HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Similar documents
HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Minimum size for maximum performance

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

HAMILTON-T1 Intelligent transport ventilation for armed forces

ASV. Adaptive Support Ventilation

Supporting you in saving lives!

HAMILTON-C3. The compact high-end ventilator

Intelligent Ventilation solution from ICU to MRI

HAMILTON-G5. The modular high-end ventilation solution

Safe ventilation at rest and on the move

INTELLiVENT -ASV. The world s first Ventilation Autopilot

HAMILTON-C6. The next generation of intelligent ICU ventilators

With INTELLiVENT -ASV, the world s first fully closed loop ventilation. The next era of Intelligent Ventilation

Safe ventilation at rest and on the move

More safety for your patient

fabian Therapy evolution Our 2-in-1 device

Safe and Intuitive Neonatal Ventilation

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Flight Medical presents the F60

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

IEC C LASSIFICATIONS:

Milestones of Aeonmed Ventilators

D Beyond essentials DRÄGER SAVINA 300 SELECT


Monnal T60. Touch and Breathe.

HAMILTON-C1 neo. Technical specifications

fabian HFO Our 4-in-1 device

fabian HFO: Modular, Powerful, Versatile.

Introducing Astral. Greater freedom. Confident care. Designed efficiency

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

HAMILTON-MR1. Technical specifications HAMILTON-MR1

D Beyond essentials DRÄGER SAVINA 300 SELECT

How Ventilators Work. Chapter 3

Focused on essentials DRÄGER SAVINA 300

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

Mechanical Ventilation

Inspiration 7i Ventilator

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

evolution 3e Ventilators

Blease900 Ventilator PATIENT CENTERED VENTILATION

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Giving neonates a future

Oxylog 3000 plus Emergency & Transport Ventilation

Focused on essentials DRÄGER SAVINA 300

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Emergency Transport and Ventilation

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Entry to the premium class!

Supporting your patients every breath

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

fabian HFOi Our 4-in-1 device

Technical Data and Specifications

A9600 Anesthesia Workstation. Your healthcare, we care.

Dräger Savina Sub-Acute Care Ventilation

INTENSIVE CARE VENTILATORS

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

GE Healthcare. Aestiva/5. More than superior ventilation

Hospital and Transport for Controlled Breathing

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

WILAmed INTENSA. Intensive Care Ventilator System

Selecting the Ventilator and the Mode. Chapter 6

Panther 5 Acute Care Ventilator

D Designed for non-invasive ventilation DRÄGER CARINA

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

Intensa GO Alternate Care Ventilator

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

MT Excellent performance and reliability EVITA 4 EDITION

Airox Supportair Ventilator

SLE5000 Infant Ventilator with HFO

Organis TestChest. Flight Simulator for Intensive Care Clinicians

Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

Made to meet your needs DRÄGER SAVINA 300

V8800 Ventilator System. Your healthcare, we care.

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Puritan Bennett 840 Universal Ventilator

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Anesthesia Workstation

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

D Rising up to the challenge OXYLOG 3000 PLUS

Technical specifications for SW version 2.0.x. Mode form Mode name Mode Adult/Ped Neonatal

DATA SHEET. VENTILATION SERVO-s

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

ekom Compressor for Medical Air Sonata with Ekom

Operation and Maintenance of the EPV200 Portable Ventilator

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Stephanie. Pediatrics. The ventilation system for neonatology

NEONATAL/INFANT VENTILATOR

MT The secret of harmonious breathing BABYLOG 8000 PLUS

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

ReVel ventilator po r table critica l ca re ven t i l a t i on

HAMILTON-T1. Technical specifications HAMILTON-T1

HAMILTON-C1. Technical specifications

Transcription:

HAMILTON-T1 HAMILTON-T1 Intelligent transport ventilation Intelligent Ventilation since 1983

Intelligent transport ventilation HAMILTON-T1 - A fully featured intensive care ventilator for transport The HAMILTON-T1 combines for the first time the functionality of a fully featured intensive care unit ventilator with the compactness and ruggedness required for transport. This is why the HAMILTON-T1 enables you to provide optimal ventilation therapy to all patient groups during transport, from the neonate to the adult. The HAMILTON-T1 provides: Approvals and certificates for use in ambulances, helicopters and airplanes Independence from gas cylinders or compressors More than 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy* Adult, pediatric, and neonatal ventilation Advanced ventilation modes, including ASV - Adaptive Support Ventilation We use the HAMILTON-T1 for intrahospital transport and transfers to other hospitals. This ensures that the patient receives the same quality of ventilation during transport as at the bedside. Ralf Huth, Senior Physician Interdisciplinary Pediatric ICU Center for Pediatrics and Adolescent Medicine, Mainz, Germany *Optional, not available in all markets Hamilton Medical HAMILTON-T1 3

