protecting your workers from the hazards of arc flash

Similar documents
Solutions SOLUTIONS GUIDE SOLUTIONS GUIDE. It s your responsibility to protect your workers from arc flash hazards

Progressive Safety Services LLC - All Rights Reserved

Helping Employers. Protect Workers. from Arc Flash and other Electrical Hazards

PURE H2O FORUM. Safeguarding Operations Personnel Understanding Arc Flash & Developing an Electrical Safety Program

arc flash hazard analysis

Why an Effective Safety Program is Essential

Electrical Safety Guide

ARC FLASH HAZARD ANALYSIS

Electrical Safety Guide

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

Electrical Hazard Assessments: OSHA & The NFPA 70E?

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer

Why do I need to do an Arc-Flash Analysis?

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

Electrical Safety Work Practices

Arc Flash. Safety 21

SAFE-WORK PRACTICES Working On Or Near Energized Electrical Equipment CAT A-1 SOP #4

Definitions found in several locations:

Electrical Safety Program

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program.

NECA Personal Protective Equipment (PPE) Selector

2012 NFPA 70E: Electrical Safety In The Workplace

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

2. What is the definition of an electrocution hazard? a. Electrocution results when a person is exposed to a lethal amount of electrical energy

70e Training - Electrical Safety in the Workplace

Making Safer Facilities

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

By: Bruce Bowman, P.E.

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

ANSWER SHEET NFPA 70E REVIEW 51. A B C D 76. A B C D 2. A B C D 77. A B C D 3. A B C D 52. A B C D 78. A B C D 4. A B C D 53.

Electrical Safety Program

WHAT IS THE N.F.P.A. 70E

Electrical Safety. Introduction

Leader s Guide ERI Safety Videos

This presentation provides an overview of modern methods for minimizing the arc-flash hazard.

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

Original Date of Issue: 04/09

100 Questions on Electrical Safety Study Guide

Leader s Guide ERI Safety Videos

Dealing with Electrical Hazards in the Workplace

Arc Flash 101. presented by Arc Flash Blaster LLC

UNDERSTANDING ARC FLASH REQUIREMENTS

Electrical Safety Program

NFPA 70E Policies and Best Practices

JOB HAZARD CHECKLIST

2. The purpose of this program is to achieve the following objectives:

POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH

Written Programs Listing

THE OSHA LOCK-OUT/TAG-OUT STANDARD

Electrical Safety. Toolbox Talk

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager

2018 NFPA 70E Electrical Safe work practices

Lockout / Tagout Safety Program

Electrical Safety Program

RiskTopics. Lockout/Tagout October 2017

This training session covers electrical safety for unqualified persons. Unqualified persons are machine operators, operators of powered industrial

SPECIALIZED ONLINE TRAINING COURSE LIST

NFPA 70E What Changed? Keeping People Safe from Electrical Hazards for over 50 Years

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

ELECTRICAL FLASHOVER HAZARDS AND SAFETY MEASURES REFERENCE TO DESIGN AND MAINTENANCE. Intrduction: B.MAHARANA, AGM(EM)/HOD NTPC,RAMAGUNDAM

The Electrical Safety Guide. An Educational Training Manual for Industry Professionals

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Elements of a Lockout/Tagout Program OSHA

Best Practice #207. Facility: Entire DOE Complex. Best Practice Title: Identification of Look-Alike Electrical Equipment

Pulp & Paper Electrical Safety

2523-LDG-E. Leader s Guide

D Square Construction LLC

1 Purpose. 2 Responsibilities. 3 Policy Content ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS. TITLE: CONFINED SPACE ENTRY Document Number: *

Electrical Safety Program

Lockout/Tagout Program

PALM BEACH STATE COLLEGE PERSONAL PROTECTIVE EQUIPMENT (PPE) JOB HAZARD ASSESSMENT

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com

2018 NFPA 70E Significant Changes 7/27/2017. EFCOG Electrical Safety Task Group Workshop, July 2017

Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING. Presented By Rick Edel

11/2/2017. Course Objectives. Overview

NPGA White Paper. OSHA Hazard Communication Standard

LO/TO LOCKOUT/TAGOUT PROGRAM

Electrical Safety. Unqualified Worker

IWU PHYSICAL PLANT SAFETY PROGRAM. Revision: 1 ELECTRICAL SAFETY Section: 4

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING. Leader s Guide. ERI Safety Videos

