Notice. VeraCode Vortex Incubator User Guide

Similar documents
Digital Melting Point Apparatus

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Cocoa Patio Pond with Lit Spillway

Stirring Water Bath. Instruction Manual

with O 2 Controller Instruction Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

In Vivo Scientific, LLC INSTRUCTION MANUAL

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Model No Product Name Handpiece Only Complete System

Heavy-Duty Hot Knife

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

HAS2400 Hepa Air Scrubber

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Agilent 1290 Infinity Pump Head Maintenance

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

ATEX ATEX

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

AIR/OVER HYDRAULIC JACK 20 TON

92831 TEL: (714) FAX:

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

SPS-5. Rate Computing Scale. Operation Manual

Installation and Operation Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Adapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR

Norrsken Family Booklet

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

airplaine kite Model assembly & Operating Instructions Important: If damage is caused due to a crash; your warranty is void.

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

RAM 4021 Operation Manual

1 DRIVE INDUSTRIAL IMPACT WRENCH

deluxe toilet safety support

HI 2314 HI 2315 HI 23151

USER MANUAL

Med Aire Alternating Pressure Pump and Pad System

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

AIR INLINE METAL SHEAR

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

SSS SWEEPERS MODELS MS-21 & MS-29

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Portable Massage Table User Manual

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Owner s Manual & Safety Instructions

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

ROPV R40 E Series User Manual

M5400 Operators Manual

Yoke Block Instruction Manual

ORBITAL AIR SANDER. Owner s Manual

OC Panel High Limit Aquastat Kit, Manual Reset p/n

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

Sample Concentrator SBH CONC/1 Instructions for use

ANALOX O2 PORTABLE OPERATORS MANUAL

BMR 2100XL Operating Instructions Page 1 of 13

6 digital caliper with case

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

! Warning, refer to accompanying documents.

PERSONAL AIR BREATHING UNIT

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Angled Sign Light with Shade

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

PH01 Perfusion Cannula Manual

SPECIFICATIONS APCEPH1

Alternating Pressure / Low Air Loss Mattress System

GE Measurement & Control

Portable oxygen concentrator

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

Vessel Installation and Operating Manual

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

RAM 4021-DPX Operation Manual

TrekMill USER'S MANUAL MM5050

Multi-Probe Sampling System User Guide & Manual

Installation Instructions JATCO Environmental Protection Tank Model J-7000

e.do Gripper Safety requirements, technical features and assembly and integration instructions

SMART Oxygen Analyzer. User Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Lap Count Display Owner s Manual

Installation and Operating Manual

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Transcription:

Notice This publication and its contents are proprietary to Illumina, Inc., and are intended solely for the contractual use of its customers and for no other purpose than to operate the system described herein. This publication and its contents shall not be used or distributed for any other purpose and/or otherwise communicated, disclosed, or reproduced in any way whatsoever without the prior written consent of Illumina, Inc. For the proper operation of this system and/or all parts thereof, the instructions in this guide must be strictly and explicitly followed by experienced personnel. All of the contents of this guide must be fully read and understood prior to operating the system or any of the parts thereof. FAILURE TO COMPLETELY READ AND FULLY UNDERSTAND AND FOLLOW ALL OF THE CONTENTS OF THIS GUIDE PRIOR TO OPERATING THIS SYSTEM, OR PARTS THEREOF, MAY RESULT IN DAMAGE TO THE EQUIPMENT, OR PARTS THEREOF, AND INJURY TO ANY PERSONS OPERATING THE SAME. Illumina, Inc. does not assume any liability arising out of the application or use of any products, component parts or software described herein. Illumina, Inc. further does not convey any license under its patent, trademark, copyright, or common-law rights nor the similar rights of others. Illumina, Inc. further reserves the right to make any changes in any products, or parts thereof, described herein without notice. Illumina, Making Sense Out of Life, Sentrix, GoldenGate, DASL, Oligator, Infinium, BeadArray, Array of Arrays, BeadXpress, VeraCode, IntelliHyb, iselect, CSPro, and Solexa are registered trademarks or trademarks of Illumina, Inc. Other brand and product names mentioned herein may be trademarks or registered trademarks of their respective owners. 2007 Illumina, Inc. All rights reserved. VeraCode Vortex Incubator User Guide

