Installation, commissioning and servicing instructions

Similar documents
Installation, commissioning and servicing instructions

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Scald Protection Three-Way Thermostatic Mixing Valve

Scald Protection 3-Way Thermostatic Mixing Valve

Installation, commissioning and servicing instructions. General

Installation, commissioning and servicing instructions

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

Intamix Thermostatic Mixing Valve

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

Deluge Optimo Shower valve and kit 10032CP

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

INSTALLATION, OPERATING AND MAINTENANCE GUIDE FOR EXPOSED AND CONCEALED MODELS MODERN, TRADITIONAL AND MINIMALISTIC

Installation, commissioning and servicing instructions

553 Series.

Installation Instructions and User Guide

Installation, commissioning and servicing instructions

INSTALLATION INSTRUCTIONS

PEG402, PEG402UA & PEG402UAX TMV3 / TMV2 Combined

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Twin & Triple Control Concealed Thermostatic Shower Valve

TMV20 THERMOSTATIC MIXING VALVE

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR

Installation Instructions and User Guide

Pre-adjustable pressure reducing valves with self-contained cartridge

Self-help Temperature Adjustment

INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS

AQUABLEND 2000 THERMOSTATIC MIXING VALVE

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

High Performance BSP Dial Up Pattern Pressure Reducing Valve

In Line Thermostatic Controller. Copper x Copper

THERMOSTATIC MIXING VALVES

Pressure independent control valve (PICV) FLOWMATIC

AQUABLEND MM THERMOSTATIC MIXING VALVE

AQUABLEND 1500 THERMOSTATIC MIXING VALVE WITH THERMAL FLUSH

5213 Series INSTALLATION AND COMMISSIONING MANUAL

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

PRODUCT MANUAL IMPORTANT

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TMV3 Requirements IMPORTANT Installer:

Issue date: July 2012 Issue 1

valves Total Control.

2-port seat valves PN25 with externally threaded connections

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Bar valve with fixed shower head Installation guide

k valve ½ (15) ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF installation guide aylesbury For valve sizes (DN):

Materials : Brass body dezincification-resistant up to DN1 1/4

DS05C,D,G Dial Set Pressure Regulating Valves

KAX VALVE ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF INSTALLATION GUIDE AYLESBURY FOR VALVE SIZES (DN):

Art PRESSURE REDUCER

WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER!

Manual Actuated Boiler Blowdown Valves

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT

Atmos Low Pressure Thermostatic Bar Mixer Valve

D05 Pressure Regulating Valves

Installation, operation & maintenance manual - original version

CALEFFI. Ball zone valves. series /03 GB

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

GN 2 CONSTANT FLOW REGULATORS. GUIDANCE NOTE GN 2 Constant Flow Regulators. Page 1 COMMISSIONING SPECIALISTS ASSOCIATION.

Rada-Presto TF2020 and TF2020S

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

WHEATLEY Series 500 Swing Check Valve

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

ACCREDITED. Function. series 5360/

Pressure Independent Control Series

CAST IRON SAFETY VALVE TYPE 6301

Issue date: April 2017

SV60 Safety valves. for use with steam, gas and liquids

WW-720. Pressure Reducing Control Valve

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

Pressure reducing valves

Bermad Pressure Reducing. Model: 42T

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

System Pressure Manager Standard & System Pressure Manager Plus

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

D05T Compact Design Pressure Regulating Valves

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Part 3.0. Storage Tanks

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

320 c PRODUCT MANUAL IMPORTANT

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Ballorex Dynamic Description. Versions. Benefits. Balancing

LRS(H)4 Pressure-Reducing Regulator User Manual

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

Pressure Regulator. Instructions for Use

Transcription:

38512.08 Tempering valve www.caleffi.com 5213 series Copyright 2018 Caleffi Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature of mixed hot and cold water even when variations occurr in the water supply conditions. The Caleffi 5213 series has been specifically designed and manufactured to meet the requirements of AS 4032.2:2005 Tempering valves and end-ofline temperature actuated devices. AS 4032.2 C of C 02466 Product Code 521312 AUS: 15 mm (1/2 ) 521319 AUS: 20 mm (3/4 ) 521325 AUS: 25 mm (1 ) Valves are supplied with in-line strainers and check valves plus union at the inlets. The end connections are male compression.

