Short and ultrashort laser pulse induced bubbles on transparent and scattering tissue models.

Similar documents
Laser-Induced Bubbles in Glycerol-Water Mixtures

Effect of gases on radical production rates during single-bubble cavitation

Development of underwater laser cutting technique for steel and zircaloy for nuclear applications

The Characteristics of Cavitation Bubbles Induced by the Secondary Shock Wave in an HM-3 Lithotripter and Its Effect on Stone Comminution

SPIRIT III Radiometer Saturation Effect

Figure 1: Two possible mechanisms of cavitation erosion.

Dynamics of the bubble near a triangular prism array

Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

Outline Chapter 7 Waves

Relative Dosimetry. Photons

A study of advection of short wind waves by long waves from surface slope images

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

The Pennsylvania State University. The Graduate School. College of Engineering CHARACTERIZING LASER INDUCED CAVITATION: EFFECTS OF AIR CONTENT,

Investigation of Quasi-detonation Propagation Using Simultaneous Soot Foil and Schlieren Photography

Wave phenomena in a ripple tank

Figure 2: Principle of GPVS and ILIDS.

Properties of luminescence from laser-created bubbles in pressurized water

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

FLUORESCENCE DETERMINATION OF OXYGEN

Review of fundamental photon dosimetry quantities

DETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK

Force & Motion. Objective 6.P.1. 6.P.1 Understand the properties of waves and the wavelike property of energy in earthquakes, light and sound.

ITTC Recommended Procedures and Guidelines

MITIGATE GAS COMBUSTION IN CASE OF INTERNAL ARC

Fabry Perot / PDV Comparison. May 24, 2007

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

An experimental study of internal wave generation through evanescent regions

LASER INDUCED FLUORESCENCE MEASUREMENTS OF CARBON DIOXIDE DISSOLUTION IN WAVE-BREAKING TURBULENCE

The effect of two inclined circular plunging jets on air entrainment in an aeration tank

Quartz etch process to improve etch depth linearity and uniformity using Mask Etcher IV

Chapter 7. SCIIB Pressure Sensor Performance Evaluations: Experiments, Results and Discussions

Dynamics of cavitation bubble induced by 193 nm ArF excimer laser in concentrated sodium chloride solutions

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Proceedings of Meetings on Acoustics

Standard Operating Procedure - First Draft for Review Only- StarWeld Ultra DX

ANZAI AZ-733VI. Respiratory Gating System. since 1976

BIOPAC Blood Flow Monitor

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

High Speed Direct SAD Radiosurgery Beam Scanner

Test Plans & Test Results

Detecting sound wave of bubbles produced in a boiling liquid

Simultaneous two-photon imaging of oxygen and blood flow in deep cerebral vessels. Supplementary figure 1

WAVES: REFRACTION QUESTIONS

CHANGE OF THE BRIGHTNESS TEMPERATURE IN THE MICROWAVE REGION DUE TO THE RELATIVE WIND DIRECTION

HIGH SPATIAL RESOLUTION NEUTRON IMAGING OF INERTIAL FUSION TARGET PLASMAS USING BUBBLE DETECTORS

5 cm. Flash 20 khz. Camera

Analysis of RPC Performance with Different Gas Mixture

Chapter 11 Waves. Waves transport energy without transporting matter. The intensity is the average power per unit area. It is measured in W/m 2.

Field size and depth dependence of wedge factor for internal wedge of dual energy linear accelerator

Optical measurement in carbon nanotubes formation by pulsed laser ablation

The Variation of Muscle Oxygen Consumption With Velocity of Shortening

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Reflection. Reflection- When a wave strikes an object or surface and bounces off.

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Module 5 : Pulse propagation through third order nonlinear optical medium. Lecture 38 : Long distance soliton transmission system.

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

High Resolution Sea Surface Roughness and Wind Speed with Space Lidar (CALIPSO)

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

Look at the simplified diagram of the laser and cross-section of part of a disc. to detector

Acoustical approach to analysis of energy conversions in an oscillating bubble

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Atmospheric Waves James Cayer, Wesley Rondinelli, Kayla Schuster. Abstract

The Nature of Light. Light behaves like a special kind of wave, called an electromagnetic wave.

