Apparatus Operator Refresher Training Program

Similar documents
Apparatus Operator/Pumper

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Releasal Manual

Fire Apparatus Operator: Pumper

Driver Operator Pumps: Basic Pump Operations

Fire Apparatus Operator: Pumper

KILGORE FIRE DEPARTMENT

Chapter 14 Water Shuttle Operations

TurboDraft Fire Eductor

Des Plaines Fire Dept. Engineer Program

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

2017 Volunteer Week - Course Descriptions

San Ramon Valley Fire Protection District

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

Chapter 1 FF I Orientation and Fire Service History

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Essentials of Fire Fighting 6 th Edition Firefighter I

Cozumel Turbodraft. Operational Considerations

FIREGROUND HYDRAULICS

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

TurboDraft. Fire Eductor Operating Instructions.

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

Essentials of Fire Fighting

Northeastern Illinois Public Safety Training Academy. Course Syllabus 103

Varying pump capacity affects the required hoseline diameter

Florissant Valley Fire Protection District Monthly Training Schedule

Chapter Overview. NFPA Standards NFPA 1001 Standard. Fire Fighter I

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

FIRE FIGHTER II JPR: FFII-1A

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE I FIRE PROTECTION BUREAU. Assigned to: Name:

Volunteer Firefighter Applicant Information Package

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P

Galva Fire Department SOP

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

17 15 NOVA SCOTIA FIRE SERVICE TRAINING EXTERIOR LEVEL (PHASE 2)

Water Supply for Suburban and Rural Firefighting

APPARATUS DRIVER / OPERATOR PUMPER

NFPA Standard on. Training for Initial Emergency Scene Operations Edition

Fire Apparatus Operator: ARFF

Ocean County Fire Academy. Fall 2018 Course Listings

Wilton Fire Protection District. TRAINING DIVISION New apparatus

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

Fire Apparatus Operator (FAO)

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Idaho Fire Service Technology Fire Fighter II

TRAINING NEEDS ASSESSMENT DRILL

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

===============================================================

West Metro Fire Protection District

Bermad Pressure Reducing. Model: 42T

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

22. Specialty Valves.

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST

North Carolina Fire and Rescue Commission Live Fire Audit Form

Model 420-HY Pressure Regulating Hydrant Valve

Manhattan Fire Protection District

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

CLEARWATER FIRE AND RESCUE DEPARTMENT STANDARD OPERATING PROCEDURE APPROVED BY: EFFECTIVE DATE: 10/12/07 REVISION DATE:

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

FSRS Relative Point Value Guide

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE

Autumn 2018 Firefighter 1

Iowa s s Minimum Training Standard. How to Be Prepared?

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

State of Oregon Department of Public Safety Standards and Training. Driver Task Book. Task Book Assigned To:

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

South Carolina Fire Academy

Pump Stages. By Tom Murray

Head to Head Demo Comparison Sheet

Engine Compan. pany y Operations. Firefighting and Emergency Operations Volume I - General Firefighting Procedures Book 2 Issued November 2003

Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig Level of Instruction: In service personnel Time Required: 3 hours

GEORGIA FIREFIGHTER STANDARDS AND TRAINING FIREFIGHTER PERFORMANCE EVALUATION & INSTRUCTIONS SHEET

Colorado Division of Fire Prevention and Control Firefighter I JPR's (NFPA 1001, 2013 Edition)

Wayne County Community College District

DRIVER/OPERATOR - PUMPER NFPA 1002

Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream.

