Chlorinator MODEL MK-I

Similar documents
Chlorinator. MODEL C-731 (Floor Mounted)

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Full-Vacuum Chlorinator C 2212 MB / 1

Model 4000 Pressure Controller

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Highest Quality. Gas Chlorination Systems

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

2008 by Controlmatik ABW

Chemical Injection Technologies Installation/Service Bulletin

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Model VR6 System. Installation, Operation & Maintenance

ProMinent Gas Chlorination

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

BULLETIN 901 SAFE RELIABLE ECONOMICAL REGAL GAS CHLORINATORS SULPHONATORS AMMONIATORS

Section GAS CHLORINATION SYSTEM

Variable Area Flow Meters

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

VACCUPERM Vacuum chlorine gas dosing systems

HGC-200 Hydro Gas Chlorinator

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Unit 24: Applications of Pneumatics and Hydraulics

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Vaporizer Piping Liquid Chlorine Manifolds

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

VACUUM REGULATORS CONTENTS

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

GILMONT ACCUCAL FLOWMETERS

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

INSTALLATION OPERATION MAINTENANCE

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Pneumatic dead-weight tester Model CPB3500

Clean Regulator/Fluororesin Type

Manual Actuated Boiler Blowdown Valves

Air Operated Hydraulic Pumping Systems to 50,000 psi

PRO-50 Instrument Supply Regulator

Installation, Operation, and Maintenance Manual

High Precision Gauge Pressure Indicators

OPERATING INSTRUCTIONS

Constant Pressure Inlet (CCN) Operator Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Columbus Instruments

Flow meter. bellow vaporizer. APL valve. Scavenging system

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA CAUTION

User's Manual. MixRite TF 10. Edition 05.08

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

MANUAL GAS MANIFOLDS

TEST SPECIFICATION NYT-909-C

Plant, components and devices for very high and high pressures (7000 bar and over)

[Graphic Division] 10

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

ADAPTABILITY & PRECISION

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Pressure measurement. Pressure gauges

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Series IRV1000/2000/3000

Air Amplifiers & SYSTEMS

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Description Advanced Features Typical Applications

MEDICAL EQUIPMENT CATALOG

WW-730. Pressure Sustaining/Relief Control Valve

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Made of Chloraflon, 5 Years warranty Resists to chlorine chemical attacks

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Glass tube flowmeters Series 2000

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

TECHNICAL DATA. Q= Cv S

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

DS05C,D,G Dial Set Pressure Regulating Valves

Liquid ring vacuum pumps in compact design

Flow Material Length. Weight GPM LPM. Style 3095

MUD 1. Vent check valves. Instruction and maintenance manual.

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Bermad Pressure Reducing. Model: 42T

Actuator HON 670 / 671

ACV-10 Automatic Control Valve

GRAPHIC DIVISION. 3D drawings available at

WIKA INSTRUMENT CORPORATION

VERTICAL BLADDER TANK

Transcription:

Chlorinator MODEL MK-I

The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable for use with chlorine. Sulphur dioxide or ammonia gas. Intermittent Stop-Start. Control or automatic Shut-Off. Can be achieved by interruption of the motive water supply. The Instrument is arranged for wall fixing & incorporates a gas tilter with flush mounted vacuum gauge to indicate the vacuum of the ejector entering the chlorinator a vacuum controller a variable area flow meter with integral control valve: an injector assembly with non-return valve & interchangeable nozzle & throat & a manifold mounted pressure gauge indicating the pressure of the operating water. Design Features CONTROL : The vacuum control system will maintain the capacity selected. ACCURACY : Meters are calibrated to give an accuracy of better than 40% of the maximum indicated gas flow. CALIBRATION : With the modern variable area flow meter incorporated in this instrument substantial linear results are achieved on the calibrated scale. RELIABILITY : The materials chosen for the construction of the instrument have been carefully selected for the duties which they are to perform extensive use has been made of modern plastic materials which are highly resistant to attack by the gases. Where metals have been used advantage has been taken of modern metallurgy techniques to withstand the corrosive action of the gases handled. ACESSIBILITY : Removal of the cabinet shroud exposes all components for easy maintenance. In restricted areas the unique construction of the instrument enables it to be easily lifted its wall fixing & taken to a bench foe overhaul purposes. Removal of the front panel only requires the disconnection of four unions. SAFETY : Due to the nature of the gases metered to this equipment prime consideration has been given to the safety of the operating personnel. The system incorporates a positive shut-off in the event of water failure a pressure relief to avoid gas Build-up & a vacuum relief to cover gas failure or chokage. FLEXIBILITY : The capacity of the instrument can be readily changed by simply removing the existing meter tube & scale & inserting replacements of the desired range. Under some circumstances if may also be necessary to change the injector nozzle & throat combination to suit the new conditions.

MAINTENANCE : The simplicity of design & robustness of all components reduce maintenance to an absolute minimum. Under normal operating conditions an annual examination of the instrument & the renewal of certain joint rings & gaskets is all that would be necessary. DIAGRAM A : Vent to atmosphere Gas inlet connection Vacuum relief valve Solution outlet connection Pressure relief valve Gas filter Gas pressure gauge Meter Water pressure gauge Gas control valve Operating water pressure inlet connector Vacuum controller. Injector & non-return valve assembly Construction CABINET : Two-tone fiber-glass lift-off shroud for easy access. FILTER : Silvered metal with renewable glass wool insert. GAS GAUGE : Bourdon tube with silver ABS / PVC / PTI diaphragm oil filled capsule dual-calibrated. VACUUM CONTROLLER : Plastic ABS / PVC / PTFE chamber & diaphragm with silver inlet & special alloy spring & trim. METER : Variable area design with plastic float & separate scale dual calibrated. CONTROL VALVE : Needle valve of all plastic ABS / PVC / PTFE construction. SAFETY VALVES : Plastic ABS / PVC / PTFE mushroom type valves in plastic housing with special alloy springs. INJECTOR : All plastic ABS / PVC / PTFE body with renewable nozzle & throat incorporating positive non return valve with special alloy spring. WATER GAUGE : Bourdon type dual calibrated.