Trapped Bubble Dynamics in Cryogenic Fluids. Department of Physics and Astronomy, University of California, Los Angeles, CA 90095, USA

Robert Jones Bandage Report

sensors ISSN

Transverse waves cause particles to vibrate perpendicularly to the direction of the wave's motion (e.g. waves on a string, ripples on a pond).

SnapShot IMRT with compensators and FFF beams

AN EXPERIMENTAL INVESTIGATION OF SPILLING BREAKERS

Waves. Name and Surname: Class: L E A R N I N G O U T C O M E. What are waves? Why are waves formed?

EFFECTS OF LASER WINDOW DEGREDATION ON LASER POWER AND DISTRIBUTION IN LASER SINTERING. Ben Fulcher, David K. Leigh

Time Pressure Dispensing

Mid-IR Lasers Market Review and Forecast 2010

Conditions for occurrence of vortex shedding on a large cable stayed bridge. Full scale data from monitoring system

A STUDY ON THE ENTRAPPED AIR BUBBLE IN THE PLASTICIZING PROCESS

BLOCKAGE LOCATION THE PULSE METHOD

Waves can interact with other waves, other objects, or change medium (travel through different substances)

LIFE TIME OF FREAK WAVES: EXPERIMENTAL INVESTIGATIONS

Study of air bubble induced light scattering effect on the image quality in 193 nm immersion lithography

Improved Sputter Depth Resolution in Auger Thin Film Analysis Using In Situ Low Angle Cross-Sections

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Bubble-bubble interactions and wall pressures/temperatures produced by the collapse of a bubble pair near a rigid surface

Numerical simulation of the ALBA s synchrotron cooling system response to pump start-up and shut-down Page 1

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION

EXPERIMENTAL ANALYSIS OF VAPOUR BUBBLE GROWING ON A HEATED SURFACE

Investigation of changes of the refractive index of glass fragments caused by laser ablation

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

INVESTOR PRESENTATION. March 2018

Online gas monitoring by using Raman spectroscopy

Lab 4: Pressure Gradients over a Wing

Properties of waves. Definition:

A Trusted Path to Outstanding Outcomes

Offshore platforms survivability to underwater explosions: part I

Section 1 Types of Waves. Distinguish between mechanical waves and electromagnetic waves.

Airborne Coherent Wind Lidar measurements of vertical and horizontal wind speeds for the investigation of gravity waves

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS AP PHYSICS

Constancy checks of well-type ionization chambers with external-beam radiation units

Transcription:

