Three Lakes Association Hydrolab for Dummies. Table of Contents:

Similar documents
Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

QUICK START GUIDE TO DRINKING WATER MONITORING

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Experiment C-6 Gas Solubility

BI-680 Online Dissolved Oxygen Controller Instruction Manual

SS32L Dissolved O 2 Probe

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Euclid Creek Volunteer Watershed Monitoring Program Directions for Performing Physical/Chemical Tests

EC214 EC215 - EC215R Bench Conductivity Meters

Optical Dissolved Oxygen Meter

NEULOG OXYGEN LOGGER SENSOR GUIDE

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

Aerobic Respiration. Evaluation copy

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

DO_maint-cal Page 1 of 13

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Heavy Duty Dissolved Oxygen Meter

HI 9143, HI 9143M HI 9145

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

PRODUCT SHEET. Order probe only as RXPROBE02

User's Guide. asics FLOW CELL MODELMP20. Part No REV. # P.O. Box 3726, Ann Arbor, MI USA

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

YSI-85_maint-cal Lab Version Page 1 of 13

STANDARD OPERATING PROCEDURE MAINTENANCE/CALIBRATION CHECKS OF DISSOLVED OXYGEN PROBES

YSI Model 550a Dissolved Oxygen (DO) Meter

Dissolved Oxygen/Temp Waterproof Tester

Hydrolab DS5X, DS5, and MS5 Water Quality Multiprobes

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

COOPERATIVE LAKES MONITORING PROGRAM TRAINING FOR. Dissolved Oxygen and Temperature

Flashlight. Hand Lanyard. 36 Super Bright LED Bulbs. Sensor

Optical Dissolved Oxygen Meter

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

HI 2314 HI 2315 HI 23151

FIELD PROCEDURE: WATER CHEMISTRY

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Table of Contents 1 Introduction 2 Technical specifications 3 Included in the delivery 4 Function description 5 Mounting Nortek AOS buoy

YSI ProDSS calibration and routine maintenance rev 5/29/2018

APA software instruction manual

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

UsER manual for Watersens ph -REDOX

QA Approval - William R. Kammin, Ecology Quality Assurance Officer Date -

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Oxygen Sensor with Electrode

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

9408 series Dissolved oxygen systems

Calibration and Maintenance Procedures: YSI ProDSS rev 8/31/15

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Using the UltraRAE. Firmware 2.35

asics Low-Flow Purging Procedure with MicroPurge Basics Equipment First in Control & Power For Low-Flow Sampling

ANALOX O2 PORTABLE OPERATORS MANUAL

6-SERIES ENVIRONMENTAL MONITORING SYSTEMS. Service Manual

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Instruction Manual. Multiparameter Benchtop Meter

Environmental Monitoring Systems 6-SERIES

Instruction Manual Series Benchtop Meters. ph 2700 ION 2700 CON 2700 DO 2700 PC Technology Made Easy...

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

LVU2800 Series. Ultrasonic Level Transmitter

SDX Submersible Depth Transmitter User Manual

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

DISSOLVED OXYGEN SENSOR BT34i

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Instruction Manual SWIMMINGPOOLCHEMICALS.CO.UK

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

YSI Model 52 Dissolved Oxygen Meter

Vinmetrica Dissolved Oxygen System User Manual

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

YSI Model 63. Handheld ph, Conductivity, Salinity and Temperature System. Operations Manual

Met One E-BAM Particulate Monitor

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

HI 9932 Autoranging Bench Microprocessor EC/TDS/NaCl/ C Meter

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

CCPaSEC. Procedure for the Quality Control Yearly Equipment Check. July 2018 CCPaSEC Quality Control Team

Oxygen Measurement Systems High Reliability and Wide Application Coverage

PRO20 USER MANUAL. English. Français. Español. Deutsch

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

SDX Submersible Depth Transmitter User Manual

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Relative Humidity Calibration Kit

O2 Portable. User Manual

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Sterisil Ac+ Installation & Operating Manual

Transcription:

Three Lakes Association Hydrolab for Dummies 1 Table of Contents: 1. Know before you start:...2 a-introduction b-unpacking c-general use d-be careful 2. Calibration:...3 a-step by step guide 3. Using the Hydrolab:...4 a-contents b-display Buttons c-screens/screen Icons d-set up icon e-store icon f-review icon 5 g-using the Hydrolab 4.Storing the Hydrolab:...6 a-specific Storing instructions

Know before you start: 2 Introduction The Quanta Hydrolab is a system used to monitor water quality. It is most commonly used to measure the Temperature, ph, Dissolved Oxygen (DO), Specific Conductance (SpC), and depth of a specific body of water. While the Quanta Hydrolab is predominantly used in larger bodies of water, it can be used to determine water quality in anything from lakes, rivers, and streams to process pipes, bays, estuaries, tanks, aquaria, and sewers. Data can be collected over a long or short period of time. Unpacking Our Hydrolab is stored in a large plastic camping cooler. It must always be returned to this cooler after use. When one opens the cooler one will find that the membrane end of the Transmitter is submerged in either deionized (distilled) or tap water. In order to keep the hydrolab functional the membrane end of the Transmitter must always be submerged, especially while being stored in between uses. The display, storage/calibration cups, 100 meter cable, and calibration fluids can also be found inside the cooler. General Use Before every use the hydrolab must be calibrated. If one fails to complete this task (which is described in detail in the next section) the data displayed will be extremely inaccurate and misleading. After one has calibrated the hydrolab he or she is ready to begin making measurements. In order to do this one will drop the Transmitter into the water and lower it to the desired depth. Another person should be holding the display. The display will tell that person all the different values for temperature, ph, depth etc. Once one has made all the desired measurements he or she is ready to pack up the hydrolab. Detailed instructions describing how to properly do this can be found in the Storing the Hydrolab section of this manual. Be Careful The Quanta Hydrolab is an expensive piece of equipment that was gifted to the Three Lakes Association a few years ago. Please make sure to handle it with care. The membranes at the end of the transmitter should not be touched. Also remember to never lower the hydrolab into the water without the protection cap. Failing to attach the cap can cause damage to the membranes which would result in inaccurate readings.

