Paper Number ABSTRACT

Similar documents
SAFETY ENHANCED INNOVATIONS FOR OLDER ROAD USERS. EUROPEAN COMMISSION EIGHTH FRAMEWORK PROGRAMME HORIZON 2020 GA No

Update on UMTRI Work to Compare PMHS and WorldSID Midsize Male Lateral Impact Responses

Latest FE Model Development of THOR-50M Crash Test Dummy

Humanetics Innovative Solutions, Inc. Hybrid-III 3 Year-Old Child Dummy H FMVSS 208, 213, 49CFR Part 572, Subpart P

Biofidelity Assessment of the 6-Year-Old ATDs in Side Impact

Dix 1 COMPARISON OF THE HARMONIZED HYBRID III 5 TH FEMALE DUMMY CHEST RESPONSE TO THE FTSS AND DENTON DUMMIES

WorldSID 50th vs. ES-2. A Comparison Based on Simulations.

SURFACE VEHICLE INFORMATION REPORT

Q10 dummy in Lateral Impact Report

Test Equipment for H3-95th Dummy

THE NEED TO CONTROL BELT ROUTING FOR SILVER NCAP RATINGS

WorldSID 5% Dummy Model Development in Cooperation with German Automotive Industry

EUROPEAN NEW CAR ASSESSMENT PROGRAMME (Euro NCAP) SLED TEST PROCEDURE FOR ASSESSING KNEE IMPACT AREAS

Crawford 1 BIOFIDELITY EVALUATION OF THE WORLDSID 5 TH ATD FITTED WITH A MODIFICATION KIT PERCENTILE FEMALE SIDE IMPACT

Improving Spine Biofidelity of HYBRID-III 6-Year-Old ATD

EVALUATION OF THE THORACIC DEFLECTION MEASUREMENT SYSTEM RIBEYE IN THE HYBRID III 50% IN FRONTAL SLED TESTS

UN Frontal Impact Requirements

Side impact shoulder for the Q10 dummy design and evaluation

Humanetics Innovative Solutions, Inc. Q0 Child Dummy (6 week old, Newborn) Parts Catalog

CALIBRATION AND VERIFICATION OF DETAILED HYBRID III 50 TH PERCENTILE MALE ANTHROPOMORPHIC TEST DEVICE (ATD) BASED ON EXTENSIVE MINE BLAST TESTS

Occupant restraint optimisation in frontal crash to mitigate the risk of submarining in out of position situation

World Forum for Harmonization of Vehicle Regulations (WP.29)

Paper Number Other relevant changes in 2011 NCAP included:

THE NEED TO CONTROL BELT ROUTING FOR SILVER NCAP RATINGS

SIDE IMPACT INJURY PREDICTION WITH FE SIMULATIONS OF THE NEW ADVANCED WORLD SID FE DUMMY MODELS

Restraint Systems for Infants with Special Needs

MADYMO human models for Euro NCAP pedestrian safety assessment

GTR FlexPLI Manual. FlexPLI Preparation before Car Testing

Fahrzeugsicherheit Berlin e.v. Protection of Children in Cars

Development and Evaluation of EUROSID-2 (ES-2) Dummy

Development and Validation of a 95 th Percentile Male Pedestrian Finite Element Model

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women

A Numerical Investigation of Human Biomechanical Response under Vertical Loading Using Dummy and Human Finite Element Models

Guidelines for Using the UMTRI ATD Positioning Procedure for ATD and Seat Positioning (Version III) December 2003

Protection against Impact with the Ground Using Wearable Airbags

CRASH SIMULATIONS OF THREE WHEELED SCOOTER TAXI (TST)

Jochen Feese 1. Taking Corporate Social Responsibility SAFE ROADS in India and China. Jochen Feese DAIMLER AG Germany

Sensitivity of the Q Series Abdominal Pressure Twin Sensors to Loading Type and Position in Dynamic Restraint System Loading Tests

Guidelines for Using the UMTRI ATD Positioning Procedure for ATD and Seat Positioning (Version V)

