VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Similar documents
VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

Double valves for biogases and recycling gases

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Valves for Biogases and Recycling Gases

VGD40.../VGD41... Double gas valves. Building Technologies Division

Double gas valves for biogases and recycling gases

Double gas valves. The VGDs are primarily suitable - On gas-fired combustion plant - In gas trains in connection with forced draft gas burners

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

Actuators for gas valves

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

2-Port Seat Valves with Flange, PN 16

2-port and 3-port valves PN 16

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

2-Port Seat Valves with Flange, PN 16

Actuators for gas valves

2-port seat valves PN25 with externally threaded connections

3-port seat valves with externally threaded connection, PN 16

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Two-port seat valves

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

2-port and 3-port seat valves, PN16

GM-7000 Series CE Approved Gas Control Valve

Dual Solenoid Gas Valve Installation

GM Series Dual-Block Multi-Function Gas Control Valves

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

2-Port and 3-Port Seat Valves with Female Thread, PN16

Two-port valves, male threaded, PN25

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Pressure and Flow Control Valves DBGM, German and European Patents

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

GM-7000 Series CE Approved Gas Control Valve

Pressure Independent Control Series

Radiator valves VDN1.. VEN1..

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

PRESSURE REDUCING VALVE RP45 (EN)

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

GAS PRESSURE REGULATORS AND FILTERS.

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Safety shut-off valve S 50. Product information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Gas Pressure Regulator HON 200

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Old documentation - Only for your information! Product is not available anymore!

Tightness control TC. Product brochure GB 3 Edition AGA

Pressure reducing valves Index

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Pressure Reducing Valve DMV 750 set range: bar

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Radiator valves VDN2.. VEN2.. VUN2..

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Gas Pressure Regulator HON 300

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

V43 Pressure Actuated Water Regulating Valve

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Tightness controls TC 1 3 and TC 4

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Seated valves VRB 3, VRG 3

V311. Venta. Three-way Plug Valve, Flanged PN 16

Safety Shut-off Valve SSV

Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

BGA158 Series CE Approved Class B Shutoff Gas Valve

2/2-Way Solenoid Control Valve

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Gas Pressure Regulator HON 505

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Gas Pressure Regulator R 51

Transcription:

7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN161 in connection with actuators Suitable for use with gases of gas families I...III Gas valves in connection with actuators open slowly and close rapidly 2-port valves of the normally closed type ½... DN125 The gas valves are used in combination with the SKP / SKL actuators As a control valve in connection with SQX... actuators and AGA60 adapter (not as a safety shutoff valve) Supplementary Data Sheets on actuators (refer to «Mechanical design») The VG... and this Data Sheet are intended for use by OEMs which integrate the gas valves in their products! 11.06.2008 HVAC Products

Use The gas valves are used primarily - for application at gas-fired combustion plant - for gas trains at forced draft burners The gas valve is used as: - Shutoff valve (in combination with SKP1...) - Control valve with shutoff feature (in combination with SKP2..., SKP5 or SKP7 ) - As shutoff or control valves in the supply air line of industrial combustion plant with or without heat recovery system If the gas valves are used with gases other than those of gas families I...III, Siemens assumes no responsibility for the valve s durability and life expectancy. All types of gas valves can be combined with any of these actuators. Warning notes To avoid inquiry to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the gas valves except when installing the service replacement kit Any opening of the gas valve, replacement of parts or modifications to the original product is the user s responsibility and carried out at his own risk All activities (mounting, installation and service work, etc.) must be performed by qualified staff When used in connection with gas, the gas valves constitute part of the safety equipment In combination with SQX... or SKL... actuators, the gas valves must not be used as safety devices Fall or shock can adversely affect the safety functions. Such gas valves must not be put into operation, even if they do not exhibit any damage Not suitable gases or gas components causes loss of the safety shutoff function It may not join contaminant / particles in the valve, because that could adversely affect the safety shutoff function Engineering notes Profile (only for VGG... / VGF...) Owing to the profile of valve disc, the gas valves are especially suited for control functions. Benefit: Good control performance and hardly prone to hunting in low-fire operation. 1 2 766z10/0502 Legend 1 Stem 2 Profile Valve disc 2/18

