Hydronic Systems Balance

Similar documents
The Advancement of Pressure Independent Technology

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Figure 4 Figure 5 Figure 6

HVAC Hydronic Pumps: B&G Triple Duty Valve for Proportional Balance

Back to Basics: Pumping Systems RM ASHRAE TECH CONFERENCE

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

Process Dynamics, Operations, and Control Lecture Notes - 20

TESTING OF BELIMO PRESSURE INDEPENDENT CHARACTERIZED CONTROL VALVES

Integrating Aeration Blowers with Most-Open-Valve

Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Gerald D. Anderson. Education Technical Specialist

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

CONTROL VALVE WHAT YOU NEED TO LEARN?

Centrifugal Pump Intro

S-CO 2 Brayton Recompression Loop Design and Control

Lesson 6: Flow Control Valves

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

RadKits (Piping Packages)

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Application Worksheet

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

FloCon Commissioning Modules DESIGN GUIDE - JUNE Variable Flow Systems & Solutions brought to you by Hurlstones

Some system examples

Pressure Independent Control Valves

SIZING THE WELL-X-TROL

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

Consider the design of a central chilled water cooling system for a clubhouse and

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

SINGLE VALVE WITH LOW-FLOW BYPASS

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

Pressure Independent Control Series

BACK PRESSURE / SUSTAINING

Chapter 10: Bidirectional Flow Controls

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

Two Sides of the Same Coin

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR

BACK PRESSURE / SUSTAINING

485 Annubar Primary Flow Element Installation Effects

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

The Discussion of this exercise covers the following points:

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

ELECTRONIC VALVE SIZING AND SELECTION

Pressure on Demand. Air Pressure Amplifiers

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

Pump-Fan-Compressor Sizing

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Valve Sizing Considerations. Steven Hocurscak Metso Automation

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

AIRMOUNT VIBRATION ISOLATION

Engineering Letter. Pump Protection

SIZING OF WATER PIPING SYSTEM

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

VBS-9263 Series. Application. Features. Applicable Literature

Bermad Pressure Reducing. Model: 42T

Joint Expo 2012 February 7-8, 2012 BASIC HYDRAULICS

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

VB-7263 Series. Application. Features. Applicable Literature

Pressure independent control valve (PICV) FLOWMATIC

Expansion Tank Design (Chilled Water)

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

TECHNICAL INSTRUCTIONS Iron Body Series 597 SI

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

Union joints 23. Fulfilling Solutions Through Knowledge

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

VB-7273 Series. Application. Features. Applicable Literature

Bell & Gossett ESP-Systemwize Pump Selections

Gas Lift Valve Testing

Cavitation in Valves

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

IE098: Advanced Process Control for Engineers and Technicians

International Research Journal of Electronics and Computer Engineering Vol 1(3) Oct-Dec 2015

Considering Control Valve EFFICIENCY

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

Drilling Efficiency Utilizing Coriolis Flow Technology

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

FILTER BYPASS CONTROL

Plant design and control valve selection under increasing cost and time pressure - Part I

Full Range Pressure Compensating Variable Flow Control

V311. Venta. Three-way Plug Valve, Flanged PN 16

Methods of Rating Flow

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Characterizers for control loops

Transcription:

Hydronic Systems Balance

Balancing Is Misunderstood Balancing is application of fundamental hydronic system math Balance Adjustment of friction loss location Adjustment of pump to requirements By definition: Achieve ±10% Flow rate or better for required heat transfer of 97.5% Balancing cannot make up for poor design and component choices

Evaluation Method: System Curve Math System and Component Flow Coefficients q C V! P or C V q! P Components in series 1 C 2 VE 1 C 2 V1 1 C 2 V 2 1 C 2 V 3... 1 C 2 Vn Paths in parallel C VE C C C... V1 V 2 V 3 C Vn

Evaluation Method: System Curve Math Pump & System Curve & Spreadsheet Differential Pressure (Feet of Head) C V Pump Operation: Always At System & Pump Curve Intersection 2.31 Feet 1 PSI Flow Rate (Gallons Per Minute)

