Modular Pressure Transmitter Pf

Similar documents
L3 Pressure and Level transmitter

Pressure Transmitter P41

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR

Ceramic Pressure Sensor

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

ED 701 Hygenic Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

How to specify a product. Process Sensors and Mechanical Instruments

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

OPTIBAR P 1010 C Technical Datasheet

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

ATM.ECO - Analog Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Pressure Measurement Single-range transmitters for general applications

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Precision pressure sensor Basic version Model CPT6020

ATM.ECO/IS - Analog Transmitter with Temperature compensation

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Differential Pressure Transmiter

9700 Transmitter Submersible hydrostatic level transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

3.0 Pressure Transmitter Selection

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Programmable pressure and temperature transmitters PTM/RS485

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

ATM.1ST/Ex - High Precision Transmitter

MANUAL KPS Pressure Control Valve

GEMS SENSORS & CONTROLS

High-performance submersible pressure transmitter For level measurement Model LH-20

DTG - LCD Digital Temperature Gauge USER MANUAL

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Expert Hydrostatic Level Transmitters

[Instruments for vacuum measurement, checking and adjustment] 3

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Pressure transmitter PASCAL Ci4

Programmable pressure and temperature transmitters PTM/RS485

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

BS12N Piezoresistive OEM Pressure Sensor

SITRANS P measuring instruments for pressure

Pneumatic high-pressure controller Model CPC7000

Parametrable / Programmable Pressure Transmitter

Orifice Plate Flow Meter

High-performance submersible pressure transmitter For level measurement Model LH-10

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

BS12 Piezoresistive OEM Pressure Sensor

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

High-performance submersible pressure transmitter For level measurement Model LH-20

ATM - Analog Pressure Transmitter

SX150A. Features. Typical Applications. Description

Level switches Series LD Vibrating fork level switch for liquids and solids

Instruction Manual Differential Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

EPP4 Pressure Regulator Basic G 1/4"

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

86BSD Backside Digital Output

Operating instructions Pressure sensor. PN422x / / 2013

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Level switches Series LD Vibrating fork level switch for liquids and solids

Tank Blanketing Pressure Regulators RHPS Series

C-Flow Coriolis Mass Flow Meters

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Pneumatic high-pressure controller Model CPC7000

Pressure transmitters EMP 2

2600T Series Pressure Transmitter

Programmable Submersible Level Transmitters

Electro-Pneumatic Converter YT-940 SERIES

ATM/Ex - Analog Pressure Transmitter

P499 Heavy Duty Pressure Transducer

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Pressure Transmitters 36 F-27839

PRODUCT CATALOGUE DIGITAL GAUGES

Pressure Measurement Single-range transmitters for general applications

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

P900. P900, Datenblatt Seite 1 DESCRIPTION

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Transcription:

arch 2006 1 Product Information Pf odular Pressure Transmitter Pf f o o d Range of applications Authorizations Pressure measurement in pipes and vessels High Temperature applications up to 177 C (350 F) permanent Application xamples TYP L Sanitary pressure monitoring for breweries, dairies and food & beverage production Pressure sensor Pf Hygienic design / Process Connection Front-flush, hygienic and easy sterilizable installation by sleeve Z-352 or build-in system HG-.../1" Conforming to 3-A Sanitary Standard 74-05 with Tri-Clamp DIRCTadapt HDG compilant hygienic design with CLANadapt process connection CIP-/ SIP-cleaning up to 177 C / 350 F Product contacting materials compliant to FDA Sensor and product contact surfaces made of stainless steel Version with fixed Tri-Clamp adaptor Additional process connections in combination with CLANadapt: diary flange (DIN 11851), Varivent, APV, DRD et al. features Unique design and fully modular components Components may be economically purchased and individually integrated Lower inventory cost for critical sensors odules may be stocked and interchanged to meet any need xtremely durable at continuous temperatures up to 177 C / 350 F asy to operate, adjustments without additional tools Self diagnostics ensure that sensor is performing optimally Available with absolute and relative measuring cell (vacuum proof) Developed to excel in the harshest environments Air tight sealing eliminates internal condensation (patent pending) Pressure sensor Pf options / Accessories Wide offering of standard pressure ranges Customer specified ranges available Waterproof prefabricated cable for 12 connector easuring Principle of the Pressure Sensor This unit utilizes an internal piezoelectric transducer to convert the process measurement into a corresponding mv signal. The mv signal then passes through custom linearization and conditioning circuitry. The resulting signal is an industry standard 4...20 ma. This ma signal is factory set over the specified range of the unit. With relative pressure sensors, the back of the diaphragm is vented, i.e. this sensor measures the gauge pressure and/or vacuum relative to the atmospheric pressure. With an absolute pressure sensor the measurement is relative to a perfect theoretical vacuum. I.e. the signal will vary with the ambient atmospheric air pressure. NGL SSTCHNIK GBH Raiffeisenweg 7 87743 gg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720