Technical Data Materials: - Valve body: DZR alloy EN 12165 CW602N - Regulating spindle: DZR alloy EN 12165 CW602N - Internal shutter: PPO - Sealing elements: EPDM - Cap: ABS Temperature adjustment range: 30 50 C (55 C only under supervision and not within requirements of AS3500 and AS4032.2) 20 50 C (25 45 C within the scope of AS4032.2)(521325 AUS) Temperature set: Must be commissioned on site to achieve desired temperature Temperature control: ±3 C Minimum cold inlet temperature: 5 C Maximum cold inlet temperature (compatible with temperature adjustment range): 30 C 20 C (521325 AUS) Minimum hot inlet temperature: 55 C Maximum hot inlet temperature: 85 C Maximum working pressure (static): 1400 kpa Maximum working pressure (dynamic): 500 kpa Minimum working pressure (dynamic): 20 kpa Maximum unbalanced dynamic supply (hot/cold or cold/hot): 6:1 2:1 (521325 AUS) Minimum temperature differential between hot water inlet and mixed water outlet to ensure thermal shutoff function: 10 C Minimum temperature differential between mixed water outlet and cold water inlet to ensure stable operation: 5 C Minimum flow rate for stable operation: 4 l/min 6 l/min (521325 AUS) Dimensions B C B Code 521312 521319 521325 AUS AUS AUS A Ø 15 Ø 20 Ø 25 D E F A AS 4032.2 C of C 02466 A B C D E F 62,5 69 125 138 91 126,5 48,5 84 42,5 42,5 85,5 171 166,5 102,5 64 D* E* A * Only for 521319 AUS and 521325 AUS 2

Operation A tempering valve mixes hot and cold water in such a way as to maintain the set temperature of the mixed water at the outlet. A thermostatic element is fully immersed into the mixed water. It then contracts or expands causing movement of the piston, closing either the hot or cold inlets, thus regulating the flow of water entering the valve. If there are variations of temperature or pressure at the inlets, the internal element automatically reacts attempting to restore the original temperature setting. Thermal shutoff In the event of a failure of the hot or cold supply, the piston will shut off, stopping water discharging from the mixed water outlet. The Caleffi valve requires a minimum temperature differential from hot inlet to mixed water outlet of 10 C to ensure the correct operation of the thermal shutoff feature. COLD HOT MIXED 3

Flow rate graph Pressure Drop - kpa Flow rate - Litres per minute Code Ø (mm) Kv (m 3 /h) 521312 AUS 15 1,5 521319 AUS 20 1,7 521325 AUS 25 4,2 Flow rate Caleffi series 5213 series tempering valves are designed to be typically installed at the hot water storage heater. In order to ensure a set temperature, the tempering valve must have a minimum flow rate of 4 l/min. The size DN 25 is also suitable for use with emergency showers applications. The system must be sized taking into account the current legislation with regard to the nominal flow rate of each outlet. The reference is AS/NZS 3500.1 Table 3.1. 4

Exploded diagram 1 CAP 2 LOCKING NUT 3 TEMPERATURE ADJUSTMENT SPINDLE 4 VALVE BODY 5 6 7 8 9 GASKET UNION NUT INSERT CHECK VALVE INSERT STRAINER TAIL PIECE BODY 1 2 3 4 5 6 7 8 9 A 5

