Presented to the IAPMO Standards Review Committee on March 7, 2016

Similar documents
ASSE International Product (Seal) Listing Program

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

ASSE International Product (Seal) Listing Program

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

An Urgent Bulletin from CSA Group

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G96 Series BASOTROL Dual Operator Valve

Dual Solenoid Gas Valve Installation

Scald Protection Three-Way Thermostatic Mixing Valve

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Smart Water Application Technologies (SWAT) TM

Operator: Save these instructions for future use!

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

36H SERIES Combination Gas Valve

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Water Pressure Reducing Valves

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Scald Protection 3-Way Thermostatic Mixing Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

CASH VALVE TYPE KP BACK PRESSURE VALVES

SIZING OF WATER PIPING SYSTEM

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

SIZING OF WATER PIPING SYSTEM

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

Pressure Independent Control Series

Installation and commissioning instructions 255 series and 256 series

Gas Injection Systems

American Society of Sanitary Engineering

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

TECHNICAL INSTRUCTIONS

DS05C,D,G Dial Set Pressure Regulating Valves

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Model: 43T. Bermad Pressure Relief Valve

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

1 Exam Prep. Tabs and Highlights

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

Operator: Save these instructions for future use!

GM Series Dual-Block Multi-Function Gas Control Valves

LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE

Installation/Care/Use Manual

Operator: Save these instructions for future use!

G92 Series BASOTROL Automatic Pilot Gas Valve

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Leak free Pipe Rupture Valve for Excavators

Residential Pressure Booster Systems

D05 Pressure Regulating Valves

Operator: Save these instructions for future use!

Automatic Valve Proving Control

DS06D,G Dial Set Pressure Regulating Valve

Operator: Save these instructions for future use!

SINGER MODEL 106/206-RPS-L&H

National Health Service Model engineering Specification

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

GM-7000 Series CE Approved Gas Control Valve

SCA Series Inverted Bucket Steam Traps

Installation and Use Manual

Air Amplifiers & SYSTEMS

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Type 3 - PSA Nitrogen Generation System

MyControl Bathing System Signature Series

INSTALLATION GUIDE Gas Rangetops

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Water Temperature Control - Groups of Fixtures

Operation and Maintenance of the EPV200 Portable Ventilator

SECTION BUTTERFLY VALVES

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

ELKHART BRASS MANUFACTURING COMPANY

553 Series.

Transcription:

Summary of Substantive Changes between the 2015 edition of ASSE 1070/ASME A112.1070/CSA B125.70, Water Temperature Limiting Devices, the 2004 edition of ASSE 1070, Water Temperature Limiting Devices, and the 2012 edition of CSA B125.3, Plumbing fittings Presented to the IAPMO Standards Review Committee on March 7, 2016 General: The new standard ASSE 1070/ASME A112.1070/CSA B125.70 is a joint harmonization between ASSE 1070-2004 and sections of CSA B125.3-2012. The changes between the previous editions and this current edition will affect currently listed products. Although the majority of previous ASSE 1070 and CSA B125.3 tests and requirements have been reformatted (which does not allow direct correlation of sections), the current version now includes joint connections (compression, push-fit, solder, threaded), toxicity requirements (to NSF 61 & 372, if applicable), electrical requirements, slightly modified testing requirements, and additional marking requirements as summarized below. and CSA B125.3-12 2015 Section 1.1, Scope states devices not designed to address thermal shock (only in editorial Foreword section in but cited in section 4.12.2 in CSA 1.1 This Standard covers water temperature limiting devices intended to limit the hot or tempered water temperature supplied to fittings for fixtures such as sinks, bidets, lavatories, and bathtubs to reduce the risk of scalding. These devices are not designed to address thermal shock., 1.1 Application Water Temperature Limiting Devices (herein referred to as the device ) shall control and limit the water temperature to fittings for fixtures such as sinks, lavatories or bathtubs and are intended to reduce the risk of scalding. and CSA B125.3-12 2015 Section 3.1.1, Working pressure now up to 125psi (working pressure not defined in CSA Devices shall be designed to function at a supply pressure range of 140 to 860 kpa (20 to 125 psi)., 1.2.3 Working Pressure The device shall be designed to function at a maximum working pressure of not less than 125.0 psi (861.8 kpa). New 2015 Section 3.2 cites solder joints (nonexistent in but cited in section 4.5 in CSA 3.2 Solder joints, The dimensions of solder joint ends for connection to copper tubes or fittings (other than factory-assembled parts) shall comply with ASME B16.18 or ASME B16.22, as applicable. Page 1