Short and ultrashort laser pulse induced bubbles on transparent and scattering tissue models. Francisco Pérez-Gutierrez 1, Rodger Evans, Santiago Camacho-Lopez, Guillermo Aguilar 1. 1. University of California, Riverside 9 University Ave. Riverside, CA, 951, USA. Centro de Investigación Científica y Educación Superior de Ensenada Km. 17 Carretera Tijuana-Ensenada, Ensenada, B.C., Mexico ABSTRACT Bubble formation is a well identified phenomenon within short (ns) and ultrashort (fs) laser pulses-aqueous media interactions. Bubble formation might be produced by three different mechanisms: (1) optical breakdown, () rarefraction wave and (3) overheating of the material. Experiments where transparent and scattering tissue models that mimic biological tissue were irradiated with a Q-switched, 53 nm, 5 nanosecond, Nd:YAG and Ti:sapphire femtosecond laser systems. The type of bubble (transient or permanent) and initial bubble diameter were characterized as a function of time as well as the number of pulses and repetition rate at which they were delivered. Threshold fluence for bubble formation in scattering tissue model was also studied. Two types of bubbles were identified depending on the number of pulses and the repetition rate at which they were delivered: transient (type 1) and permanent (type ) bubbles. There is an insignificant difference in the fluence required to form a bubble in transparent tissue models regardless of the depth at which the beam was focused; in contrast, for scattering tissue models, the fluence required to form a bubble in deep positions is significantly higher than that of more superficial beam focus positions. 1. INTRODUCTION Since it was invented, almost 5 years ago, the laser has been widely used for many applications in the field of medicine; both continuous wave (CW) and pulsed lasers are suitable for medical applications 1. The physical mechanisms involved in a laser-matter interaction depend, apart of wavelength, on the pulse intensity, which itself depends on the laser pulse duration; the shorter the pulse the higher the peak intensity. Long laser pulses (ns to ms) couple its energy to the material mainly through the wavelength dependent linear absorption, according to an extinction coefficient (µ t ); most of the energy deposited to the material produces heat and, therefore, the interaction is dominated by heating phenomena. When the laser pulse is very short (below 1ps and down to a few fs), a fast optical and avalanche ionization process dominates the interaction and an expanding plasma is produced with very small amounts of heat transferred to the targeted material. Ultrashort laser-matter interactions are, to a certain degree, wavelengthindependent. While for certain transparent materials like glass there exist two distinctive and definite trends for the damage threshold fluence of the material for laser pulse durations above and below 1ps 3, the frontier between long and ultrashort pulses is not very well established in the context for all materials, particularly biological ones. Long laser pulses (ms to µs) at convenient wavelengths have been incorporated (and sometimes combined with other tools) to laser surgeries where the aim is to produce thermal (by laser heating) treatment of specific chromophores and/or tissue ablation 4. However, there are specific cases where the treatment is not totally successful; as an example, Port Wine Stain (PWS) birthmarks are an abnormal layer of blood vessels 1 to 1µm in diameter localized 1 to 5 µm below the skin surface, that have been treated using long (1 to ms) laser pulses in combination with Cryogen Spray Cooling (CSC). The aim of this treatment is to achieve the temperature at which blood in the vessel coagulates at the same time that the other chromophores in the skin remain undamaged; this treatment has proved successful with large blood vessels (1µm) because they have a long thermal relaxation time (5ms) that allows thermal confinement in the blood vessel, hence achieving the coagulation temperature; in contrast, smaller blood vessels (1µm) have shorter Optical Interactions with Tissue and Cells XVIII, edited by Steven L. Jacques, William P. Roach, Proc. of SPIE Vol. 6435, 6435V, (7) 165-74/7/$18 doi: 1.1117/1.71566 Proc. of SPIE Vol. 6435 6435V-1