Mounting notes Ensure that the relevant national safety regulations are complied with The actuator can be mounted or replaced while the gas valve is under pressure Refer also to the following Mounting Instructions AGA66 M764.2 74 19 0421 0 VGF M766 / M761 41920720 VGFDN40...80 M766.1/M76 41920500 VGG M766 / M761 41920720 VGG1/2"..." M766.1/M76 41920500 VGH M766 / M761 41920720 VGx10.654 M766.2 4192450 VGx10.804 M766.2 4192450 Sealing / tightness Mounting position Direction of flow Function Only VGG...: Only VGD20 Only VGF.../VGH... Check to ensure that the gas valve is tight when all components are connected Check to ensure that the gaskets between the flanges and the gas valve must be fitted The permissible mounting positions of the actuator must be observed, however (refer to the relevant Data Sheet). The direction of gas flow must be in accordance with the direction of the arrow on the valve body. The inactive gas valve is closed and opens when the actuator opens. Check to ensure that cuttings not falling into the gas valve when mounting the connecting pipes. As the case arises, the gas valve can be opened and cleaned from below (spring dome) To prevent cuttings from falling into the gas valve, first mount the flanges on the pipes and then clean the parts Check to make certain that the bolts of the flanges are properly tightened and afterwards check to ensure that the gas valve is tight when all components are connected /18

Standards and certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Directive for gas appliances - Directive for pressure devices 2004/108/EC 90/96/EEC 97/2/EC ISO 9001: 2000 Cert. 0079 ISO 14001: 2004 Cert. 82 For use in the U.S. / Canada, the gas valves carry type suffix «U» (see example) and, and listed. Example: VGG10.204U Approvals in combination with actuator Type reference VGG10.154P x x VGG10.204P x x x VGG10.254P x x x VGG10.404P x x x VGG10.504P x x x VGG10.804P x x x VGG10.1541P x x VGG10.2041P x x VGG10.2541P x x VGG10.4041P x x VGG10.5041P x x VGG10.204 x x VGG10.254 x x VGG10.404 x x VGG10.504 x x VGF10.404P x x VGF10.504P x x VGF10.654P x x x VGF10.804P x x x VGF10.5041P x x VGF10.6541P x x VGF10.8041P x x VGF10.404 x x VGF10.504 x x VGF10.654 x x VGF10.804 x x VGH10.18050 x x x VGH10.19050 x x x VGH10.19150 x x x 4/18

Service notes Each time a gas valve has been replaced, check to ensure that the gas valve operates correctly and that it is tight both internally and externally Siemens gas valves may only be repaired by Siemens HVAC Repair Centers VGH... gas valves are supplied without strainer. Fit a gas filter upstream of the gas valve or an AGA... strainer (refer to «Accessories») by the gas inlet Life cycle The combination gas valve VG... and actuator have a designed lifetime* of 100,000 burner startup cycles which, under use of gases to EN47 (or DVGW specification G260). This lifetime is based on the endurance tests specified in standard EN161 and the table containing the relevant test documentation as published by the European Association of Component Manufacturers (Afecor) (www.afecor.org). The designed lifetime is based on use of the gas valve VG... and actuator according to the manufacturer s Data Sheet. After reaching the designed lifetime in terms of the number of burner startup cycles, or the respective time of usage, the gas valve VG... and actuator are to be replaced by authorized personnel. * The designed lifetime is not the warranty time specified in the Terms of Delivery Disposal notes Local and currently valid legislation must be observed. 5/18