Evaluation Method: System Curve Math Pump & System Curve & Spreadsheet Differential Pressure (Feet of Head) C V Parallel Paths Add To The Side Series Components Add Up 2.31 Feet 1 PSI Flow Rate (Gallons Per Minute)

1960 1970 1980 2000 Hydronic systems have progressed over the years Static Balancing Dynamic Balance Focus on chilled water Variable speed pumps Pressure regulated control valves

Static Balance Closely associated with throttling valves Position! CV! Flow Calculation Accuracy of differential sensor needs to adapt as valve closes Proportional balance Pump undersized, all valves receive percentage of flow

Branch Branch Riser Pressure Drop Ratio 4:1 2:1 1:1 and less Percent Design Flow All Circuits 95% 90% 80% and less Note: Based on constant speed pumps Riser Example: 40 Ft Head loss in branch 2:1 Ratio equals 20 feet allowed in supply and return piping, or 10 per riser. Source Circuits can receive 90% design flow regardless of what other valves do in system

240 160 80 100 20 20 40 80 40 80 40 20 80 20 20 20 20 20 20 Source 40 40 40 40 40 40 20 20 20 20 20 20 80 40 80 40 80 40 240 160 80

Source 240 GPM 160 80 40 100 20 20 B C 1 A 4 30 7 F E D 100 20 20 240 GPM 160 80 80 GPM 30 30 12 40 GPM 30 10 30 30 3 20 20 6 30 30 8 20 20 11 30 30 40 GPM 40 GPM 5 2 40 GPM 30 9 80 30 30 30

Friction Loss Charts Published by ASHRAE & Hydraulic Institute D/W Eqn. Add 15%!

Calculate Head Loss & Flow Requirement SEGMENT A B C 1-2 2-3 3-4-6 3-5-6 6-7 2-8 8-10-11 8-9-11 11-7 7-12 D E F Flow 240 160 80 80 40 20 20 40 40 20 20 40 80 80 160 240 Size 4" 3" 2.5" 2.5 1.5 1.25 1.25 1.5 1.5 1.25 1.25 1.5 2.5 2.5" 3" 4" Length 100' 20' 20' 30 30 60 60 30 30 60 60 30 30 20' 20' 100' H F Rate 3 5.5 4.5 4.5 12.5 9 9 12.5 12.5 9 9 12.5 4.5 4.5 5.5 3 Friction Loss 3 1.1 0.9 1.35 3.75 5.4 5.4 3.75 3.75 5.4 5.4 3.75 1.35 0.9 1.1 3 Fittings 2 2 2 2 2 2 2 2 2 2 2 2 Service Valves 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Coil 17 17 17 17 Control Valve Balance Valve Source 30 Total 5 3.1 2.9 3.35 7.75 26.4 26.4 7.75 7.75 26.4 26.4 7.75 5.35 4.9 5.1 37 PATH TOTAL A-1-2-3-4-6-7-12-F 5 3.35 7.75 26.4 7.75 5.35 37 92.6 A-1-2-3-5-6-7-12-F 5 3.35 7.75 26.4 7.75 5.35 37 92.6 A-1-2-8-10-11-7-12-F 5 3.35 7.75 26.4 7.75 5.35 37 92.6 A-1-2-8-9-11-7-12-F 5 3.35 7.75 26.4 7.75 5.35 37 92.6 A-B-1-2-3-4-6-7-12-E-F 5 3.1 3.35 7.75 26.4 7.75 5.35 5.1 37 100.8 A-B-1-2-3-5-6-7-12-E-F 5 3.1 3.35 7.75 26.4 7.75 5.35 5.1 37 100.8 A-B-1-2-8-10-11-7-12-E-F 5 3.1 3.35 7.75 26.4 7.75 5.35 5.1 37 100.8 A-B-1-2-8-9-11-7-12-E-F 5 3.1 3.35 7.75 26.4 7.75 5.35 5.1 37 100.8 A-B-C-1-2-3-4-6-7-12-D-E-F 5 3.1 2.9 3.35 7.75 26.4 7.75 5.35 4.9 5.1 37 108.6 A-B-C-1-2-3-5-6-7-12-D-E-F 5 3.1 2.9 3.35 7.75 26.4 7.75 5.35 4.9 5.1 37 108.6 A-B-C-1-2-8-10-11-7-12-D-E-F 5 3.1 2.9 3.35 7.75 26.4 7.75 5.35 4.9 5.1 37 108.6 A-B-C-1-2-8-9-11-7-12-D-E-F 5 3.1 2.9 3.35 7.75 26.4 7.75 5.35 4.9 5.1 37 108.6

