Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Similar documents
CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Chlorinator MODEL MK-I

Chlorinator. MODEL C-731 (Floor Mounted)

Highest Quality. Gas Chlorination Systems

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

ProMinent Gas Chlorination

Full-Vacuum Chlorinator C 2212 MB / 1

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Section GAS CHLORINATION SYSTEM

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

ACV-10 Automatic Control Valve

Chemical Injection Technologies Installation/Service Bulletin

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Model VR6 System. Installation, Operation & Maintenance

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Vaporizer Piping Liquid Chlorine Manifolds

VACCUPERM Vacuum chlorine gas dosing systems

BULLETIN 901 SAFE RELIABLE ECONOMICAL REGAL GAS CHLORINATORS SULPHONATORS AMMONIATORS

Workhorse-15 Oxygen Generator

Petro-Chemical & Analyzer Sampling Systems

Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Oxygen Usage Best Practice Guide

Variable Area Flow Meters

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Operating Instructions

MEDICAL EQUIPMENT CATALOG

Petro-Chemical & Analyzer Sampling Systems

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Instruction Manual ADVANCE TM Wall Panel Gas Feeders Series WP70CV3

AUTOMATIC HOSE TEST UNIT, TYPE SPU

RD(H)20/25 Pressure-Reducing Regulator User Manual

Pressure Automated Calibration Equipment

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

OWNER S TECHNICAL MANUAL

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Columbus Instruments

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

Instruction Manual ADVANCE Series 480 Vacuum Regulator

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Direct Operated Precision Regulator Modular Style. Standard Specifications

TECHNICAL DATA. Q = C v P S

FOAM TANK (1/2) DATA SHEET

KFI Approved. High Pressure CO2 System Technical Datasheets

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

MUD 1. Vent check valves. Instruction and maintenance manual.

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Description Advanced Features Typical Applications

AUTOMATIC GAS MANIFOLDS

HumiSys HF High Flow RH Generator

TECHNICAL DATA. Q = C v P S

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Inert Air (N2) Systems Manual

TEST SPECIFICATION NYT-909-C

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

ECS Protector Nitrogen Inerting Vent (PAV-WN)

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Corporation Stops Technical Bulletin

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

System Pressure Manager Standard & System Pressure Manager Plus

LRS(H)4 Pressure-Reducing Regulator User Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

NGN Series nitrogen generator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Types 749B and R130 Changeover Manifolds

Model 106 DPI "Micro-switch" Installation and Operating Instructions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

HGC-200 Hydro Gas Chlorinator

DPC-30 DPC-100. Reference Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

21700 Nordhoff St. Chatsworth, CA Phone

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure Dump Valve Service Kit for Series 2300 Units

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

TECHNICAL DATA. Q= Cv S

MANUAL GAS MANIFOLDS

Autocalibration Systems For In Situ Oxygen Analyzers

Model PDT Dewpoint Transmitter

Integral type Differential pressure flowmeter VNT Series

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Wallace & Tiernan Flow Measurement Equipment

Pneumatic spool valve islands

PERFORM Operating Document

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

Transcription:

Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed values Modern, improved, durable external design Convenient, quick, overall internet design Fully automatic control by the AUTOVALVE responding to external signals in variety Safe& reliable all-vacuum operation Capacity range up to 10,000 PPD(200kg/hr) Liner feed rate by AUTOVALVE of Sonic Flow Design New gas filter system in vacuum line AQUS Series CH4200 Floor Mounted chlorinators are vacuum operating solution feed devices available with either manual or automatic control. Each chlorinator is composed of three parts; a vacuum regulator, a control module and an ejector. The blue and silver cabinet which encloses the control module is constructed of fiberglass - reinforced polyester and has a smooth, easily maintained finish. Chlorinator feed rates are dependent on the maximum withdrawal rates from the gas source. Maximum chlorinator capacities range from 50 to 10,000 lb/day (0.1 to 200kg/hr). When automatic control is required Automatic Flow Control Valve mounted within the control module responds to control signals from a water flow transmitter or a chlorine residual analyzer controller. Several control modules may be used together to construct a system for multipoint application of chlorine. The gas flow from the vacuum regulator may be divided to feed more than one application point with the flow to that point being either manually or automatically controlled. The sum of the flows to each application point cannot exceed the capacity of the vacuum regulator. Automatic changeover systems use two vacuum regulators without the necessity of a separate changeover valve. The Automatic Flow Control Valve controller is a state-of the art, micro-processor based device for automatically controlling the feed rate of the application gas based on process control parameter. The controller is a very user-friendly interface and easy to operation for automatic and manual control. Display is a 2-line 16 character, back lighted LCD. It allows easily understood visual indication of specific application parameter. Units similar to those for feeding chlorine (but with different materials of construction) are available for feeding sulfur dioxide, ammonia and carbon dioxide gases. The maximum capacity of the feeders is 1900 lb/day (38kg/hr) for sulfur dioxide, 975 lb/day (20kg/hr) for ammonia, and 6200 lb/day (30kg/hr) for carbon dioxide. Design Features Modern Design : The chlorinators feature compact modular design with cabinets identical in color to other AQUS chlorinators and analyzers. Integrated circuits and a single corrosion resistant electrical enclosure increase reliability of the automatically controlled models.

