan nozzle (50% drift reducing, 3 bar), Agrotop XLTD11004 venturi flat fan nozzle (90% drift reducing, 3 bar), Lechler IDN12003 venturi flat fan nozzle (75% drift reducing, 3 bar), TeeJet AIXR11004 venturi flat fan nozzle (90% drift reducing, 1 bar) and Agrotop Airmix 11004 venturi flat fan nozzle (95% drift reducing, 1 bar). Wind direction during the measurements was ±30 o cross to the driving direction of the sprayer. Spray drift measurements were done following ISO22866. Collectors (Technofil TF-290; 0.10 m 0.50 m) were placed on soil surface at 0.5 m till 6 m distance from the last nozzle and at 10 m, 15 m, 20 m and 25 m (Technofil TF-290; 0.10 m 1.0 m). At 5 m and 10 m distance from the last nozzle airborne spray drift was measured up till 6 m height using at every metre, ball shaped collectors (Siebauer Abtrifftkollektoren). Spray liquid was tap water with a fluorescent tracer added (Brilliant Sulfo Flavine, BSF, 3 g L -1 ) and an additive to mimic agrochemical tank mix (Agral Gold, 0.0075%). Fig. 1. Field measurement of spray drift spraying a bare soil surface. At the end of the sprayed track a test bench was setup to measure the Drift Potential Value (Fig. 2). Driving direction over the test bench was into the wind direction. The test bench was positioned in the centre of half the boom width (left) parallel to the wind direction. The same nozzles as used in the field measurements of spray drift were used to quantify DPV on the test bench. Nozzles used in both experiments are specified in Table 1. Collectors used were filter 246

Fig. 2. Spray drift test bench measurement of Drift Potential Value. material (Technofil TF290), stuck to the positions on pvc plates with velcro tape, and measuring 0.50 0.10 m and 1.00 m 0.10 m for the field lay-out and of 0.25m 0.10 m for the test bench. Table 1. Used nozzles, applied spray volume (l/ha) and typical parameters to specify spray quality as measured with PDPA-system (from Zande et al., 2012) Nozzle type Manufacturer Spray pressure [bar] Nozzle Flow rate [L min -1 ] D 10 (µm) VMD (µm) D 90 (µm) V100 (% < 100 µm) Spray volume [L ha -1 ] XR 11004 TeeJet 3,0 1,61 140 274 434 3,41 330 DG 11004 TeeJet 3,0 1,64 168 322 507 1,90 335 XLTD 11004 Agrotop 3,0 1,67 251 485 794 0,47 340 IDN 12003 Lechler 3,0 1,20 296 573 913 0,24 245 AIXR 11004 TeeJet 1,0 0,92 348 646 967 0,13 190 Airmix 11005 Agrotop 1,0 1,16 332 648 982 0,17 240 After spraying the collectors were collected and stored for analysis in the laboratory. In the laboratory collectors were diluted with demineralised water (1000 ml for 1.0 m and 0.5 m collectors and 100ml for 0.25 m collectors). Weather conditions during the drift measurements were recorded. For the field measurements a weather pole was set up in between the two measuring places and a metpak ultrasonic weather station next to the test bench. Average wind speed during the measurements was 2.9 m s -1, temperature was 9 o C and wind direction was for the field measurements 20 o perpendicular to the driving direction. Number of repetitions was eight for the field measurements and three for the test bench. Results Spray drift field measurements Results for the spray drift field measurements is presented in Fig. 3 as spray drift deposition (% of sprayed volume) downwind of the sprayed swath (27 m wide). Spray drift deposition decreases with increasing distance from the sprayed swath. 247

Fig. 3. Average spray drift deposition (% of sprayed volume) downwind of a 27 m sprayed swath of bare soil surface using different nozzle types at a boom height of 50 cm above ground surface and a driving speed of 6 km h -1. The spray drift deposition is presented at evaluation zones of 2 3 m distance from the last nozzle, which is used in The Netherlands for drift reduction classification as in general that is the area where the surface water is with most arable crops. Following ISO22369-2 (2006) also spray drift deposition is presented for the evaluation zones 1 5 m, 5 10 m, and 10 15 m from the last nozzle to be able to make a better comparison with the results from the test bench and show how spray drift deposition and reduction changes with distance from the treated area (Table 2). Table 2. Average spray drift deposition (% of sprayed volume) at different evaluation zones from the last nozzle for different nozzle types downwind of a 27 m sprayed swath of bare soil surface sprayed at a boom height of 50 cm above ground surface and a driving speed of 6 km h -1 Evaluation zone [m from last nozzle] dop n ## 2 3 m 1 5 m 5 10 m 10 15 m XR 8 1.39 a 1.63 a 0.27 a 0.14 a DG 6 0.50 b 0.53 b 0.13 b 0.08 b XLTD 6 0.24 c 0.24 c 0.05 c 0.02 c,d IDN 7 0.13 c,d 0.14 c 0.04 c,d 0.04 c AIXR 8 0.05 e 0.07 d 0.03 d 0.02 d Airmix 8 0.05 e 0.06 d 0.02 e 0.02 d a) different letters mean significant differences at 95% confidence level. Spray drift reduction on the presented evaluation zones is calculated relative to the spray drift deposition of the reference XR11004 nozzle in Table 3. At the NL evaluation zone (2 3 m from last nozzle) the nozzles will be classified (ISO22369-1, 2006) in the classes 50% for the DG11004, 75% for the XLTD11004, 90% for the IDN12003 and 95% for the AIXR11004 and Airmix11005 both at 1 bar spray pressure. This ranking is similar for the 1 5 m evaluation zone but changes for the 5 10 m and 1 15 m zones 248