VEHICLE DESIGN. and PEDESTRIAN SAFETY. Pedestrian Safety and Car Design. Environment Causes of Accidents. Main Characteristics of Pedestrian Accidents

Qian Wang, Tanya Kapoor, William Altenhof University of Windsor Department of Mechanical Automotive and Materials Engineering

Dynamic Response of the Dummy in Case of Child Cyclist Collision with Passenger Car

Study of the Kinematics of the THOR dummy in Nearside Oblique Impacts

2014 QUICK FACTS ILLINOIS CRASH INFORMATION. Illinois Emergency Medical Services for Children February 2016 Edition

2012 QUICK FACTS ILLINOIS CRASH INFORMATION. Illinois Emergency Medical Services for Children September 2014 Edition

Examination of Human Body Mass Influence on Pedestrian Pelvis Injury Prediction Using a Human FE Model

Injury Patterns of Korea Pedestrian Accidents in KIDAS

I. INTRODUCTION. A. Background of the study

ESTIMATION OF THE EFFECT OF AUTONOMOUS EMERGENCY BRAKING SYSTEMS FOR PEDESTRIANS ON REDUCTION IN THE NUMBER OF PEDESTRIAN VICTIMS

Table 1: Child Seat Classifications

Partners for Child Passenger Safety Fact and Trend Report October 2006

Analysis of Backward Falls Caused by Accelerated Floor Movements Using a Dummy

ATM Analysis: "Coordinating Flexors and Extensors"

Restraint Systems for Disabled Persons

EUROPEAN NEW CAR ASSESSMENT PROGRAMME (Euro NCAP) SLED TEST PROCEDURE FOR ASSESSING KNEE IMPACT AREAS. For 2020 implementation

R J Tunbridge and J T Everest Transport and Road Research Laboratory CROWTHORNE, England

A Study on Injuries and Kinematics in Pedestrian Accidents involved Minivan and Sedan

Tadasana Variation 7. Thighs back, buttocks in (with two helpers)

Effect of Pedestrian Buck Contact Area and Force-Deflection Property on Pedestrian Pelvis and Lower Limb Injuries

Civil Aircraft Side-Facing Seat Research Summary

Development of Practical and Simplified Human Whole Body FEM Model

Study on fatal accidents in Toyota city aimed at zero traffic fatality

Q6 Dummy Thoracic Response and Diagonal Belt Interactions: Observations based on Dummy Testing and Human and Dummy Simulations

The Influence of Heavy Truck Egress Tactics on Ground Reaction Force

EMS professionals face many risks exposure to infectious diseases, violence, hazardous scenes, and oncoming traffic, to name a few.

R Cookson, R Cuerden, D Richards, J Manning TRL, UK. Keywords: Pedestrians, injuries, accident investigations, bumpers, windshields

Guidelines for Using the UMTRI ATD Positioning Procedure for ATD and Seat Positioning

CORRELATION OF DIFFERENT IMPACT CONDITIONS TO THE INJURY SEVERITY OF PEDESTRIANS IN REAL WORLD ACCIDENTS

McIntosh 1 CHILD RESTRAINTS FOR CHILDREN WITH ADDITIONAL NEEDS

Biomechanical Analysis of a Sprint Start. Anna Reponen JD Welch

IRC IRCOBI Conference 2016

Department of Transportation

Millennial Walker A multi-functional, elderly assistance walker with improved posture, comfort, and folding capabilities.

MODELING THE SEAT BELT TO SHOULDER-COMPLEX INTERACTION IN FAR-SIDE CRASHES

Head Impact Analysis Validation for Aluminium Bonnet

Reconstructing a rollover includes examining physical evidence on the roadway and the vehicle. Here s a detailed roadmap to examining that evidence

Priorities for Bicyclist Protection in Car Impacts a Real life Study of Severe Injuries and Car Sources. Rikard Fredriksson 1, Erik Rosén 2

Cambridgeshire and Peterborough Road Safety Partnership Handbook

Assessments SIMPLY GAIT. Posture and Gait. Observing Posture and Gait. Postural Assessment. Postural Assessment 6/28/2016

Child Passenger Kinematics in Emergency Manoeuvres

DOT HS September Crash Factors in Intersection-Related Crashes: An On-Scene Perspective

VRU-to-Truck Collision Compatibility. Master s thesis in Automotive Engineering. Jieer Cao, Zhetong Mo

Alberta. Traffic Collision Statistics. Office of Traffic Safety Transportation Services Division May 2017

U.S. Department Of Transportation

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

Belted driver protection in frontal impact - what has been achieved and where do future priorities lie?