Unlimited mobility Approved for all types of transport The HAMILTON-T1 meets the transport standards EN 794-3 and ISO 10651-3 for emergency and transport ventilators, EN 1789 for ambulances and EN 13718-1 as well as RTCA/DO-160G for aircrafts. It reliably accompanies your patients within or outside of the hospital, on the ground, at sea and in the air. Independent from compressed air The integrated high-performance turbine enables the HAMILTON-T1 to be completely independent from compressed air. This reduces weight and saves space, since you need neither gas cylinders nor a compressor. This allows even noninvasively ventilated patients to be transported successfully across greater distances. Lightweight, compact and sturdy The compact design and light weight of the HAMILTON-T1 facilitate ventilator handling. The water-resistant housing offers impact protection and a shock-resistant, anti-reflective display. This makes the HAMILTON-T1 a rugged and reliable companion. Approved for use in helicopters Intrahospital transport 4

Optimal performance The right ventilation mode for your patients In addition to conventional and modern modes of invasive and noninvasive ventilation, the HAMILTON-T1 also offers the option of an integrated high flow oxygen therapy mode. Using the same device and breathing circuit, you can change the interface in just a few quick steps and adjust the therapy to best meet your patients needs. This guarantees that during transport, your patients receive the same high level of ventilation care as at the bedside. In pressure controlled modes, an optional feature enables use of conventional speaking valves with the HAMILTON-T1. Adaptive synchronization The IntelliTrig function automatically adjusts the inspiratory and expiratory trigger sensitivity to potential leaks and ensures adaptive synchronization with the patient s breathing pattern. This is achieved both for invasively and noninvasively ventilated patients. Oxygen adjustable from 21% to 100% The finely adjustable oxygen concentration enables you to resume the bedside settings one-to-one during transport. The adjustment to 21% even offers you the option of ventilating your patient with ambient air only. Invasive ventilation during transport High flow oxygen therapy Hamilton Medical HAMILTON-T1 5

Product overview 1 Handle available in different styles 2 Patient interfaces and ports 3 Press-and-turn knob 4 Ventilation Cockpit 5 360 visible alarm lamp 6 Worldwide compatible power supply (AC/DC) 7 8 Installation and mounting options (selection) Hot-swappable battery 7 9 Transport rack with oxygen cylinder (optional)

1 5 4 2 6 3 8 9

ASV has been very successfully used in clinical practice. Our crews who use ASV on a daily basis are very excited and report that the ventilator can almost be completely relied upon to do the job and the patient can be set up without rushing. Dr. Olivier Seiler, Deputy Medical Director until 2014 Rega Air Ambulance, Zurich, Switzerland

More safety and comfort for your patients Enhanced patient comfort Every Hamilton Medical ventilator features the intelligent ventilation mode ASV (Adaptive Support Ventilation). ASV measures the patient s lung mechanics and activity on a breath-by-breath basis and automatically adjusts ventilation, from intubation to extubation. Since its introduction in 1997, ASV has become well established in 1), 2) intensive care units and has been shown to improve patient/ventilator interaction. 1 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9. 2 Sulzer CF. Anesthesiology. 2001 Dec;95(6):1339-45. 3 Sulemanji D. Anesthesiology. 2009 Oct;111(4):863-70. 4 Kirakli C. Eur Respir J. 2011 Oct;38(4):774-80 5 Chen CW. Respir Care. 2011 Jul;56(7):976-83. Lung-protective ventilation ASV ensures via an optimal breathing pattern that the patient receives the set minute volume, irrespective of the patient s activity. As part of this process, ASV employs lung-protective strategies to minimize complications from AutoPEEP and volutrauma/barotrauma. ASV also prevents apnea, tachypnea, excessive dead-space ventilation, and excessively large breaths. 3) Decreased ventilation time Clinical studies show that: 4), 5) ASV supports the earliest possible spontaneous breathing by the patient 4), 5) ASV shortens the ventilation time in various patient groups Hamilton Medical HAMILTON-T1 9

Ease of use Intuitive operation In close cooperation with users and ventilation experts, our engineers have designed the HAMILTON-T1 user interface to allow intuitive operation and direct access to important settings. All Hamilton Medical ventilators are operated according to the same principles, which makes switching between different devices very easy. Easy-to-understand monitoring Ventilators display large amounts of data that is often difficult to interpret. The configurable touch screen display, referred to as the Ventilation Cockpit, consolidates the diverse monitoring data, and presents it numerically and in various graphics panels. These easy-to-understand views provide an at-a-glance overview of the patient s current ventilation status, and offer a reliable basis for therapy decisions. More time for your patients In ASV mode, the ventilator continuously adjusts to the patient s breathing activity and lung conditions. This means fewer user interactions are required and fewer alarms are generated 1), giving you more time for your patients. Monitoring window More time for your patient 1 Beijers AJ. Intensive Care Med. 2014 May:40(5):752-3. 2 Zhu F. Anesthesiology. 2015 Apr;122(4):832-40. 10

4 2 3 1 The Ventilation Cockpit 1 Dynamic lung - Provides a real-time display of lung compliance, resistance, breathing activity, SpO2 and pulse rate 5a 2 Direct access to the most important settings 3 The four most important monitoring parameters 4 5 Configurable waveforms for flow, pressure, SpO2 and CO2 Display options of the Ventilation Cockpit: a) ASV Graph b) Vent Status c) Trends (not shown) d) Loops (not shown) 5b Hamilton Medical HAMILTON-T1 11