f o o d Specification 2 Specification easuring range URL [bar] easuring range URL [psi] Relative Absolute Relative Absolute 0...2 / 3 /4 / 6 /7 / 10 / 20 / 35 / 70-1...1 / 2.5 / 3 / 4 / 7 0...2 / 3 / 4 / 6 / 7 /10 / 20 / 35 0...30 / 50 / 60 / 99 / 100 / 150 / 160 / 200 / 300 / 500 / 1000 30 mmhg/0, 30 mmhg/0...15 / 30 / 60 / 100 / 200 0...30 / 50 / 60 / 100 / 150 / 160 / 200 / 300 / 500 Turndown max. 10:1 of upper range value (see also measurement accuracy) Overpressure strength Factor 1.5 x nominal pressure of measuring element up to 35 bar/500 psi 1.1 x nominal pressure of measuring element 70 bar / 1000 psi easurement accuracy Turndown to 5:1 Turndown over 5:1 Repeatability Long-term stability 0.10 % in calibrated measuring range 0.15 % in calibrated measuring range 0.05 % 0.2 % URL every 2 years Temperature effect Temperature range Response time Sample rate aterials Process connection lectric connection Protection class Auxiliary voltage Process Ambient Process Ambient Connection head etal cover Plastic cover Threaded connector Wetted parts Diaphragm Diaphragm seal/oil filling Cable gland Plug-in connection < 12.5 mbar /10 C (0.1 psi / 10 F) typical < 12.5 mbar /10 C (0.1 psi / 10 F) typical -18...177 C (0...350 F) at ambient temp. up to 60 C (140 F) -18...165 C (0...330 F) at ambient temp. up to 71 C (160 F) 0...71 C (32...169 F) < 0.1 seconds < 0.05 seconds Stainless steel, AISI 304 (1.4301), R a 0.8 µm (32 microinch) Stainless steel, AISI 304 (1.4301), R a 0.8 µm (32 microinch) Polycarbonate Stainless steel, AISI 304 (1.4301), R a 0.8 µm (32 microinch) Stainless steel, AISI 316L, R a 0.64 µm (25 microinch) Stainless steel, AISI 316L, R a 0.64 µm (25 microinch) edical white oil / mineral oil / paraffin oil FDA approval number 21CFR172.878, 21CFR178.3620, 21CFR573.680 Neobee 20 (optional) G1" hygienic, CP fitting, IDF 38 mm / 51 mm (female), Tri-Clamp 3/4"...2" 16x1.5 12 plug, 5-pin, 1.4305 (option) IP 67 (with cable fitting) / NA 4X IP 69 K (with plug-in connection) 18...36 V DC Output Current loop analog 4...20 ma Burden see separate graph on page 3 Tightening torque Weight For assembly all PFS components 27 Nm (20 ft-lbs) approx. 780 g