Analysis of Gait Characteristics Changes in Normal Walking and Fast Walking Of the Elderly People

Table of Contents. Pre-Pointe A Year Long Training Guide Page 2

DEVELOPMENT OF A PEDESTRIAN LOWER EXTREMITY PROTECTION CAR USING A BIOFIDELIC FLEXIBLE PEDESTRIAN LEGFORM IMPACTOR

HYBRID III DUMMY NECK RESPONSE TO AIR BAG LOADING. Venkatesh Agaram, Jian Kang, Guy Nusholtz and Gregory Kostyniuk DaimlerChrysler USA Paper No.

Total out of 9 : Legs perpendicular to the floor Stomach, chest and face touching legs Hands palm up, behind legs (barracuda set- up)

The advantages of the Impact NecksGen unit

In-Depth Investigation of Vehicle Traffic Injuries in Changsha of China 1

Neuromuscular Reflexes

Om Fairy LLC Page 1 This personal yoga practice was created for One Stressed Out Yogi.

Data Analysis February to March Identified safety needs from reported collisions and existing travel patterns.

Comparison of Anthropomorphic Test Dummies with a Pediatric Cadaver Restrained by a Three-point Belt in Frontal Sled Tests

OPTIMIZING OCCUPANT RESTRAINT SYSTEMS FOR TACTICAL VEHICLES IN FRONTAL CRASHES

Ab Plank with Straight Leg Raise

2015 Victorian Road Trauma. Analysis of Fatalities and Serious Injuries. Updated 5 May Page 1 of 28. Commercial in Confidence

Transcription:

THE INTRODUCTION OF A NEW ELDERLY ANTHROPOMORPHIC TEST DEVICE (EATD) Michael, Beebe Ime, Ubom Tom, Vara Mark, Burleigh (Great Britain) Joe, McCarthy Humanetics Innovative Solutions United States Paper Number 17-0091 ABSTRACT This technical paper will discuss the development of the new Elderly ATD. This ATD was developed to represent a population with increased vulnerability to injury. The Elderly ATD will provide vehicle manufactures with new tools to evaluate future designs and provide insight on ways to enhance safety measures for their products. Beebe 1

