Air Eliminators and Combination Air Eliminators Strainers

Similar documents
Air Eliminators and Combination Air Eliminators Strainers

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. Page 1 of 12

Type ACE95jr Tank Blanketing Valve

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Types ACE95 and ACE95Sr Tank Blanketing Valves

Dean Pump Self-Priming Chemical Process Pumps

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

APPLICATION NOTES: PROCESS GUIDELINES FOR USING BORON TRIBROMIDE (BBr 3 )

T208VR Series Tank Blanketing Vacuum Regulator

How To Troubleshoot Low Pressure On Well Systems Page 1

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

1805 Series Relief Valves

CASH VALVE TYPE KP BACK PRESSURE VALVES

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Application Worksheet

DANFLO Control Valves 400 Series Model 20

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

TECHNICAL DATA CAUTION

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Aperval Pressure Regulators

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

627 Series Pressure Reducing Regulators

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Features. General application. Technical data

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

MEGR-1627 Instruction Manual

Y692VB Series Vacuum Breaker

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Eaton Filtration, LLC

S300 Series. Valve Link. Features. Fisher Controls

Type EZH Relief or Backpressure Regulator

PRO-50 Instrument Supply Regulator

North American Simplex Basket Strainers for Gas and Oil

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type 1190 Low-Pressure Gas Blanketing Regulator

Liquid Level Controllers

Bubble Tube Installations

Tank Blanketing Pressure Regulators RHPS Series

Norval Pressure Regulators

Alkylphosphines. Storage and Handling Recommendations

pumping gases JET PUMP TECHNICAL DATA

The Hoffman Specialty Series 2000 consists of main

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

TECHNICAL DATA. Q = C v P S

FloWash. Industrial Filter Cart

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

How to use the PBM Flow Calculator Spreadsheet (V2.04)

G Corp PO Box 5322 Lacey, WA CORP.CO User Instruc on/ Safety Manual

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type Y692 Gas Blanketing Regulator System

Engineering / Technical Section

BACK PRESSURE / SUSTAINING

Installation, Operation, and Maintenance Manual

Technical Information

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

DAV Series. DAV-MH Air Release & Vacuum Break Valves

SCA Series Inverted Bucket Steam Traps

TECHNICAL INFORMATION

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

Wet pipe low flow foam/water system

Materials : Carbon steel ASTM A216 WCB

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type R622 Pressure Reducing Regulator

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Type Cronos Pressure Reducing Regulator

Float Operated Level Controllers

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

1805 Series Relief Valves

BACK PRESSURE / SUSTAINING

Model DE-1, VDE-1 and DE-2 Air Release Heads

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Norval Pressure regulator

Slam Shut Valves SCN

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Type 299 Pressure Reducing Regulators

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Transcription:

Descrip on Air Eliminators and Combina on Air Eliminator Strainers are designed to provide separa on, elimina on and preven on of air in piping systems for a variety of installa ons and condi ons. Design Specifica ons DS-AIRELIM Revision 05 Air Eliminators and Combination Air Eliminators Strainers Posi ve displacement and turbine meters, being volumetric measuring devices, cannot differen ate between liquid, air and vapor. Although the air content, in most instances, is small when compared with the product, it will contribute to measurable error. Large amounts of free air or vapor entrapped in a piping system, not only compromises meter accuracy but can lead to overspeeding of the measuring unit, crea ng excessive wear or possible unit failure. To insure accurate liquid measurement, it is necessary to remove all vapor and free all entrained air from the system prior to entry into the measuring unit. Design Features High capacity air elimina on provides maximum meter protec on and superior measurement accuracy Large screen area means less frequent cleaning Ver cal tank facilitates installa on Wide variety of materials, screen sizes and pressure ra ngs Easy maintenance Principle of Opera on Air Eliminators decrease the velocity of the flowing stream and bring the liquid to a state of rela ve calm so that air bubbles or vapor will rise. As air and vapor collect in the top of the vessel, liquid volume is displaced (Reference Figure 1). Figure 1: Principle of Opera on Once displaced to a predetermined point, a floatoperated valve opens and the accumulated air and 1 SC-20, SC-24, SC-30 RL-24, RL-30, RL-36, RL-48 vapor is discharged from the tank. Liquid level then rises, causing the float-operated valve to close. Discharge rate is regulated by back pressure on the outlet side of the eliminator. If sufficient pressure differen al is not available to maintain a proper rate, a back pressure valve should be installed. Materials of Construc on Combina on Strainer/Air Eliminator with SC Eliminator Head: 150 psi: Carbon steel body with steel SC Eliminator Head 300 psi: Carbon steel body with duc le iron/ steel 180120 Eliminator Head SC Combina on: Head and Body, Aluminum only Applica ons DA-3-150 Combina on (Illustra on) DA-3-4-150 Combina on DA-6-4-150 Combina on DA-6-150 Combina on SC Combina on In most applica ons, free air is eliminated without difficulty. Air which has become entrained in the product and carried along with the stream, however, must be separated from the liquid product and collected as free air before it can be discharged effec vely. Entrained air in gasoline and low viscosity products separates and rises to the surface