thermal relaxation time (5µs), which does not allow sufficient thermal confinement, hence the laser heat produced during the pulse quickly diffuses away to the surrounding tissue before the coagulation temperature is achieved and the blood vessel remains undamaged. A feasible solution for this problem is the use of shorter (nanoseconds, picoseconds to femtoseconds) laser pulses that deliver its energy faster than the thermal relaxation time of those small vessels. We expect to create the conditions for fast laser heating, but also for additional mechanical phenomena triggered by the laser-tissue interaction such as cavitation and shockwaves, which might contribute to the damage and elimination of the very small blood vessels which are difficult to remove by slow laser heating. Several authors have observed that when laser pulses of µs and shorter are focused on aqueous media a bubble is formed 5,6,7,8 ; its diameter and lifetime strongly depend on the laser parameters and material properties, but the conditions for bubble formation must be determined in each individual case. There are three different possible mechanisms for bubble formation: (1) optical breakdown, () rarefraction wave and (3) overheating of the material (Laptko, 6). The bubble formation contributes to material ablation and has found applications in medical procedures such as laser angioplasty and ophthalmic surgeries. In the initial stage of our work, experiments focusing a 5 ns, Nd:YAG laser beam on a vascular lesion artificial model were carried out 9. The threshold fluence for bubble formation was found for different absorption coefficients when the laser beam was focused at a specific depth below the surface; also, the characterization of the bubble diameter as a function of fluence was carried out for several samples with different absorption coefficients, however, only permanent bubbles were studied. In the present work the main objectives are to study the bubble dynamics, i.e., its formation and evolution when a series of pulses at three different repetition frequencies are delivered using a fluence value close to the threshold fluence and, to find the threshold fluence for bubble formation in a scattering tissue model. The last study intends to mimic a highly scattering tissue, like skin. Our experiments were carried out using a 53 nm, Nd:YAG laser, pulse duration of 5 nanoseconds and a 9 femtosecond laser.. MATERIALS AND METHODS.1 Artificial Tissue Models Agar is typically a strong gelling polysaccharide derived from red seaweeds. Agar solutions gel due to the presence of the agarose fraction of the crude agar at common concentrations between.5 and.%. Agar typically needs to be heated above 9 ºC to liquify (melt) and depending on the seaweed source the setting temperature can be between 3 and 45 ºC. As agar gels are mainly conformed by water, they are an excellent material to make artificial tissue phantoms. They may also be combined with other substances to approximate its optical properties to more realistic tissue. In this work, two types of agar phantoms were used. Figure 1 shows the first model, which is made of a single 5 µm thick layer of transparent agar, it was used for the experiments where the bubble dynamics were studied for different number of pulses and repetition rates. Note that the beam was focused 1µm below the surface. Figure shows the second model, which we used to study the bubble formation in a highly scattering medium. It is composed by two layers. The top 54 µm thick layer, the scattering one, is constituted by a mixture of liquid agar gel and 4.8% intralipid; the scattering layer was stacked on top of another layer made of transparent agar gel. For this case the laser beam was focused at 5, 1 and µm deep in the scattering layer. 1 µm 1 µm 5 µm 54 µm Figure 1. 5 µm thickness transparent agar single layer. Figure. Highly scattering agar layer stacked on top of another layer of transparent agar. Proc. of SPIE Vol. 6435 6435V-

. Experimental setup and bubble detection The experimental set up is shown in Figure 3. It can be used in a configuration that includes both a 53 nm, Nd:YAG, 5 nanosecond pulses as well as a 81 nm, Ti:Sapphire, femtosecond as excitation beams and a 63.8 nm HeNe continuous wave laser as probe beam, which are focused on the target with a.5 NA, 8 mm focal length aspherical lens that we will call the microprocessing lens. The energy per pulse delivered on target is monitored either with a properly calibrated photodiode and an oscilloscope or directly with an energy head detector. A CCD camera is used to capture the image of the focused beam on the target; this is done by using an image relay system constituted by the microprocessing lens and the 5mm lens shown in Fig. 3; the light that reflects backwards from the surface is collected by the two lenses projecting an image of the beam waist on to the CCD. This image relay system provides three very useful features to our set up: (1) it requires normal incidence to work so that the sample surface is always perpendicular to the incident beam, and therefore, in the event of a transversal scan of the sample the beam waist of the focusing light stays always at a constant distance from the surface; () it allows fine positioning of the beam waist right on the surface of the sample, and hence at a know depth within the layer, with a resolution of the order of the Rayleigh range of the focusing beam, and; (3) the same image relay system allows to record movies of the bubble formation and evolution inside the agar gel. The bubble formation dynamics is also recorded by use of the HeNe probe beam; the light transmitted through the sample is collected onto a photodiode connected to a data acquisition system. If the bubble is not present, the HeNe light detected by the photodiode produces a constant signal, however, when the bubble forms the initial constant signal drops to a minimum (when the bubbles reaches its maximum diameter) and it recovers back up as the bubble collapses. f = 5 mm f = 8 mm P.D. f = 15 mm f = 5 mm HeNe Sample Blue Filter CCD ETP P.D. Red Filter f = 5 mm Dichroic Mirror Nd:YAG Nd:YAG Fiber light IR Block Polarizer Figure 3. Experimental Setup.3 Image processing Movies of the laser-induced bubbles were taken at 1 frames per second and split into several pictures. The diameter of the bubble was measured for a selected number of pictures using a standard image processing software (ImageJ). Figure 4 shows a typical sequence of photos of the bubble image obtained on the CCD camera. 3 RESULTS AND DISCUSSION 3.1 Bubble dynamics Figures 5 to 9 contain experimental results of laser irradiation of agar gel models with laser pulses of 5ns duration, at a wavelength of 53 nm, on a 5 µm thick transparent layer. The beam was focused 1µm deep in the agar gel layer. The data point plotted at t= represents the diameter of the bubble right after the last pulse. All these experiments were Proc. of SPIE Vol. 6435 6435V-3

