Aquor House Hydrant V2

Similar documents
Booster Pump PB4-60 Replacement Kits

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

PRO SINK -R 1 and 2. Dilution system CONTENTS

D05 Pressure Regulating Valves

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

UltRo Dual Flow Reverse Osmosis Water System

Model PSI Compressor with 3-Gallon Air Tank 12VDC

D05T Compact Design Pressure Regulating Valves

User's Manual. MixRite TF 10. Edition 05.08

Combination Air Valve

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Operating Instructions Model and Hydrostatic Test Pump

Model VR6 System. Installation, Operation & Maintenance

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Installation of Your SprayMaster System

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

V43 Pressure Actuated Water Regulating Valve

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Installation Instructions

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

INSERT FITTINGS INSERT FITTINGS

3/8" Dr. Air Butterfly Impact Wrench

MAINTENANCE PROCEDURE FOR X 650

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Direct Operated Precision Regulator Modular Style. Standard Specifications

Natural Gas Conversion Kit

Techcon Systems TS1258 Pressure Pot

INSTALLATION INSTRUCTIONS

DS05C,D,G Dial Set Pressure Regulating Valves

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Installation, Operation and Maintenance Manual for Back Pressure Regulator

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Speed control assembly model A-1

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Anti-flood device Model B-1

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Installation Instructions

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

100C Air Compressor Kit

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

LRS(H)4 Pressure-Reducing Regulator User Manual

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Eaton Filtration, LLC

TECHNICAL DATA. Page 1 of 12

SCUBAPRO. Balanced Power Inflator

TECHNICAL DATA CAUTION

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

2.0 INSTALLATION & SERVICE

Operating Instructions Model and Hydrostatic Test Pump

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

LEAK SEALING SYSTEMS

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

200 PSI COMPRESSORS - MODEL NUMBERS

V-24 OXYGEN LANCE VALVE

RG1200 Service and Repair Manual

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

1.0 - OPENING AND CLOSING THE DOOR

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Halsey Taylor Owners Manual STOP!

VERTICAL BLADDER TANK

Service and Repair Manual

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Assembling & Installing your Pool Cleaner

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Hydrants & Water Pipe

INSTALLATION & MAINTENANCE INSTRUCTION

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

WHEATLEY Series 500 Swing Check Valve

Installation, Operation, and Maintenance Manual

Hydraulic Punch Drivers

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Engineering Excellence. Installation Guide

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

INSTALLATION INSTRUCTIONS

Installation and Use Manual

Installation, Operation, and Maintenance Manual

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

SEries 29 Hydrant valves installation, operation & maintenance manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

1 DRIVE INDUSTRIAL IMPACT WRENCH

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Bermad Pressure Reducing. Model: 42T

Transcription:

Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE

VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock for exterior building walls. Instant Water Access Less than a second to connect. Garden hoses can be quickly engaged under full pressure, hassle-free. Water flow starts instantly. No Leaks, No Maintenance The pressure-closed valve minimizes wear and cannot be overtightened, for an extremely long lifespan even with frequent use. Sub-Zero Freeze Protection Just unplug and go. The stainless steel body provides significantly more freeze protection than traditional brass frost-free sillcocks. Low-Profile Design Sits flush against the wall for a sleek appearance. Saves valuable inches on walkways and tight spaces, and prevents snagging hazards. Marine-Proven Reliability An industrial-use connection system backed with over 15 years of testing and development for harsh marine environments. Heavy-Duty Hose Connector Durable, wear-resistant, and crushproof, the commercial-grade hose connector attaches to any standard garden hose. 100% Lead-Free Stainless Steel Our marine-grade, low-carbon stainless steel is vacuum-cast for maximum strength and durability. Absolutely zero lead is used. High-Performance O-Rings Viton O-rings are renowned for their long lifespans and wear resistance.

VBH-SERIES 1/2 NPT inlet Compatible with any plumbing fitting. Rear valve housing Stainless steel. Unscrew to access O-rings. Debris cover Weather-proof thermoplastic. Hydrant body Marine-grade stainless steel. Wedge backplate 5 angle for drainage. Main outlet Insert hose connector here. Viton O-Rings For a leak-proof seal, every time. Viton O-Rings Zero-maintanence. Replaceable. Vacuum breaker Prevents reverse flow of liquid. ASSE 1019 tested & certified. Check valve One-way water flow. 3/4 Hose Thread Universal garden hose connection. Operating Rod Single moving part. Stainless steel. Optional Accessory: 90 Elbow Inlet Positionable in any direction. Stainless steel. 1/2 NPT.