quite rapidly when the liquid velocity is decreased sufficiently. As viscosity increases, the rate of separa on and rise of entrained air decreases and more reten on me is required to effect surface opera on. Because tank size is a considera on in the storage and dispersal of collected air and vapor, it is not always economical to remove entrained air from the system. When considering installa ons handling such products as heavy oils, it is usually far more economical to prevent the entrance of entrained air rather than eliminate it. Products such as fuel oil, diesel oil and kerosene have a tendency to foam, causing air to be discharged in the form of vapor. Petroleum products in this form are hazardous when discharged to the atmosphere and, for this reason, require large air eliminators to accommodate increases in surface tension. Sources of Air or Vapor in Piping Systems Condi ons leading to severe air problems can o en be eliminated or improved at the design stage, or through a comprehensive preven ve maintenance program. Factors frequently contribu ng to air and vapor problems include: Pumping into or out of storage through the same line Allowing the forma on of vortex condi ons in low levels of product High suc on vacuums can pull in finely divided air through packing glands Above-ground or heat-absorbing lines exposed to the sun can cause vaporiza on High pressure drop across valves can cause release of dissolved gases Lack of or improperly placed check valves can allow lines to par ally drain during idle periods A suc on vacuum that is too high for a vola le product Allowing a storage tank to become completely empty The accompanying graph illustrates the approximate amount of free air that can be discharged through Air Eliminator Heads at various pressures exis ng within the collec on tank. EXAMPLE: A 30 psig tank pressure would be required to discharge 180.3/min. free air through a SC eliminator head. Sufficient back pressure on the air eliminator must be present for the air eliminator head to func on and discharge properly at any given flow rate. To determine the approximate rela onship between gallons per minute and cubic feet per minute, consider the following formula: 2 Selec on of the Air Elimina on Device Air Eliminators for a given job should be selected on the basis of flow rate, viscosity and the magnitude of the air problem incurred. Normally, the problems incurred that require the elimina on of free air can be classified in one of three condi ons. Condi on One: Ven ng Free Air from a Piping System - Star ng a New Installa on or Filling a System A er Drainage In most cases, a simple air elimina on device combined with a strainer will perform sa sfactorily and is the most economical method. This combina on offers protec on of the meter against intrusion of foreign material and eliminates free air that could cause meter inaccuracy. CAUTION: During start-up or a er maintenance, slowly purge the line un l it is filled with liquid and all air and vapor have been removed. Condi on Two: Moderate Amounts of Air Requiring a Separate Air Elimina ng Vessel and Ven ng Device In applica ons involving moderate amounts of free or entrained air or when highly viscous products are being measured, an elimina on tank is recommended for proper reten on me. In Condi on One the strainer body allows very li le me for air to be released to the surface. Condi on Two, for moderate to heavy concentra ons of air, requires a reduc on in product velocity as well as more reten on me before release of air or vapor, thus the need for a larger receiving/holding tank. Applica ons common to this condi on include those which have allowed the product tank to completely empty, failed to properly close a valve, very low storage tank levels or have been loaded and unloaded through a common line. Condi on Two is limited to those applica ons in which no high, con nuous volumes of entrained gas or air may result from either system failure or human error. gpm = 7.5 x. 3 /min. OR. 3 /min. = gpm/7.5 Figure 2: Air Capacity of Air Eliminator Head Assemblies