carried out with fluence slightly smaller than that for the bubble formation threshold (4 J/cm) for permanent bubbles (.6 ± 9.6 J/cm) such that we could generate the transient bubbles we are interested in; the fluence values shown in figures 5 to 9 correspond to the average fluence value of the total number of pulses applied. Figure 4. Typical sequence of photos that describe how the bubble diameter changes with time. The bubble was obtained by using a single 5 ns (53nm) Nd:YAG laser pulse with fluence of 4.65 J/cm. Upper row (left to right): s,.4 s, 1.6 s, 1.73 s,.4 s 3.6 s, 3.77 s. Lower row (left to right): 4.4 s, 5.6 s, 5.73 s, 6.4 s, 9.7 s, 13.6 s, 15.5 s. Figure 5 shows the time evolution from maximum bubble diameter when a single laser pulse is applied, each curve corresponds to different applied fluences, which are in fact obtained from the inherent fluctuation of the laser system. Except for one case (199.16 J/cm), it was found that the higher the fluence, the bigger the bubble size and that the bigger the bubble, the longer the life-time of the bubble. The case that falls off the typical trend seen for the other cases might be explained by an inhomogeneous agar gel sample. This is also suggested by the fact that for some experiments the bubble was not formed. Figure 5 just shows those cases where the bubble was formed 6 199.16 J/cm 4.64 J/cm 7.39 J/cm 1.13 J/cm 11.4 J/cm 14.7 J/cm 5 4 3 1 4 6 8 1 1 14 Figure 5. Bubble diameter evolution when the bubbles are created by a single 5 ns Nd:YAG laser pulse at 53nm. Figures 6 to 9 contain the evolution of the bubble diameter for bubbles formed by a different number of pulses (1 to 1) at three different repetition rates (1, and 3 Hz). Two types of distinctive bubbles were obtained: Figures 6 and 8 show the typical trend for the type 1 bubbles which are transient and, therefore, they shrink until they fully disappear. The data point with diameter equal to zero is missing in the plot, this is due to the lack of screen resolution to measure the bubble at the exact instant when the bubble collapses completely. Figures 7 and 9 show the type bubbles, which experience some shrinkage at the beginning, but they manage to remain at constant diameter in the agar gel for long periods of time. For the evolution of the type 1 bubbles, it is possible to distinguish three different slopes that indicate Proc. of SPIE Vol. 6435 6435V-4

the rate at which the bubble diameter collapses at different times, while in the case of the type bubbles only two slopes are distinguished after the bubbles have formed. We must point out that in many cases, where several pulses were delivered, the average fluence value is not directly proportional to the initial bubble diameter as it is the case when a single pulse was delivered to the target (Fig. 5), this may be due to the fact that the shown value is the average fluence taken from all the applied pulses, but it is the pulses with higher fluence the ones that dominate the final size of the bubbles. We have cases where the delivery of 1 pulses at and 3 Hz repetition rate resulted in rather too large bubbles, which could not be measured with the current experimental setup. Table 1 summarizes the type of bubble formed in all the experiments according to the number of pulses and the repetition rate and fluence used. It can be clearly seen from table 1 that when the pulses are delivered at 1Hz it takes 1 consecutive pulses for the bubble to start to behave as a type bubble, otherwise, the bubbles behave always type 1 bubbles; while in the case when pulses are delivered at 3 Hz all the bubbles, even those formed with just a couple of pulses, are permanent (type ). 6 6 5 4 3 1 16.5 J/cm 15.6 J/cm 16.5 J/cm 13.7 J/cm 5 4 3 1 9.3 J/cm 33.88 J/cm 8.4 J/cm 4 6 8 1 1 14 Figure 6. Bubble dynamics when 6 pulses at 1 Hz are applied. 4 6 8 1 1 14 Figure 7. Bubble dynamics when 1 pulses at 1 Hz are applied. 6 6 5 4 3 1 13.55 J/cm.4 J/cm J/cm 5 4 3 1 3.3 J/cm 3.3 J/cm 3.97 J/cm 31.14 J/cm 4 6 8 1 1 14 Figure 8. Bubble dynamics when pulses at 1 Hz are applied 4 6 8 1 1 14 Figure 9. Bubble dynamics when pulses at 3 Hz are applied Figures 1 and 11 describe the initial bubble diameter as a function of the number of pulses and the repetition rate at which the pulses were delivered on the target, respectively; error bars were added when calculation of standard deviation was possible from the experimentally acquired data. It can be seen from the plots and the experimental observation (Table 1) that there is a slight tendency of the bubble diameter to increase with the number of pulses at 1Hz Proc. of SPIE Vol. 6435 6435V-5

