Actuator HON 670 / 671

Similar documents
safety shut-off Valve HON 703 / HON 704

Safety Relief Valve HON 832

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Gas Pressure Regulator HON 200

Pilot HON 630a, HON 640

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 300

Safety Shut-Off Valve HON 720

Gas Pressure Regulator HON 505

safety Shut-Off Valve HON 721

Safety Relief Valve HON 835

HON 219 Pressure Reducer (D119a)

Safety Shut-Off Valve RMG 711

SSV-Actuator HON 673 (K 1a, K 2a)

Safety Cut-Off Valve HON 305

Safety Shut-off Valve SSV

Gas Pressure Regulator RMG 201

RB 4700 Commercial & Industrial Regulator

Gas Pressure Regulator RMG 505

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Safety Relief Valve RMG 835

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Water Safety Shut-off Valve HON 790

Norval Pressure regulator

Gas Pressure Regulator HON 300

CASH VALVE TYPE KP BACK PRESSURE VALVES

RR 16 Commercial & Industrial Regulator

RMG 790 water Safety Shut-Off Valve

Pressure Regulator 133 / 233

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255

MODEL 240 GAS PRESSURE REGULATOR

Slam Shut Valves SCN

MODEL 274 GAS PRESSURE REGULATOR

MODEL 273PL GAS PRESSURE REGULATOR

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Safety shut-off valve Control Control Lock-up Over pressure set point Under pressure set point pressure range accuracy class

OPERATING INSTRUCTIONS

HON C210 Series Control Valves. High Pressure Control valves

VALVES HIDROMATIC VALVE.

RTG 25. Introduction

RR 16 Commercial & Industrial Regulator

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Safety shut-off valve S 100. Product information

Slam Shut Valves SBC 782

Safety shut-off valve S 50. Product information

627 Series Pressure Reducing Regulators

64 Series Pressure Reducing Regulators

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Type EZH Relief or Backpressure Regulator

PRESSURE REDUCING VALVE RP45 (EN)

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Valves. Diaphragm shut-off valves, kidney-type

Gas Pressure Regulator HON 280H - 309

Gas Pressure Regulator HON 270 MK2

RB 4700 Commercial & Industrial Regulator

Rate of Flow Valve Series 120

General Catalogue MEDENUS 2018/2019

Gas pressure regulator RS 254 / RS 255

PRESSURE REGULATORS. Type A/140. Process Management TM

Double gas valves for biogases and recycling gases

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

PRO-50 Instrument Supply Regulator

299H Series Pressure Reducing Regulators

Instruction Manual Contact Pressure Vacuum Gauge

1805 Series Relief Valves

Norval Pressure Regulators

Pressure Equalising Valves Model , for Differential Pressure Gauges

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Tightness controls TC 1 3 and TC 4

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Aperval Pressure Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

PC 50. Pneumatic Control Unit for safety valve control with piston and lifting device. Engineering GREAT Solutions

Gas Pressure Regulator R 51

HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution. Proven Technology. Superior Performance.

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Pressure Regulators for special applications

RB 4000 Commercial & Industrial Regulator

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Pressure ranges and accuracy classes for outlet pressure and safety devices

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

North American 7339 High Pressure Gas Regulators

Overflow Regulator TYPe 92-99

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

S300 Series. Valve Link. Features. Fisher Controls

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Pressure reduction controller (PN 16, 25, 40)

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

I Connected Industrial. HON 5020 Gas Pressure. Enabling Dependable Gas Operations

General Catalogue MEDENUS

Pressure reducing valves Index

Transcription:

Actuator HON 670 / 67 Product information serving the gas industry worldwide

Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger safety devices. They have the following tasks: 2 For the safety shut-off valve (SSV), e. g. the HON 7, HON 72 or HON 73, the task of automatically closing the actuator and thus shutting off the flow into the gas pressure regulating station, as soon as the pressure in the system to be safeguarded reaches an upper or lower response pressure; For the safety relief valve (SRV), e. g. the HON 80, the task of automatically opening the actuator as soon as the pressure in the system to be safeguarded reaches an upper response pressure. Characteristics High actuating accuracy Minimal difference between set pressure and pressure to be monitored Easy operation and maintenance Can be used for natural gas and all non-aggressive gases Technical data Permissible pressure load p emax 00 bar Version K6 / K7 for response pressures from 0.8 to 40 bar with diaphragm measuring unit K8 / K9 for response pressures 20 to 90 bar with metal bellows measuring unit for SSV release HON 670 / K6, K8 upper adjustment range W ho = 0.8 bar to 90 bar HON 67 / K7, lower adjustment range W hu = 2 bar to 40 bar for SRV release HON 670 / K6 / K8 adjustment range W h 0.8 bar to 90 bar Screwed pipe connection without brazing according to DIN 233 for pipe diameters Line connection Measuring line Vent line Discharge line Switching pressure line 2 mm 2 mm 2 mm 0 mm Operating temperature class 2 20 C to +70 C Materials Weight Body parts Internal parts O-rings Diaphragms Approx.. kg Aluminium alloy Al allow, stainless steel Rubber-like plastic Rubber-like plastic Function and strength According to EN 4382

Structure and mode of operation The actuator consists of a measuring diaphragm stage with double diaphragm system, amplifier valve and setpoint spring and of a base plate that contains the function lines within the actuator. The sensitive diaphragm system used in the actuators offers the advantage of a high actuating accuracy; in addition, the response pressure can brought very close to the pressure to be monitored. for SSV triggering: The pressure of the system to be safeguarded is routed to the top side of the sensitive double diaphragm system via a measuring line, and compared with the setpoint value specified through the setpoint adjustment screw (force of the setpoint spring). In normal operating status the amplifier valve is closed. The downstream system, including the actuator of the SSV is depressurised. If with the HON 670, the upper response pressure is reached, or if with the HON 67 the lower response pressure is reached, the amplifier valve opens. Gas flows out of the system to be monitored to the actuator of the safety shut-off valve. The piston in the pressure / force converter is moved and triggers the switch device of the SSV via the piston rod; the safety shut-off valve closes. 3 If the cause for the triggering of the SSV is eliminated and if the pressure to be monitored has been underranged (for upper triggering, HON 670) or exceeded (for lower triggering, HON 67), the specified set point, the amplifier valve closes. The pressure upstream of the piston of the actuator dissipates via the restrictor integrated in the actuator, and the safety shut-off valve can be reopened. The HON 670 actuator also satisfies the requirement that the safety shut-off valve should trigger if the measuring diaphragm breaks: The outlet pressure to be monitored is applied on the top side of the double membrane system. A defect of the double membrane system in this upper diaphragm causes the outlet pressure to be further routed directly to the pressure / force converter and thus cause the triggering of the SSV.

Structure and mode of operation Actuator HON 670 K6 (for upper setting range) Restrictor Vent / bleed line Amplifying valve Setpoint adjuster Setpoint spring Pressure transformer 4 Inlet (Measuring line) Double diaphragm system Actuator HON 670 K7 (for lower setting range) Restrictor Vent / bleed line Amplifying valve Setpoint adjuster Setpoint spring Pressure transformer Inlet (Measuring line) Double diaphragm system Actuator HON 670 K8 (for upper setting range) with metal-bellows measuring unit Setpoint adjuster Setpoint spring Restrictor Vent / bleed line Amplifying valve Pressure transformer Inlet (Measuring line) Metal-bellows measuring unit

