Variable area flowmeter F VA 250

Similar documents
SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

GA24 Technical Datasheet

SITRANS P measuring instruments for pressure

Liquid level instruments BM 24 /BM 51

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

FVA Trogflux variable area flowmeter. Operating Instructions. MECON GmbH 05/2013 OI_FVA_Trogflux_EN

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Liquid level switch BM 34

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

High-performance submersible pressure transmitter For level measurement Model LH-10

Electronic Turbine Meter TERZ 94

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

FVA Tubux M30 Variable Area Flowmeter. Operating Instructions. MECON GmbH 07/2013 OI_FVA_Tubux_M30_EN

Mass Flow Controller (MFC) for Gases

Pressure Measurement Single-range transmitters for general applications

Glass tube flowmeters Series 2000

OPTIBAR P 1010 C Technical Datasheet

RMG Meßtechnik GmbH. Publication No E

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Variable Area Flow Meters

Level transmitter LT 100

Measurement of Low GAS & Liquid Flows

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

C-Flow Coriolis Mass Flow Meters

VA40 - VA45 Technical Datasheet

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

deltaflowc deltaflowc Venturi or Probe

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Mass Flow Meter (MFM) for gases

Flow Measurement SITRANS F C

Variable Area Flow Meters

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Torque Tube TB300 Digital Transmitters

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Flow metering in gases Introduction to COMBIMASS family

Bourdon tube pressure gauge for diaphragm seals

Mechanical Pressure Measurement

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure transmitters EMP 2

Orifice Plate Flow Meter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Gas density monitor With integrated transmitter Model GDM-100-TI

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Magnetic level switch type MR783 Instruction Manual

Expert Hydrostatic Level Transmitters

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Variable Area Flow Meters. VS Series

Technical Information Conducal CLY421

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

KOBOLD KSM FLOWMETER. User Instructions

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Controllers DR, DP, FR and DFR

Mass Flow Controller (MFC) for Gases

Installation and Operating Instructions Bypass Flow Meter DST

Pressure Reducing Valve DMV 750 set range: bar

Level MEASUREMENT 1/2016

Product Catalogue. P-SERIES Pressure Gauges

Model PDT Dewpoint Transmitter

SPD310/SPD360 Air Differential

Instruction Manual Differential Pressure Transmitter

Model 130M Pneumatic Controller

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

How to specify a product. Process Sensors and Mechanical Instruments

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure Transmitters 36 F-27839

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

AMS 6916 Board mount pressure sensor with ratiometric analog output

Instruction Manual Differential Pressure Transmitter

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Integral type Differential pressure flowmeter VNT Series

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Technical Manual. Liquid Level Transmitter CT801-LB/S

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

SonoMeter 30 Energy Meters

Precision pressure sensor Basic version Model CPT6020

AMS 2710 PCB pressure sensor module with V output

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Differential pressure

Pressure Reducing Valve DMV 750

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

200A Series ELECTRONIC LEVEL TRANSMITTER

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

sitrans p Operating Instructions (de/en) Edition 03/2004

SITRANS P measuring instruments for pressure

RCD - Ultra-Rugged Differential Pressure Flowmeter

9700 Transmitter Submersible hydrostatic level transmitter

[Instruments for vacuum measurement, checking and adjustment] 3

Pressure Measurement Single-range transmitters for general applications

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Instructions Manual. Variable Area Flow Meter SC-250. Series

Transcription:

Fig. variable area flow meter pplication The V 5 variable area flowmeters with a standard length of 5 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that they can also be used in rough conditions. ifferent types of flanges, liners and float materials satisfy the requirements of the pharmaceutical and chemical industries. The measured value is displayed directly on the scale, and output via a switch contact or as a current output. The main applications for the V 5 can be found in the following fields: Chemical industry Water Power generation and distribution. Special features Standard design available at short notice Robust all-metal fitting with impact-resistant housing cover Can also be used for corrosive and flammable media Use possible at high pressures and temperatures Product and percentage scales Can be optionally fitted with heating and cooling sheaths Contamination-insensitive guiding of float. esign and mode of operation Fig. Flow tube/scale angle Note of application The operator of these measuring instruments is responsible for suitability, proper use and corrosion resistance of the used materials with regard to the measuring material. It must be ensured that the materials selected for the flowmeter parts in contact with the medium are suitable for the used process media. No external loads may act on the meter. Provide a touch guard for surface temperatures of > 7 C. This touch guard must be designed in a way that the max. allowable ambient temperature on the unit is not exceeded. The flowmeter may only be used within the pressure and voltage limits specified on the identification plate. Before replacing the measuring tubes, check that the unit is free of hazardous media and pressures. The measuring instruments are primarily designed for static loads. Classification according to P 97//G Permissible media 7M58-7M58- N 5 xxxx-xxxx Gases and liquids of fluid group N 5 xbxxx-xxxx Gases and liquids of fluid group N 5 xcxxx-xxxx Gases and liquids of fluid group N 8 xxxx-xxxx Gases and liquids of fluid group N xxxx-xxxx Gases and liquids of fluid group Category rt.. rt.. III III III The V 5 operates like the other units in the V range according to the variable-area flow tube principle: the flowing medium lifts the conical float in the flow tube. The annular gap is then increased until equilibrium exists between the buoyant force of the medium and the force due to the weight of the float. The height of the float is directly proportional to the flow quantity. The movement of the float is transmitted by a magnet to a slave magnet in the display unit outside the flow tube. The contacts or the electric remote sensor are controlled by a contact lug or a cam which is mounted on the pointer shaft. Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

Technical specification pplication see page esign and mode of operation see page Measuring principle variable-area flowmeter Input Measuring range see tables on page Pressure rating Flow imension for measured variables Rated operating conditions Mounting mbient temperature Medium conditions ccuracy Temperature of medium Viscosity limits PN (MWP 45 psi) to PN4 (MWP 58 psi) depending on version (see Tables on page and 4) vertically upwards l/h, from 4. l/h (7,6 USgpm) in m³/h vertical <8 C (76 F) <7 C (58 F) with contact display ± % of full-scale value (±,6% as option, but not for liner) max. 5 C (57 F) ( C (57 F) as option) Q max [m /h] Q max [USgpm] Viscosity [mpa.s] (cp),,44, >, to,5 >,44 to,, to, >,5 to >, to, to 5, > to > to 44, to 8, > to 5 > 44 to, to > 5 to 5 > to, to 5 > 5 to > to 44, to 5 > > 44, to 5 Technical specification F V 5 (magnet spring contact) Switching principle Magnet spring contact, twin contact Connection ppliance plug to IN 465 Max. switching frequency Max. rating Hysteresis mbient temperature F V5 (inductive contact) Switching principle 5/min Connection PG Rated voltage C 5V / / 5V C 5V / / W Rating data apply to resistive loads; a suppressor circuit is required for inductive loads ± % of full-scale value - to +7 C (-4 to 58 F) Inductive contact, single contact; twin contact as option..8v C Self-inductance 5µH Self-capacitance mbient temperature without X-protection F Va 5 (electric remote sensor, current output) Principle Connection Power supply 8 nf - to +7 C (-4 to 58 F) Rotation angle transmitter -, - or 4-wire system C to V esign Flanges Material Fitting Float Wetted parts materials egree of protection (display unit) IN, NSI Stainless steel.457/ Stainless steel.457/, Hastelloy, Titanium, luminium Stainless steel.457/,, C.8, Hastelloy depending on version IP65 Self-capacitance Short-circuit current Output -wire system -and 4-wire systems Load mbient temperature without X-protection < nf max. 6m 4 to m to m max. 9Ω at V - to +7 C (-4 to 58 F) Fig. F V 5 rotation angle transmitter, connection diagrams Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