Mechanical design VGG... / VGF... Stem Strainer Valve seat The gas valves are dead closed in combination with actuator. The stem is guided on both sides of the valve disc, ensuring precise axial stroke and tight shutoff. A strainer made of stainless steel is fitted in the gas valve s inlet and protects the gas valve, the seat and disc as well as downstream devices against dirt. For use with profile, the gas valves carry type suffix «P» (see example) Example: VGG10.154P VGH... Strainer Valve seat Actuators A strainer type AGA... is available as an accessory item (refer to «Accessories»). The gas valves are supplied without strainer (refer to «Engineering notes»). They are of the normally closed one-way high-flow type. The swiveling disc of gas valve has no profile. The gas valves can be combined with the following types of actuators: Type reference Data Sheet Function SKP15... N764 ON / OFF SKP25... N764 ON / OFF with constant pressure control SKP25.7... with SQS7... N764 ON / OFF with pressure control and via electric signal alterable setpoint setting SKP55... N764 ON / OFF with differential pressure control, signal input differential pressure SKP75... N764 ON / OFF with ratio control, signal input static pressure SKL25... (only for air) N764 ON / OFF with constant pressure control, slow closing 4...6 s, no function of safety shutoff SQX... with AGA60 N4554 Steady position control, no function of safety shutoff 6/18

Type summary (other types of gas valves on request) Perm. operating pressure in Number of connections Type reference mbar Air flow rate at With profile Without profile Europe Other Δp = 1 mbar Test point Pilot gas Without stroke With stroke Without stroke With stroke Nominal size Material (to EN) countries / m³ / h RP ¼ ) G ¾ 4) limitation limitation 1) limitation limitation 1) Internally threaded to ISO 7/1 ½ Die-cast al. 1200 1200 4.8 4 VGG10.154P VGG10.1541P ¾ Die-cast al. 1200 1200 (1400)* 8.9 4 VGG10.204P VGG10.2041P VGG10.204 1 Die-cast al. 1200 1200 (1400)* 1. 4 VGG10.254P VGG10.2541P VGG10.254 1 ½ Die-cast al. 600 600 (1400)* 2. 4 VGG10.404P VGG10.4041P VGG10.404 2 Die-cast al. 600 600 (1400)* 47.4 4 VGG10.504P VGG10.5041P VGG10.504 Cast iron 600 600 (700)* 85.4 2 2 VGG10.804P * Only for use in Australia With flange, PN16, to ISO 7005 DN40 Cast iron 600 600 2. 4 VGF10.404P VGF10.404 DN50 Cast iron 600 600 47.4 4 VGF10.504P VGF10.5041P VGF10.504 DN65 Cast iron 600 600 (700)* 74 2 2 VGF10.654P VGF10.6541P VGF10.654 DN80 Cast iron 600 600 (700)* 85.4 2 2 VGF10.804P VGF10.8041P VGF10.804 * Only for use in Australia Flap type gas valves: High-flow with swing type disc. Great closing force. Version without strainer, to DIN, only for use on plant with gas strainer. We recommend to install a strainer (refer to «Accessories» AGA80, AGA90 or AGA91! These gas valves may only be revised by Siemens Repair Centers DN80 Cast iron 00 600 (700)* 128.4 4 1 VGH10.18050 DN100 Cast iron 00 400 (700)* 199.5 4 1 VGH10.19050 DN125 5) Cast iron 250 250 (500)* 277.6 4 1 VGH10.19150 * Only for use in Australia with SKPxx.xxxFxx (must be checked by application side) Legend (also refer to «Dimensions») 1) Cannot be used with attached pressure governor 4) Inlet side, VGF... with one connection on each side 2) Flow rate reduced by 20 % 5) Only for SKPx5.xxxFxx ) On inlet and outlet side Ordering When ordering, please give the complete gas valve type reference. Actuator and gas valve are supplied as single packs. Example: 1 piece VGF10.654P flanged valve DN65 1 piece actuator 7/18