(DG in 50% class, XLTD, IDN and AIXR in 75% class and Airmix in 90% class) and to all classified as 75% for the 10 15 m zone except the DG11004 which is lower than 50% class. Table 3. Spray drift reduction (%) on different evaluation zones from the last nozzle for different nozzle types downwind of a 27 m sprayed swath of bare soil surface sprayed at a boom height of 50 cm above ground surface and a driving speed of 6 km h -1 Evaluation zone [m from last nozzle] dop n ## 2 3 m 1 5 m 5 10 m 10 15 m 1 15 m XR 8 0 0 0 0 0 DG 6 64% 68% 51% 43% 54% XLTD 6 83% 85% 83% 83% 83% IDN 7 90% 91% 86% 75% 84% AIXR 8 96% 95% 87% 85% 89% Airmix 8 97% 96% 93% 87% 92% Airborne spray drift Airborne spray drift was measured up to 6 m height at 5 m and 10 m distance downwind from the last nozzle (Fig. 4 and Table 4). Airborne spray drift reduced averaged over 6 m measuring height from the XR to the DG, XLTD, IDN, AIXR and Airmix nozzle type, both at 5 m and at 10 m distance from the last nozzle. Airborne spray drift is highest at 1 m height for the XR, DG and XLTD nozzle type and less clear for the other nozzle types. Airborne spray drift for the XR11004 nozzle (3 bar) is 1.51% at 1 m height and 0.61% over 6 m height at 5 m and reduced to 0.81% at 1 m height and 0.40% over 6 m height at 10 m distance. Airborne drift is lowest for the Airmix 11005 nozzle (1 bar) with highest values at 2 m height of 0.09% at 5 m distance and 0.03% at 10 m distance, and average over height values of 0.03% and 0.02% at respectively 5 m and 10 m from the last nozzle. Airborne drift reduction relative to the XR11004 was at 5 m distance 59% for the DG, 80% for the XLTD, 91% for the IDN, 94% for the AIXR and 95% for the Airmix nozzle types. Table 4. Airborne spray drift (average of 6 m height, % of sprayed volume) of different spray nozzles spraying a bare soil surface at 5 m and 10 m distance from the last nozzle and drift reduction relative to XR nozzle Nozzle Airborne drift 5 m Airborne drift 10 m Drift reduction 5 m Drift reduction 10 m XR 0.61 0.40 reference reference DG 0.25 0.18 59% 54% XLTD 0.12 0.08 80% 80% IDN 0.06 0.04 91% 90% AIXR 0.03 0.03 94% 93% Airmix 0.03 0.02 95% 96% Spray drift modelling (Zande et al., 2012) resulted in spray drift reduction values relative to thexr11004 nozzle of 51% for the DG, 88% for the XLTD, 94% for the IDN, 96% for the AIXR and 96% for the Airmix. Test bench Average results (three repetitions) of the spray deposition (% of sprayed volume) deposited on the test bench is presented in Fig. 5. 249

Fig. 4. Airborne spray drift (% of sprayed volume) up to 6 m height measured at 5 m (top) and 10 m (bottom) from the last nozzle for different nozzle types at 6 km h -1 forward speed spraying a bare soil surface. Total spray deposition on the test bench is calculated as Drift Potential Value. Rather large differences were found in the summed spray deposition and therefore DPV values between the repetitions. Coefficients of variation ranged from 5% to 75% for the different nozzle types. Differences between DPV values of the different nozzles are therefore not significant although DPV may decrease by more than half (Table 6). Reduction in DPV values compared to the XR11004 nozzle as reference is 49% for the DG nozzle type, 77% for the XLTD, 79% for the IDN, 91% for the AIXR and 93% for the Airmix nozzle type. At the 95% confidence level the DG is lower than the reference XR nozzle type, and the other nozzles are all lower than the DG nozzle but not different form each other. At the 90% confidence level the Airmix nozzle is different from the XLTD nozzle but not from the IDN and AIXR nozzle type. Clearly more repetitions are needed to make these differences statistically significant. 250