Automated Control Energy Energy is is lost lost proportionally to to the the outside outside temperature q = UA(T UA(T i -T i -T O ) O ) The The controller controller output output signal signal act acts s in in a a proportional proportional m anner anner to to the the difference difference in in the the actual actual from from the the desired desired tem temperature adding adding what what is is lost lost

Engineering Practice: Valve Authority Control relies on predictable linear control Coil and valve look like a straight line The weather changes, we add or subtract flow proportionally to the worst case day Coil Heat Transfer Control Valve Controller 100% 100% 100% % Coil Heat Transfer Output 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% % Required Water Flow 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% % Required Heat Transfer 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 20% 40% 60% 80% 100% 0% 20% 40% 60% 80% 100% 0% 20% 40% 60% 80% 100% % Required Water Flow % Required Heat Transfer (Control Signal) % Design Load

Conventional Modulating Valves Need stable system pressure to properly control Require large pressure drops for linear control Valve Authority means the valve is selected to be ½ pump pressure (head) Fine tuning in field; Balancing Extra design calculations

Traditional Valve Application 3 HP Traditional throttled constant speed pump and control valve Differential Pressure (Feet of Head) Minimal pressure changes 5 HP Controls using conventional valves rely on flat curve pumps to stabilize system pressure and make coil heat transfer response predictable Flow Rate (Gallons Per Minute)

SEGMENT A B C 1-2 2-3 3-4-6 3-5-6 6-7 2-8 8-10-11 8-9-11 11-7 7-12 D E F Flow 240 160 80 80 40 20 20 40 40 20 20 40 80 80 160 240 Size 4" 3" 2.5" 2.5 2 1.5 1.5 2 2 1.5 1.5 2 2.5 2.5" 3" 4" Length 100' 20' 20' 30 30 60 60 30 30 60 60 30 30 20' 20' 100' H F Rate 3 5.5 4.5 4.5 3.25 3.75 3.75 3.25 3.25 3.75 3.75 3.25 4.5 4.5 5.5 3 Friction Loss 3 1.1 0.9 1.35 0.98 2.25 2.25 0.98 0.98 2.25 2.25 0.98 1.35 0.9 1.1 3 Fittings Service Valves Coil 17 17 17 17 Control Valve 43.7 43.7 43.667 43.67 Balance Valve Source 30 Total 3 1.1 0.9 1.35 0.98 62.9 62.9 0.98 0.98 62.917 62.92 0.98 1.35 0.9 1.1 33 PATH TOTAL A-1-2-3-4-6-7-12-F 3 1.35 0.98 62.9 0.98 1.35 33 103.567 A-1-2-3-5-6-7-12-F 3 1.35 0.98 62.9 0.98 1.35 33 103.567 A-1-2-8-10-11-7-12-F 3 1.35 0.98 62.917 0.98 1.35 33 103.567 A-1-2-8-9-11-7-12-F 3 1.35 0.98 62.92 0.98 1.35 33 103.567 A-B-1-2-3-4-6-7-12-E-F 3 1.1 1.35 0.98 62.9 0.98 1.35 1.1 33 105.767 A-B-1-2-3-5-6-7-12-E-F 3 1.1 1.35 0.98 62.9 0.98 1.35 1.1 33 105.767 A-B-1-2-8-10-11-7-12-E-F 3 1.1 1.35 0.98 62.917 0.98 1.35 1.1 33 105.767 A-B-1-2-8-9-11-7-12-E-F 3 1.1 1.35 0.98 62.92 0.98 1.35 1.1 33 105.767 A-B-C-1-2-3-4-6-7-12-D-E-F 3 1.1 0.9 1.35 0.98 62.9 0.98 1.35 0.9 1.1 33 107.567 A-B-C-1-2-3-5-6-7-12-D-E-F 3 1.1 0.9 1.35 0.98 62.9 0.98 1.35 0.9 1.1 33 107.567 A-B-C-1-2-8-10-11-7-12-D-E-F 3 1.1 0.9 1.35 0.98 62.917 0.98 1.35 0.9 1.1 33 107.567 A-B-C-1-2-8-9-11-7-12-D-E-F 3 1.1 0.9 1.35 0.98 62.92 0.98 1.35 0.9 1.1 33 107.567