INTRODUCTION The Center for Disease Control and Prevention (CDC) stated that in 2012, there were approximately 36 million drivers 65 or older in the United States. They reported an average of 586 older adults are injured every day in crashes. [1] Drivers 65 and older are expected to be one fifth of all drivers by 2030. The prevalence of medical impairments, including cognitive deficits, rises with age, along with decreased strength of bones and internal organs, which may increase both susceptibility to injury in crashes and driving errors that lead to crashes. [2] Anthropomorphic Test Devices (ATD) are designed to simulate the weight, proportion and kinematics of the human body. Equipped with instrumentation, an ATD provides real time feedback used to assess the design of vehicle safety measures and evaluate injury occurrences in the occupant(s). The question that will be addressed in this study is what type of ATD should represent elderly people and what type of additional injury measures are needed as compared to current ATD s. Humanetics enlisted the International Center of Automotive Medicine (ICAM), Injury Biomechanics Research Center of the Ohio State University (IBRC), University of Michigan Transportation Research Institute (UMTRI) and the SENIORS (Safety ENhancing Innovations for Older Road users) project in Europe (http://www.seniorsproject.eu/) to determine the answer to the question. The anthropometry requirements for the Elderly ATD was determined by ICAM s database to be 70 years old, female, and weighing approximately 73 kg with a stature of 1.61 meters. This represents individuals who are most likely to be injured. The UMTRI statistical body model was used in establishing the external shape of the ATD, while the inside organ shapes and positions from the ICAM s magnetic resonance imaging (MRI) scans provided guidance with the design of the internal organ shapes and positions. The experience designing and testing the Obese ATD [3] was also used to review kinematic and flesh stiffness requirements for this new ATD. The prototype ATD was developed with advanced 3D modeling and cutting edge 3D printing techniques and materials. Utilizing the latest methods of manufacture and materials available permitted new freedoms of design for flesh, organs, ribs, etc. This greatly reduced the amount of time required to manufacture and develop parts; giving flexibility for updates while reducing the need to make and change standard manufacturing tooling. PMHS match pair testing, sled testing, and certification type testing will be conducted to determine the performance of the ATD, while also investigating durability, repeatability and reproducibility of this new process of ATD development. The technology utilized in the Elderly ATD can be applied to further prototyping as well as providing insights for future ATD development. Design Overview The Elderly ATD was designed using the anthropometric data developed by International Center of Automotive Medicine (ICAM) and University of Michigan Transportation Research Institute (UMTRI). Figure 1 shows the first Elderly ATD prototype. Figure 1. Elderly ATD The current prototype utilizes the head and neck from the WorldSID Small Female, and lower arms, hands, knee and feet from the Hybrid III Small Female. The remainder of the ATD, including the flesh, are newly designed to meet the requirements for the Elderly ATD anthropometry. This paper will examine the design of the new Elderly ATD, the Anthropometry used, segment detail, preliminary components, and sled testing. Anthropometry Targets Overall Size and Weight Targets The anthropometry for the elderly was developed by two sources, ICAM and UMTRI. The first step was to develop the size required for an Elderly ATD based on the ICAM motor vehicle database as well as the University of Michigan Adult Trauma Registry. ICAM personnel statistically analyzed data for clarifying the target of an elderly model. They found 80 females whose ages are from 67 to 73 with a mean height of 1.61 meters and with a mean weight of 72.8 kg. From the ICAM/CIREN population the numbers turn out to be (see Table 1): Beebe 2

Table 1. ICAM/CIREN Population Summary N Avg. age Avg. Ht (cm) Avg. Wt (kg) Avg. BMI 30 69.8 159.6 75.9 29.5 From the Annual Estimates of the Resident Population by Single Year of Age and Sex for the United States: 2015 Population Estimates from the U.S. Census Bureau, the 50 percentage female was around 70 years old (see Table 2). Table 2. Annual Estimates of the Resident Population by Single Year of Age and Sex for the United States: 2015 Population Estimates (U.S. Census Bureau) Figure 2 Results from the UMTRI SBSM Combining MRI Scans and UMTRI Shape From ICAM, the MRI scans were provided for this size of person to determine rib cage shape, organ size and placement, and flesh thickness. The scan was overlaid with the body shape to determine how to combine both sets of data into one ATD (Figure 3). Based on the results of these reviews of the databases it was decided that the target values for the new ATD would be a 70 year old Female with a 1.61 meter stature, 73 kg total weight, and a Body Mass Index (BMI) of aproximately 28. External Shape Once the overall size and weight was established, the next step was to determine the shape of the ATD by using the UMTRI Statistical Body Shape Models (SBSMs) (see Figure 2). The ATD was segmented in a way to depict the ATD, to determine the segment masses and overal center of gravity of the ATD required. The table shown in Figure 2 shows the target segment weights, including the overall target center of gravity for the ATD. Figure 3. Overlay of ICAM Scans and UMTRI Body Shape Since the body shape was in the seated position and the ICAM scans were from the supine position, it was necessary to determine how to use one with the other. As shown in Figure 4, scans were placed at different body landmarks provided with the UMTRI models. Using this method the locations of the ribs, organs, spine, and pelvis were determined. Beebe 3