New 2015 Section 3.3 cites threaded joints (nonexistent in but cited in section 4.6 in CSA 3.3 Threads, Pipe threads shall comply with ASME B1.20.1 and hose threads shall comply with ASME B1.20.7. New 2015 Section 3.4 cites compression joints (nonexistent in but cited in section 4.7 in CSA 3.4 Flared and ball sleeve (compression) tube fittings, The screw thread dimensions of flared and ball sleeve (compression) tube fittings shall comply with ASME B1.1. New 2015 Section 3.5 cites push-fit joints (nonexistent in but cited in section 4.20 in CSA 3.5 Push-fit fittings, Connections achieved by push-fit fittings shall comply with ASSE 1061. New 2015 Sections 3.8.1 & 3.8.3 added that require NSF 61 & NSF 372 compliance for devices intended to convey or dispense water for human consumption (already in in section 4.15 of CSA 3.8.1: Devices covered by this Standard and that are in contact with drinking water intended for human ingestion shall comply with the applicable requirements of NSF/ANSI 61. 3.8.3: Fittings intended to convey or dispense water for human consumption through drinking or cooking shall not contain a weighted average lead content in excess of 0.25% when evaluated in accordance with NSF/ANSI 372. New 2015 Section 3.9 for devices incorporating electrical features (already in section 4.17 of CSA 3.9 Devices incorporating electrical features 3.9.1 Electrical power to low-voltage circuits involving a peak open-circuit potential of not more than 42.2 V shall be supplied by a (a) primary battery supply; (b) suitable Class 2 low-voltage transformer complying with the applicable CSA or UL electrical Standards; or (c) combination of a transformer and fixed impedance that, as a unit, complies with the requirements for a Class 2 transformer specified in Item (b). 3.9.2 Devices incorporating electrical features other than low-voltage circuits shall comply with the applicable CSA or UL electrical Standards. 3.9.3 Electrical plumbing controls, including solenoid valves, shall (a) be considered components of the device; (b) be tested with the device; and (c) comply with Clause 4.5. Replacement of a battery during the life cycle testing specified in Clause 4.5 shall not be considered a failure. Page 2

2015 Section 4.3.5.2 added different pressure and temperature tests to device s seals (already in in section 5.3.1.1 of CSA 4.3.5 Test temperatures and pressures 4.3.5.1 The test shall be conducted in an ambient environment of 20 ± 5 C (68 ± 9 F). The specimen shall be brought to equilibrium test temperatures by running water through it. 4.3.5.2 The test pressures and temperatures shall be as follows: (a) 140 ± 14 kpa and 10 ± 6 C (20 ± 2 psi and 50 ± 10 F); (b) 860 ± 14 kpa and 10 ± 6 C (125 ± 2 psi and 50 ± 10 F); (c) 140 ± 14 kpa and 66 ± 6 C (20 ± 2 psi and 150 ± 10 F); and (d) 860 ± 14 kpa and 66 ± 6 C (125 ± 2 psi and 150 ± 10 F). 4.3.6 Failure criteria Seals of water temperature limiting devices shall not leak., 3.2.1 Purpose The purpose of this test is to determine if the device can withstand a pressure of 125.0 psi (861.9 kpa) without damage or impairment of its performance capabilities. 3.2.2 Procedure Subject the device to a water pressure of 125.0 psi ± 1.0 psi (861.9 kpa ± 6.9 kpa) for five (5) minutes with the outlet blocked. In addition, for devices with seating members apply a water pressure of 125.0 psi ± 1.0 psi (861.9 kpa ± 6.9 kpa) to the inlets of the device for five (5) minutes with the seating member (excluding service stops) closed and the outlet open to atmosphere. 3.2.3 Criteria Any indication of leakage, damage or distortion shall result in a rejection of the device. and CSA B125.3-12 2015 Section 4.4 increased cross-flow inlet test pressure from 5 psi (in both and CSA B125.3-12) to 35 psi: 4.4 Cross-flow test 4.4.1 Purpose The purpose of this test is to determine if cross-flow leakage occurs when the outlet(s) is blocked. Note: When a water temperature limiting device is integral to a plumbing supply fitting, the test is conducted in accordance with the requirement of ASME A112.18.1/CSA B125.1. 4.4.2 Procedures The cross flow test shall be conducted as follows: (a) Install the device in the open position with the mixed water outlet blocked. (b) Pressurize the cold water inlet(s) to 35 ± 7 kpa (5 ± 1 psi) water. (c) Maintain for 1 min. (d) Examine for leakage at the hot inlet(s). (e) Pressurize the hot water inlet(s) to 35 ± 7 kpa (5 ± 1 psi) water. (f) Maintain for 1 min. (g) Examine for leakage at the cold inlet(s). 4.4.3 Failure criteria The rate of leakage shall not exceed 50 ml/min (0.01 gpm). Page 3

