TECHNICAL DATA NOTICE

Similar documents
TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

OBSOLETE. Wet pipe low flow manifold system

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA. Trimpac 244a. September 16, 2013

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA OBSOLETE

TECHNICAL DATA CAUTION

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

Anti-flood device Model B-1

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Wet pipe low flow foam/water system

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Speed control assembly model A-1

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

OBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3", 4", 6" and 8" (50, 80, 100, 150, and 200 mm)

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

AIR FOAM CHAMBER DATA SHEET

TECHNICAL DATA ACCELERATOR MODEL E-1

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

Air Eliminators and Combination Air Eliminators Strainers

FOAM TANK (1/2) DATA SHEET

DESIGN DATA. Dry 105a. September 5, 2008

Rate of Flow Valve Series 120

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Foam Chamber Model-FC

TECHNICAL DATA OBSOLETE

FOAM TANK (1/2) DATA SHEET

VERTICAL BLADDER TANK

SINGLE VALVE WITH LOW-FLOW BYPASS

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

HORIZONTAL BLADDER TANK

BACK PRESSURE / SUSTAINING

CASH VALVE TYPE KP BACK PRESSURE VALVES

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

BACK PRESSURE / SUSTAINING

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Bermad Pressure Reducing. Model: 42T

Vertical Bladder Tanks

T208VR Series Tank Blanketing Vacuum Regulator

Bladder Tank Installation & System Design Information

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Model MTB-ASME Vertical Bladder Tanks

HYDROVEX TTT Membrane Flow Regulator

InnovDos Foam proportioning system

Model MTB-ASME Vertical Bladder Tanks

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

BALANCED PRESSURE PROPORTIONERS

OPERATION AND MAINTENANCE MANUAL

TECHNICAL DATA OBSOLETE

InnoVfoam B.V. InnovDos Foam Proportioning System

TECHNICAL DATA CAUTION

Residential Pressure Booster Systems

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MRO Oil-Air Ratio Regulator

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Industrial Fire Brigades Marine/Offshore Forest/Bush Fires Sprinkler

FILTER BYPASS CONTROL

Model: 43T. Bermad Pressure Relief Valve

Foam Mixers & Proportioning Systems

Model 420-HY Pressure Regulating Hydrant Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Transcription:

Page 1 of 5 1. DESCRIPTION FomTec BFZ Inductors are used to mix foam concentrate with water when the foam concentrate is supplied from a tank at atmospheric pressure. The BFZ inductor can be installed in deluge systems where sprinklers are used, such as storage facilities and aircraft hangars. The inductors are connected to the water line. Features: Fixed between-flange installation High back pressure High suction height Can be customized to handle various flow rates Compatible with alcohol resistant foam concentrates 2. LISTINGS AND APPROVALS No listings or approvals. 3. MANUFACTURER Dafo Fomtec AB, Sweden 4. Specifications: See Tables 1 and 2 Working Range: See Figures 3-6. Proportioning Rate: 1%, 3%, or 6% Standard Suction Height: 9.84 feet (3 m) NOTE: Induction performance and suction height can be adjusted up to a physical limit of approximately 26 feet (8 m). Minimum Inlet Pressure: 58 PSI (4 BAR) Maximum Inlet Pressure: 232 PSI (16 BAR) Pressure Drop: 35% Material Standards: Body - Bronze Ordering Information: When ordering Inductor: Required GPM and PSI at the INLET of the inductor and the centerline of the foam inlet, above the bottom of the atmospheric storage tank, must be provided in order to properly manufacture the inductor. See Table 1. 5. INSTALLATION The BFZ Inductor is installed inside the pipe work between two flanges. The atmospheric storage tank and foam concentrate shut-off valve are installed prior to the inductor. 6. OPERATION The BFZ Inductor works using the injector principle, i.e. foam concentrate is sucked into the inductor without using a foam pump. Both low and high viscosity concentrates can be used in conjunction with the BFZ. Depending on the requested flow, pressure, foam concentrate type and proportioning ratio, the inductor will be equipped with the exact orifice at the entry of the foam pipe. Induction performance and suction height can be adjusted up to a physical limit of approximately 26 feet (8 m). To ensure accurate proportioning over the flow range of the inductor, minimum water inlet pressure of 58 psi (4 BAR) must be available during operation of the system. Please review the inductor dimension table for information on the minimum recommended length of straight pipe required upstream and downstream from the controller. 7. INSPECTIONS, TESTS AND MAINTENANCE NOTICE The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPC, and VdS, which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. Replaces page 173a-e, dated June 12, 2014. (Replaced foam concentrate part numbers; revised dimensions.)

