Certificate and test report Nr. J144CON Coupling system for solar thermal applications. Test according to SPF test procedure: Test class A1

Similar documents
Flexible Metal Hose Products

HYDRALECTRIC LIMITED,

Expansion vessels for solar systems

RS Pro 300mm Long EPDM 15bar Braided Stainless Steel Hose RS Stock No

Flexible & Intelligent

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAD. Balancing valves DN 15-50

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

SPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

General Performance Data Hose Ref Minimum Bend. Safety Pressure at 20 C (BAR) Working Pressure at. Flow Rate at 3 bar (lit/min) Working Pressure

HYDRALECTRIC LIMITED,

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Installation and commissioning instructions 255 series and 256 series

CHECK VALVES APPLICATIONS

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

// ADapters GUIDelines

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

DS MB, MBF THREE PORT VALVES

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Self-operated Pressure Regulators for special applications

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

k valve ½ (15) ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF installation guide aylesbury For valve sizes (DN):

Proportional Relief Valves

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

KAX VALVE ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF INSTALLATION GUIDE AYLESBURY FOR VALVE SIZES (DN):

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Installation and Operation Manual for Solar Systems with KTU R Collectors

776 Cryogenic Safety Valve

STAD. Balancing valves DN (MD60, MD61, MD62)

Pressure Reducing Valve DMV 755

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Propor tional Re lief Valve s

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series 8500 Expansion Compensators. Catalog 674H

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Expansion Thermometers Stainless Steel Series, Model 70

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Pressure regulating valves Types OFV, OFV-SS

Model MTB-ASME Vertical Bladder Tanks

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Corrugated Hose Loop Calculations

PLEASE NOTE: Pressures for 200mm (8ins) and 250mm (10ins) are based on the use of METALFLEX Braided Braid

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

TA-FUSION-P. NPT threads / ANSI flanges

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Art PRESSURE REDUCER

Horizontal Bladder Tanks

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Coiling Tube with Twist-Proof Fitting

Vertical Bladder Tanks

AVP-F. p setting range (bar) Code No. 003H6200

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Y-Pattern Strainer Valves Range

Torque Tube TB300 Digital Transmitters

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

BUL: 3-way unit valve, PN 16

Discussion and guidance on the definition and qualification of porous loads

tubepress press procedure

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

JUMO dtrans p30 Pressure Transmitter

DSL, DSH: Specially designed pressure limiter

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Engineering Data Sheet

Electronic relative and differential pressure switch type 616

FRIGOFLEX is an innovative system designed for the conveyance of R134, R404, R407, R410 refrigerant gases and other specific fluids.

Types and approvals. Page 1/6. Data Sheet

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

SV5 Safety Valve Installation and Maintenance Instructions

Pilot Check Valve: Metal Body Type

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Gas Welding Hoses and connections, the weak link

ptfe and stainless steel hoses

Installation, operation & maintenance manual - original version

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DTG - LCD Digital Temperature Gauge USER MANUAL

55.109/1. BUT: Three-way unit valve, PN 16. Sauter Components

756 Safety Relief Valves

Transcription:

Institut für Solartechnik Hochschule Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Orderer: MFC S.r.l. Via Tito Speri, 32B IT-25065 Lumezzane (BS) Certificate and test report Nr. J144CON Coupling system for solar thermal applications. Test according to SPF test procedure: Test class A1 Fast coupling system for corrugated stainless steel pipes page 1 of 7 pages

Table of content: page 1. Description of the sample... 3 1.1 Product information and technical description... 3 2. Test methods and results... 4 2.1 General remarks... 4 2.2 Test procedure and test parameters... 4 2.3 Photographs of test samples... 5 2.4 Notes... 7 2.5 Result... 7 3 Remarks... 7 page 2 of 7 pages