, 4.4 Cross-flow test 4.4.1 Purpose The purpose of this test is to determine if cross-flow leakage occurs when the outlet(s) is blocked. Note: When a water temperature limiting device is integral to a plumbing supply fitting, the test is conducted in accordance with the requirement of ASME A112.18.1/CSA B125.1. 4.4.2 Procedures The cross flow test shall be conducted as follows: (a) Install the device in the open position with the mixed water outlet blocked. (b) Pressurize the cold water inlet(s) to 35 ± 7 kpa (5 ± 1 psi) water. (c) Maintain for 1 min. (d) Examine for leakage at the hot inlet(s). (e) Pressurize the hot water inlet(s) to 35 ± 7 kpa (5 ± 1 psi) water. (f) Maintain for 1 min. (g) Examine for leakage at the cold inlet(s). 4.4.3 Failure criteria The rate of leakage shall not exceed 50 ml/min (0.01 gpm). CSA B125.3-12, 5.3.3 Cross-flow check valves Cross-flow check valves shall not leak more than 35 ml/min (0.01 gpm) out of one supply inlet when the opposite supply inlet is pressurized to 35 kpa (5 psi) with water at 10 ± 6 C (50 ± 10 F) for 1 min and with the primary shut-off valves open and all outlets blocked. This requirement shall be met before and after the applicable life cycle test specified in Clause 5.8. and CSA B125.3-12 2015 Section 4.5.2, Life Cycle Test cold water inlet temperature specified is 50 F (but ambient temperature in and 80 F in CSA 4.5.2 Procedure The life cycle test shall be conducted as follows: (a) Supply water to the specimen at a flowing pressure of 345 ± 35 kpa (50 ± 5 psi) and a supply pressure of 550 kpa (80 psi) maximum (valve closed) shall be supplied to the specimen throughout the test, and at (i) 10 ± 3 C (50 ± 5 F) to the cold-water inlet; and (ii) 60 ± 3 C (140 ± 5 F) to the hot-water inlet. (b) Set the discharge flow rate at the manufacturer s minimum rated flow; or in the case of integrated fittings with outlet flow control, the flow shall be set at maximum. (c) Open the hot- and cold-water valves. (d) Set the specimen to discharge water at 40 ± 3 C (105 ± 5 F). (e) Cycle the specimen for 100,000 cycles at a rate of 3 to 5 cycles per minute. Each cycle shall be as follows: (i) Flow water for at least 6 s. (ii) Reduce the hot water temperature to ambient temperature for at least 6 s. (iii) Increase the hot water temperature to 60 ± 3 C (140 ± 5 F). Page 4