Revision History Revision Date Rev. A May 24 2007 VeraCode Vortex Incubator User Guide

Table of Contents Notice.............................................iii Revision History...................................... v Table of Contents................................... vii List of Figures.......................................ix List of Tables........................................xi Chapter 1 Installing and Using the VeraCode Vortex Incubator.. 1 Introduction......................................... 2 Key Features..................................... 2 Construction..................................... 2 Components..................................... 3 Accessories...................................... 3 Installation.......................................... 7 Unpacking....................................... 7 Selecting a Location............................... 8 Attaching the Power Cord.......................... 9 Starting Up...................................... 9 Front Panel Overview................................ 10 Basic Operation.................................... 11 Setting the Time................................. 11 Setting the RPM................................. 12 Setting the Temperature.......................... 13 Starting the VeraCode Vortex Incubator.............. 14 Changing RPM During a Run....................... 14 Changing the Temperature During a Run............. 15 Completing the Run.............................. 15 Shaking Without Heating.......................... 15 VeraCode Vortex Incubator User Guide

viii Table of Contents Heating Without Shaking.......................... 16 Viewing RPM Value............................... 16 Viewing Time Value............................... 17 Viewing Temperature Value........................ 17 Calibrating Temperature.............................. 18 Procedure for Calibrating Temperature............... 19 Chapter 2 Service Information.......................... 21 Troubleshooting.................................... 22 Errors.......................................... 22 Service and Support................................. 23 Where to Find Help............................... 23 Warranty....................................... 23 Technical Specifications............................... 25 Maintenance and Cleaning Instructions.................. 26 Part # 11251876 Rev. A

List of Figures Figure 1 Microtube Platform................................... 4 Figure 2 Installing the Microplate Platform........................ 6 Figure 3 Aligning the Microplate Platform........................ 6 Figure 4 Attaching the Microplate Platform....................... 7 VeraCode Vortex Incubator User Guide

x List of Figures Part # 11251876 Rev. A

List of Tables Table 1 VeraCode Vortex Incubator LEDs....................... 10 Table 2 VeraCode Vortex Incubator Buttons..................... 10 Table 1 Error Descriptions................................... 22 Table 2 Technical Data..................................... 25 VeraCode Vortex Incubator User Guide

xii List of Tables Part # 11251876 Rev. A

Chapter 1 Installing and Using the VeraCode Vortex Incubator Topics 2 Introduction 7 Installation 10 Front Panel Overview 11 Basic Operation 18 Calibrating Temperature VeraCode Vortex Incubator User Guide

2 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Introduction Key Features Construction The VeraCode Vortex Incubator is a benchtop shaker and heating chamber for incubating and shaking sensitive samples. It replaces two devices, reducing both the time and the space needed. It is suitable for biochemistry, microbiology, and clinical laboratories in which applications require temperature and shaking treatment. The VeraCode Vortex Incubator has several features, including: Digital display of running parameters allows viewing and setting RPM, temperature, and/or time when the device is running or when it is in standby mode Last used settings are saved in memory after the unit is powered off The precise temperature control system provides for temperature uniformity of +/-0.5 C Over-temperature protection system ensures sample safety Simple user interface; the encoder knob enables rapid adjustment of settings Interchangeable platforms for test tubes and stainless steel microplate platforms High capacity of 56 microtubes or four microplates (or two deep well microplates) The housing of the VeraCode Vortex Incubator is constructed of steel plate, coated with highly resistant polyurethane lacquer. The interior chamber is isolated with special thermal protection materials and insulation foam. Both the shaking mechanism and the temperature chamber are regulated via microprocessors, which control all sensors for motor speed, temperature, and time. Part # 11251876 Rev. A

Introduction 3 Components Accessories The VeraCode Vortex Incubator consists of seven main components: Drive motor Eccentricity control mechanism Chamber fan Heating element Temperature sensor Temperature controlled chamber Control electronics The drive motor controls the eccentricity control mechanism, which generates the orbital motion of the sample platform. The motion of the motor also drives the fan, which moves air over the heating element and throughout the temperature chamber. The convection action of the airflow creates a uniform temperature environment throughout the chamber. Chamber conditions are monitored by the temperature sensor, and the control electronics regulate heater function to maintain the set temperature. The following accessories are available for the VeraCode Vortex Incubator: 1.5/2.0 ml Platform S2056-R Adapter for 0.5 ml C1205 Adapter for 0.4 ml C1206 Adapter for 0.25 ml C1222 Microplate Platform S2056-Q VeraCode Vortex Incubator User Guide