1. Description of the sample 1.1 Product information and technical description Manufacturer: Model: Tested sample: Connection Type: Application range Nominal diameter: Description of sample: Materials Heat transfer media Application limitations MFC S.r.l. - 25065 Lumezzane (Italy) Fast coupling system for corrugated stainless steel pipes MFC 5051-Cu22 Corrugated stainless steel pipe to copper pipe Pipework connections for solar thermal installation. DN16 x Ø22mm Metallic coupling system for connecting corrugated stainless steel tubes to standard copper pipework. Brass CW614N (CuZn39Pb3) - EN12164 Ethylene or Propylene glycol / Water not specified Fig. 1 Cross section of the mounted fitting system page 3 of 7 pages

2. Test methods and results 2.1 General remarks The test procedure is intended to assess the resistance of the connection system against the assumed thermal load encountered during the lifetime of a typical solar installation with state-of-the-art solar collectors (selective absorber coating, solar glazing). The test concerns only the fast coupling system for corrugated stainless steel pipes connectors, i.e. only the connection of the corrugated stainless steel tube. Different couplings are available to connect corrugated s/s tubes to copper tubes, soldered spigots, corrugated tubes, and other male or female standard connection components. As long as the tested fast coupling system for corrugated stainless steel pipes connectors is used, the test J144 is valid for all these types as it concerns only the connection of the corrugated tube. Three identical pipe-work samples including a corrugated stainless steel tube have been tested. The samples have been assembled by the manufacturer in a professional manner. The test procedure does not cover the corrugated tube itself. The connector system is not intended to be used as compensator between solar thermal collectors. 2.2 Test procedure and test parameters Test according to SPF standard. Test Class A1 reduced to the thermal loads. The 500 thermal shocks represent the stagnation cycles to be expected during the lifetime of a solar thermal system Three pipe work samples are tested in parallel. None of the samples is allowed to fail for passing the test. During the test procedure the samples are flowed through with glycol at a pressure of 10 bars maximum. The test samples were installed without any static misalignment (installation tolerance) and the SPF test procedure is reduced to the thermal shocks. No further static or dynamic mechanical loads are applied during the whole test procedure. The test procedure is made up of 500 thermal shocks as follows: The temperature of the fluid (and hence the fitting) is increased up to the maximum temperature of T high =180 C (±5 C). Upon thermal stabilisation of the whole system a thermal shock is triggered and the samples are flushed with fluid at the lower temperature level T low <80 C. The decay time of the shock is in the range of 5 seconds. The time required for one complete temperature cycle is approx. 30 minutes. These thermal shocks represent the thermal loads that occur during the filling procedure of a drained collector system. page 4 of 7 pages

2.3 Photographs of test samples Figure 2: (before test start) For the installation the corrugated s/s tube is inserted form the left side. The brass sleeve is then pressed on the end of the corrugated tube by fixing the nut. Figure 3: (before test start) Ready installed coupling system. Figure 4: (before test start) Ready installed coupling system. page 5 of 7 pages

Figure 5: (before test) Test samples on test stand before the test start Figure 6: (after test) Samples installed on the test rig. No leakage or any other problems have been observed. Figure 7: (after test) Sample P1 opened. No visible signs of deterioration that could indicate reduced lifetime or leakage page 6 of 7 pages

2.4 Notes The test results and the certificate are valid for fluids in the liquid phase. The behaviour of the fitting for vaporous heat transfer media as well as evaporation and condensation effects are not assessed with the present test procedure. The fittings must be used together with corrugated stainless steel tubes which are able to absorb the mechanical movements caused by thermal elongations, mechanical misalignment and similar. 2.5 Result No leakage, deficiency and no other failures have been observed during the test. The fast coupling system for corrugated stainless steel pipes is therefore considered as suitable for the use in solar thermal installations. The fast coupling system for corrugated stainless steel pipes in the tested dimension therefore fulfils the requirements of the SPF test procedure class A1 and is certified under the SPF number J144CON. The certificate is valid for 5 years. 3 Remarks This report must not be copied except in full. The test results only refer to the tested sample. Rapperswil, 27.05.2011 Dr. Andreas Bohren Head SPF Testing August Thrier Responsible for the testing page 7 of 7 pages