Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Similar documents
Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell. Slave sensor for electronic differential pressure

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell. Slave sensor for electronic differential pressure

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60

Operating Instructions VEGADIF 65

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Operating Instructions VEGADIF 65. Differential pressure transmitter with metallic measuring diaphragm. Profibus PA. Document ID: 36129

Declaration of Conformity as per Directive 97/23/EC

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Declaration of Conformity as per Directive 97/23/EC

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Installation and Maintenance Instruction Manual

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Operating Instructions VEGAFLEX 65

Siphon vessel / Priming aid

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Operating Instructions VEGAFLEX C, PFA insulated

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure maintenance valve SDV-P / SDV-P-E

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

PV4 and PV6 Piston Valves

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Installation & Operation Manual Proven Quality since 1892

Endura AZ40 Sensor assembly High temperature filter assembly kit

Pressure relief valve

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Pressure Reducing Valve DMV 750 set range: bar

Operating Instructions Process pressure transmitter IPT-1* Vers metalic sensor Foundation Fieldbus

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Operating Instructions VEGACAL 65

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGASWING SG51, SWING61, SWING63 Hygienic process fittings. Document ID: 35487

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Steam Trap BK BK 212-ASME. Original Installation Instructions English

OPERATING INSTRUCTIONS

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Product information Vibrating

Bladder Damper PP/PVC

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Pressure relief valve

FPD175 Compact orifice carrier assembly

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Installation and Maintenance Instruction Manual

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

MAINTENANCE AND OPERATING MANUAL

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

Non-Return Valve SRK 22A

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Instruction Manual Contact Pressure Vacuum Gauge

TP1 and TP2 Temporary Cone Shaped Strainers

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Flowmeter. Original operating manual DFM

Operating and maintenance manual Filter and reducing station Series / 1.0

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

ATS430 turbidity sensor Retractable insertion assembly

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Operating Instructions VEGASON 62 Foundation Fieldbus

Float Operated Level Controllers

Type overview. R B2 en-gb subject to changes 1

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

MP-F05, MP-F05/R, MP-F10, MP-F10/R

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Type BBS-03, BBS-05, BBS-06, BBS-25

ITT RICHTER CHEMIE-TECHNIK

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure Relief Valve DHV 718

Transcription:

Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027

Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your safety 2.1 Authorised personnel... 4 2.2 Appropriate use... 4 2.3 Warning about incorrect use... 4 2.4 General safety instructions... 4 2.5 Safety label on the instrument... 5 2.6 Environmental instructions... 5 3 Product description 3.1 Configuration... 6 3.2 Principle of operation... 7 3.3 Packaging, transport and storage... 7 4 Mounting 4.1 Safety instructions... 9 4.2 Suitability for the process conditions... 9 4.3 Mounting preparations... 9 4.4 Mount pressure transmitter... 9 4.5 Dismount pressure transmitter... 10 5 Maintenance and fault rectification 5.1 Maintenance... 12 5.2 Rectify faults... 12 5.3 How to proceed if a repair is necessary... 12 6 Dismount 6.1 Dismounting steps... 13 6.2 Disposal... 13 7 Supplement 7.1 Technical data... 14 7.2 Dimensions... 15 2 Editing status: 2015-07-30

1 About this document 1 About this document 1.1 Function This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectification. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device. 1.2 Target group This operating instructions manual is directed to trained specialist personnel. The contents of this manual should be made available to these personnel and put into practice by them. 1.3 Symbols used Information, tip, note This symbol indicates helpful additional information. Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result. Ex applications This symbol indicates special instructions for Ex applications. SIL applications This symbol indicates instructions for functional safety which must be taken into account particularly for safety-relevant applications. List The dot set in front indicates a list with no implied sequence. Action This arrow indicates a single action. 1 Sequence of actions Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of batteries and accumulators. 3

2 For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use The ball valve fitting is used for connection of a pressure transmitter VEGABAR 82 with extension ø 38 mm to a vessel. You can find detailed information about the area of application in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions. For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modifications are explicitly forbidden. 2.3 Warning about incorrect use Inappropriate or incorrect use of the instrument can give rise to application-specific hazards, e.g. vessel overfill or damage to system components through incorrect mounting or adjustment. 4 2.4 General safety instructions This is a state-of-the-art instrument complying with all prevailing regulations and guidelines. The instrument must only be operated in a technically flawless and reliable condition. The operator is responsible for the trouble-free operation of the instrument. During the entire duration of use, the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regulations. The safety instructions in this operating instructions manual, the national installation standards as well as the valid safety regulations and accident prevention rules must be observed by the user. For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modifications are explicitly forbidden. The safety approval markings and safety tips on the device must also be observed.