Principle Of Operation The gas to be metered enters the instrument from the source through a filter unit designed to extract particulate matter could be contained in the gas the pressure of the gas being indicated on a pressure gauge which is coupled into the system. From the filter unit it then passes to a spring loaded diaphragm operated vacuum controller to maintain correct control conditions for accurate and stable metering. Pressure is prevented from being built-up in the system by means of a spring loaded relief valve. The vacuum controller incorporates a valve to shut off the gas supply if the water supply to the injector assembly is interpreted. Should the vacuum created by the injector fall below the requiearad minimum the inlet valve on the regulator will close & thus prevent any further flow of gas. The gas next flows through a variable area direct reading gas flow meter incorporating a needle type control valve. The rate of flow required is set by adjustment of the control valve & is indicated on the direct reading meter he scale of which is dual calibrated & indicates the flow of gas in weight units. The two scales are indicated in pounds & gms/kgs. per hour unit. Calibration covers a range of 10:1. A vacuum breaking valve is incorporated within the system to prevent excessive conditions arising in the event of the gas supply being isolated during times when the injector is left running. The vacuum braking valve together with the pressure relief valve referred to is incorporated in a single assembly from whence connection is made to atmosphere. After the control valve the measured gas is conducted to an aspirator type injector & thus entrained into the water system & discharged as an aqueous solution to the point of application. The injector unit is fitted with a positive acting non-return valve the purpose of which is to prevent water gaining access to the system during non-operational periods when pressure water conditions might exist at the unit. The pressure of the injector operating water supply is indicated on the gauge. The dials of both the gas & water pressure gauges are dual calibrated in both pounds per sq. inch & kilograms per sq. centimeter.

Special Features NO WASTAGE : All operating water required by the instrument is used in converting the gas to the solution. there is no auxiliary make-up water requirement & hence no wastage occurs. NO FLOODING : A spring loaded diaphragm assisted non-return valve forms an integral part of the injector assembly & closes when the injector is subject to static pressure conditions to; prevent water from entering the system. NO HEAT : The design of the vacuum controller is such that no supplementary heating of the instrument or of the gas supply thereto is required. the GAS PRESSURE RELIEF : In the event of excessive gas pressure being developed within the system for any reason it is safely vented to atmosphere. VACUUM RELEASE : A vacuum valve is incorporated within the system which will admit air to satisfy any excessive vacuum which may develop. The air admitted into the system will not pass through the flow meter hence only gas flow will be indicated. DUAL CALIBRATION : Both pressure gauges & the meter scale are calibrated in both English & Metric measurements. AUTOMATIC SHUT-OFF : A vacuum actuated spring loaded positive automatic shut-off valve of extremely robust design is fitted in the vacuum controller. If failure of this valve occurs due to mishandling the gas is safely vented to atmosphere. NO SEALED UNITS : All components can be readily & easily dismantled thus the renewal of a diaphragm would not necessitate replacement of the complete unit.

Techinical Data DIMENSIONS : 18.5 ( 464 mm ) wide 23 ( 588 mm ) length overall depth 10.5 (265 mm) from wall. WEIGHT : 34 lbs approx. ( 15 Kgs. ) MATERIALS : FRP Cabinet & corrosion resistant metals. METERS : (Maximum reading) 0.25 to 10kg/hr METER RATIO : 10:1 for any meter OPERATING WATER SUPPLY : ½, ¾, or 1 dependent upon installation requirements. Maximum allowable pressure 250 lb/sq. in ( 17.5 Kgs./ sq. cm) MAXIMUM BACK PRESSURE : Approximately 100 lb./sq. in. ( 7 kgs./sq. cm. ) SOLUTION DELIVERY : ½, ¾, or 1 dependent upon installation requirements. SAFETY RELIEF : 3/8, o. d. tubing. ELECTRICAL REQUIREMENTS : None apart from special circuits which may be required for automatic control & accessories such as booster pumps etc. ACCESSORIES : Standard accessories, supplied with each chlorinator include cylinder connector valves & tubes (to suit capacity). solution delivery tubing. injection fittings or diffuser at point of application tube clamps complete sec of spares. Also available when required are pressure reducing valves gas manifolds booster pumps change-over valves residual chlorine testing sets & electrically operated valves. GUARANTEE : The apparatus is guaranteed against all inherent manufacturing defects for a period of one year from date of dispatch. This does not apply in the case of mishandling or serious neglect whilst on site hor to it not of our manufacture which are subject to the guarantees in force by the manufacturers.

Ejector MK-I WE RESERVE THE RIGHT TO MAKE DESIGN IMPROVEMENT AND OTHER CHANGES AT ANY TIME WE FEEL IT DESIRABLE TO DO SO.

The ejector creates a vacuum in the system by virtue of water under pressure passing through its venture and opening the check valve. This spring opposed the check valve prevent water entering the vacuum gas pipe work on shut down of the system. The gas entering the ejector under vacuum via the check valve is vigorously mixed with the incoming water flow prior to injection in to the water to be treated. Capacity Maximum back pressure Water inlet connection Solution out let connection Vacuum gas connection 0.5 Kg/Hr to 10 Kg/Hr 10 LBS 1 PVC Union 1 PVC Union 15mm PVC union