Fig. 5. Spray deposition (% of sprayed volume) for different nozzle types measured after passing of the sprayer on the test bench (three repetitions). Table 5. Average DPV values for the different nozzles and statistical differences at 95% level and 90% level Nozzle XR DG XLTD IDN AIXR Airmix Avg DPV 66% 34% 15% 14% 6% 4% %CV 32% 22% 16% 75% 5% 48% DPV reduction Reference 49% 77% 79% 91% 93% diff-95% a b c c c c diff-90% a b c c,d c,d d Discussion Depending on what zones are looked at in field measurements similar results are obtained for field measurements and the test bench. The ranking of the nozzles is for both test methodologies similar, depending on the evaluation zone. The absolute values do differ for some nozzle types. Spray drift reduction levels in the field were found up to more than 95% for the Airmix AM111005 (1 bar spray pressure). Modelling results coincide very well with the results of field measurements at 2 3 m and 1 5 m distance from the last nozzle. Also airborne spray drift reduction is similar to results for soil deposition at different distances. A drift reduction of 95% for airborne spray drift was found for the Airmix AM 11005 nozzle (1 bar). Ranking of the nozzles in drift reduction was similar for field measurements as soil deposition and airborne spray drift reduction as well as for the test bench method and the spray drift modelling. Not all methods resulted however in a classification of the nozzles in the same drift reduction class. Spray drift deposition on the test bench correlates very well with the spray quality parameters D10, D50(VMD), D90 and V100 the volume fraction smaller than 100 um (Fig. 6). The relation V100 and average spray deposition on the test bench is almost a 1:1 one for the different nozzle types. 251

Table 6. Comparison of spray drift reduction values of different nozzle types relative to XR11004 nozzle based on field measurements for evaluation zones 2 3 m, 1 5 m, 1 15 m, airborne drift at 5 m distance from the last nozzle and a drift test bench Nozzle Field 2 3 m Field 1 5 m Field 1 15 m Airborne drift reduction 5 m Test bench Drift modelling XR Reference Reference Reference Reference Reference Reference DG 64% 68% 54% 59% 49% 51% XLTD 83% 85% 83% 80% 77% 88% IDN 90% 91% 84% 91% 79% 94% AIXR 96% 95% 89% 94% 91% 96% Airmix 97% 96% 92% 95% 93% 96% Fig. 6. Relation between spray quality parameters D10, D50(VMD), D90 and V100 and average spray deposition on the test bench for the different nozzle types. Acknowledgements This project is sponsored by the Ministry of Economic Affairs (BO-12.03-019-013 Classification of Drift Reducing Technologies) of the Netherlands. References Balsari P, Marucco P, Tamagnone M. 2007. A test bench for the classification of boom sprayers according to drift risk. Crop Protection 26:1482 1489. CIW. 2003. Beoordelingsmethodiek emissiereducerende maatregelen Lozingenbesluit open teelt en veehouderij. Commissie Integraal Waterbeheer, Ministerie van Verkeer en Waterstaat, Werkgroep 4 Water en Milieu, Den Haag. 82 pp. 252

Holterman H J, van de Zande J C, Porskamp H A J, Huijsmans J F M. 1997. Modelling spray drift from boom sprayers. Computers and Electronics in Agriculture 19:1 22 ISO 22866. 2005. Equipment for crop protection Methods for the field measurement of spray drift. Geneva: International Standardisation Organisation. ISO 22369-1. 2006. Crop protection equipment - Drift classification of spraying equipment -- Part 1: Classes. Geneva: International Organization for Standardization. ISO 22369-2. 2010. Crop protection equipment - Drift classification of spraying equipment -- Part 2: Classification of field crop sprayers by field measurements. Geneva: International Organization for Standardization. ISO 22369-3. 2013. Crop protection equipment - Drift classification of spraying equipment -- Part 3: Potential spray drift measurement for field crop sprayers by the use of a test bench. Geneva: International Organization for Standardization (in preparation). Porskamp H A J, van de Zande J C, Holterman H J, Huijsmans. J F M. 1999. Opzet van een classificatiesysteem voor spuitdoppen op basis van driftgevoeligheid (Classification of spray nozzles based on driftability). IMAG-DLO Rapport 99-02. Wageningen: IMAG. 22 pp. VW & LNV. 2001. Regeling testmethoden driftarme doppen Lozingenbesluit open teelt en veehouderij. Staatscourant 1 maart 2001, nr. 43, p. 18. TCT. 2013. List with drift reducing technologies and nozzles. Website: www.helpdeskwater.nl Zande J C van de, Michielsen J M G P, Stallinga H, Jong A de. 2000. Ranking of low-drift nozzles and air assistance for spray drift. Paper 00-PM-066 presented at AgEng 2000, Warwick, UK. 9 pp. Zande J C van de, Groot T T, Holterman H J. 2012. Drift bij hoge rijsnelheid. Modelberekeningen naar effect van rijsnelheid, doptype, spuitboomhoogte en dopafstand op de spuitboom. Wageningen: Wageningen UR Plant Research International, Plant Research International Rapport 482. 253

254