Accessories Manual adjuster AGA61 Adapter for SQX... actuators Consisting of 2 stem parts and a connecting flange AGA60 Gasket kit to SKP... / SKL25... - Between actuator SKP / SKL25 and gas valve VG - For increasing of degree of protection from IP54 up to IP65 - Refer to Mounting Instruction M764.2 (74 19 0421 0) AGA66 Only VGG10.154, VGG10.204, VGG10.254, VGG10.404 : When used in connection with AGA66, the maximum flow rates are reduced by about 25 %. VGH... Strainer With circlip and 1 mm mesh size. Type reference of gas valve VGH10.18050 / DN80 VGH10.19050 / DN100 VGH10.19150 / DN125 Type reference of strainer AGA80 AGA90 AGA91 The strainers can be fitted in the flange sections of the gas valves, either on the gas inlet or gas outlet side. 8/18

Technical data General unit data Valve class in connection with actuator A conforming to EN161 (except with SQX... / SKL...) Group 2 (EN161) Perm. medium temperature 0...60 C Weight Refer to «Dimensions» Connecting flanges (VGF..., VGH...) PN16 to ISO 7005-2 Required flow rate Refer to «Flow chart» Perm. mounting position 7648z09/060 Operating pressure Types of gases Strainer (only for VGG... / VGF...) (refer to «Mounting notes») Refer to «Type summary» Refer to «Use» Built-in, mesh size 0.9 mm Environmental conditions Storage DIN EN 60721--1 Climatic conditions Class 1K Mechanical conditions Class 1M2 Temperature range -20...+60 C Humidity <95 % r.h. Transport DIN EN 60721--2 Climatic conditions Class 2K Mechanical conditions Class 2M2 Temperature range -20...+60 C Humidity <95 % r.h. Operation DIN EN 60721-- Climatic conditions Class K Mechanical conditions Class M Temperature range -10...+60 C Humidity <95 % r.h. 9/18

Function Sectional view of VGG... pe 766z19/0805 Application example VGG... complete with SKP25... Sectional view VGG... complete with SKP25... 766z20/0805 pe 10/18

Function (cont d) Sectional view of VGF... 766z2/0408 pe Application example VGF... complete with SKP25... Sectional view VGF... complete with SKP25... 766z22/0408 pe 11/18

Function (cont d) Sectional view of VGH... Strainer Fully closed 766z06e/0100 Strainer Fully open Application example VGH... complete with SKP25... Sectional view VGH... complete with SKP25... pe 766z21/0805 12/18

Flow chart for VG... (For fully open gas valves only) 2 4 5 7 10 2 4 5 7 100 2 4 5 7 1000 2 4 5 7 2 4 5 7 10 2 4 5 7 100 2 4 5 7 1000 2 4 4 5 7 10 4 5 7 100 2 4 5 7 1000 2 4 5 7 2 4 5 7 10 2 4 5 7 100 2 4 5 7 1000 2 4 5 1000 700 500 400 00 200 100 70 50 40 0 20 p mbar 766d01e/0608 VGG VGF 10 7 5 4 2 1 0.7 0.5 0.4 0. 0.2 m / h 1 Natural gas m / h 2 Propane m / h Town gas m / h 4 Air 1/2" ) /4" ) 1" ) VGH 1) DN40; 1 1/2" Flow chart DN50; 2" DN65 DN80; " DN80 1) Corresponding to fully open valve or governor 2) Without strainers ) Flow rate of valves with throttle 20 % lower DN100 DN125 For control performance reasons, when using the SKP2... actuators with integrated governor, the nominal valve size should not be too large. This applies in paricular to burners burning small amounts of gas in the low-fire position and to burners changing from high-fire to low-fire in less than 5 s. Conversion factors 1 Natural gas 1.24 2 Liquefied petroleum gas 0.77 Town gas 1 1.46 4 Air f = 1 Calculation fo factor "f" For other types of gases 1 f = dv (gas) dv = density ratio to air Iff possible select flow rate within bold lines! Flow rate m / air x Wobbe number (MJ/m ) = burner output (MJ/h) Calculation example Available pressure drop across the valve 2 mbar Required flow rate 60 m /h natural gas Selection according to chart DN1 1/2" (point of intersection of 2 mbar and 60 m /h natural gas) Legend Maximum flow rate (gas valve fully open) 1) The valve curves shown represent gas valves with no strainer. Each strainer reduces the flow rate by about 8 % The bold curves represent the recommended pressure drop ranges. Gas valves with higher pressure drops can cause excessive flow noise. Practical experience shows that applications outside the range confined by the bold characteristics could produce significant noise 1/18