and with repetition rate. This variation is more significant when 1 pulses are applied; unfortunately, this cannot be plotted in figures 1 and 11 because we were unable to measure those large bubbles, as mentioned above. Frequency Number of pulses 1 Hz Hz 3 Hz 1 1 - - 1 1 3 1 1 6 1 1 NM NM Table 1. Summary of bubble type obtained when different number of pulses at three different repetition rates. The type 1 bubble completely collapses with time; the type bubble remains at a constant diameter in the agar gel. NM: means the bubble was too large to be measured with our current set up. Bubble initial diameter [µm] 9 8 7 6 5 4 3 1 1 3 4 5 6 7 8 9 1 11 Number of pulses 1 Hz Hz 3 Hz Bubble initial diameter [µm] 9 8 7 6 5 4 3 1 1 3 Frequency [Hz] pulses 3 pulses 6 pulses 1 pulses Figure 1. Initial bubble diameter as a function of number of pulses Figure 11. Initial number of pulses as a function of repetition rate. 3. Effect of Scattering. Figures 1 and 13 show plots that compare the laser fluence required to form a bubble with a 5 ns laser pulse at three different depths in transparent and highly scattering agar gel, respectively. From Figure 1, it can be seen that there is insignificant difference in the fluence required to produce the bubble in transparent agar, regardless of the depth at which the beam is being focused; notice also that there is no a defined value for bubble formation threshold fluence, which is indicated by the overlapping of the fluence error bars for the bubble and no-bubble formation events. Figure 13 shows the data for bubble formation in highly scattering agar. It can be seen that in this case too, the laser fluence difference for the bubble and no-bubble formation is very small, although only for the cases where the laser beam is focused at depths of 5 and 1 µm. However, this laser fluence difference becomes larger if the laser beam is focused µm deep.. It is also clear from comparison of Figs. 1 and 13 that the formation of all bubbles in the scattering agar requires larger fluences (on the order of 5% higher fluence) as compared to the formation of bubbles in transparent agar, especially for the µm deep case, where up to 3 times higher fluence is required. Proc. of SPIE Vol. 6435 6435V-6