VBH-SERIES 14 13 15 8 10 1 2 3 4 5 6 7 9 11 12 16 17 18 19 20 21 PART DESCRIPTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Rear Valve Housing (inlet) Valve Spring Hydrant Body O-Ring Inner Valve O-Ring Operating Rod Hydrant Body Vacuum Breaker Washer Vacuum Breaker Valve Vacuum Breaker Seal Vacuum Breaker Retainer Vacuum Breaker Spring Vacuum Breaker Cover Wedge Backplate Debris Cover Nut & Bolt Debris Cover 16. 17. 18. 19. 20. 21. Connector O-Rings Connector Body Check Valve O-Ring Check Valve Check Valve Spring Check Valve Retainer Need parts? Spare and replacement parts are readily available for every product we make. contact@aquorwatersystems.com

VBH-SERIES FREEZELESS OUTDOOR FAUCET SYSTEM MODEL TOTAL LENGTH STEM LENGTH [INCH] [MM] Note: optional 90 elbow inlet reduces length by 1/2 [13mm] TOTAL LENGTH [INCH] VBH-04 4 144 5 11/16 VBH-06 6 194 7 9/16 VBH-08 VBH-10 VBH-12 8 10 12 244 294 344 9 9/16 11 9/16 13 9/16 95 Flush-mounted wall hydrant with twist-lock connection system. Integral vacuum breaker for anti-siphon protection. Allows user to access water instantly by connecting under full water pressure. Robust O-ring connection system ensures a reliable leak-proof seal, even at high water pressures. Stainless steel operating rod and pressure-closed valve provide zero-maintenance reliability for years. Hydrant self-drains upon disconnection to provide freeze protection. Hydrant comes standard with 1/2 female NPT inlet. Rotatable 90 elbow and other inlets available. Each hydrant kit includes polymer hose connector with 3/4 GHT threading. Any 3/4 accessory (eg. water timers, splitters, regulators) can be attached to end of hose connector. Hose connector contains integral check valve for additional backflow protection. Inlet/Outlet: 1/2 NPT, 3/4 GHT Flow rate: 6.8 GPM @ 52 PSI Operating water pressure: 25-125 PSI Operating temperature range: 0-140 F Approvals: ASSE 1019A Warranty: 10-year stainless components, 5-year polymer 1-1/2 2 15/16 [74mm] 3-15/16 [100mm] 4 11/16 [119mm] 1-1/8 Use 1-1/2 and 1-1/8 drill bits for entry hole. Template included in hydrant box. 2 13/16 [72mm] 3 1/8 [79mm]

Installation The Aquor House Hydrant is designed for outdoor use. Install in exterior walls of homes and buildings. A small amount of water self-drains from the outlet upon disconnection. The House Hydrant is for heated and insulated building walls only. The House Hydrant can only offer freeze protection if the ambient temperature around the rear valve is above freezing. If you are installing the hydrant on a surface that isn t flat or smooth, such as stucco, masonry, or lap siding, using a mounting block is highly recommended. Use flashing to protect against water intrusion. A mounting block provides a level, 90 surface that allows the hydrant faceplate to sit tightly against the wall. The hydrant s cover backplate provides a 5 downward tilt for drainage. 95 Use the template (included in hydrant box) to drill the entry hole. 1-1/2 and 1-1/8 bits are recommended. For the mounting holes, make sure to insert the debris cover and wedge behind the hydrant faceplate for accurate markings. You can unscrew the rear inlet from the main hydrant body. Thread in the appropriate 1/2 NPT fitting for your plumbing, wrapped in teflon tape then pipe-joint compound. Re-attach the inlet and tighten. Hand-tight is fine, do not over-torque. The inlet is designed to rotate 360 from full lock for alignment, while still keeping a watertight seal. With the appropriate fitting threaded in, connect the hydrant to your plumbing system. With PEX tubing, we recommend adding an expansion loop inside the wall if possible. This allows the hydrant and fitting to be inspected and serviced from the exterior of the building, if ever needed.

Hose Connector Attach the Aquor hose connector to any garden hose. It can stay attached; there is no need to remove it every use. Before storage, de-pressurize your hose by squeezing the nozzle on the other end. Use any accessory as you would with a traditional bibb. Inline ball valves, timers, splitters, vacuum breakers, and etc. can be attached to the connector. Aquor Hose Connector Ball Valve (optional) Garden Hose Operation To engage, line up the three helical grooves on the hose connector (marked with an arrow) with the three nibs on the hydrant faceplate. Simultaneously push and twist the connector clockwise in a smooth motion. Water flow will start instantly when the connector is engaged. To disconnect, push the connector in slightly, then untwist counter-clockwise. The hydrant will self-drain any remaining water left in the body and vacuum breaker assembly. Remember to de-pressurize your hose before storage. Nibs on hydrant faceplate Grooves on hose connector Bayonet locking design keeps connector secure when engaged Water flow: In Water flow: Out