Model: 43T. Bermad Pressure Relief Valve

Student Workbook SW2. Fireground Support operations

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

Transcription:

Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1

Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct pressure using booster tank water to correct GPM s at correct discharge pressure without noticeable changes in pressure (+ / - 10psi) and change over to supplied water source (hydrant) without noticeable changes in pressure ( + / - 10psi) using relief valve and feathering of valves as indicated. Purpose: To gain experience in the techniques of gating and feathering of valves in order to achieve proper engine pressure for all lines. 1. Place engine on hydrant supply using soft suction. 2. Lay out specified hoselines and correct nozzles from engine. 3. Pump operator will charge line using tank water 4. Lines should flow correct pressure within 10 psi of calculated pressure. 5. Relief valve is set at correct pressure. 6. Supplied source is introduced to system. 7. Tank is topped off and tank valve closed 8. Supply to line to correct pressure and flow using only pressurized intake source. Standard: Pump operator shall charge lines slowly without creating water hammer to within 10 psi of calculated pressure. No calculation of hoseline shall take longer than 1 minute. When all three lines are properly charged, relief valve will be set to maintain pressure. Sample Hose layout 200 of 1 3/4 with a 7/8 smoothbore nozzle Hose layout to be determined by instructor 2

Single Engine / Multiple Line Operations Refresher Evolution #2 Objective: Charging multiple handlines of different lengths, diameters, and GPM s at correct discharge pressurewithout noticeable changes in pressure (+ / - 10psi). Purpose: To gain experience in the techniques of gating and feathering of valves in order to achieve proper engine pressure for all lines. 1. Place engine on hydrant supply using soft suction. 2. Lay out specified hoselines and correct nozzles from engine. 3. Pump operator will charge lines from smallest to largest. 4. Lines should flow correct pressure without loss of pressure as additional lines are charged to within 10 psi of calculated pressure. 5. Relief valve is set at correct pressure. Standard: Pump operator shall charge lines slowly without creating water hammer to within 10 psi of calculated pressure. No calculation of hoseline shall take longer than 1 minute. When all three lines are properly charged, relief valve will be set to maintain pressure. Notes: Instructor should vary length of hand lines for each pump operator completing evolution so that no two operators use same calculations. (add or remove lengths of line or change nozzle types) *Complete the 2 1/2 hoseline portion with both smooth and combo nozzles. 200 of 1 3/4 with a 7/8 smoothbore nozzle 100 of 1 1/2 with a combination nozzle 300 of 2 1/2 hoseline with 1 1/8 smooth bore nozzle Sample Hose Layouts 3

Relay Operations Refresher Evolution #3 Objective: Flow large volumes of water between two engines simulating large lead-out operations. Purpose: To gain experience in relay pumping operations using large diameter hose evolutions. 1. Place engine #1 at a simulate fire scene and prepare to flow large gpm master streams. 2. Second engine will drop a supply line consistent with department sog and lay line (either forward or reverse; reverse preferred) to water supply. 3. Water supply will be established after hydrant is flushed, supply being sent via dropped line at correct pressure and gpm to engine #1. 4. Evolution will be completed when instructor/officer is satisfied with outcome. A. Evolution is not timed, performance is judged by correct gpm and discharge/intake pressures relevant to flow at engine #1. Standard: Pump operators will utilize correct friction loss and flow requirements for scenario presented. Flow should be measured using pitot gauges or other calculating device. Notes: At various times during flow, instructor/officer should vary the flow requirements at engine #1. Increase and decreases of at least 100gpm should be utilized. Make sure proper radio communications between engines takes place. Flow 500+ gpms from any master stream or handline combinations. Supply must match demand Large Diameter Hose preferred 4