Condi on Three: Cri cal Condi ons Involving Large Amounts of Air or Gas Entrainment Typical applica ons may involve: Unloading transport trucks, tank cars or pumping from barges or tankers Pumping from underground storage Piping systems used for several different opera ons and products (air is introduced when changing products) Lines with occasional drainage between products Above-ground and heat-absorbing lines exposed to the sun can result in the release of solu on gases and boiling of light ends where high vapor pressure products are u lized Pumping in and out of the same line High turbulence created by high liquid velocity, valves, fi ngs, etc. Viscous products greater than Number 2 Fuel Oil Lines blown down with compressed air or those allowed to run dry Air Eliminator Selec on Tables Tables 1, 2 and 3 below, provide a general basis for selec ng type and size and list the three most common problem areas. All informa on listed has been developed using light oils such as gasoline, kerosene, light fuel oil, diesel products etc. Contact the factory for applica ons of higher viscosity in which air problems may require special engineering a en on. Vessel Loading and Off-Loading Free air introduced into the piping system caused by vortexing, stripping bo om product or simply unloading mobile tankers or sea-going vessels is a problem which requires special a en on. The unloading of rail cars or road tankers (Figure 3) o en requires the air eliminator vessel to have a liquid level float as an interface to close the discharge valve downstream of the meter. This stops all flow when liquid level drops to a predetermined point in the vessel. The valve must have adequate closing me to minimize the introduc on of surges yet fast enough to eliminate the air being displaced in to the metering system. For off-loading seagoing vessels (Figure 3), secondary or mul ple air release devices may be required to assist with air elimina on before entering the metering system. Contact the factory for recommended procedure when flow rate exceeds standard vessel size or when such condi ons exist. Table 1, Condi on 1 SC Combina on DA-3/DA-3 Combina on DA-3-4/DA-3-4 Combina on D-6 Combina on GPM 60 100 150 200 300 400 500 600 700 800 900 1,000 1,200 IGPM 50 80 125 160 250 332 415 500 580 665 750 830 1,000 LPM 220 375 570 750 1,135 1,500 1,900 2,270 2,650 3,028 3,406 3,800 4,550 BPH 85 140 215 285 425 570 715 850 1,000 1,143 1,285 1,430 1,700 M 3 H 14 23 34 45 68 91 114 136 159 182 205 227 272 Table 2, Condi on 2 SC-20 SC-24 SC-30 GPM 300 400 500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500 IGPM 250 332 415 500 580 665 750 830 913 1,000 1,079 1,162 1,250 LPM 1,135 1,500 1,900 2,270 2,650 3,028 3,406 3,800 4,164 4,550 4,920 5,299 5,678 BPH 425 570 715 850 1,000 1,142 1,285 1,430 1,572 1,700 1,857 2,000 2,140 M3H 68 91 114 136 159 182 205 227 250 272 295 318 340 Table 3, Condi on 3 RL-24 RL-30 RL-36 RL-48 GPM 100 300 600 800 1,200 1,500 1,700 2,000 2,300 2,500 2,700 2,900 3,100 3,300 3,500 IGPM 80 250 500 665 1,000 1,250 1,416 1,666 1,916 2,083 2,249 2,416 2,582 2,749 2,916 LPM 375 1,135 2,270 3,028 4,550 5,678 6,435 7,570 8,706 9,463 10,220 10,977 11,734 12,490 13,248 BPH 140 425 850 1,142 1,700 2,140 2,428 2,857 3,286 3,571 3,857 4,143 4,429 4,714 5,000 M3H 23 68 136 182 272 340 386 454 522 568 613 658 704 744 795 3

Figure 3: Rail Car and Tanker Off-Loading and Marine Tanker Off-Loading 4

Table 4: Dimensions for Combina ons and Air Eliminators Air Eliminators Combinations A B C D E Model Inches mm Inches mm Inches mm Inches mm Inches mm SC See Figure 4 DA-3-150 -- -- 28 711 13 1/8 330 -- -- 10 1/4 260 D-3-300/150 -- -- 27 7/8 708 15 23/32 400 -- -- 10 1/8 257 D-3-300 -- -- 27 7/8 708 15 23/32 400 -- -- 10 1/8 257 DA-3-4-150 -- -- 27 3/4 705 13 1/8 330 -- -- 10 1/4 260 D-3-4-300/150 -- -- 27 7/8 708 15 23/32 383 -- -- 10 1/8 257 D-3-4-300 -- -- 27 7/8 708 15 23/32 383 -- -- 10 1/8 257 D-6-4-150 -- -- 39 1/2 1003 22 5/8 575 -- -- 15 3/8 391 D-6-150 -- -- 39 991 22 5/8 575 -- -- 16 1/8 410 SC-20 18 457 40 1016 23 584 -- -- 10 3/4 273 SC-24 24 1/4 616 61 5/8 1565 30 762 -- -- 13 330 SC-30 30 762 67 3/4 1721 36 1/2 914 -- -- 16 406 RL-24 std 24 610 64 1625 30 762 35 889 13 330 RL-24-4 S/O 24 610 64 1625 30 762 34 15/16 887 13 330 RL-24-4 W/N 24 610 64 1625 35 1/4 895 34 15/16 887 13 330 RL-30 29 5/8 752 71 1/2 1816 36 1/2 927 38 965 16 406 RL-36 36 914 79 1/2 2019 43 1092 42 1067 18 457 RL-48 48 1219 91 2311 57 1447 46 1168 22 1/2 572 RL-48-285 48 1219 93 3/4 2381 57 1447 45 1143 26 660 5