2.5 Safety label on the instrument 2 For your safety The safety approval markings and safety tips on the device must be observed. 2.6 Environmental instructions Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfill this obligation by observing the environmental instructions in this manual: Chapter "Packaging, transport and storage" Chapter "Disposal" 5

3 Product description 3 Product description Scope of delivery Constituent parts 3.1 Configuration The scope of delivery encompasses: Ball valve fitting Documentation This operating instructions manual The ball valve fitting according to ZB 2553 consists of the following components: Ball valve Locking rods Ventilation valve Flanges 4 3 5 6 2 7 1 8 6 Fig. 1: Ball valve fitting acc. to ZB 2553 with pressure transmitter VEGABAR 82 1 Ball valve 2 Hand lever 3 Flange screws 4 VEGABAR 82 5 Locking rods 6 Flange, sensor side 7 Flange, process side The flange on the process side is available in the following sizes: DN 50 PN 40 DN 80 PN 40 DN 100 PN 40 ASME 2" 150 lbs ASME 3" 150 lbs, 300 lbs ASME 4" 150 lbs, 300 lbs DN 50 10 K JIS

3 Product description DN 80 10 K JIS Area of application 3.2 Principle of operation The ball valve fitting acc. to ZB 2553 is suitable for mounting on vessels with socket and flange. It is suitable for pressure transmitter VE- GABAR 82 with extension tube ø38 mm and enables mounting and dismounting of the pressure transmitter without emptying the vessel. Caution: The max. permissible vessel pressure is 2 bar (200 kpa). Functional principle The ball valve fitting (dimensional drawing) VEGABAR 82 can be set to two positions by means of the hand lever: Operation Service In position "Operation", the ball valve is open to the process. The pressure transmitter is in measuring position. The vent valve is closed. In position "Service", the ball valve is closed to the process. The pressure transmitter is in off position. The vent valve is open. 1 2 Fig. 2: Positions of the ball valve fitting 1 Operation 2 Service Packaging 3.3 Packaging, transport and storage Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test based on ISO 4180. 7

3 Product description The packaging of standard instruments consists of environmentfriendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies. Transport Transport inspection Storage Storage and transport temperature Transport must be carried out in due consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device. The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with. Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside. Unless otherwise indicated, the packages must be stored only under the following conditions: Not in the open Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage and transport temperature see chapter "Supplement - Technical data - Ambient conditions" Relative humidity 20 85 % 8

4 Mounting 4 Mounting 4.1 Safety instructions Always keep in mind the following safety instructions: Mount the ball valve fitting horizontally with lever on the side and ventilation valve pointing downward Dismount the ball valve fitting only in unpressurized status or with emptied vessel Make sure that you are in safe position (not on a ladder) and do not dismount the device at head level. Dismount the pressure transmitter only in position "Service" Suitability for the process conditions 4.2 Suitability for the process conditions Make sure that all parts of the device exposed to the process, in particular the process fitting, valve components and seal, are suitable for the existing process conditions. These include above all the process pressure, process temperature as well as the chemical properties of the medium. You can find the specifications in chapter "Technical data" and on the nameplate. 4.3 Mounting preparations The following tools are required for mounting the pressure transmitter: Wrench (size 13) for the locking rods Wrench (size 17) for the flange screws 4.4 Mount pressure transmitter Danger: Never bring the ball valve into position "Operation" without having the pressure transmitter mounted. Medium can escape and cause damage to property or injury to persons. If the ball valve fitting in Ex applications is opened without the pressure transmitter installed, hazardous gases or vapours can escape. Proceed as follows: 1. Starting point: Ball valve is closed (position: service) 2. Loosen hexagon nuts, O-rings and washers of the locking rods to the sensor flange 3. Open ventilation valve 4. Slide VEGABAR 82 into the opening of the ball valve fitting 5. Slide the locking rods through the holes in the sensor flange and secure with the hexagon nuts, O-rings and washers 6. Close the ventilation valve 7. Open ball valve 9

