Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors

Similar documents
Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14 SERIES

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

MAINLINE MLA14 AIR CONDITIONERS

FMU4X, FMC4X FMU4P, FMC4P

If you want to offer a more professional look to your

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

VARIABLE SPEED AIR CONDITIONERS

USER S INFORMATION MANUAL

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

ARCHITECTURAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

Design Guide /01. ThermAir Burners TA Series version 1.10

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

ENGINEERING DATA. Engineering Data

If you want to offer a more professional look to your

MRO Oil-Air Ratio Regulator

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Additel 780 Series Pressure Controller

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Additel 780 Series Pressure Controller

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

2 are both ways of saying a ratio of 2 to 5

Ruud Achiever Series Heat Pump

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

Eclipse Extern-A-Therm Recuperators

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

MAINLINE MLP14**A HEAT PUMPS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Base engine for use in U.S., the U.S. Territories, and Canada

Propane Conversion Kit Instruction

ACCESSORY KIT INSTALLATION MANUAL

Eclipse ThermJet Burners for Preheated Combustion Air Models TJ0015 TJ2000

D U A L F U E L R A N G E S

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Additel 780 Series Pressure Controller

LENNOX SLP98UHV DIAGNOSTIC CODES

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

IPG IGNITION GAS PILOTS BACK-LOADED GAS

FLOMIXERS SELECTION DATA ALL GASES

Your safety and the safety of others are very important.

Hydraulic lift crane. Complies with ANSI/ASME B 30.5 LR enus LR

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Typical Piping Layouts for PREMIX Blower Mixer Systems

CHAPTER 3 : AIR COMPRESSOR

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Propane Conversion Kit Instruction

TM420SDL - Air Compressor 100 Litre Tank / 3hp 14.6cfm / 416lpm Displacement

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

GAS SUPPLY APPLICATION GUIDE

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

WhisperValue DC. The ideal Multi-Family Solution High Performance Built for the Long Run

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

EXPLOSION PROOF PRESSURE SWITCH MODEL : P953 SERIES

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Rheem Classic Series Heat Pump

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS

Customer Responsibilities

208 Design Guide 2/4/2013

Tube Puller CP/CPS series. Pullers designed with cutting edge technology

Customer Responsibilities

6000SLX HYDRAULIC CRAWLER CRANE

Rheem Classic Series Two Stage Heat Pump

Work Horses of the Breathing Air Industry

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons

Rheem Classic Series Heat Pump

/ /

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

installation instructions

PGM PREPIPED GAS MANIFOLD

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices

INSTALLATION GUIDE Gas Rangetops

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

628 Differential Pressure Decay Leak Tester

UNDERSTANDING, ACCELERATED

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Liquid Level Controllers

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Air Operated Hydraulic Pumping Systems to 50,000 psi

40' SPARKMAN & STEVENS - NORTHSTAR -.CENTER COCKPIT - MOTIVATED SELLER

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Transcription:

THIS MODEL 80.0% 78% 82% 88% 97% Oil Furnaces Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors ROCA-***E: Highboy Series ROLA-***E: Lowboy Series Input Ratio from 84,000 to 175,000 BTU/HR [24.61 to 51.28 kw] ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID HIGH The Ruud Achiever Series premium upflow oil furnace is for installation in proper ventilated utility rooms, closets or alcoves. ECM blower assemblies for heating and air conditioning applications ECM Control board located in furnace vestibule ECM controls set for 2-stage air conditioning, 2-stage heat pump back up 10-gauge primary and 14-gauge secondary heat exchanger Front cleanout ports extend through front wall for accessibility Efficiencies up to 85.9% Front or rear flue Lowboys available All furnaces have standard Honeywell controls Available with Beckett, Riello Carlin burners Extended vestibule on all units Rely on Ruud. FORM NO. O22-616

Table of Contents TABLE OF CONTENTS Standard Equipment...3 Specifications & Dimensions...4 Model Number Identification...5 Blower Performance Data...6 Limited Warranty...7 2 Rely on Ruud.

Standard Equipment STANDARD EQUIPMENT The Ruud Achiever Series Oil Furnace is fully assembled and offers the option of 3 separate burner in a box combinations. Highboy and Lowboy configurations available. Standard Honeywell Controls and barometric draft control. The unit has an extended vestibule to conceal burner and operating controls. A 10-gauge primary and 14-gauge secondary heat exchanger include accessible cleanout ports that extend through the front wall of the furnace enclosure for ease of serviceability. Variable speed ECM motor and control board is engineered to accept 2-stage air conditioning and 2-stage heat pump backup. An external filter and filter rack is included ROCA series furnaces. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES Rely on Ruud. 3