Control Signals : Automatic Flow Control Valve insures positive response to electric signals representing either water flow, chlorine residual measurement or both flow pacing and residual control signals can be accepted simultaneously by the Automatic Flow Control Valve. Safety : Vacuum operation provides protection for plant operating personnel and equipment. Built-in design features prevent damage to the chlorinator under abnormal operation conditions. Versatility: The availability of separate chlorinator components allows for the selection and mounting in locations most suitable for the operation of the chlorination system. Laser System (Option) : Laser sensor measuring actual float level& output 4~20mA Engineering Specifications Capacity and expenditure The capacity of gas dispenser depends on the maximum capacity of the feed gas and capacity of vacuum regulator. Gas injection PPD 10 25 50 100 200 500 1,000 1,500 kg/hr 0.2 0.5 1.0 2.0 5.0 10 20 30 PPD 2000 3000 4000 6000 8000 10000 kg/hr 40 60 80 120 160 200 Power supply condition Flow rate control equipment: 115/230 VAC(± 15%), 50/60 Hz Control Module Ejector vacuum level is indicated by a gauge reading in English and metric units mounted on the front of the control module. For multipoint application of chlorine solution, each point requires a separate control module containing a flowmeter, a differential pressure regulator. Each application point also requires and ejector. Any combination of capacities may be used as long as the total does not exceed the capacity of the vacuum regulator. Available optionally are alarm switches to proved indication of loss of vacuum in the event of ejector failure, or excess vacuum as would occur when the gas supply is interrupted or depleted. These switches are rated at 10 A 120 V. Flowmeter Standard metering tubes are available with the following maximum capacities: 10, 25, 50, 100, 200, 500, 1000 and 2000 lb/day of chlorine gas. The equivalent metric capacities are 0.2, 0.5, 1.0, 2.0, 5.0, 10, 20, 40 kg/hr. Metering tubes have dual scales in English and metric units. Should it be desired to recude the quantity, or eliminated control valves are available. Flowmeter range ability is 20:1 for any one metering tube. Materials of Construction : PVC, Tantalum, VitonTM E.I. Du Ponts Co., Hastelloy C-276 Haynes international, Inc., TeflonTM E.I. Du Pont Co., KYNAR Pennwalt Corp., silver, leaded navel brass, and extra heavy duty borosilicate glass are used in the construction of the chlorinator and ejector. The control valve tapered tube is glass, the plug material is tantalum and the valve operator is in a non metallic housing. Accessories and Options Standard Insect screen for vent line Bottle for ammonia solution Spare gaskets Tube of thread lubricant Universal wrench Optional Additional Control Modules and Ejectors for Multipoint Application Automatic Changeover System Booster Pumps Chlorine Gas Detector Chlorine Evaporators Chlorine Pressure Reducing Valves Diffusers Flexible Connectors and Manifolds Gas Flow Transmission Integral Residual Controller for Automatic Chlorinators Pressure Gauge Mounted on Vacuum Regulator Switch for Electric-Manual Operation on Automatic Models Vacuum Switches (High and/or Low) Valve Alarm Contacts Installation When the ejector is operating, gas enters the vacuum regulator, being reduced from supply pressure to a constantly regulated vacuum by the throttling action of the gas inlet valve. The gas then passes through the regulator, the flowmeter and the manual or automatic flow control valve into the ejector. Within the ejector, the gas is completely mixed with water or process liquid to form a chemical solution which delivered through solution hose or piping to the point of application.

Location Select a location for installation of the floor cabinet for protecting from unauthorized personnel. The location should be selected to permit easy access to both the front and rear of the cabinet for operation and maintenance procedures. The cabinet is not appropriate for outdoor installation. So locate the dispenser cabinet in indoor isolated from unauthorized personnel. The location should be well ventilated, provided with a source of heat, to maintain a comfortable surrounding temperature and be sufficient size to allow easy access for inspection and maintenance of the dispenser and attendant gas supply system if local regulations do not specify that the gas supply system should be placed in a separate place. Connection Schedule 80 PVC union connections are provided with all AQUS Inc. floor-mounted gas dispensers for the vacuum inlet from the vacuum regulator and vacuum outlet to the ejector. The size of the union is dependant on the capacity of the floor cabinet. Threaded connections should be prepared with PTFE (Teflon) tape in advance of assembly. Ensure that all container velves are closed before connecting! Only use the intended gas lines! The ejector is supplied with a check valve and an drain connection to prevent water from reaching the control module. Ordering information Please specify the following : Flowmeter Capacity (for each meter) Water Supply and Back Pressure (for each ejector) Automatic Changeover (if required) Number of Control Modules with Automatic Control Electrical Characteristics Shipping Weight and Cubage Up to 40kg/hr : -180 lb(82kg), 24.7ft³(0.7m³) Up to 200kg/hr : -225 lb(102kg), 24.7ft³(0.7m³) Operation Water flowing through the ejector creates a partial vacuum which acts on a diaphragm assembly to open the inlet valve admitting gas from the source into the vacuum regulator. A spring-opposed diaphragm regulates the vacuum to a closely controlled valve. At this point the gas flow may or may not be divided to feed chlorine gas to one or more locations. For each application point, the gas passes through a flowmeter to either a manual or an automatically controlled rate valve. The differential across this rate valve is closely controlled by a differential regulating valve. The controlled flow then goes to the ejector where it is thoroughly mixed and dissolved in the water and carried to the application point as a solution. When the flow is divided, multiple control modules and ejectors are used. Each operates independently of the others. Adjustment of one of the gas flow rates has no effect on the other rates. The system is completely under a partial vacuum from the ejector to the gas inlet valve during operation. If the water supply to the ejector is stopped, or the operation vacuum is lost for any other reason, the spring-loaded gas inlet valve immediately closes to isolate the chlorinator from the gas supply. Any gas under pressure which might enter the regulator is vented from the system through the built-in pressure relief valve. If the source of chlorine gas is exhausted, or the gas port plugged, an excess vacuum valve in the control module protects the system from damage.

Dimensions

NA-6F Shilla-Technoville, 39-3, Dang-dong, Gunpo-city, Gyeonggi-do, 435-717, Korea Tel _ +82-31-451-1820 Fax _ +82-31-629-6277 Http://www.aqus.biz