T7 L4 It was determined that the liver and spleen movement was negligible and substantiated the use of MRI scan data for positioning. It was also determined that the flesh moved similarly to what was shown in Figure 5. Therefore, supporting the use of UMTRI s body model for the external body contour. T10 L5 Figure 4. Overlay of ICAM MRI Scans into UMTRI Body Model It was also seen that the flesh is different from the supine to the seated posture as shown in Figure 5. To determine if the organs moved as much as the flesh, a PMHS was dissected at The Ohio State University lab and repositioned from supine to the Automotive Seated posture (Figure 6). Figure 6. Comparison of Supine and Automotive Seated Posture using PMHS ATD Design The design was guided by the scans and shape to locate organs, spine, rib shape and size, and flesh thickness throughout the entire upper and lower torso and upper legs. As determined from the 2015 Humanetics Obese ATD project, it was important to provide the correct flesh thickness since this will determine where the seat belt would lie and how much the belt will need to travel through before coming in contact with hard skeletal structures. Figure 7 shows the overall design of the Elderly ATD. Each segment was chosen or designed to meet the Anthropometric requirements. Figure 7. Overall Elderly ATD Design Figure 5. Comparing Scans to Outer Shape The ATD was made up of standard parts for the head, neck, lower arms, pelvis bone and knee. New designs Beebe 4

were created for the rest of the ATD. The following is a description of the design for each segment. Floating Shoulder Head and Neck It was determined that the head and neck from the current WorldSID Small Female would be used on the Elderly ATD. The head size and weight are similar to the body shape model. The head coupled with the current neck, provides potential frontal and side responses which would be reviewed during the testing of the ATD in different configurations Figure 8). Large Child Design Figure 8. WorldSID Small Female Head and Neck on Elderly ATD Shoulder Design The shoulder design for the Elderly ATD consists of a clavicle, sliding scapula, and a ball joint for the arm attachment (Figure 9). The clavicle and sliding scapula design was chosen based on a Humanetics child ATD design completed in 2010. Humanetics impact testing showed that this design could be used for both frontal and side configurations. The scapula is mounted to the ATD by rubber blocks which permit the shoulder to move in all directions. The arm attachment is a ball joint to provide the range of motion and is compact in design. All the pieces of the shoulder are made using additive (3D printing) manufacturing techniques. Figure 9. Upper Torso Shoulder and Rib Design Spine Assembly The spine consists of four major sections (see Figure 10). The neck and shoulder mount, the upper flexible joint, the main body, with the standard thorax load cell, and the segmented lumbar spine. The spine was made by using additive manufacturing techniques. Beebe 5

Upper flexible Joint Neck and shoulder mount body landmarks from the UMTRI shape with the MRI scan provided the information needed to develop the rib cage and organ design (see Figure 11). Main Body with Load Cell Segmented Lumbar Spine Figure 10. Spine Assembly The neck and shoulder mount and main body are made from 3D printed aluminum. Integrating the shoulder mount and neck bracket was made easier and in one piece with the utilization of 3D printing techniques. Also the main body had sections designed to accommodate four IRTRACC s. The upper flexible joint and lumbar spine are fabricated from 3D printed rigid plastic plates with 3D printed rubber like discs in between. The load cell is a standard Hybrid III Small Female Thorax load cell. Tri axial accelerometers can be mounted at the front of the spine box and at T-12 locations. Thorax and Abdominal The thorax is a major injury location in motor vehicle crash occupants. Thoracic trauma is the principal cause of 30% of road traffic deaths 3. The thorax contains a variety of critical physiological processes. For example, housing the primary elements of the respiratory and circulatory systems. The rib cage protects the inner organs, including the liver, spleen, kidneys, and stomach. It is evident that the chest, more than any other body region, is particularly vulnerable to crash injury as the subject ages. The total injury rates are higher in elderly motor vehicle crash occupants than in younger occupants and there are significant differences in their respective injury patterns, particularly thoracic, in incidence and severity. [4] The thorax and abdominal sections of the ATD are developed together as a system approach and not two independent assemblies connected together. The goal was to develop the rib cage, liver and spleen system which met the location and size requirements based on the MRI scans provided from ICAM. The rib shape, organ size, and placement is patterned after the MRI scan from ICAM. The overlay aligning Figure 11. Rib Cage Scan Used to develop Rib Cage Design The ribs are designed to use constrained layer damping in place of the standard free layer damping conventional crash dummies have used for years. The design consists of a rib with two bands of a spring like plastic material connected on the ends and rubber like damping material placed in the middle between the bands (Figure 12). Plastic bands on the outside and inside Figure 12. Sample of Elderly Rib Design Rubber Like material added between the bands To eliminate the conventional jacket and foam pieces used in existing dummies, each rib was provided with a slip on soft plastic layer covering the rib while providing the outside contour shape required. This permits the ribs to move more independently from each other from side to side and top to bottom. A tailor fitted neoprene jacket with a durable Cordura chest cover is then added over the ribs to smooth the contour (Figure 13). Beebe 6