Measuring ranges for liquids Version F-S CF-S CF-K F-H FF-P ¹ ) Wetted parts mat. C.8 mat.no..457/ / Hastelloy C Fitting mat.no..457/ Flange C.8 Float/flow tube mat.no..457/ with liner with liner Hastelloy Max.temperature of medium 5 C (57 F) optional C (57 F) 5 C (57 F) optional C (57 F) 5 C (57 F) optional 6 C ( F) 8 C (76 F) 5 C ( F) Connection IN5 Nominal pressure N5 to N8/ (/ to inch): PN4 (58 psi) N (4 inch): PN6 ( psi) N5 to N8/ (/ to inch): PN4 (58 psi) N (4 inch): PN6 ( psi) N5 to N5 (/ to inch): PN4 (58 psi) PN6 ( psi) PN6 ( psi) N 5 N 5 N 5 N 8 N Full-scale value Flow tube l/h (USgpm) 6 (,7) x 5 (,) B x 4 (,8) C x 6 (,8) x (,44) x 6 (,7) F x x Nominal diameter l/h (Usgpm) 5 (,) G x x x N5-5 (/- inch) 5 (,) 4 (,76) H x x x N5-5 (/- inch) 4 (,76) 6 (,77) J x x x N5-5 (/- inch) 6 (,77). (4,4) K x x x N5 ( inch). (4,4).6 (7,) L x x x N5 ( inch).6 (7,).5 (,) M x x x N5 ( inch).5 (,) 4. (7,6) N x x x N5 ( inch) 4. (7,6) 6. (7,7) P x x x N5 ( inch) 6. (7,7). (44) Q x x x N5 ( inch). (44) 6. (7) R x x x. (88) S x x x 5. () T x x x N8- (-4 inch) 5. () 4. (76) U x x x 5. () V x x x 6. (77) W x x x. (44) X x x ) For the FF-P version, only the measuring ranges of the listed nominal diameters are possible Nominal diameter Pressure loss mbar (psi) N 5 (/ inch) 6 (,87) N 5 ( inch) 6 (,87) N 5 ( inch) 9 (,) N 8 ( inch) 6 (,) N (4 inch) 4 (,5) Measuring ranges and pressure losses for liquids (density ρ= kg/l (6,4 lb/cu.ft) and viscosity mpa.s(cp)) with standard scales. The dynamic range is always :. Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

Measuring ranges for air Version CL- CL-T CL-K L-T FL-R Wetted parts mat. Fitting mat.no..457/ luminium, Titan mat.no...457/ / Hastelloy C, Titanium mat.no..457/ Flange with liner with liner Float/flow tube Max. temperature of medium luminium/ 5 C (57 F) optional C (57 F) Titanium 5 C (57 F) optional C (57 F) 5 C (57 F) optional 6 C ( F) Titanium/ Hastelloy 8 C (76 F) 5 C ( F) Connection IN5 Nominal pressure N5 to N8/ (/ to inch): PN4 (58 psi) N (4 inch): PN6 ( psi) N5 to N8/ (/ to inch): PN4 (58 psi) N (4 inch): PN6 ( psi) N5 to N5 (/ to inch) PN4 (58 psi) PN6 ( psi) PN6 ( psi) N 5 N 5 N 5 N 8 N Full-scale value Flow tube m³/h (USgpm),5 (.94) X, (.589) B X,6 (.94) C X,5 (.47) X 4, (.5) X, (7.6) F X X X X 6, (9.4) G X X X X 5, (4.7) H X X X 5, (4.7) H X 4, (.54) J X X X X 6, (7.8) K X X X X, (58.86) L X X X, (58.86) L X 6, (94.7) M X X X X 5, (47.) N X X X 4, (5.4) P X X X 4, (5.4) P X 6, (7.8) Q X X X Nominal diameter Pressure loss mbar (psi) Minimum inlet pressure mbar (psi) N 5 (/ inch) 4 (,58) 5 (7,5) N 5 ( inch) 4 (,58) (,45) N 5 ( inch) 65 (,94) (,45) N 8 ( inch) 8 (,6) (,45) N (4 inch) 8 (,6) (,45) Measuring ranges and pressure losses for air (p abs=, bar (4,69 psi) at T= C (68 F)). The dynamic range is : for each flow tube. Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page 4 to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