Installation The Caleffi 5213 series must be installed by a licensed plumber. The installer has a duty of care to ensure that all aspects of the installation comply with the AS/NZS 3500, appropriate Codes of Practice, local regulations and following these instructions. Prior to the installation of the Caleffi 5213 series valve, the system must be checked to ensure that the system operating conditions fall within the recommended operating range of the valve, i.e. verify supply temperatures, supply pressures, risk assessments, etc. The supply system into which the Caleffi 5213 series is to be installed must be thoroughly flushed and cleaned to remove any debris which may accumulate during the installation. Failure to remove any debris will affect the performance and the manufacturer s warranty on the product. In areas that are subject to high levels of aggressive water, provision must be made to treat the water prior to it entering the valve. The valve can be installed in any position, whether vertical or horizontal. To allow for maintenance, it is essential that access to the valve and fittings is not impeded. It is essential that when the installation is designed and/or installed, all current legislation is noted, e.g. the maximum distance from the outlet of the valve to any terminal fitting. The connecting hot and cold water supplies must be connected to the valve strictly in accordance with the indications on the body of the valve. The inlets of the valves are clearly marked with the letter H (Hot) and C (Cold). The outlet is marked with the word MIX. Where one or both the incoming supply pressures are excessive, a Caleffi pressure reducing valve should be fitted to reduce the pressure(s) to within the limits as quoted previously. Any tempering valve must be installed with isolating valves, line strainers and check valves at both the inlets. Isolating valves are required so that the water supply to the valve can be isolated in the event that servicing is required. Strainers are required to prevent debris from entering the valve. Check valves are required at both hot and cold inlets to prevent crossconnection. The Caleffi 5213 series is supplied complete with line strainers and check valves at the hot and cold inlets. Isolation valves must be fitted at the inlets. The temperature of the hot water at the inlet must be 10 C higher than the set mixed water outlet to ensure the Caleffi 5213 series thermal shutoff function. The pipework must not be used to support the weight of the valve. If the valve is not installed correctly then it will not function correctly and may put the user in danger. 6

Installation diagram MIXED OUTLET HOT SUPPLY COLD SUPPLY T AS 4032.2 C of C 02466 Temperature limiting valve (if required) Pressure reducing valve (if required) Isolating valve Strainer & check valve Strainer & check valve Isolating valve Pressure reducing valve (if required) Application diagrams System without recirculation HOT WATER STORAGE HEATER AS 4032.2 C of C 02466 MAINS SUPPLY System with recirculation HOT WATER STORAGE HEATER AS 4032.2 C of C 02466 MAINS SUPPLY 7

Commissioning Upon completion of the installation, the valve should be tested and commissioned in accordance with AS 4032.3 as per the procedure outlined below or as specified by the local authority. The following instructions should be read and understood prior to commissioning the Caleffi 5213 series valve. If, under any circumstances, there are aspects of the installation/system which do not comply with our requirements or the specifications as laid down, the valve must not be put into service until the installation/system does comply. 1) Ensure that the system is throughly clean and free from debris prior to commissioning the thermostatic mixing valve. 2) We recommend that the commissioning of temperatures are carried out using a suitably calibrated and accurate digital thermometer. The valve is commissioned by measuring the mixed water temperature at the outlet. 3) The temperature of the mixed water supplied to an outlet primarily for personal hygiene purposes shall be in accordance with the requirements of AS/NZS 3500. 4) The temperature at the outlet of each valve must be set taking into consideration any fluctuations which may occurr within the system due to simultaneous demand. 5) Once the supply temperatures are stabilised and the normal operating conditions are established, the valve can be commissioned. The temperature setting can be adjusted by removing the cap from the valve body and adjusting the temperature adjustment spindle. We suggest that the following sequence is followed when commissioning the valve. a) Set the mixed water discharge temperature to the required temperature. b)measure and record the temperature of hot and cold water supplies at the connections to the valve. c) Measure and record the temperature of the water discharging from the largest and smallest volume draw off points. d)perform the thermal shutoff test. Isolate the cold water supply to the Caleffi valve and monitor the mixed water temperature. The outlet flow should quickly cease. e) Measure and record the maximum mixed water temperature. The temperature should not exceed that allowed by the applicable standard or code of practice for each state. f) Restore the cold water supply to the valve and measure and record the outlet temperature after the mixed water temperature has stabilised. The final temperature found during this test should not exceed the permitted values +3 C. 6) Once the desired temperature has been reached, the temperature adjustment spindle can be locked in position using the locking nut supplied. 7) Once the desired temperature is established, secure the cap back on to the valve to prevent tampering by unauthorised persons. We recommend that the above information is recorded in a Commissioning Report and updated on a Service Report when any work is carried out on the valve. 8