Page 2 of 5 WARNING Any system maintenance or testing that involves placing a control valve or detection system out of service may eliminate the fire protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 8. AVAILABILITY FomTec Inductors are available through a network of domestic and international distributors. See the Viking web site for closest distributor or contact The Viking Corporation. 9. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Inductors without balancing valve To get 34% pressure drop over the inductor and get the inductor s proper function, the system after the inductor shall have a K-factor that is 27% larger than the K-factor of the inductor when using 3% foam and 30.5% higher when using 6% foam. If the K-factor on the system after the inductor is less than 22% larger than the K-factor of the inductor, then the suction ceases completely. If the K-factor on the system after the inductor is more than 27% (3% foam) larger than the K-factor of the inductor, the pressure drop over the inductor increases, but the flow is constant when you have the same inlet pressure on the inductor. Calculations: TABLE 1: SPECIFICATIONS Size FomTec Model Number Viking Part No. Foam Inlet K-Factor Range Min. Flow Max. Flow For use with Foam Between Flange Concentrate Viking Part No. Proportions U.S. Metric gpm (L/m) gpm (L/m) Americas EMEA/APAC 4 (DN 100) BFZ 4 F15922 1-1/2 19.0-69.4 275-1000 145 550 872 3300 2-9/32 (58 mm) 6 (DN 150) BFZ 6 F15923 2 38.1-138.8 550-2000 290.5 1100 1743.5 6600 2-3/4 (70 mm) BFZ F15924 2-1/2 57.2-208.3 825-3000 436 1650 2615 9900 BFZ S F15925 3 95.4-347.2 1375-5000 435.8 1650 4358.8 16500 3-11/32 (85 mm) 3-11/32 (85 mm)

Page 3 of 5 FIGURE 1 DIMENSIONS BFZ 4 AND BFZ 6 FIGURE 2 DIMENSIONS BFZ 8 AND BFZ 8S Size Foam Inlet (Grooved) A B C D F G J* Weight 4 (DN 100) 1-1/2 (38.1) 16-9/16 (421) 13-1/2 (343) 2-1/4 (58) 3/4 (20) 6-5/16 (160) 7-5/16 (187) 20 (51 cm) 15.4 lbs. (7 kg) 6 (DN 150) 2 (50.8) 16-15/16 (430) 13-3/16 (335) 2-3/4 (70) 1 (25) 8-7/16 (215) 9 (230) 30 (77 cm) 46.2 lbs. (21 kg) 2 1/2 (63.4) 17-1/ (435) 13 (330) 3-3/ (85) 1 (25) 10-5/ (270) 13-3/ (340) 40 (102 cm) 88.1 lbs. (40 kg) S 3 (76.2) 16-15/16 (430) 13 (330) 3-3/ (85) 9/16 (15) 10-5/ (270) 14-9/16 (370) 40 (102 cm) 101.4 lbs. (46 kg) * Straight pipe length required upstream and downstream Dimensions are approximate and subject to change without notice.

Page 4 of 5 FIGURE 3 WORKING RANGE OF BFZ 4 FIGURE 4 WORKING RANGE OF BFZ 6

Page 5 of 5 FIGURE 5 WORKING RANGE OF BFZ FIGURE 6 WORKING RANGE OF BFZ S Replaces page 173a-e, dated June 12, 2014. (Replaced foam concentrate part numbers; revised dimensions.)