Installation and operating instructions The main information for installation and startup is listed below. Further information can be obtained from VI/V 5, sheet, installation recommendations for variable area meters. Installation instructions The variable area meter is delivered protected in a PVC sleeve, and is ready for operation. It has been checked for correct functioning prior to delivery. Before installing, check that the float moves freely: the float must slide smoothly in the flow tube without sticking or tilting. The pointer must smoothly follow the movement of the float. In the rest position (zero flow), the pointer must point to the marked reference point (first scale line). In the end position of the float, the pointer must be positioned above the full-scale value. The variable area meter must be fitted into the piping vertically and without tension. Magnetic fields from other equipment may influence the result. If several variable area meters are installed next to one another, the following minimum distances must be observed between the main axes of the variable area meters: N 5 to 5 (½ to inch): 5 mm (9.84 inch) N 8 to ( to 4 inch): 4 mm (5.74 inch). The flange screws of the -lined fittings must only be tightened with the following maximum torques: N 5 to 5 (½ to inch): 4 Nm N 5 ( inch): 5 Nm N 8 ( inch): 5 Nm N (4 inch): 4 Nm Interference-free inlet and outlet pipe sections are not usually required. However, additional measures (inlet pipe sections, flow stabilizers) may be meaningful to retain the measuring accuracy in the case of highly asymmetric flow profiles. To prevent pulsations resulting from compression when measuring gases, a throttle should be positioned directly downstream of the variable area meter. To avoid faulty measurements, the arrangement should be selected such that the pressure in the variable area meter corresponds to the reference pressure for the calibration. The flowmeter may only be used within the pressure and voltage limits specified on the identification plate. Startup. When starting up new plants, material residues (e.g. welding spatter) are carried over in the medium and could be deposited on the variable area meter. In such cases it is recommendable to clean the variable area meter after a short period of operation.. The float must not be exposed to sudden pressures. It is therefore recommendable to start with a closed valve which is then slowly regulated to the operating pressure. Liquids should be vented carefully to prevent pressure surges resulting from gas bubbles.. The variable area meter outputs values in all scale ranges according to its accuracy class. ach time a flow is started, permit the variable area meter to settle. When measuring in the lowest range, initially set a higher flow for a short time. Maintenance and repair epending on the medium, contamination, abrasion or chemical reactions may attack the orifice and the float, thus influencing the accuracy of the measurement. In such cases it is recommendable to dismount the variable area meter and to clean it, including the float, with appropriate agents. The orifice and float must not be damaged mechanically or by aggressive cleaning agents. If erosion is noticed on the orifice or float, recalibration or replacement is necessary. Following all maintenance and cleaning operations, carry out a function test of the variable area meter before using it again. Nconnection imensions in mm (inch) Versions Weight F-S, CF-S,CF-K F-H, FF-P, kg (lb) CL-, CL-T, CL-K L-T, FL-R 5 (/inch) 86 (,4) 89 (,5) 4 (8,8) 5 ( inch) 9 (,6) 96 (,8) 5 () 5 ( inch) 9 (,6) (4,4) 9 (9,8) 8 ( inch) 5 (4,9) (5,) (8,7) (4 inch) 8 (5,4) 8 (5,4) 5 () Fig. 4, dimensions in mm (inch) Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page 5 to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