Spleen Lower IRTRACC s Liver Figure 13. Thorax Rib Coverings The organs chosen to be represented in the Elderly ATD are the liver and spleen. Research has shown in the AIS 3 category, the liver was the most frequently injured organ in frontal, right side and far side crashes; this was followed by spleen trauma. In contrast, the spleen sustained the maximum number of injuries in left and near side impacts. [5] More biofidelity in this region provides greater insight on potential injury criteria. Flesh Spleen Rear Organ support The abdominal cavity is the largest cavity of the human body. The liver is largest internal organ through which about 1.5 liters of blood flows each minute. This makes any injury or laceration to the organ a potential for large amounts of blood to leak into the abdominal cavity. The spleen also has a rich blood supply and bleeds extensively when injured. [6] To determine deflection of these organs, the lower IRTRACC s of the ATD went through the liver area and just above the spleen. Additional deflection bands (connecting IRTRACCs) were added in front of each organ to also capture deflection directly in the liver and spleen areas (Figure 14). Abdominal Rib Abdominal IRTRACC s Figure 14. Organ Layout in the Elderly ATD The liver and spleen are designed to be adjusted as more testing and biomechanical data becomes available. They are designed to represent the overall shape and size of each organ, but are made with an internal hex pattern so that stiffness can be adjusted. The parts are 3D printed from a rubber like material (Figure 15). Beebe 7

Rear Abdomen Flesh Spleen Figure 15. Design Concept of Liver and Spleen Structures Preliminary modeling has also been done to experiment with different sizes and shapes of the structure to adjust the stiffness as required. The flesh to locate the organs is based on the UMTRI outer shape and is 3D printed from a soft rubber like material with additional structural holes under the skin to adjust stiffness as necessary (Figure 16). The liver was divided into two parts to permit the IRTRACC to go through the center of the liver area. Liver Figure 16. Abdominal Flesh with Organs Pelvis Front Abdomen Flesh The pelvis consists of a standard Hybrid III Small Female bone, upper femurs, ASIS load cells, and 3D printed soft rubber like flesh (Figure 17). Figure 17. Pelvis Assembly The stiffness of the flesh is controlled by the material and internal coring to vary the stiffness from side to side, bottom, and front areas of the pelvis. The small Beebe 8