Drafting Operations Refresher Evolution #4 Objective: Supply a fire attack operation utilizing portable tanks and tanker shuttle system. Purpose: To gain experience in securing water supply and drafting water from a static source. 1. Place engine #1 at a simulated fire scene and prepare to flow attack handlines at 100 gpm within 5 minutes of arrival. 2. Position engine #2 at a drafting site suitable for tanker operation and portable tank useage. Supply attack engine through 3 line with tank water within 3 minutes of arrival. 3. Position drafting tank and drafting equipment into proper places and dump water into tank Secure ends of equalizer sleeves with clamps (clamp as close to tank as possible) Point equalizer sleeves in uphill position from primary tank Secondary tanks should be positioned in an uphill fashion to allow gravity feed 4. Secure draft using positive displacement pump (primer) or hot draft technique 5. Fill booster tank and supply attack engine. 6. Shut down tank to pump and supply water from static source, booster tank to remain in reserve. 7. Increase flow to 750 gpm when 2 or more tanks are full (use ldh or 2nd 3 line to match relay flow) Tanker Operation: 1. Position apparatus according to water supply officer or 2nd engine operator for quick dump operation. 2. Place portable tank on tarp, assist in set-up and connection of suction and low profile strainer. 3. Dump water from largest volume discharge available if possible. 4. Operate apparatus safely to refill site and prepare hydrant Open and flush hydrant Set up a large diameter refill line and auxiliary 3 lines in opposite directions from each other Fill apparatus and return to dump site 5. Evolution will be completed when instructor/officer is satisfied with outcome. A. Evolution is not timed, performance is judged by correct gpm and discharge/intake pressures relevant to flow at engine #1. B. Preferred GPM flows are 100 gpm within 5 minutes / 500 gpm within 10 min / 750 or greater after 15 minutes or secure tanker set-up Standard: Pump operators will utilize correct friction loss and flow requirements for scenario presented. Flow should be measured using pitot gauges or other calculating device. Notes: At various times during flow, instructor/officer should vary the flow requirements at engine #1. Increase and decreases of at least 100 gpm should be utilized. Make sure proper radio communications between engines takes place. 1 3/4 initial attack line 2 1/2 or master stream for 500 + flow Initial 3 supply line 5 supply for 500 gpm + flow 5

Standpipe / Sprinkler Operations Refresher Evolution #5 Objective: To supply water to a sprinkler / standpipe Siamese connection using one engine and typical supply line hoses. Purpose: To gain experience in securing a water supply, supplying proper pressure to a Siamese connection, calculating friction loss factors and supply of proper gpm to elevated floors. 1. Place engine at simulated fire scene and prepare to flow supply line to Siamese inlet. 2. Secure a positive water supply to engine. 3. Place appropriate lengths of hose to Siamese connection from the engine. A single line may be permitted for initial operation. 4. Determine internal characteristics of structure, i.e. sprinkler only, standpipe only or combination system. 5. Determine where hoselines will be flowing if applicable and calculate correct discharge pressure from engine. 6. Charge supply line at correct pressure to Siamese, monitor effectiveness of flow via interior operations sectors. Evaluation Options 1. Identify the components of the high rise pack. (Length, hose size, nozzle type, accessory equipment, and identify each components friction loss factor.) 2. Discuss or demonstrate the trouble shooting operations if interior / exterior riser components fail. 3. Discuss the friction loss factors in the entire system. Standard: Pump operator will utilize correct friction loss and flow requirements for scenario presented. Flow should be measured using pitot gauges or other calculating devices. Evolution should be completed within 4 minutes. Notes: Optimal flow rates of 500 gpm would be preferred in a real fireground application but could be difficult to reproduce in training scenarios. References: SUFD NFPA 1410 Evolutions Module 12 Department SOG for High Rise or Sprinkler/Standpipe Operations 500 GPM Total Supply Line Supply Line(s) Using a simulated sprinkler system, one engine, one supply line for hydrant hook-up and supply line(s) for siamese connection, company shall establish a water supply to standpipe/sprinkler connection within 4 minutes. 6