variable area meter, made completely of metal for measurement of liquids 7M58- - variable area meter made completely of metal for measurement of liquids 7M58- - Version Type F-S (standard) Fitting: stainless steel.457/ Flange: steel C.8 Float: stainless steel.457/ Type CF-S (standard) Fitting: stainless steel.457/ Flange: stainless steel.457/ Float: stainless steel.457/ Type CF-K Fitting: stainless steel.457/ Flange: stainless steel.457/ Float: stainless steel.457/ Type F-H 4 Fitting: stainless steel.457/ Flange:.457/ with liner Float: Hastelloy Type FF-P 5 Fitting: stainless steel.457/ Flange:.457/ with liner Float: Norm.diam./flange connection N5 (/" NSI) N5 (" NSI) B N5 (" NSI) C N8 (" NSI) N (4" NSI) Flow tube Size Full-scale value l/h (Usgpm) 6 (,7) B 5 (,) B C 4 (,8) C 6 (,8) (,44) F 6 (,7) F G 5 (,) G H 4 (,76) H J 6 (,77) J K (4,4) K L 6 (7,) L M 5 () M N 4 (7,6) N P 6 (7,7) P Q (44) Q R 6 (7,4) R S (88) S T 5 () T U 4 (76) U V 5 () V W 6 (77) W X (44) X Flange connection standard N9- (standard) NSI B 6.5 Special connections (thread or 9 other pressure stages) Temperature shield With temperature shield 5 to C (57 to 9 F) With displaced display to C (9 to 57 F) see right LY Heating/cooling sheath see left H/K with flange connection H/K without flange connection isplay With local display (standard) With magnet spring contact F V 5 With inductive contact F V 5 With electric remote sensor F V 5 ( bis m) With electric remote sensor F V 5 (4 bis m) Contact function No contact (standard) For magnet spring contact (twin contact): open on upward violation of limit For inductive contacts: Open on downward violation of limit Close on downward violation of limit open on upward violation of limit Calibration Standard calibration Without calibration certificate With calibration certificate Special calibration 9 R Y (,6% accuracy) Further designs Please add "-Z" to and specify (s) cceptance test B to C IN549, Section.. and N4 Measured medium, specify in Y plain text (always required): Medium, measuring range, dimension, density, density dimension, viscosity, viscosity dimension, operating temperature, operating pressure Silicone-free version Water as measured medium Y 4 Y 5 Viscosity: mpas (cp) ensity: kg/l (6,4 lb/cu.ft) Stainless steel tag plate Special version: Y 7 Y 9 9 specify in plain text Note:See table on page for possible combinations of nominal diameters and flow tube. Teletransmitters and contacts cannot be ordered simultaneously. B C G H J K L M N P Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page 6 to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen

variable area meter, made completely of metal, for measurement of gases 7M58- - variable area meter made completely of metal for measurement of gases 7M58- - Version Type CL- Fitting: stainless steel.457/ Flange: stainless steel Float: aluminium Type CL-T Fitting: stainless steel.457/ Flange: stainless steel.457/ Float: titanium Type CL-K Fitting: stainless steel.457/ Flange: stainless steel.457/ Float: stainless steel.457/ Type L-T 4 Fitting: stainless steel.457/ Flange:.457/ with liner Float: titanium Type FL-R 5 Fitting: stainless steel.457/ Flange:.457/ mit liner Float: Nom.diam./flange connection N5 (/" NSI) N5 (" NSI) B N5 (" NSI) C N8 (" NSI) N (4" NSI) Flow tube Size Full-scale value m³/h (Usgpm),5 (,) B, (4,4) B C,6 (7,4) C,5 (,) 4, (7,6) F, (5) F G 6, (7) G H 5, () H J 4, (76) R K 6, (77) J L (44) K M 6 (74) L N 5 () M P 4 (76) N Q 6 (774) P Flange connection standard N 9- (standard) NSI B 6.5 Special connections (thread or 9 other pressure stages) Temperature shield With temperature shield 5 to C (57 to 9 F) With displaced display to C (9 to 57 F) see right LY Heating/cooling sheath H/C with flange connection H/C without flange connection isplay With local display (standard) With magnetic spring contact F V 5 With inductive contact F V 5 With electric remote sensor F V 5 ( to m) With electric remote sensor F V 5 (4 to m) Contact function No contact (standard) For magnet spring contacts: open on upward violation of limit For inductive contacts: Open on downward violation of limit Close on downward violation of limit open on upward violation of see left Calibration Standard calibration Without calibration certificate With calibration certificate Special calibration 9 R Y (,6% accuracy) Further designs Please add "-Z" to and specify (s) cceptance test B to C IN549, Section. and N4 Measured medium, specify in Y plain text (always required) Medium, measuring range, dimension, density, density dimension, viscosity, viscosity dimension, operating tempera- ture, operating pressure Silicone-free version Stainless steel tag plate Special version: Y 4 Y 7 Y 9 9 specify in plain text Note: See table on page 4 for possible combinations of nominal diameters and flow tube. Teletransmitter and contacts cannot be ordered simultaneously. B C G H J K L M N P Mecon GmbH Phone +49()4 469 Fax +49()4 469 4 Page 7 to 7 Zieglerstraße 6 www.mecon.de info@mecon.de Mecon 4/5-578 achen