, 3.3.2 Procedure, The device shall be cycle tested as follows: a) Cold water at ambient temperatures shall be supplied to the cold water inlet and hot water at 140.0 F ± 5.0 F (60.0 C ± 2.8 C) shall be supplied to the hot water inlet. During this test, maintain the cold and hot water inlet pressures at 45.0 psi ± 1.0 psi (310.2 kpa ± 6.9 kpa). The discharge flow rate shall be set at the manufacturer s minimum recommended flow. With the hot and cold water supply valves open, and the device set to discharge water at 105.0 F ± 5.0 F (40.6 C ± 2.8 C), flow for a minimum of six (6) seconds; reduce the hot water temperature to ambient temperature for a minimum of six (6) seconds. Increase the hot water temperature to 140.0 F± 5.0 F (60.0 C ± 2.8 C). This constitutes one cycle. b) The device shall be cycled at a rate of 3-5 cycles per minute for a total of 100,000 cycles. CSA B125.3-12, 5.8.5.2 Test procedure, The life cycle test for automatic compensating valves shall be conducted as follows: (a) Install the specimen as shown in Figure 4. (b) Adjust the incoming water supplies so that (i) temperature T1 at Valve V1 is maintained at a minimum of 60 C (140 F); (ii) temperature T2 at Valves V1 and V2 is maintained at a maximum of 27 C (80 F); (iii) flowing pressure P1 at Valves V1 and V2 is maintained at 345 ± 35 kpa (50 ± 5 psi); and (iv) flowing pressure P2 at Valves V1 and V2 is maintained at 172 ± 35 kpa (25 ± 5 psi). (c) Adjust incoming inlet supply A to a minimum temperature of 60 C (140 F) and a flowing pressure of 345 ± 35 kpa (50 ± 5 psi) and maintain these conditions. Adjust incoming inlet supply C to a maximum temperature of 27 C (80 F) and a flowing pressure of 345 ± 35 kpa (50 ± 5 psi) and maintain these conditions. Then adjust the outlet temperature to 40.6 ± 3.0 C (105 ± 5.0 F) and set the device to a minimum flow rate of 4.5 L/min (1.2 gpm). (d) Test the control mechanism(s) for the number of cycles specified in Table 4 of the control dial, as follows: (i) for specimens without a separate volume control, turn the temperature control dial at a constant rate of 5 to 20 cycles/min through its full operating range; or (ii) for specimens with a separate volume control, open the volume control, cycle the temperature control dial at a constant rate of 5 to 20 cycles/min through its full operating range, simulating the intended operating motion of the valve without making contact with the end steps, except as agreed to with the manufacturer, and close the volume control. (e) Test the pressure, temperature, or temperature and pressure sensing mechanism(s) for the number of cycles specified in Table 4, with the water flowing through the specimen in the following sequence: (i) inlet supply A and inlet supply D for 4 s; and (ii) inlet supply B and inlet supply C for 4 s. One cycle shall consist of the steps described in Items (i) and (ii). and CSA B125.3-12 2015 Section 4.6.3, Pressure and temperature variation test outlet temperature cannot exceed 120 F (up to 120 F in ; such temperature not defined in CSA 4.6.3 Failure criteria After the initial 5 s following an outlet water temperature change at sensor T3, the outlet water temperature shall not exceed 49 C (120 F) at any time. Page 5

, 3.5.3 Criteria Failure of the device to maintain an outlet water temperature of less than 120.0 F (48.9 C) at all times shall result in the rejection of the device. Failure of the device to maintain the outlet water temperature to within ± 7.0 F (± 3.9 C) from the point of recording the temperature for that step, for each of the 4 steps of Part A of the test, shall result in the rejection of the device. 2015 Section 5.3 Added packaging marking requirement for Mftr s name and model number (nonexistent in but already in in section 6.6.1 of CSA 5.3 Packaging Packaging shall be marked with (a) the manufacturer s name, trademark, or other mark; or (b) in the case of private labeling, the name, trademark, or other mark of the customer for whom the water temperature limiting device was manufactured; and (c) the model number. 2015 Section 5.6 Added outlet temperature marking requirement in mftr s literature if maximum outlet temperature less than 120 F from device (nonexistent in but already in in section 6.8 of CSA 5.6 Water temperature When the maximum water temperature specified by the manufacturer is less than 49 C (120.0 F) at the outlet of the device, the lower temperature shall be stated in the manufacturer s literature. Page 6