4 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Microtube Platform The Microtube Platform is intended for shaking 56 1.5/2 ml test tubes. There are adapters available that enable running several different microtube sizes. In addition, the platform and adapters are autoclavable. Screw Shaking plate (in shield chamber) Figure 1 Microtube Platform Installing the Microtube Platform is a simple process, requiring no special tools. The unit comes pre-assembled with four posts screwed into the shield plate. 1. Grip the microtube platform by the center knob. 2. Align the four rubber grommets with the four posts of the platform. 3. Press down gently. Part # 11251876 Rev. A

Introduction 5 For processing large sample quantities it is often more convenient to use more than one microtube platform and switch between them. NOTE If you work with temperatures over 50 C, we recommend using special microtubes that are designed for use in thermal cyclers. These tubes are molded from plastic designed to withstand temperatures as high as 135 C. The thin-walled construction also allows for fast heat transfer and reduced heating times. Microplate Holder Platform WARNING Be careful if the unit has been used to heat samples because the internal components can be extremely hot and can cause burns to uncovered skin. Always check the handle temperature before changing the platform. The Microplate Holder Platform is designed for shaking up to four microplates or two deep-well microplates. For a more precise temperature controlled environment, we recommend inserting only one microplate on the platform. Additional microplates can have an insulating effect on other plates, especially when stacked. The working temperature range is +5 C to 45 C. Note that the normal maximum temperature for ordinary microplates is below 60 C. The platform is made of stainless steel and is equipped with springs for keeping microplates secure. The VeraCode Vortex Incubator comes with the Microtube Platform installed. To install the Microplate Platform: VeraCode Vortex Incubator User Guide

6 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator 1. Remove the Microtube Platform. 2. Unscrew all four posts from the outside of the lower platform (see Figure 2). Figure 2 Installing the Microplate Platform 3. Attach the Microplate Platform by centering the platform corner holes on the device shield plate (see Figure 3). Ensure the alignment arrows are pointing towards the front of the unit. Figure 3 Aligning the Microplate Platform Part # 11251876 Rev. A

Installation 7 4. Press the platform onto the shield plate. 5. Using the supplied nuts and washers, attach the Microplate Platform to the shiled plate. Tighten the nuts and washers with the included wrench. Screw Unscrew Figure 4 Attaching the Microplate Platform 6. Insert the microplates with your samples, and start the device. Installation Unpacking There are several steps to installing the VeraCode Vortex Incubator. Carefully examine the unit for possible shipping damage or missing parts prior to installation: 1. Open the box and remove the unit and all of the accessories. 2. Remove the packing material and inspect the machine to be sure that it has not been visibly damaged during shipping. Keep all packing material until you are sure that the machine functions properly. VeraCode Vortex Incubator User Guide

8 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator 3. Check the rear label for the following information: a. Model Number b. Serial Number c. Electrical rating d. Regulatory markings 4. Check the plug to be sure that it is compatible with your electrical outlet. If any damage occurred during shipping, notify the carrier immediately. If any parts or accessories are missing, report them to your distributor immediately. Selecting a Location When selecting the location for your device, consider the following: 1. The unit needs to be placed on a smooth, level, and stable surface. 2. Leave at least 10 cm of space around the device for adequate air circulation. 3. Do not place the device in a location where there are rapid temperature and humidity changes. Also, avoid places where the unit would be exposed to direct sunlight or next to devices which output large amounts of heat. 4. Avoid places where the unit may be exposed to excessive shocks or vibrations. WARNING Do not use the device in a flammable or explosive atmosphere. NOTE The unit should not be placed so that it is difficult to pull out the plug from the back of the unit. Environmental Requirements The VeraCode Vortex Incubator has a wide temperature range at which it is operational; +5 C 99.5 C. It is also safe for use in room that have up to 85% relative humidity. Part # 11251876 Rev. A