3 Installation Advice f o o d Burden 1000 900 Total Loop Resistance [Ω] 800 700 600 500 400 300 200 100 0 18 20 22 24 26 28 30 32 34 36 Loop Power Supply Voltage [V DC] TOTAL LOOP RSISTANC POWR SUPPLY PR SPCS INPUT LOOP + LOOP - + + SIGNAL RCIVR OPTIONAL A ATR (4-20 ma DC) SHILD GROUND (ON POINT ONLY) Conditions for a measuring point according to 3-A Sanitary Standard 74-05 The PF sonsors with Tri-Clamp fitting conforming to the 3-A Sanitary Standard. The sensors are designed for CIP-/ SIP-cleaning. aximum 177 C / 120 minutes. Only with 3-A conforming Tri-Clamp connection. ounting position, self draining and the position of the leackage hole must be in accordance to current 3-A Sanitary Standard. xploded view of functional components 1: Cap (including two O-rings) 2: Puck 3: nclosure 4: 12 Quick disconnect (including two O-rings) 5: Stem (including two O-rings) 1 2 3 4 5

f o o d Dimensional Drawings 4 Dimensional drawing horizontal orientation 91 mm (3.6 ) Dimensional drawing vertical orientation 91 mm (3.6 ) 167 mm (6.6 ) 167 mm (6.6 ) Dimensional drawing CLANadapt horizontal orientation 91 mm (3.6 ) Dimensional drawing CLANadapt vertical orientation 91 mm (3.6 ) 160 mm (6.3 ) 160 mm (6.3 ) echanical Connection / Installation Pay attention to the maximum tightening torque of 20 Nm if using Negele CLANadapt system!

5 lectrical Connection Advices f o o d Conventional Usage Not suitable for applications in explosive areas. Not suitable for applications in security-relevant equipments (SIL). lectrical connection with cable gland lectrical connection with 12-plug X UP DOWN NU + _ LOOP SNSOR PLC Configuration 12-plug 1: + supply +24 V DC 2: - output 4...20 ma 3: not connected 4: not connected 5: not connected 4...20 ma 2-wire current loop aintenance rror Codes rror Code Category Customer Action No visible code, 3.8 ma output 100 101 Communication Incompatible Range Incompatible Range/ range changed Check Stem ribbon cable connection to puck, power cycle 1. Reset rror 2. Reconfigure puck to a range compatible with the stem 3. power cycle 1. Reset rror 2. Reconfigure puck to a range compatible with the stem 3. power cycle 300 Stem Data Corruption Replace Stem 301 Stem Data Corruption Replace Stem 302 Stem Data Corruption Replace Stem 304 Stem Data Corruption Replace Stem 405 Puck Data Corruption Replace Puck 406 Puck Data Corruption Replace Puck 407 Puck Data Corruption Replace Puck 500 Communication Check Stem ribbon cable connection to puck, power cycle 501 Stem Data Corruption Replace Stem 502 Stem Data Corruption Replace Stem 503 Stem Data Corruption Replace Stem 504 Stem Data Corruption Replace Stem 505 Insufficient loop voltage Check if loop voltage is at least 18 V, provide correct voltage then power cycle 600 Puck Data Corruption Replace Puck 602 Stem Configuration rror Reset rror and power cycle and if error is persistent replace Stem 603 Stem Configuration rror Reset rror and power cycle and if error is persistent replace Stem 700 Internal System Failure Reset rror and power cycle and if error is persistent replace puck 701 Internal System Failure Reset rror and power cycle and if error is persistent replace puck 702 Internal System Failure Reset rror and power cycle and if error is persistent replace puck

f o o d Installation 6 odular sensor principle The PF pressure sensor has a modular design. It can be purchased in separate components and assembled as required by the customer. It is also available as a fully assembled sensor. In both cases, the user can check or change the following settings. The components and sensors are delivered according to the specifications (ranges and units) stated on the type label. These values can be checked and changed by the user in the following menu. This is accomplished using two operating buttons (with a total of 4 actuation possibilities) and a 4-digit segment display. View of electronics with open cover Configuration submenu damping output call up see page 7 Damping Delay [ms] U UP X 0 100 1 1000 D DOWN NU 2 2000 3 3000 4 4000 xplenation of symbols used in menu structure Tip on button for short time L Hold button for minimum 2 seconds Tip on button for short time L Hold button for minimum 2 seconds U Tip on button U for short time U L Hold button U for minimum 2 seconds D Tip on button D for short time D L Hold button D for minimum 2 seconds 5 5000 6 6000 7 7000 8 8000 9 9000 10 10000 Starting sequence Power on device LD-test all segments and points lighted Revision number is displayed Pressure unit e. g. BAR or PSI for relative version Upper range value e. g. 12.0 BAR Self-test, display differs acc. to Display VALU Basic menu / RUN OD