This image cannot currently be displayed. female bone was used due to the fact that the ASIS lateral spacing was similar to the spacing provided in the body land marks from ICAM and UMTRI. Upper Legs The upper leg structure consists of a standard Hybrid III Small Female leg bone slightly extended to match the 1.6 m stature. The knee assembly is the Hybrid III Small Female knee assembly. The external shape of the thigh flesh is designed to match the shape of the UMTRI shape model in the pelvis area and then match the standard knee flesh on the other end (Figure 18). 3D printed upper flesh cap 3D printed upper arm bone Std. Small Female lower arm and hand Figure 19. Arm Assembly for Elderly ATD Instrumentation Available for Elderly ATD Table 2 contains a list of possible instrumentation available for the current version of the Elderly ATD. Figure 18. Elderly ATD Leg Assemblies Table 2 Current Instrumentation for Elderly ATD Lower Legs The lower legs are standard Hybrid III Small Female design but extended 24 mm to match the UMTRI 1.6 m profile. Therefore a new flesh is 3D printed. The design allows for the fitting of upper and lower tibia load cells. The foot is standard HIII. Arms The arms consist of a standard lower arm and hand assemblies from the Hybrid III Small Female and upper arm has a new upper arm bone, which is longer than the standard Small Female arm to meet the length of the UMTRI arm and is made from a 3D printed rigid plastic. The flesh of the upper arm contains a standard upper arm flesh from the Hybrid III Small Female with a 3D printed soft rubber like material at the top to cover the area that was lengthened (Figure 19). Transducer Type Dummy Location No of Channels Accelerometer Head (World SID SF 3 mount) Upper Neck Load Head (World SID SF) 6 Cell Accelerometer Thorax 3 Mid Spine load cell Std. THOR spine load cell 6 Accelerometer T12 3 IRTRACC Thorax (4) 3 channel type Tilt sensors Thorax T4 1 IRTRACC Abdomen/Organ/Pelvis (2) 1 channel type Accelerometers Pelvis Cavity 3 Iliac Wing Load Pelvis 3 each Cells Femur Load cell Upper Leg 3 or 6 channel type Knee slider Potentiometer Knee 1 channel each side Lower leg load cells Lower Leg Up to 6 channels each side Completed ATD Verifications Beebe 9

ATD Anthropometry The ATD weight compared to the targets, after adding ballast, is shown in Table 3. Table 3. Weight Summary vs Targets Segment Current Weight of ATD UMTRI Date Segmented like ATD (targets) Head 3.75 3.8 Neck 0.263 0.9 Upper torso 21.09 19.1 Pelvis & Abdomen 29 29.7 Upper legs 8.3 8.2 Lower legs & Feet 8.14 6.6 Arms 3.1 4.9 TOTAL 73.643 73.2 Figure 20. Thorax Impact Testing The results of impacting the thorax at 4.3 m/s is shown in Figure 21. Peak deflections are 30 mm with peak forces at 3400 N. The hysteresis is 76%. Current Component Testing to date Thorax Impacts Thorax impact testing (Figure 20) was performed to review the initial response of an ATD of this shape and size. Additionally, the impact results will create a picture of what to expect from 3D printed parts, and serve as a baseline for expectations moving forward. It was decided to impact the EATD with the standard 23.4 kg pendulum used to impact the Hybrid III 50 th Male ATD, since these two ATDs are the closest in weight. This size pendulum exposed the EATD to higher levels to review the durability of the system. Figure 21. 4.3 m/s thorax impact results Next, lower oblique impact tests were conducted to develop a baseline result for this area of the ATD as well. These tests were also conducted with the 23.4 kg pendulum at 4.3 m/s (see Figure 22). The peak deflection was just over 30 mm and the peak force almost 4500 N. Beebe 10

axis IRTRACC s were placed in the pelvis to measure abdominal intrusion. Figure 22. 4.3 m/s Oblique Thorax Impact Test Side Impact Sled Testing Results The Elderly ATD was taken to Honda in Ohio to be tested in a side impact sled test. The test was at 50 kph with a side air bag, seat and door panel (Figure 23). One test was conducted to provide a baseline of side impact performance for durability and to compare with PMHS later this year. Figure 24. Chest band installed on Elderly ATD Test Results Baseline Data from the data channels Figure 25 provides the sled pulse which was used in the sled testing. Figure 23. Set up of Elderly ATD in Side Impact Test Fixture at Honda The Ohio State University provided a 59 channel chest band to provide shapes during the sled test, see Figure 24 of chest band on the ATD. The ATD contained 4, 3 channel IRTRACC s positioned on the right and left side of rib 3 and 6. Two other single Figure 25. Sled Pulse (G s) Figure 26 provides the ATD X direction of the ITRRACC s for right and left rib 3 and 6. The left Rib 3 X axis had the most deflection of 20 mm with lowest being the right rib 6 data. The belt moved to the left during the test. The rotations about the Z axis on the IRTRACC s are shown in Figure 27. The largest motion in the Z-axis was the IRTRACC on the left side on rib number 3. Right Z on rib number 6 failed. Beebe 11