Fluence [J/cm ] 1 9 8 7 6 5 4 3 1 Bubble No Bubble 4 6 8 1 1 14 16 18 Depth [µm] Fluence [J/cm ] 1 9 8 7 6 5 4 3 1 Bubble No bubble 4 6 8 1 1 14 16 18 Depth [µm] Figure 1. Laser fluence required to form a bubble in transparent agar at different depths. Figure 13. Laser fluence required to form a bubble in scattering agar at different depths. 3.3 Irradiation with femtosecond laser pulses. Similar experiments were carried out irradiating transparent agar gels with bursts from Ti:Sapphire femtosecond laser pulses positioning the focal point 1µm below the gel surface, the variation of the bubble size with time is shown in Figure 14; the maximum energy used for these experiments was the maximum energy that was available with the laser system at the moment of the experiment. The fluence value shown in Figure 14 for each curve is the average fluence of two burst that produced the bubble. It should be noticed that the initial size of the bubbles is half of the maximum size obtained with nanosecond laser pulses and that all of these bubbles collapse within seconds, in contrast with those produced by nanosecond laser pulses. No permanent bubbles were observed. 6 Bubble size [µm] 5 4 3 1 64J/cm 1 J/cm 148 J/cm 1 1 Figure 14. Bubble dynamics when bursts of femtosecond laser pulses are applied to transparent agar gels positioning the beam s waist 1 below the gel surface. 4 CONCLUSIONS The type of bubble (transient or permanent) that can be produced by single 5 ns laser pulses is strongly dependent on the fluence of the pulse as shown in a previous work; however, for fluences under the threshold for permanent bubble formation, the type of bubble that can be formed depends on the number of pulses and the frequency at which these are Proc. of SPIE Vol. 6435 6435V-7

delivered. The fluence needed to form a bubble in highly scattering agar gel is ~5% more as that needed in clear agar gel at 5 and 1 µm deep. However, at µm, at least 3 times higher fluence is required. Bubbles produced with femtosecond laser pulses with the fluences available in the laboratory were always transient and half the initial size than those produced with nanosecond laser pulses. AKNOWLEGMENTS 1. UCMEXUS-CONACyT Collaborative Research Grant, Studies of ultrashort laser pulse interaction with vascular and pigmented dermatologic lesions with Dr. Santiago Camacho, CICESE, 7/1/4-8/3/6.. UCR-Mexico Initiatives, Effects of ultrashort laser pulse irradiation on melanocyte viability, UCMEXUS, 9/1/4-4/3/6. 3. NSF-SGER, Thermo-mechanical interactions of ultrashort laser pulses with subsurface targets of tissue models, NSF 7/1/6-6/3/7. Agency Award No: CTS-6966. 4. CONACyT and UCMEXUS scholarship for graduate studies. 5. Mr. Gerardo Romo-Cardenas and Mrs. Alejandra Mina-Rosales for their collaboration in this work. REFERENCES 1. Loo W.J., et al; Recent advances in Laser therapy for the Treatment of Cutaneous Vascular Disorders, Lasers Med Sci, 17, 9-1,.. Venugopalan Vasan, et al. Role of Laser-Induced Plasma formation in Pulses Cellular Microsurgery and Micromanipulation, Physical Review Letters, 88, 7, 88-7,. 3. D. Du, et al; Laser-Induced Breakdown by Impact ionization in SiO With Pulse Widths from 7 ns to 15 fs ; Appl. Phys. Lett., 64, 371-373, 1994. 4. Anderson R.R and Parish J.S., Selective Photothermolysis, precise microsurgery by selective absorption of pulsed radiation, Sience,, 54-57, 1983. 5. Schuele Georg, et al.; RPE Damage threshold and Mechanisms for Laser Exposure in Microsecond-to- Millisecond Time Regimen, Investigative Ophthalmology & Visual Science; 46, 714-719, 1995. 6. Neumann Jörg, et al; Boiling Nucleation on Melanosomes and Microbeads Transiently Heated by Nanosecond and Microsecond Laser Pulses, Journal of Biomedical Optics, 1(), 41-1-41-1, 5. 7. Ohl Claus-Dieter, et al; Bubble Dynamics, Shock Waves and Sonoluminescence, Phil. Trans. R. Soc. Lond. A 357, 69-94, 1999. 8. Laptko D. Laser-Induced Bubbles in Living Cells. Lasers in Surgery and Medicine, 38, 4-48, 6. 9. Romo-Cárdenas Gerardo. et al, Estudio de efectos foto-inducidos en modelos de tejido-biológico usando láser de nanosegundos ; XVIII Congreso Nacional de Físca / XVIII Reunión Anual de Óptica; Sociedad Mexicana de Fisica; Guadalajara, México; 5. Proc. of SPIE Vol. 6435 6435V-8