Specifications and Dimensions Specifications and Dimensions ECM Motor FURNACE Furnace Type Lowboy* Highboy Model ROLA-070E ROLA-115E ROCA-070E ROCA-115E DIMENSIONS Cabinet Height (A) 40" 46" 53-5/8" 56-1/2" Cabinet Width (B) 20-1/4" 25-1/8" 22-1/4" 25-1/2" Cabinet Depth (C) 47-1/2" 53-5/8" 33-1/8" 38" Centerline - Flue to Floor (D) 31-1/4" 38-1/2" 49-1/8" 52-5/8" Centerline - Flue to Side (E) 10-1/8" 12-1/2" 11-1/8" 12-3/4" Warm Air Supply Depth (G) 17-1/2" 21-1/2" 19-3/4" 23-3/8" Warm Air Supply Width (Ho) 18-1/4" 22-7/8" 20-1/2" 23-3/4" Return Air Supply Width (Hr) 18-1/4" 22-7/8" 15" 15" Return Air Supply Depth (J) 14" 13-5/8" 23-5/8" 23-5/8" SPECIFICATIONS Flue Size 6" 6" 6" 6" Filter Size 16" x 20" (2) 16" x 20" (2) 16" x 25" 16" x 25" Blower Size 100-10T 100-10T 100-10T 100-10T Shipping Weight 323 lbs. 362 lbs. 298 lbs. 347 lbs. B.T.U.H. Input 84,000 105,000 119,000 140,000 175,000 84,000 105,000 119,000 140,000 175,000 B.T.U.H. Output 71,000 88,000 99,000 116,000 143,000 71,000 88,000 99,000 116,000 143,000 Beckett AFG Nozzle @ 100psi.60 80 A.75 80 B.85 80 B 1.00 80 B 1.25 80 B.60 80 A.75 80 B.85 80 B 1.00 80 B 1.25 80 B Riello 40 Nozzle @ 150psi.50 60 A.60 60 A.65 60 A.85 80 B 1.00 80 B.50 60 A.60 60 A.65 60 A.85 80 B 1.00 80 B Carlin EZ-1 Nozzle @ 100psi.60 70 A.75 70 A.85 70 A 1.00 60 SS 1.25 60 SS.60 70 A.75 70 A.85 70 A 1.00 60 SS 1.25 60 SS AFUE Seasonal Efficiency 85.9% 85.4% 85.0% 85.0% 84.2% 85.9% 85.4% 85.0% 85.0% 82.3% Blower Motor Drive Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Direct/ECM Heating Ext. Static Pressure In. [kpa].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05].2 [.05] Max. Ext. Static Pressure In. [kpa].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12].5 [.12] Temperature Rise Range F [ C] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] 50-75 [28-42] Blower Motor Full Load Amps 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 Total Current 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 Minimum Circuit Ampacity 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 * Specify front or rear flue on Lowboy models [ ] Designates Metric Conversions Lowboy Highboy 4 Rely on Ruud.

Model Number Identification Model Number Identification Highboy and Lowboy Models R O L A 070 E 04 B F Ruud Oil Furnace Type C = Highboy L = Lowboy Design Series [ ] Designates Metric Conversions Heating Input Designation (Output BTU/HR) 070 = 70,000 [20.5 kw] 115 = 115,000 [33.8 kw] Motor Type E = ECM Motor Heating and Cooling Designation 03 = Up to 3 tons cooling CFM for 070 models 04 = Up to 4 tons cooling CFM for 070 models 05 = Up to 5 tons cooling CFM for 115 models Burner Type B = Beckett Burners C = Carlin Burners R = Riello Burners Variations (Applies only to ROLA Models) F = Front Flue R = Rear Flue Rely on Ruud. 5

Blower Performance Data Blower Performance Data Highboy and Lowboy Models MODEL LOWBOY HIGHBOY ROLA-070E03 ROLA-070E04 ROLA-115E05 ROCA-070E03 ROCA-070E04 ROCA-115E05 Horsepower/Speed 3/4 HP, Variable Speed Heating CFM 900 1100 1250 900 1100 1250 1550 1925 900 1100 1250 900 1100 1250 1550 1925 Cooling CFM 1-1/2 Tons 600 600 600 N/A N/A N/A N/A N/A 600 600 600 N/A N/A N/A N/A N/A Cooling CFM 2 Tons 800 800 800 N/A N/A N/A N/A N/A 800 800 800 N/A N/A N/A N/A N/A Cooling CFM 2-1/2 Tons 1000 1000 1000 1000 1000 1000 N/A N/A 1000 1000 1000 1000 1000 1000 N/A N/A Cooling CFM 3 Tons 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 Cooling CFM 3-1/2 Tons N/A N/A N/A 1400 1400 1400 1400 1400 N/A N/A N/A 1400 1400 1400 1400 1400 Cooling CFM 4 Tons N/A N/A N/A 1600 1600 1600 1600 1600 N/A N/A N/A 1600 1600 1600 1600 1600 Cooling CFM 5 Tons N/A N/A N/A N/A N/A N/A 2000 2000 N/A N/A N/A N/A N/A N/A 2000 2000 Shipping Weight 323 323 323 323 323 323 362 362 298 298 298 298 298 298 347 347 6 Rely on Ruud.

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* The Manufacturer will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated here, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Oil Heat Exchanger...Limited Lifetime Any Other Part...Five (5) Years Rely on Ruud. 7

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.ruud.com Ruud Canada 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 04/12 DC FORM NO. O22-616