Control Valve We reduced head loss to 66 We want 50% Authority, so size valve for _?_ 66 (28.6 PSI) q C V! P 20 GPM 20 66 2.31 C C V V 66 2.31 3.74

Control Valve Selection Required C V = 3.75 Pipe Size = 1½ Rules of Thumb One pipe size smaller 5 PSI; C V = 9

Valve Authority C Supply VE C! P MAX V Valve C 2 V V! P MIN! ➂C C! P! P 2 V C MIN MAX V Comp Ret urn Components have constant flow coefficient Valve coefficient is variable Calculate equivalent coefficient at valve stroke using spreadsheet

100% 90% 80% 1 Valve C V =11.6! =9% 70% % Flow 60% 50% Closest C V Valve C V =4.6! =43.7/109=40% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % Lift

Balanced 3 Way Valve Authority Supply 130% Ret urn 120% 110% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Shown @! = 50%

Un-balanced 3 Way Valve Authority Supply 140% Ret urn 130% 120% 110% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Shown @! = 50%

Balance? In this case balance would adjust the coil balance valves in Branches 2 & 3 to account for riser loss of about 2 and 4 Large systems become complicated adjustments Broken up into logical groups System changes often require major re-balance Example: Look at pump and system curve intersection points

140 Closest Sized Control Valve Balanced; Green Line Unbalanced; Red Line 130 120 110 100 90 80 70 60 50 40 30 20 10 7.5 HP 10 HP Pump selected to provide high control valve authority, increasing required head and horsepower for pump, but ensuring control 0 0 50 100 150 200 250 300 350 400 450 500

100 1 Control Valve 90 80 Balanced; Green Line Unbalanced; Red Line 70 60 50 40 30 20 10 5 HP 7.5 HP Pump selected to provide less control valve authority, decreasing required head and horsepower for pump, but affecting control 0 0 50 100 150 200 250 300 350 400 450

Larger Pump Comparison of Control Valves 140 Balanced; Green Line Unbalanced; Red Line 130 120 110 100 90 80 70 60 50 40 30 20 10 1 Valve shown on ½ pump selected to provide high control valve authority. System operates with higher flow rates, unless speed or impeller adjustments are made to pump The The traditional traditional Balance Balance problem low problem low authority authority control control valve valve too too big big of of a pump pump 10 HP 7.5 HP 0 0 50 100 150 200 250 300 350 400 450 500

Static Balance; Riser Balance Open

Why the Emphasis on Control Valve? % Hours 25.0% 20.0% 15.0% 10.0% 5.0% Cumulative Hours % Design Flow 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% % Design Flow / Cumulative Hours 80% of operational cooling uses less than 20% of design flow 97% of operational hours covered by 50% design flow 50% flow can be 12.5% design horsepower 0.0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % Cooling Load 0%

Optimizing Hydronic System Energy Efficiency! Flow 3! BHP Means applying variable speed drives to save maximum energy Small changes in flow mean big savings in pump horsepower Hydronic system and controls must be designed to take advantage of potential savings Many variable speed pump systems don t achieve their predicted performance

IECC 503.4.3.4 Building Code Hydronic Systems! 300,000 Btu/Hr. in design output capacity supplying heated or chilled water to have special controls Temperature to be capable of being reset by 35% of the design supply to return water temperature difference Capable of reducing system pump flow by 50% of design flow utilizing adjustable speed drives on pumps where 1/3 of total horsepower is automatically turned off or modulated

Variable Speed Pumping Offers Tremendous Energy Saving Potential 3 HP Traditional constant speed pump and control valve Differential Pressure (Feet of Head) Head Reduced 80% + ¼ HP Speed = 37% 5 HP Speed = 100% Standard Temperature Control Valves Won t Perform Correctly! Flow Rate (Gallons Per Minute)