4 Mounting Danger: When the ball valve is opened, the total vessel pressure acts on VEGABAR 82. 8. Insert the pressure transmitter with a lot of force 9. Immediately tighten the flange screws, torque see chapter "Technical data" Pressure transmitter is hence mounted and can be put into operation. 4.5 Dismount pressure transmitter Danger: The dismounting of the pressure transmitter must never be carried out in position "Operation". Medium can escape under operating pressure and cause damage to property or injury to persons. Proceed as follows: 1. Starting point: Ball valve is open (position: operation) 2. Check if the hexagon nuts, O-rings and washers of the locking rods are tight 3. Loosen the flange screws Danger: The pressure transmitter can come out very quickly. With max. permissible vessel pressure, the forces can be up to 250 N. 10

4 Mounting 4. Close ball valve as soon as the pressure transmitter is pulled out to the maximum (the distance is limited by locking rods) 5. Open ventilation valves slowly, to release the pressure. 6. Loosen hexagon nuts, O-rings and washers of the locking rods to the sensor flange 7. Detach pressure transmitter Dismounting of the pressure transmitter is finished. The reinstallation is carried out as described in chapter "Mouting the pressure transmitter". Danger: Never bring the ball valve into position "Operation" without having the pressure transmitter mounted. Medium can escape and cause damage to property or injury to persons. 11

5 Maintenance and fault rectification 5 Maintenance and fault rectification 5.1 Maintenance If the instrument is used properly, no special maintenance is required in normal operation. Fault rectification 24 hour service hotline Reaction after fault rectification 5.2 Rectify faults The first measures to be taken are to check the output signals as well as to evaluate the error messages via the display and adjustment module. The procedure is described below. Further comprehensive diagnostics can be carried out on a PC with the software PACTware and the suitable DTM. In many cases, the causes can be determined and the faults rectified this way. Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is manned 7 days a week round-the-clock. Since we offer this service worldwide, the support is only available in the English language. The service is free, only standard call charges are incurred. Depending on the reason for the fault and the measures taken, the steps described in chapter "Set up" may have to be carried out again. 5.3 How to proceed if a repair is necessary You can find an instrument return form as well as detailed information of the procedure in the download area on our homepage: www.vega.com. By doing this you help us carry out the repair quickly and without having to call back for needed information. If a repair is necessary, please proceed as follows: Print and fill out one form per instrument Clean the instrument and pack it damage-proof Attach the completed form and, if need be, also a safety data sheet outside on the packaging Please contact the agency serving you to get the address for the return shipment. You can find the agency on our home page www.vega.com. 12

6 Dismount 6 Dismount 6.1 Dismounting steps Warning: Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel or pipeline, high temperatures, corrosive or toxic products etc. Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order. 6.2 Disposal The instrument consists of materials which can be recycled by specialised recycling companies. Mark the instrument as scrap and dispose it according to the national, legal regulations. Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. 13

7 Supplement 7 Supplement 7.1 Technical data Materials and weights Material ƲƲFitting ƲƲ Seal Weight depending on flange size Torques Max. torques ƲƲ Flange screws Process conditions Product temperature Operating pressure max. 316L FKM 8.4 kg (18.52 lbs) 12.5 kg (27.56 lbs) 60 Nm (44.25 lbf ft) -40 +80 C (-40 +176 F) Note product temperature of the pressure transmitter. The lowest possible temperature value is valid. 2 bar 14

7 Supplement 7.2 Dimensions ø 79 mm (3.11") ca. 69 mm (2.72") 159 mm (6.26") 311 mm (12.24") 112 mm (4.41") ø 38 mm (1.50") Fig. 5: Ball valve fitting acc. to ZB 2553 with pressure transmitter VEGABAR 82 15

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2015 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com