The experimental abdomen/pelvis deflection measurements, shown in Figure 28, did respond as planned to provide deflection data across the pelvis and abdomen areas of the ATD. Figure 28. Right and Left Side Abdomen/Pelvis X axis IRTRACC s (mm vs msec) Figure 26. Left and Right X direction Results from IRTRACC s (mm vs msec) Chest Band Results The 59 channel chest band provided baseline information of how this ATD performed in a pure side impact test. These results will assist in the development process to make a better omnidirectional ATD. Figure 29 provides a sequence of shapes during the test. Durability Results Figure 27 Left and Right Z direction results from the IRTRACC s (Degree vs msec) Two items were seen during the testing, one is that the right arm broke off at the ball joint when the arm was free to flail (Figure 30) coming across the thorax and striking the inner door. The second item was the left scapula which fractured during the test due an inadequate amount of clearance between the scapula and the neck bracket. The right side shows more deflection then the left side, 5 vs 1.5 mm. This result matched the direction of the ATD sliding toward the right side into the buckle as shown in the films. Figure 30. Post Test Beebe 12

Sternum gage 14 CONCLUSIONS Impact Side Time Zero Spine gage 50 The 3D printing process has been shown to be an invaluable tool to design and develop crash dummies without the need to develop molds. Durability has been shown to be good in some areas but some areas need improvement, so different materials, such as printed materials with Kevlar or Carbon Fibers, will be used. The many materials available today and more tomorrow will continue to advance the process of making better crash dummies. 2.3 The design target weight for mass and size was achieved using this manufacturing process. To better understand about belt interaction with overweight occupants, exploration into pressure measuring organs with new types of abdominal deflection measurement systems showed promise. Elderly ATD Updates The next steps of the Elderly ATD development is to continue component testing and update the design based on what has been learned to date. The following is our plans for the update of the current ATD and upcoming testing (see Table 4). 3.3 4.73 7.73 12.5 Figure 29. Chestband Data (mm) Beebe 13

Part Neck bracket Spine Lumbar spine Scapula Clavicle Sterum Ribs Chest jacket Upper arm and socket Rib covers Organs Pelvis flesh Legs Table 4. Summary of Updates and Testing Design Update Increased clearance for scapula movement Increase area of rubber for durability + 2 cables Material Update Steel to meet weight traget without ballast Steel to meet weight traget Improved rubber like material OSU PMHS Match Pair Testin g (April) Compone nt Lab Testing (March June) X Honda Side impact sled testing (June) Plastic w/kevlar Plastic w/kelvar Plastic w/kevlar Plastic X X X w/kevlar X Improve fit Improve ball attachment Improve fit to prevent cracks Make less stiff by revising structures Redesign for better fit and durability Redesigned to match UMTRI legs and shapes Plastic w/kevlar Improved rubber like material Improved rubber like material Improved rubber like material Improved rubber like material X [4] Ejima, Susumu, et al. "Application of Analytic Morphomics for Belted Elderly Occupants in Frontal Crashes." Orthopedics 1 (2016): 5. Senior Sled Testing (Sept Feb) [4] Yoganandan, Narayan, et al. "Patterns of abdominal injuries in frontal and side impacts." Annu Proc Assoc Adv Automot Med. Vol. 44. 2000. [5] Hyde, Alvin S. Crash injuries: how and why they happen. A primer for anyone who cares about people in cars. 1992. REFERENCES [1] New Data on Older Drivers. Centers for Disease Control and Prevention. Office of the Associate Director for Communication, Digital Media Branch, Division of Public Affairs, April 27, 2015. Web. 2015 [2] Braver, Elisa R., and R. E. Trempel. "Are older drivers actually at higher risk of involvement in collisions resulting in deaths or non-fatal injuries among their passengers and other road users?." Injury Prevention 10.1 (2004): 27-32. [3] Beahlen, B., Beebe, M. Humanetics Innovative Solutions, Crandell, J., Forman J., Joodaki, H., University of Virginia, Center for Applied Biomechanics, ESV Paper 15-0325 Beebe 14