Variable Speed Pump Problems Temperature control worse or unstable How to balance a VS pump system ASHRAE techies have debated subject for years Diversity: Short flow Paradigm change; System curve & commissioning Systems don t seem to follow system curve Work in area of operation Variable speed systems don t seem to achieve desired savings

Example Modification Convert to three floors Group valves into one Source

67 Feet Differential Pressure Transmitter 1 2 3 80 GPM 80 GPM 80 GPM System Requires 240 GPM Chiller Rated @ 200 Tons, 400 GPM Pump Specified 400 GPM @ 70 Feet Branch Pipe, Valves, Coil and TC Valve specified at 67 Loss, via set point specified for variable speed pump system. Branch 1 required balance: Maximum Pump speed set to match flow and head required for branch. Branch 2 & 3 required balance: Balancing valves adjusted to make up for distribution head loss due to location. Note: Preferable application of dynamic balance method Rated @ 240 GPM Source

110.00 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 Control Area Outline; Shown for balanced high authority valve and! P sensing across far branch. There is low valve interactivity because riser distribution losses are quite low as compared to the controlled branch. The system curve is shown in red, and control points in blue. The line under the system curve reflects less water available for control than required, potentially impacting comfort. Above the curve reflects more energy use by pump. 0.00 0 50 100 150 200 250

110.00 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 The The Area Area is is a a series series of of Pump Pump & & Controlled Controlled System System Curve Curve intersection intersection points points at at different different controlled controlled ATC ATC valve valve positions. positions. They They outline outline the the controlled controlled response response of of the the variable variable speed speed drive drive differential differential pressure pressure regulator regulator 10.00 0.00 0 50 100 150 200 250

44 Feet Differential Pressure Transmitter 1 2 3 80 GPM 80 GPM 80 GPM System Requires 240 GPM Pump Specified 240 GPM @ 110 Feet TC Valve specified at 44 loss, via set point specified for variable speed pump system. Branch 1 required balance: Maximum Pump speed set to match flow and head required for valve. Branch 2 & 3 required balance: Balancing valves adjusted to make up for distribution head loss due to location. Note: Branch 1 coil loss now added to distribution system piping due to control sensor location. Rated @ 240 GPM Source

110.00 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 The same pump and system, this time with the sensor placed across the control valve. Note the transformation in area due to the control effects of maintaining the differential pressure across the valve. The pump operates at lower required energy due to the lower! P setpoint, but interactivity increases. These same effects are seen when friction losses are distributed to the riser piping. 0.00 0 50 100 150 200 250

Solutions: Automatic Flow Limiting Flow limiting valves fix variable speed control area problems Flow limiting valves do not proportionally balance Diversity selection less than coil block load leads to issues Control valve still has fundamental controller gain problem under variable speed

Dynamic Balance; Pre-adjusted Branch

Adding to Problem Proportional control dynamic is changed in conventional modulating valves Controller begins to hunt Differential Pressure (Feet of Head) ¼ HP Speed = 37% 5 HP Speed = 100% 2 HP Speed = 74% Load (Control Signal) 100% 74% 37% Flow Required Need Get s Need Get s Need Get s Conventional Valve Regulated Valve 10 GPM 10 GPM 10 GPM 10 GPM 4 GPM 4 GPM 3 GPM 4 GPM 1 GPM 1 GPM.4 GPM 1 GPM Flow Rate (Gallons Per Minute)

Two Valves Integrated In One Body P1 P2 P3 The advanced design ensures stable pressure on temperature control valve at all times TC Valve always has 100% authority M Other designs do not P1 P2 P3

Conventional Control Valves Require Iterative design calculation First pass; determine piping losses Second pass; size valve, determine pressure drops and balance pipe sizes and pressure drops Stable Differential Pressure Balancing to tune valve to system Need extra flow? re-size or increase pressure Regulated Valve Provides Known pressure drop Calculate pipe and pump size once Less required! P for control set point Consistent flow characteristic Valve inherently balances system and can proportion flow for diverse flow applications Need extra flow? adjust valve setting in field