Installation 9 Attaching the Power Cord Attach the main power cord to the inlet on the back of the unit. Connect the other end of the cord to a grounded electrical outlet. Starting Up 1. After installing the device, open the lid and attach the Microtube Platform or the Microplate Platform. 2. Close the lid. 3. Switch on the device using the Power switch on the front panel. The switch illuminates to indicate that power is on. 4. Check the running parameters and set new parameters, if necessary. Refer to Basic Operation on page 11. Safety Recommendations CAUTION Use care when changing the microtube platform, especially if you have used the unit at temperatures higher than 60 C. Always wear protective clothing before you handle a hot microtube or microplate platform. The unit will continue to shake for 5 seconds after the lid is opened. Be careful when opening the lid as the parts inside may still be in motion. In addition, never touch the fan unless the unit is turned off or unplugged. Before cleaning the housing, unplug the unit. Clean the housing with a damp cloth and, if necessary, mild soap. Do not use abrasive or aerosol cleaners. Do not use the unit near sources of water. Ensure that water does not spill in the device; be especially careful during cleaning procedures. Ensure that all test tubes are closed tightly before placing them into the unit to avoid spilling samples inside the chamber. In case of a malfunction, unplug the device and contact your distributor for service. WARNING Do not shake flammable or explosive samples. VeraCode Vortex Incubator User Guide

10 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Front Panel Overview Figure 5 Table 1 LED VeraCode Vortex Incubator Front Panel VeraCode Vortex Incubator LEDs Description Run (green) Time (yellow) RPM (yellow) Temperature (yellow) Illuminated when the unit is operating Illuminated when the unit is set to adjust time Illuminated when the unit is set to adjust PRM Illuminated when the unit is set to adjust temperature Table 2 Button POWER VeraCode Vortex Incubator Buttons Description Switch on or off (illuminates when on) ENCODER Start/Stop By rotating the encoder right (+) or left (-) you can modify the time, temperature, or RPM settings of the unit. Pushing in on the ENCODER changes between time, temperature, and RPM set values. Rotating the ENCODER knob quickly increases the value increments, enabling values to be set more quickly. Start or stop shaking Part # 11251876 Rev. A

Basic Operation 11 Basic Operation Press the POWER button on the front panel. The LED displays the line frequency F50 (50Hz) or F60 (60Hz). After a 2 second delay the unit defaults to the time setting. Figure 6 Powering On the VeraCode Vortex Incubator Setting the Time When the time LED is illuminated, rotate the ENCODER knob right (+) or left (-) to set the desired time value, from 30 seconds to 99 minutes, 50 seconds: 99.5 99 minutes 50 seconds 9.59 9 minutes 59 seconds Figure 7 Time LED VeraCode Vortex Incubator User Guide

12 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator To have the unit run continuously, set Time to hold by rotating the ENCODER knob to under 0.30 or over 99.5. The timer is set to hold when HLd appears. Figure 8 Running Continuously Setting the RPM When the RPM LED is illuminated, rotate the ENCODER knob right (+) or left (-) to set the rotating speed to the desired value: 34 340 RPM 120 1200 RPM Turning the RPM setting below 20 turns the shaking function off. When the shaker is off, OFF appears. Run Time (Minutes) RPM (nx10) 120 POWER Temperature( 0C) ENCODER Start Stop Figure 9 Setting the Rotating Speed Part # 11251876 Rev. A

Basic Operation 13 Setting the Temperature Push the ENCODER knob to adjust the Temperature setting. When the Temperature LED is illuminated, rotate the ENCODER knob right (+) or left (-) to set the temperature to the desired value: 37.5 37.5 C Figure 10 Adjusting Temperature To use the shaker without using the temperature control, turn the ENCODER knob under 0.5 or above 99.5 until the display reads OFF. Figure 11 Shaking without Temperature Control VeraCode Vortex Incubator User Guide

14 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Starting the VeraCode Vortex Incubator 1. Press the Start/Stop button. Run and Time are illuminated. The timer counts down from the set time value. You cannot adjust the set time during shaking. NOTE Figure 12 Timer Countdown Changing RPM During a Run 1. Push the ENCODER knob until the RPM LED is illuminated. 2. Rotate the ENCODER knob right (+) or left (-) until the new value is set. While adjusting the RPM, the LED will pulse. When you stop rotating the ENCODER knob, the RPM LED will stop pulsing after 2 seconds. Figure 13 Changing the RPM During a Run Part # 11251876 Rev. A