Flow chart (cont d) Note: In the case of burners with low-fire flow rates, select a tightly sized gas valve (refer to the Data Sheet of the relevant actuator) If the available gas pressure exceeds the maximum permissible operating pressure, use an upstream pressure controller to lower it The pressure drop (curves of maximum flow) is based on a fully open gas valve Conversion of air flow rate to a corresponding gas flow rate (natural gas): Basis for scale Abscissa Volumetric flow «QG» in m³/h Density ratio «dv» to air Conversion factor 1 f = dv 1 Air 1 1 2 Natural gas 0.61 1.28 Propane 1.562 0.8 4 Town gas 0.46 1.47 Conversion to air (m³ / h) from other types of gases: QL= QG f QL = air volume in m³ / h that produces the same pressure drop as «QG» When used in connection with actuators having an integrated governor, the nominal valve size should not be selected too large to ensure good control performance. 14/18

Dimensions Dimensions in mm VGH... / DN80...125 E G /4 P N M L Q J H R 4 x Rp 1/4 S T A B K 766m05/0502 F VGF... / DN 40...50 4 x Rp 1/4 P 86 S T C D Q N M L J R A B K 60 80 E F 766m04/0502 15/18

Dimensions (cont d) Dimensions in mm VGF... / DN 65...80 G G Rp 1/4 86 Rp 1/4 P Q N M L R 80 C D J H 2 x G /4 S E F A B K 766m07/0502 VGG / G 86 G Rp 1/4 Rp 1/4 J H DN SW 2 x G /4 T DN C D E 80 F 766m08/0502 16/18

Dimensions (cont d) Dimensions in mm VGG ½...2 86 JDN DN SW 4 x Rp 1/4 S T 80 C D E F 766m01/0502 Mounting surface for actuator or AGA60 adapter flange for SQX... actuator 17/18

Dimensions (cont d) Table of dimensions Typ VGG10.15... VGG10.20... VGG10.25... VGG10.40... VGG10.50... VGG10.80... DN 1) 1/2" /4" 1" 1 1/2" 2" " A B C 96 96 96 126 10 191 2) ) D 79 79 79 107 16 E 80 80 80 126 126 185 F 109 109 109 150 170 10 G 110 G 110 H 68 J 2 2 2 41 50 100 K L M N VGF10.40... VGF10.50... VGF10.65... VGF10.80... DN40 DN50 DN65 DN80 1 1 16,5 19 126 10 191 191 107 16 16 126 126 185 185 200 20 290 10 108 118 108 118 95 41 50 92 100 19 19 19 19 150 165 185 200 110 125 145 160 88 120 11 VGH10.180... VGH10.190... VGH10.191... DN80 DN100 DN125 15 16 160 160 160 10 50 400 105 105 121 159 166 174 19 19 19 200 220 250 160 180 210 11 157 187 DN Nominal size, dimension for connection of medium 1) Flange conforming to ISO 7005-2 2) With stroke limitation ) Without stroke limitation R Number of boreholes; for standards for flanges and threads, refer to «Type summary gas valves» * Width across flats P 45 45 45 22,5 22,5 22,5 22,5 Q 90 90 90 45 45 45 45 R 4 4 4 8 8 8 8 S 28 28 28 4 4 6 42 95 95 95 T 1 1 1 4 4 62 6 42 95 95 95 SW* 46 46 46 60 75 120 kg 0,8 0,8 0,75 1,4 1,95 1,4 6 7,5 15, 17,9 16, 18,6 2,4 18/18 2008 Siemens HVAC Products GmbH Subject to change!