Calibration: 3 1 2 3 4 5 6 7 8 9 10 11 12 Hydrolab Quanta Calibration: 1. Remove the storage cup and replace with the calibration cup. (1) 2. Rinse the calibration cup one or two times by filling the cup half-way with deionized water and shaking vigorously for several seconds. Try to remove as much fluid as possible from the cup after each rinse. 3. Use two or more calibration solutions that bracket anticipated conditions. Refer below for how to calibrate specific measurements.(2)

4 4. Carefully fill the calibration cup with the calibration solution until the probe is immersed. Shake vigorously for several seconds (except for DO). 5. Wait for the parameter reading to stabilize. Check to see if the reading is close to the calibration reading. If the reading is acceptable, record the calibration reading. If the reading is not acceptable, proceed to the calibration screen and enter the calibration solution concentration. In some circumstances, the unit will not accept the new calibration setting because of a problem with either the calibration solution or the unit. To see if the problem is the calibration solution, use a different calibration solution. If the problem is with the unit, try to find the source of the problem (faulty sensor, low battery, mistyped standard value, incorrect units, etc.). 6. Dispose of the calibration solution, followed by one or two rinses with deionized water. Remove and store the calibration cup. 7. Fill the storage cup half-way with fresh tap water, and place it over the probe assembly. Specific Conductance: The first solution should be deionized water, SpC 0, and the second should be a calibration solution, such as SpC = 40 S/cm = 0.04 ms/cm. (3,4) ph: The first solution should be lower than the typical measurement such as a ph = 7 buffer solution, and the second should be higher than the typical such as a ph = 10 buffer solution. (5,6,7,8) Dissolved Oxygen: Fill the Calibration Cup with deionized or tap water (specific conductance less than 0.5 ms/cm) until the water is just level with the o-ring used to secure the membrane.(9) Carefully remove any water droplets from the membrane with the corner of a tissue. Turn the black calibration cup cover upside down (concave upward) and lay it over the top of the Calibration Cup. (10,11) Determine the barometric pressure for entry as the calibration standard. (12)

Using the Hydrolab: 5 Contents of the Hydrolab Three Covers: storage cup, Guard cover, and Calibration Cup 100 meter attached cable Display screen Transmitter Sensor End Dissolved Oxygen and ph Maintenance Kits 3 C Alkaline Batteries (life span of 20 hours with Propellor operating and no turbitiy) The hydrolab transmitter can measure temperature, ph, dissolved oxygen (DO), specific conductance (spc), depth, Oxidation Reduction Potential (ORP), Turbitiy, Total dissolved solids (TDS), and Salinity. FIve Display Buttons (In order Top to Bottom) This Arrow Key is the enter/select key for the screen icons Esc/Propellor Key this key will bring the display back to the previous or main screen when pressed. This button can also turn on and off the propellor on the transmitter end. When the propellor is turned on an icon will appear on the screen. Toggle Key for up and left Toggle key for down and right On/Off display key which should be held till the transmitter screen turns on or off Screens/ Screen Icon The display has two screens. Screen one will show the spc, temperature, DO, ph, and depth. Selecting the SCREEN icon will show screen two. Screen two presents the battery voltage, salinity, DO (Percent Saturation), ORP, and turbitity. Setup Icon Selecting the SETUP icon will allow you to change the temperature, Salinity, TDS display, and depth Units. Store Icon By toggling over on the main screen and selecting STORE the hydrolab will capture the current readings in its memory. It will then allow you to toggle through the information that was selected for storing, if it is correct press the enter key, the top button. If the information is not correct and you do not wish to store it then press the Esc Key. If the screen reads FAIL then the memory on the hydrolab is most likely full the Review Icon will allow you to clear the memory for more space.

6 Review Icon The REVIEW icon the on hydrolab will show you the previous data stored. Toggling through Headings, Parameters, Digits, and Units selections will present the data screens of the most recent data stored. Use the arrow keys to see older information stored. By pressing the Esc Key the hydrolab display will show Clear/Clear All option. Pressing enter will erase the frames stored. Using the Hydrolab To use the hydrolab put the guard cap on the transmitter end to protect the sensors. Turn on the hydrolab, calibrate it, and rinse off the calibrating solutions. The hydrolab can then be lowered hydrolab into a body of water at any desired depth (keep the hydrolab above the bottom) where you will be taking the measurements. The display will show the current readings. Turn on the propellor for a few seconds then off again, record the data then pull the hydrolab back up. Check to make sure that the propellor did not collect any weeds and the guard does not have sediment in it from contact with the bottom. Storing the Hydrolab: Fill the DS4 storage cup or MS cup with one inch of clean tap water and screw the cup on the multiprobe. Lay the cable in coils of at least 6 inches (15 cm) in diameter at the bottom of the plasticcontainer.place the multiprobe in Hydrolab s custom carrying case or in the center of the container on acircular piece of foam rubber for shock protection. Your multiprobe cables are important components of your water quality monitoring system. They have been designed to be lightweight, portable, and durable. These cables serve two functions. First, raising, lowering, or deploying your multiprobe, and second, connecting your instrument with the surface computer and providing power and data transfers. Protect all nonwaterproof cables (i.e. all cables except the waterproof underwater cable) from any water source during operation in the field. Keep all connectors dry at all times.