Basic Operation 15 Changing the Temperature During a Run 1. Push the ENCODER knob until the Temperature LED is illuminated. 2. Rotate the ENCODER knob right (+) or left (-) until the desired temperature is set. While adjusting the temperature, the temperature LED pulses. When you stop rotating the ENCODER knob, the temperature LED stops pulsing after 2 seconds. Figure 14 Changing the Temperature During a Run Completing the Run When the set time expires, or if you press the Start/Stop button, End appears on the display and the Run LED pulses. When the unit stops shaking, the last set values for Time, RPM, and Temperature are saved in memory. Figure 15 Run Complete Shaking Without Heating To shake samples without heating, set Temperature to OFF. VeraCode Vortex Incubator User Guide

16 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Heating Without Shaking To heat samples without shaking, set RPM to OFF. NOTE The shaker motor drives the fan, which circulates warm air throughout the chamber aiding in temperature uniformity. If the unit is set to OFF, the temperature control will not be as precise due to lack of airflow over the heating element. Viewing RPM Value 1. Turn the ENCODER one click right (+) or left (-). Note that the unit must be set for RPM mode. The RPM LED pulses for 2 seconds and the display shows the set RPM. After 2 seconds the display returns to showing the actual RPM and the LED stops pulsing. Figure 16 Viewing RPM Values During Shaking Part # 11251876 Rev. A

Basic Operation 17 Viewing Time Value 1. Turn the ENCODER knob one click right (+) or left (-). Note that the unit must be set for Time mode. The Time LED pulses for 2 seconds and the display shows the set time. After 2 seconds the display returns to showing the actual time and the LED stops pulsing. Run Time (Minutes) RPM (nx10) 99.5 POWER Temperature( 0C) ENCODER Start Stop Figure 17 Viewing Time Settings During Shaking Viewing Temperature Value To view the set value for temperature during shaking: 1. Turn the ENCODER knob one click right (+) or left (-). Note that the unit must be set for Temperature mode (see Setting the Temperature on page 13). On the display the Temperature LED pulses for 2 seconds and the display shows the set temperature. After 2 seconds the display returns to showing the actual temperature and the LED stops pulsing. Figure 18 Viewing Temperature Settings During Shaking VeraCode Vortex Incubator User Guide

18 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Calibrating Temperature The temperature control software allows you to calibrate the temperature settings. 1. Measure the temperature in the middle of the chamber after allowing the temperature to equilibrate for two hours. The temperature should be measured with a digital calibrated thermometer with precision 0.1 C or more. 2. After allowing the temperature to equilibrate 2 hours, read the temperature on the thermometer and compare it with the temperature on the LED display. The difference between the thermometer and the display is the value which you will enter into the unit to recalibrate it. Example 1 The temperature on the thermometer is 37.9 C, while the temperature on the display is 37 C. The difference between the two is 37.9 37 = 0.9. This value (0.9) is the value you enter into the software. Example 2 The temperature on the thermometer is 36.2 C, while the temperature on the display is 37 C. The difference between the two is 37 36.2 = 0.8. This value (0.8) is the value you enter into the software. Part # 11251876 Rev. A

Calibrating Temperature 19 Procedure for Calibrating Temperature NOTE Remember, temperature calibration should only be performed by qualified personnel. 1. Hold the ENCODER knob for 5 seconds. The display shows Cor (correction). 2. Press the ENCODER knob once, then enter the value from the previous section by rotating the ENCODER left or right to select a value (see Example 1 and Example 2 in Calibrating Temperature on page 18). Be sure to note whether your value was positive or negative. 3. After you have entered the value, press the ENCODER knob again. 4. Press Start/Stop to complete the temperature calibration. VeraCode Vortex Incubator User Guide

20 CHAPTER 1 Installing and Using the VeraCode Vortex Incubator Part # 11251876 Rev. A

Chapter 2 Service Information Topics 22 Troubleshooting 23 Service and Support 25 Technical Specifications 26 Maintenance and Cleaning Instructions VeraCode Vortex Incubator User Guide