Installa on Installa on of the air eliminator must be on the upstream inlet side of the meter on the discharge side of the pump. Discharge may be vented to the meter outlet, back to storage, or into a sump, condensa on drum or tank. CAUTION: Local, state and federal regula ons should be checked prior to ven ng to atmosphere or an open vessel. Op onal Equipment Conversion from Strainers to Combina on Air Eliminator Strainers Exis ng strainers may be converted for air elimina on by adding an air eliminator head assembly. A. For Model DA-3-150, DA-3-4-150 and D-6-150 strainers, an assembly consis ng of the strainer cover, air eliminator housing and air eliminator assembly may be provided for conversion. Figure 5: Dimensions for Strainer Conversions Strainer Model Air Elimina on Kit DA-3-150 W180575 DA-3-4-150 W180575 D-6-150 W178865-001 B. For 300 psi strainers, sizes 3 and 4 an assembly consis ng of the 180120 Air Eliminator Head and moun ng flange assembly may be provided. (Welding of the strainer cover is required and it is necessary that a hole be cut to allow passage of fluid through the strainer to the air eliminator.) Assembly Part Number W180120 (Reference Fig. 5). C. To convert larger strainers and strainers of other manufacturers, complete self-contained air eliminator assemblies may be provided. Moun ng of these units is accomplished by the addi on of a 2 pipe coupling welded onto the strainer cover. Units available include (Reference Figure 5): 180150 SC Air Eliminator Assembly for pressures up to 150 psi 180140 HP-300 Air Eliminator Assembly for pressures up to 300 psi 180140-740 HP-740 Air Eliminator Assembly for pressures up to 720 psi 6

Figure 6: Assemblies for Welding Directly Into Tanks or Filters 7

Table 5: Specifica ons Air Eliminators Combinations Angle Model Head Assembly Vent Size NPT Drain Size Approximate Shipping Approximate Shipping Cube Weights lbs kg Cubic ft Cubic mtrs SC-20-3 SC 1" 3/4" NPT 140 64 10.11 0.286 SC-24-3 SC 1" 1" NPT 295 134 26.9 0.762 SC-30-3 SC 1" 1" NPT 750 341 43.68 1.237 RL-24-4 RL 2" 1" NPT 500 227 26.66 0.755 RL-30-4 RL 2" 1" NPT 800 364 45.6 1.29 RL-36-4 RL 2" 1" NPT 1200 545 70.77 2 SC-24-6 SC 1" 1" NPT 295 134 26.9 0.762 SC-30-6 SC 1" 1" NPT 750 341 43.68 1.237 RL-24-6 RL 2" 1" NPT 500 227 26.66 0.755 RL-30-6 RL 2" 1" NPT 800 364 45.6 1.29 RL-36-6 RL 2" 1" NPT 1200 545 70.77 2 RL-48-6 RL 2" 1" NPT 2500 1136 144.08 4.08 SC-30-8 SC 1" 1" NPT 750 341 43.68 1.237 RL-30-8 RL 2" 1" NPT 800 364 45.6 1.29 RL-36-8 RL 2" 1" NPT 1200 545 70.77 2 RL-48-8 RL 2" 1" NPT 2500 1136 144.08 4.08 RL-36-10 RL 2" 1" NPT 1200 545 70.78 2 RL-48-10 RL 2" 1" NPT 2500 1136 144.08 4.08 RL-48-12 RL 2" 1" NPT 2500 1136 144.08 4.08 RL-48-16-285 RL 2" 1" NPT 2800 1273 144.08 4.08 SC SC 1" -- 23 10 1.15 0.033 DA-3-150 SC 1" 3/4" NPS 66 30 2.268 0.064 D-3-300/150 180120 3/4" 1" NPT 120 55 2.59 0.073 D-3-300 180120 3/4" 1" NPT 120 55 2.59 0.073 DA-3-4-150 SC 1" 3/4" NPS 70 32 2.268 0.064 D-3-4-300/150 180120 3/4" 1" NPT 135 61 2.59 0.073 D-3-4-300 180120 3/4" 1" NPT 135 61 2.59 0.073 D-6-4-150 SC 1" 1" NPT 190 87 8.52 0.24 D-6-150 SC 1" 1" NPT 190 87 8.3 0.024 DA-3-150A SC 1" 3/4" NPT 66 30 2.268 0.064 DA-3-4-150A SC 1" 3/4" NPT 70 32 2.268 0.064 D-6-4-150A SC 1" 1" NPT 190 87 8.52 0.24 D-6-150A SC 1" 1" NPT 190 87 8.3 0.235 8