7 Installation food Display of submenu/settings ode / Basic menu RUN OD LD Indicator Button/switch Submenu operating level Select: U or D Select: U or D Clear error One touch zero (zero adjustment) Display pressure or current value Display actual current or pressure value or error code if an error occured DL DL Setting Clear error + L One Touch Zero Display pressure value for 2 seconds (PVAL) if display current (CVAL) is selected. U D L SNSOR CONFIG OD Display VALU + UL D / Toggle display CVAL / PVAL U D Units / D / U PRSSUR RANG LRV: Lower range value Actual pressure value BAR / PSI Toggle unit U Output Actual current value (ma) PSI relative / BAR relative PSI absolute / BAR absolute Assignment of current value at output to measuring range 4...20 -> 4 ma = measuring range min 20 ma = max measuring range 20...4 -> 20 ma = measuring range min 4 ma = max measuring range Change value, D / U Display of present setting e.g. 50 PRSSUR RANG URV: Upper range value Change value, D / U Display of present setting e.g. 50 Output Damping Factory configuration reset CALIBRATION OD at changing is not possible (vacuum range). D / U Display of present setting e.g. 0...10 Display no D / U use U or D to set desired value. At the units BAR / PSI were changed. Change value, see table on page 6. Change to YS -> Reset to factory setting

f o o d Order code for measuring range 8 Cleaning / aintenance In case of using pressure washers, dont t point nozzle directly to electrical connections! Reshipment Sensors shall be clean and must not be contaminated with dangerous media! Note the advice for cleaning! Use suitable transport packaging only to avoid damage of the equipment! Transport / Storage No outdoor storage Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage temperature -55...+90 C Relative humidity max. 95 % Standards and Guidelines You have to comply with applicable regulations and directives. Advice to Conformity Applicable guidelines: lectromagnetic compatibility 2004/108/C The accordance with applicable C-guidelines is confirmed with C-labeling of the device. You have to guarantee the compliance of all guidelines applicable for the entire equipement. Disposal This instrument is not subject to the W directive 2002/96/C and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. Possible presettings of the measurement range Order number PSI Suitable for sensor type (see Order number) Order number BAR Suitable for sensor type (see Order number) A (absolute) C (relative) A (absolute) C (relative) 025 30Hg/0 x 251-1...1 x 028 30Hg/0/15 x 286-1...2.5 x 029 30Hg/0/30 x 217-1 3 x 031 30Hg/0/60 x 056-1 4 x 032 30Hg/0/100 x 304-1 7 x 314 30Hg/0/200 x 057 0 2 x x 066 0 30 x 235 0 3 x x 068 0 50 x x 192 0 4 x x 069 0 60 x x 060 0 6 x x 070 0 99 x x 309 0 7 x x 071 0 100 x x 061 0 10 x x 073 0 150 x x 065 0 20 x x 074 0 160 x x 224 0 35 x x 075 0 200 x x 206 0 70 x 077 0 300 x x 081 0 500 x x 084 0 1000 x x 000 (Field calibration) 999 (Factory setting acc. to customer specifications)