- Patients in the medical intensive care unit could be extubated earlier following the introduction of ASV. 5)

Increased efficiency Integrated commercial considerations Ventilators are capital goods that need to be evaluated for cost efficiency. Factors including treatment costs and the use of human resources play an important role in this process. Assembled with an extensive standard equipment package that is easy to maintain, Hamilton Medical ventilators are an attractive investment with respect to purchase price and operating costs. Reduction of treatment costs For each day where ventilation is no longer required, treatment costs are reduced by 1,500 USD on average. 1) It has been shown that the use of Hamilton Medical ventilators and ASV can reduce ventilation time. In addition, the ventilator is then available for the next patient much earlier. A shorter ventilation time also reduces the risk of ventilator-associated pneumonia (VAP), which can result in costs of up to 57,000 USD per case. 2) Better use of human resources 1 Dasta JF et al. Critical Care Med. 2005 Jun;33:1266-71 2 Cocanour CS et al. Surg Infect. 2005 Spring;6:65-72 3 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9 4 Petter AH. Anesth Analg. 2003 Dec;97(6):1743-50 Hamilton Medical ventilators, along with ASV, can reduce the time needed for standard settings and alarm management while maintaining ventilation quality. 3), 4) This frees up time for other aspects of patient care. Thanks to the ease of operation, consistent operating concepts across devices, and the free e-learning offerings from Hamilton Medical, the effort for education and training is also reduced. Hamilton Medical HAMILTON-T1 13

Attention to details Customizable user interface You can configure the display layout with different waveforms, loops, trends, or intelligent panel graphics to suit your institution s needs and protocols. Nurses and clinicians can have their own preferred layout. Access the Monitoring window with the touch of a button at any time during active ventilation. Quick startup Individual modes and numerous settings can be stored in up to three quick startup settings. This may help you save valuable time when you have a limited window to start ventilation. More than 9 hours of battery operating time A battery operating time of more than 9 hours is provided by one integrated and one hot-swappable battery. The battery operating time can be extended as required with additional hot-swappable batteries. Use with night vision goggles Thanks to the night vision option the HAMILTON-T1 can be used with night vision devices without significantly affecting the pilot s visibility. Volumetric capnography Proximal flow and CO2 measurement enables the HAMILTON-T1 to perform up-to-date volumetric capnography. This provides an important basis for the assessment of ventilation quality and metabolic activity. The volumetric capnography is optionally available. 14

Neonatal ventilation Tidal volumes as low as 2 ml With the neonatal option, the HAMILTON-T1 provides tidal volumes as low as 2 ml for effective, safe, and lung-protective ventilation even for the smallest patients. 1) The proximal flow sensor specifically developed for neonates precisely measures the pressure, volume, and flow directly at the infant s airway opening, ensuring the required trigger sensitivity. This provides improved synchronization and less work of breathing. Adaptive synchronization, even with uncuffed tubes Leaks are one of the issues encountered in the ventilation of neonates as a result of using uncuffed tubes. The IntelliTrig leak compensation function automatically adjusts the inspiratory and expiratory trigger sensitivity to leaks. This enables adaptive synchronization with the neonate s breathing pattern ncpap - Automatic adaptation, fewer interventions The HAMILTON-T1 s ncpap mode is designed in such a way that you only need to set the desired CPAP pressure. The flow is subsequently adjusted automatically based on the patient condition and potential leaks. This prevents unintended peak pressures and guarantees highly efficient leak compensation. Flow adjustment occurs very rapidly due to near-patient pressure measurement and the high sensitivity of the measurement. 1 Volume-targeted versus pressure-limited ventilation in the neonate (Review), 2011 Morley CJ Neonatal transportation Effective, safe, and lung-protective ventilation for the most fragile patients Hamilton Medical HAMILTON-T1 15

Hamilton Medical Intelligent Ventilation since 1983 In 1983 Hamilton Medical was founded with a vision: To develop intelligent ventilation solutions that make life easier for patients in critical care and for the people who care for them. Today, Hamilton Medical is a leading manufacturer of critical care ventilation solutions for a wide variety of patient populations, applications, and environments. The right ventilation solution for every situation The ventilators from Hamilton Medical ventilate all of your patients; in the intensive care unit, during an MRI procedure and in all transport situations, from the neonate to the adult. Each of these ventilators is equipped with the same standardized user interface and uses the same Intelligent Ventilation technologies. This enables Hamilton Medical ventilators to help you to: Increase the comfort and safety of your patients Make life easier for the caregivers Increase efficiency and return on investment 689331.04 Product and order infromation are subject to change without notice. ASV and INTELLiVENT are trademarks of Hamilton Medical. Not all options are available in all countries. 2016 Hamilton Medical AG. All rights reserved. Hamilton Medical AG Via Crusch 8 7402 Bonaduz, Switzerland +41 58 610 10 20 info@hamilton-medical.com www.hamilton-medical.com