Table 6: Flange Connec ons Air Eliminators Combination Angle Model SC-20-3 Flange Connections Maximum Working Pressure @ 100F 9 DIN Connections Maximum Working Pressure SC-24-3 SC-30-3 SC-20-4 SC-24-4 3" 150 lb. ANSI R.F. 4" 150 lb. ANSI R.F. 150 PSI 150 PSI DN 80 PN 16 DN 100 PN 16 10.3 Bars 10.3 Bars SC-24-4 Low Temp 4 150 lb. ANSI W.N. 285 PSI DN 100 PN 40 19.6 Bars SC-24-6 6 150 lb. ANSI R.F. S/O 285 PSI DN 150 PN 40 19.6 Bars SC-30-4 RL-24-4 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars RL-24-4 4 150 lb. ANSI R.F. S/O 285 PSI DN 100 PN 40 19.6 Bars RL-24-4 4 150 lb. ANSI R.F. W/N 285 PSI DN 100 PN 40 19.6 Bars RL-30-4 RL-36-4 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars SC-24-6 SC-30-6 RL-24-6 RL-24-6 6" 150 lb. ANSI R.F. 6 150 lb. ANSI R.F. S/O 150 PSI 285 PSI DN 150 PN 16 DN 150 PN 16 10.3 Bars 19.6 Bars RL-30-6 RL-36-6 RL-48-6 SC-30-8 6 150 lb. ANSI R.F. 150 PSI DN 150 PN 16 10.3 Bars RL-30-8 RL-36-8 RL-48-8 RL-36-10 RL-48-10 8" 150 lb. ANSI R.F. 10" 150 lb. ANSI R.F. 150 PSI 150 PSI DN200 PN 16 DN 25 PN 16 10.3 Bars 10.3 Bars RL-48-12 12" 150 lb. ANSI R.F. 150 PSI DN 30 PN 16 10.3 Bars RL-48-16-285 16" 150 lb. ANSI R.F. S/O 285 PSI DN 100 PN 40 19.6 Bars SC (All Aluminum) 2" NPT Companion 150 PSI N/A N/A DA-3-150 3" 150 lb. ANSI R.F. 150 PSI DN 80 PN 16 10.3 Bars D-3-300/150 3" 150 lb. ANSI R.F. 285 PSI DN 80 PN 16 16 Bars DN 80 PN 40 19.6 Bars D-3-300 3" 300 lb. ANSI R.F. 300 PSI DN 80 PN 40 20.7 Bars DA-3-4-150 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars D-3-4-300/150 4" 150 lb. ANSI R.F. 285 PSI DN 100 PN 16 16 Bars DN 100 PN 40 19.6 Bars D-3-4-300 4" 300 lb. ANSI R.F. 300 PSI DN 100 PN 40 20.7 Bars D-6-4-150 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars D-6-150 6" 150 lb. ANSI R.F. 150 PSI DN 150 PN 16 10.3 Bars DA-3-150A 3" 150 lb. ANSI R.F. 150 PSI DN 80 PN 16 10.3 Bars DA-3-4-150A 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars D-6-4-150A 4" 150 lb. ANSI R.F. 150 PSI DN 100 PN 16 10.3 Bars D-6-150A 6" 150 lb. ANSI R.F. 150 PSI DN 150 PN 16 10.3 Bars

Brodie Interna onal 19267 Highway 301 North Statesboro, GA 30461 Phone: 001.912.489.0200 Fax: 001.912.489.0294 A Brodie Meter Co., LLC Company www.brodieintl.com The contents of this publica on are presented for informa onal purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warran es or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Brodie Meter Co., LLC reserves the right to modify or improve the designs or specifica ons of such products at any me without no ce.