Structure and mode of operation Mode of operation with SSV triggering: The safety relief valve (e. g. the HON 80), has the task of automatically opening as soon as the pressure in the system to be safeguarded reaches the set response pressure. The safety relief valve consists of the main valve and the HON 670 actuator. To protect the actuator against fouling a fine mesh filter is installed upstream. For the safety relief valve HON 80 the main valve is formed by a movable sleeve and the valve cone that is arranged stationary in the body. The actuator is permanently connected to the valve sleeve of the main valve. The upper and lower actuator chamber are connected to the stationary restrictor integrated in the base plate of the HON 670 actuator, so that in these chambers normally the same pressure predominates and the main valve is held in closed position via the closing spring. The pressure in the system to be safeguarded is routed into the actuator to the top side of the double diaphragm system via a measuring line, and compared with the setpoint value specified through the setpoint adjustment screw (force of the setpoint spring). In normal operating status the amplifier valve is closed; the pressures in the upper and in the lower actuator chamber of the HON 80 actuator are the same. If the pressure to be monitored reaches the response value set on the HON 670 actuator, the valve in the double diaphragm system opens. This dissipates the pressure in the actuator chamber below the driving piston. The system pressure on the top side of the actuator moves the sleeve against the closing spring in the opening direction, and the blow-off procedure of the safety relief valve is enabled. Then if the pressure to be monitored again underranges the specified setpoint, the amplifier valve closes and thus the pressure in the lower actuator chamber increases. For pressure compensation between the lower and the upper actuator chamber the safety shut-off valve again seals tight automatically. SRV HON 80 with actuator HON 670 / K6 Manual release button Discharge line Main valve Main valve Actuator device HON 670 / K6 Valve cone Vent line Valve sleeve Start-up valve Closing spring Filter Measuring line

Dimensions and setting ranges Actuator K6 / K7 Actuator K8 Measurement connection only for SRV solution Measuring impulse connection only for SRV solution H 6 D D only for SRV triggering Stage with ball-guide sleeve G Dimensions in mm Version A B C D(max) E F G H J K6 / K 7 26 00 9 7 0 20 SSV version K6KF / K 7KF* 26 00 2 7 0 20 K8 3 340 8 8 SRV version K 6 K 8 26 00 3 40 37 9 340 7 8 0 38 38 * Stage with ball-guide sleeve Setting ranges of the ACTUATORs Setpoint spring SSV overpressure SSV underpressure for SSV Actuator Wire ø in Setting range Least difference between response pressure and normal operating pressure Setting range Least difference between response pressure and normal operating pressure Overpressure least difference between response pressure & normal operating pressure Accuracy group** No. 0 Colour blue mm 3.2 W ao (bar) 0.800....00 p (bar) 0.00 W au (bar) p (bar) Δp (bar) AG 2. black 4..000....000 0.200 0. 2./ K6 2 grey.0 2.000... 0.00 0.400 0.6 3 brown 6.3.000... 20.00 0.800.0 4 red 7.0 0.00... 40.00.200. 2 grey.0 2.000... 0.00 0.400 K7 3 brown 6.3.000... 20.00 0.800 4 red 7.0 0.00... 40.00,200 K8 9.0 20.00... 90.00,00 2,0 **) The higher accuracy group (AG) applies for the first half, the lower accuracy group applies for the second half of the setting range.

Device designation Example: HON 670 - A - 3 - So TYPE OF PILOT 7 Type of pilot HON 670 HON 67 version SSV SRV A B Setting ranges Actuator W ho Setting range in bar W hu K6 K6 K6 / K7 K6 / K7 K6 / K7 K8* 0.8.....0....0 2.0... 0.0.0... 20.0 0.0... 40.0 20.0... 90.0 2.0... 0.0.0... 20.0 0.0... 40.0 0 2 3 4 Special version Special design (must be explained in more detail) So *) With metal-bellows measuring unit

For More Information To learn more about Honeywell s Advanced Gas Solutions, visit www.honeywellprocess.com or contact your Honeywell account manager GERMANY Honeywell Process Solutions Honeywell Gas Technologies GmbH Osterholzstrasse 4 3423 Kassel, Deutschland Tel: +49 (0)6 007-0 Fax: +49 (0)6 007-07 HON 670.00 / 67.00 207-0 207 Honeywell International Inc.