9 order code f o o d order code of fully assembled sensor Pf (odular pressure sensor, food) S1 (Sensor neck, food and beverages) aximum upper range value 966 (30 psi / 2 bar) 971 (100 psi / 7 bar) 981 (500 psi / 35 bar) 984 (1000 psi / 70 bar) Sensor type A C (Absolute) (Relative, vacuum-proof) Process connection 160 182 059 002 003 004 005 123 129 131 (Flexible thread G1", hygienic CLANadapt) (Fixed thread G1" hygienic CLANadapt) (1.5" NPT) (3/4" Tri-Clamp) (1" Tri-Clamp) (1.5" Tri-Clamp) (2" Tri-Clamp) (CP fitting) (IDF 38 mm female) (IDF 51 mm female) Actuating fill 1 5 (edical-grade white oil/fda-approved) (Neobee 20) aterial membrane A (Stainless steel 316L) 00 (Fixed character) Certificates A (No certificate) B (3.1 aterial and 2.1 Certificate) nclosure 2A 3A (SS head with measuring electronics and plastic cover) (SS head with measuring electronics and stainless steel cover) Unit of measure P B (PSI) (BAR) easuring range XXX (See measuring range table, page 8) 0 (Fixed character) lectrical connection A (12 connector) C (Cable fitting 16 x 1.5) nclosure orientation 1 2 (Vertical) (Horizontal) Certificates A B C d (No certificate) (3.1 aterial and 2.1 Certificate) (3.1 aterial and accuracy) (2.1 Certificate) 64 (Fixed character) Pf S1 966 C 160 1 A 00 A 2A P 068 0 A 1 A 64

f o o d order Code odular Components 1 0 order number of measuring electronics without stainless steel enclosure 1A (easuring electronics without stainless steel enclosure) Unit of measure P (PSI) B (BAR) 0 (Field calibrated) easuring range 000 (without preset of measuring range) XXX (See measuring range table, page 8) 0 (Fixed character) lectrical connection 0 (easuring electronics only) nclosure orientation 0 (easuring electronics only) Certificates A (No certificate) d (2.1 Certificate) 64 (Fixed character) 1A P 066 0 0 0 A 64 order number of measuring electronics with stainless steel enclosure 2A 3A (easuring electronics with stainless steel enclosure and plastic cover) (easuring electronics with stainless steel enclosure and stainless steel cover) Unit of measure P (PSI) B (BAR) easuring range 000 (without preset of measuring range) XXX (See measuring range table, page 8) 0 (Fixed character) lectrical connection A (12 connector) C (Cable fitting 16 x 1.5) nclosure orientation 1 (Vertical) 2 (Horizontal) Certificates A (No certificate) d (2.1 Certificate) 64 (Fixed character) 2A P 066 0 A 1 A 64

1 1 order Code odular Components f o o d order code of sensor neck S1 (Sensor neck, food and beverages) aximum measuring range end value 966 (30 psi / 2 bar) 971 (100 psi / 7 bar) 981 (500 psi / 35 bar) 984 (1000 psi / 70 bar) Sensor type A (Absolute) C (Relative, vacuum-proof) Process connection 160 (Flexible thread G1", hygienic CLANadapt) 182 (Fixed thread G1" hygienic CLANadapt) 059 (1.5" NPT) 002 (3/4" Tri-Clamp) 003 (1" Tri-Clamp) 004 (1.5" Tri-Clamp) 005 (2" Tri-Clamp) 123 (CP fitting) 129 (IDF 38 mm female) 131 (IDF 51 mm female) Actuating fill 1 (edical white oil / mineral oil) 5 (Neobee 20) aterial membrane A (Stainless steel 316L) 00 (Fixed character) Certificates A (No certificate) B (3.1 aterial and 2.1 Certificate) S1 966 A 160 1 A 00 A

f o o d order Code Single Components 1 2 order number of individual components figure Part order number lectronics See order number of measuring electronics without a stainless steel housing on page 10 Wire cover 56741B0064 nclosure w/o cap 56327S0064 Stainless steel cap with seal 5632900001 Plastic cap with seal 5632800001 12 connector SP56726A0002 Cable gland 16x1.5 SP5633100000 O-ring kit (6 rings for complete sensor) 563300001 25.10.12 / 1.2 / U / at-ac.de NGL SSTCHNIK GBH Raiffeisenweg 7 87743 gg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720