Temperature adjustment 1 Remove the cap 2 Direction of temperature adjustment 3 Temperature adjustment 4 Lock adjustment spindle with locking nut 9

Maintenance Tests should be carried out periodically to monitor the performance of the valve in accordance with AS 4032.3. Deterioration in performance can indicate the need for varying water supply conditions and/or maintenance or replacement of the valve. If, during these tests, the mixed water temperature has changed significantly from the previous test results, record the change before re-adjusting the mixed water temperature. If the final mixed water temperature is greater than the permitted values, we recommend that the details quoted in Installation and Commissioning sections are verified and that service work is required. We recommend that the following checks are carried out at least every 12 months, or more frequently if required, to ensure that the optimum performance of the valve is maintained. With reference to the exploded diagram: 1) On the Caleffi 5213 series valves, the inlet strainers (8) on both hot and cold water inlets can be removed for cleaning by unscrewing the inlet union nuts and carefully pulling apart the connecting pipework. 2) The built-in check valves (7) on the Caleffi 5213 series valves can be accessed in a similar way to 1) to ensure freedom of operation and correct seating. 3) Limescale can be removed by immersion in a suitable de-scaling fluid. 4) The valve body must not be disassembled. When this maintenance is complete, we recommend that the commissioning process is repeated. Should the valve still not function correctly, it may be necessary to replace it. We recommend that, as a safety measure, the Caleffi 5213 series is replaced after 5 years service. Contact Agent Service Department for details and advice. Spare parts The following spare parts for the Caleffi 5213 series are available upon request. Kit A - Service kit for the inlet sub-assembly. Refer to the exploded diagram. 10

Fault finding Under normal operating conditions the Caleffi 5213 series tempering valve will provide a very high level of performance. However, in some circumstances, where our maintenance plan is not followed, the following problems may arise. Symptom Hot water at the cold taps - cross connection Fluctuating mixed water temperature Erratic flow of water from the valve No flow of water from the valve Valve does not shutoff when tested Cause a) Operation of the insert check valve is hindered; check valve is not sealing correctly. b) Check valves not fitted. a) Erratic supply temperatures at the inlets of the valve. b)starvation of the water supplies at the inlets of the valve. c) Incorrect commissioning of the valve. a) Insufficient water supplies. b)fluctuations in supply pressures/temperatures. c) Adverse effect created by other draw off points on the system. a) In-line filters blocked. b)insufficient supply pressures. c) Debris obstructing valve operation. a) Installation not in accordance with our recommendations. b)the minimum temperature differential not achieved. c) Internal mechanism hindered by debris. Corrective action Replace faulty check valves Install the tail pieces with check valves at the cold and hot inlets Restore inlet conditions within the limits of the valve. Stabilise inlet supply conditions. Clean filters. Restore inlet supplies. Clean debris or scale from valve. Install as oulined in the instructions. Raise hot water temperature. Clean debris or scale from valve. 11

Safety Tempering valves must only be installed by a licensed plumber. A minimum temperature differential of 10 C is required between the hot water inlet and the mixed water outlet to ensure correct operation of the thermal shutoff feature. Water temperatures higher than 50 C can endanger people. The Caleffi 5213 series valve is not to be used in conjunction with instantaneous hot water boilers and systems. Their inclusion may compromise the correct operation of the instantaneous boiler unit. Ensure that the valve is supported and that the connecting pipework is not overstressed as breakages can cause harm to people and/or water damage to property. In the case of highly aggressive water, in accordance with the current legislation, treat the water before it enters the tempering valve. This will avoid damage to the valve. If the tempering valve is not installed, commissioned and maintained properly, according to the instructions contained in this manual, it may not operate correctly and may endanger the user. Leave this manual for the user AUSTRALIAN AGENT All Valve Industries Unit 2, 18-28 Sir Joseph Banks Drive Kurnell NSW 2231 Ph: (02) 8543 9811 Fax: (02) 8543 9822 Email: info@allvalve.com.au CALEFFI S.R. 229, n. 25 28010 Fontaneto d Agogna (NO) Italy Tel. Int. +39 322 8491 R.A. Fax +39 322 863723 Http://www.caleffi.com E-mail:info@caleffi.com