Foam Operations Refresher Evolution #6 Objective: To perform the proper sequence of steps to safely place an initial foam line in service, using units and staffing of the average number of personnel that ordinarily respond. Water supply shall be established with a 5 suction hose {minimum} using a hydrant water source. Purpose: To demonstrate the ability to create a single line foam stream using an in-line eductor and foam nozzle (or attachment). 1. Deploy {minimum} of 200 of 1 ¾ hose for foam line. 2. Engine shall be on water supply (hydrant) within 4 minutes of flowing water. 3. Attach in-line eductor no further than 100 from eductor position. 4. Secure foam concentrate (training foam acceptable) and open container. 5. Flow water through hoseline. 6. Place pick-up tube into container. 7. Change selector to foam, select appropriate % for evolution (3%) 8. Apply foam blanket according to IFSTA essentials or dept. SOG. 9. Shut down all lines, clean foam equipment according to manufacturer recommendations. Standard: Pump discharge pressure should be 200 psi at eductor. Evolution should be completed in 4 minutes or less. Notes: Check dept. SOG and manufacturer recommendations on pump discharge pressures prior to completing this evolution. Clean all equipment thoroughly. 5 200 line eductor 7

Road Test Refresher Evolution #7 Objective: To provide for annual road test evaluation of a driver operators ability to operate units assigned in a nonemergency capacity over a given road course providing specific evaluation criteria within road course. Purpose: To ensure basic skill level maintenance levels are established and maintained to improve operator and passenger safety during vehicle travel. 1. Demonstrate pre-trip inspection procedures for apparatus. -Daily / weekly / monthly check procedures -Documentation of check-out procedures -Safety related behaviors prior to operation 2. When instructed by evaluator (or designee) operator will operate vehicle over assigned road course. 3. Complete road course as instructed and return apparatus to service. Standard: Apparatus operator will be evaluated according to JPR schedule on rating of 1 to 5 points with 5 being the highest level of performance. A minimum score of 3 will be required on each apparatus assigned to operate. Scores of 1 or 2 will require additional training and re-evaluation. Notes: Department will assign apparatus required for road test according to like-apparatus principle. If vehicle are significantly different in specification, operation, age or other factor, then each vehicle must be road tested. If vehicles are significantly alike, 1 road test per type of apparatus may be assigned. Unit # Vehicle Startup + Prestart Familiarity w/controls & gauges Smooth & efficient acceleration Correct use of clutch & gears Smooth, efficient braking Down shifting technique* Proper use of auxiliary braking devices* Correct cornering technique Ability to back vehicle Frequent use of mirrors Frequent check of gauges Adheres to safety procedures Responds appropriately to evaluators commands Reacts appropriately to changes in conditions Pump operations evaluation completed General ability to operate and knowledge of unit Evaluators Initials / Total Points Date Rating Performance Evaluation Key 1 Unacceptable Additional Training Required 2 Performance meets JPR s but inconsistently Training recommended Complete PIA 3 Performance meets JPR s 4 Performance meets and occasionally exceeds JPR s 5 Performance consistently exceeds JPR s Sample Evaluation Key and Criteria 8

Aerial Ladder Operations Refresher Evolution #8 1 3 Evolutions 2 1. Set-up for Rescue 2. Set-up for Roof Access 3. Set-up for Master Streams Objective: Operate aerial ladder device in a variety of emergency operations situations Purpose: To gain experience in operations using aerial devices. 1. Apparatus will be properly positioned for placement to assigned evolution objective; master stream, window operations, roof access. 2. Operator will set all jacks according to SOG s. 3. Operator will set-up aerial device according to SOG s. 4. Operator will raise, rotate and extend ladder toward objective in as few motions as possible. 5. Ladder will be positioned for work according to objective 6. Apparatus will be placed back into service. 7. Evolution will be completed when instructor/officer is satisfied with outcome. A. Performance is judged by correct apparatus placement, set-up of aerial ladder, use of device and overall safety of the evolution performed. Standard: 1. Check proper chocking of apparatus 2. Check for safe elevation for set-up 3. Sets jacks and pads correctly 4. Proper switchover of hydraulic system 5. Checks for overhead obstructions before moving ladder 6. Properly unbeds ladder from nested position 7. Raise, rotate and extend ladder to objective* *Less than 5 operations to objective preferred Notes: At various times during evolution, instructor/officer should add additional operational objectives to the evolution to complete all three tasks. Each task is measured individually. All manufacturer recommendations for operations must be adhered to during all phases of the operation. 9