12 Feet Differential Pressure Transmitter 1 80 GPM 2 80 GPM 3 80 GPM Rated @ 240 GPM Source

Dynamic Balance; PICV Controlled Pressure & ATC

PICV Helps Move Pressure SP Down 110.00 100.00 90.00 80.00 Branch SP 70.00 60.00 Valve SP 50.00 40.00 30.00 PICV SP 20.00 10.00 0.00 0 50 100 150 200 250

Case Against Balancing Valves ASHRAE Journal July 2009

90 80 70 Pump Over Specified; Required adjustment for proper operation, either speed or impeller reduction Pump Specified 400 GPM @ 70 Feet 60 50 40 Variable Speed Pump System Curve with Controlled Head 30 20 10 Constant Speed Pump System Curve 0 0 100 200 300 400 500

10 Feet 1 120 GPM Valve = Open System Requires 180 Tons, 360 GPM Chiller Rated @ 200 Tons, 400 GPM Pump Specified 400 GPM @ 70 Feet Bypass set for coil pressure drop 120 GPM Branch Pipe, Valves, Coil and TC Valve specified at 10 Loss, via set point specified for variable speed pump system. 2 Bypass set for coil pressure drop 120 GPM Branch 1 required balance: Bypass port must be balanced to pressure drop of coil. Either (A) Pump Impeller trimmed to match required head, 58.6 Feet, or (B) Pump speed fixed at 91.5% to match required speed for oversized pump 3 Bypass set for coil pressure drop Branch 2 & 3 required balance: Bypass port must be balanced to pressure drop of coil. Balancing valves adjusted to make up for distribution head loss due to location. Rated @ 400 GPM Source

120 GPM Bypass set for coil pressure drop 180% 160% 140% 120% 100% AB Installed Characteristic; Effects of hydraulic losses on valve control of minimal pressure drop e.g. Valve Authority 80% 60% 40% 20% A B Laboratory Characteristic; Constant differential pressure maintained under testing 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

80 70 Article Pump Curve (Figure 3) 60 50 40 30 20 10 (3) 3-Way valves at 0% or 100% valve position Same valves at 50% valve position. Off pump curve and cavitating due to authority and poor pump selection 0 0 100 200 300 400 500 600 700

80 90% 70 Efficiency 80% 60 50 Full Size Pump Curve 70% 60% 50% 40 30 Trimmed Impeller Curve 40% 30% 20 10 Three Way Valve System Curves as Valve Goes from 0-100% Stroke 20% 10% 0 0% 0 100 200 300 400 500 600 700 800 900

100% 90% 80% Installed Characteristic; Valve Authority (Red/ Solid) (In the field, variable! P) 70% % Valve Fluid Flow 60% 50% 40% 30% 20% 10% Linear Reference Modified Equal Percentage Characteristic (Blue/ Dots) (In the lab, constant! P) 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % Stem Position (Control Signal)

100% 90% 80% 70% Chilled Water Coil Sensible Heat Transfer Characteristic % Coil Heat Transfer 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % Fluid Flow

100% Est. Gain 90% 80% Chilled Water Coil Sensible Heat Transfer Characteristic (Blue Line) % Valve Fluid Flow 70% 60% 50% 40% Controlled Sensible Heat Transfer Characteristic (Green Line) Installed Characteristic; Valve Authority (Red/ Solid) (In the field, variable! P) 30% 20% 10% Linear Reference Ideal Gain Modified Equal Percentage Characteristic (Blue/ Dots) (In the lab, constant! P) 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % Stem Position (Control Signal) % Valve Flow Rate

Impact Article doesn t really point out impacts well 3 Way Unbalanced and oversized pump 3 Way Balanced 58000 KWH $4423 42000 $3224 2 Way Valve with Authority Issues & Oversized Pump 24,500 KWH $1872 2 Way High Authority (PICV) No Pump Adjustment 12900 KWH $986 2 Way PICV with Pump Adjusted 8500 KWH $647

Balance Counts ALL systems that move fluid probably benefit from proper adjustment In hydronics PIC Valves help maintain Proper Temperature Control (No Hunting) Reduced Pump Differential Set Point Overcome with controllers big system issues like diversity Problems don t necessarily show themselves in Commissioning Reconsider protocols with emphasis on control signals Pump Curves & System Curves