Care & Maintenance It s best to disconnect the hydrant when not in use. The hydrant can only offer freeze protection when disconnected. We recommend unplugging after each use. If you leave the Aquor connector attached to your garden hose, make sure to de-pressurize the hose after use. Temperature changes can cause water inside to expand, causing excessive pressure on the connector s inernal check valve (and your nozzle or accessories) over time. Storing your hose connectors out of the elements can prolong their lifespan. You can drain your hose and bring it inside - the internal check valve prevents any unwanted draining afterwards, so your floor stays dry. Protect the hose connector s O-rings. They are designed for extremely long lifespans if used properly. Use care not to snag the connector O-rings on the hydrant nibs. When connecting, line up the grooves before attempting to push or twist. Routine cleaning with soap and water is usually sufficient to maintain the corrosion resistance and appearance of the marine-grade stainless steel. Use a soft brush to remove any accumulated dirt, then rinse with clean water. Use stainless steel polish as needed. If you have hard water buildup, the hydrant can be completely disassembled for service or cleaning if needed. The inner valve and stem are accessed through the rear. Adding a service loop of PEX during installation makes this easy in the future. Troubleshooting No water flow when connected. Check to make sure water supply is live to the hydrant. If water supply is active, the connector s internal check valve may be stuck. It can be accessed through the threaded end of connector. Or, insert a long screwdriver into the front end and firmly tap down. Water leaking from hydrant inlet. If leaking from the plumbing connection, ensure a proper 1/2 NPT fitting was used. Use 4-5 wraps of teflon tape, followed by a layer of pipe-joint compound. Correct order of check valve assembly Water leaking from hydrant body. Inspect the O-ring between the rear valve housing (threaded inlet) and hydrant main body. The rear valve housing does not need to be firmly tightened; it should remain leak-free up to a full revolution from lock. Water leaking from vacuum breaker. Unscrew the colored vacuum breaker cap, then test hydrant. If the leak stops with cap removed, the inner spring may be too heavy for the water pressure. If the leak continues, disconnect and unscrew the white polymer retainer. Ensure all vacuum breaker parts are present and in the correct order as shown below. Water leaking from hydrant outlet. If leaking while disconnected, unscrew the rear valve housing, check for debris, and inspect inner valve O-ring for damage. If leaking while connected, inspect both hose connector O-rings for damage. Water sprays from vacuum breaker when connecting. Unscrew vacuum breaker cap and test again. The inner spring may be too heavy for the water pressure. If the issue persists, inspect the vacuum breaker washer and replace if needed. Hose connector won t stay plugged in. The hydrant uses water pressure to seal, and is designed for pressures of 25-125 psi. If you are installing the hydrant on a well or low-pressure system, contact us for a higher weight internal spring. Hose connector won t unplug. If the hose connector seems stuck or requires too much effort to unplug, there may be pressure or suction holding it in. Try squeezing your hose nozzle while disconnecting. If the issue occurs gradually, try cleaning the hydrant outlet and lubricating O-rings with petroleum jelly. Correct order of vacuum breaker assembly Support & Warranty We stand behind every product we make. Our mission is to manufacture the highest-quality water connectors possible, and our products are engineered to last years of frequent use. Aquor offers a 10 year warranty on all stainless steel components, and 5 years on all polymer components. For more information, contact us or visit our website at www.aquorwatersystems.com.

SUBMITTAL SHEET ENGINEERING SPECIFICATION: Aquor Water Systems "House Hydrant V2" automatic draining wall hydrant with integrated vacuum breaker. Complete with nonfreeze integral backflow preventer, stainless steel body and faceplate, stainless steel operating rod with pressure-closed valve, thermoplastic or stainless debris cover, and 1/2" female elbow or straight inlet. Each unit furnished with 3/4 male polymer hose connector. Hydrant: MODEL STEM LENGTH TOTAL LENGTH TOTAL LENGTH [INCH] [MM] [INCH] VBH-04 4 144 5 11/16 VBH-06 6 194 7 9/16 VBH-08 VBH-10 VBH-12 8 10 12 244 294 344 9 9/16 11 9/16 13 9/16 Note: optional 90 elbow inlet reduces total length by 1/2 [13mm] 95 Inlet: 1/2 NPT Straight Inlet (standard) 1/2 NPT 90 Elbow Inlet (optional) Cover Finish: Aquor Blue (standard) Slate Gray (standard) Brushed Stainless Steel (optional) 4 11/16 [119mm] 3-15/16 [100mm] Connectors: 3 1/8 [79mm] 2 13/16 [72mm] Straight Hose Connector (standard) Angled Connector (optional) Removable Faucet (optional)