22 CHAPTER 2 Service Information Troubleshooting Errors The VeraCode Vortex Incubator features built in self-diagnostic procedures that are constantly checking the operating parameters and performance. If an error occurs, the error code appears on the front panel. Error Descriptions Table 1 Error E 1.1 E 1.2 E 1.3 E 2.1 E 2.2 Er 5 Error Descriptions Description Something is wrong with motor regulation (PWM regulator, pulse generator, motor). The unit will automatically stop. Call for service. The motor did not reach the set RPM in 30 seconds. The unit will automatically stop. Call for service. The unit has oscillated more then 100 RPM in 2 seconds. The unit will automatically stop. Call for service. The temperature sensor is not working properly. The unit will automatically stop. Call for service. The temperature sensor registers a 5 C higher temperature than the set temperature. The unit will automatically stop. Call for service. The lid of the shaker has been open for more than 5 seconds. The unit will automatically stop. To restart the shaker, close the lid and press the Start/Stop button. Part # 11251876 Rev. A

Service and Support 23 Service and Support Where to Find Help Warranty Labnet International provides warranty and after-warranty support for all products. Depending upon how you purchased your equipment, the best source of support is either Labnet, your dealer, or your own organization. Labnet s warranty statement is included in this chapter and on the warranty card included with your unit. Please read over this information carefully and retain it for your records. One-Year Limited Warranty Labnet International warrants this product against defects in materials and workmanship for a period of one year from receipt by the end user. During the warranty period, Labnet will, at its option, either repair or replace products that prove to be defective. Should manufacturer be unable to repair or replace the product within a reasonable amount of time, a refund of the purchase may be given upon return of the product. Exclusions The warranty on manufacturer products shall not apply to defects or damage resulting from: Improper or inadequate maintenance by customer Unauthorized modification or misuse Operation outside of the environmental specifications for the product Improper site preparation and maintenance Warranty Limitations The warranty set forth above is exclusive and no other warranty, whether written or oral, is expressed or implied. Labnet specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. VeraCode Vortex Incubator User Guide

24 CHAPTER 2 Service Information Service During Warranty Period If your hardware should fail during the warranty period, contact an authorized manufacturer dealer or distributor in your country or contact Labnet directly at 732-417-0700 during the hours of 8:30 AM and 5 PM EST. When shipping your equipment to Labnet for service, follow the packing guidelines listed below. Shipping damage as result of inadequate packaging is the customer s responsibility. Use original packing materials whenever possible. Repackaging Guidelines for Returning Your Equipment Clean the inside of the chamber and platforms according to Good Laboratory Practices standards, especially if you have used the equipment with hazardous biological or radioactive materials. Send a written description of the error with the unit. Use the original shipping container and packaging materials, if possible. Part # 11251876 Rev. A

Technical Specifications 25 Technical Specifications Table 2 Technical Data Item Specifications Power Heater power Motor power Fuse Ambient temperature Relative humidity 515W 500W 15W 2 x 3 15A 250V 4 C 65 C Up to 85%, non-condensing RPM regulation Digital, load independent, from 100 to 1200 RPM in 10 RPM steps 1400 RPM only at 60 Hz Shaker orbit Temperature operating range Temperature sensor Heating-up time Temperature uniformity Timer Maximum capacity Dimensions (w x d x h) Weight 3 mm 4 C above room temperature to 99.5 C PT100 Approximately 5 C/minute ± 0.5 C 30 seconds 99 minutes 50 seconds in 10 second steps under 10 minutes in 1 second steps timer HOLD function 56 test tubes; 1.5, 0.7, 0.5, 0.25 ml 265 mm x 325 mm x 225 mm 11 kg VeraCode Vortex Incubator User Guide

26 CHAPTER 2 Service Information WARNING There are no end-user serviceable parts. Any service to the unit must be performed by a trained service technician. Maintenance and Cleaning Instructions The chamber should be cleaned regularly. Any samples which spill inside or outside the chamber must be wiped up immediately. Use only warm water or a mild soap solution to clean the surfaces of the unit. Using aggressive or abrasive cleaners can cause permanent damage to the finish. To decontaminate the surface of the unit, use only neutral solutions (Ph 7 8). The stainless steel platform and nuts can be decontaminated in an autoclave (120 C). CAUTION Take care when cleaning the device after operation, especially if you have used the device at temperatures higher than 60 C. Exposed surfaces will be extremely hot and may cause burns to unprotected skin. Always unplug the unit before cleaning it. Before using any cleaning or decontamination methods other than those recommended by the manufacturer, contact Labnet to ensure that the proposed method will not damage the equipment. Part # 11251876 Rev. A