PERSONAL PROTECTIVE EQUIPMENT

Personal Protective Equipment Program

Appendix A: Energized Work Permit

ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

Health and Fire Safety Review 2/15

Lockout/Tagout Safety Policy

LOCKOUT/TAGOUT PROGRAM

DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM

Appendix B Personal Protective Equipment (PPE) Hazard Assessment Instructions

MANAGING ARC FLASH: A Risk Management Approach. Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane

Lockout/Tagout - Control of Hazardous Energy Program

Safety Meeting Topic #6 Working Around /On Energized Equipment

Ground Fault Circuit Interrupter(GFCI) Policy

Lockout Tagout Program

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard

State University of New York College at Oneonta

Transcription:

protecting your workers from the hazards of arc flash

Stay current on standards and regulations Being responsible for your workers safety means being up to date on the various regulatory and consensus standards applicable to arc flash hazards. The four major industry standards that have the most impact are OSHA regulations, NFPA 70E, IEEE Standard 1584, and NFPA 70, National Electrical Code. This image, taken from high-speed, specially filtered digital video shot during testing in Ferraz Shawmut s high-power lab, illustrates the type of blast that can occur. The explosive power of an arc flash The many intense hazards created by arcing faults in today s industrial power systems arise from two factors the tremendous amounts of power that can be delivered to such arcs and the workers close proximity to them. When an arcing fault is established, current passes through ionized air. Large volumes of ionized gases, along with molten metal from the vaporized conductors, are rapidly expelled. As the arc runs its course generally in less than 0.2 seconds electrical energy continues to be converted into extremely hazardous forms of energy, including: Intense heat capable of causing severe, often fatal, burns, even beyond typical working distances. A thermoacoustic shock wave that can result in ruptured eardrums, collapsed lungs or fatal injuries. Molten metal, at temperatures typically exceeding 1000 C, reaching distances of several feet. Shrapnel that can impact a nearby worker at high velocity, resulting in physical trauma. Blinding light, which can cause immediate vision damage and increase the potential for future deterioration. Toxic smoke, including combustion byproducts and copper oxides. Contact with energized components the explosive nature of an arc fault increases the possibility that an energized conductor or component will make contact with workers in the area. OSHA regulations OSHA regulations mandate that employers provide a safe workplace. Specifically, OSHA Standard 29 CFR Part 1910, Subpart S, addresses safety-related practices for electrical work. It makes clear that, with very few exceptions, equipment must be deenergized before work is performed, and lockout/tagout procedures must be followed. However, if equipment cannot be deenergized prior to work, the standard requires that: Employees are properly protected by personal protective equipment (PPE) appropriate for the work being performed. Employers perform an electrical hazard assessment to determine if hazards are present or likely to be present, select the necessary PPE, and communicate those selection decisions to each affected employee. See the box (far right) for specific text from Subpart S. In addition, OSHA 29 CFR Part 1910 contains many other sections that pertain to electrical safety and arc flash hazards. They address safety requirements, personal protective equipment, and general environmental controls, such as lockout/tagout. The NFPA 70E standard For details on how to conduct an electrical hazard assessment or how to select PPE, you must look to national consensus standards. NFPA 70E, Standard for Electrical Safety in the Workplace, is one of the foremost consensus standards for electrical safety. Developed by the National Fire Protection Association, it addresses employee protection from the electrical hazards of shock and arc flash. Referenced in OSHA 29CFR Part 1910, Subpart S, Appendix A, NFPA 70E is considered by OSHA to be the recognized industry practice for electrical safety. In its standard interpretation of the relevance of NFPA 70E, OSHA states: Industry consensus standards, such as NFPA 70E, can be used by employers as guides to making the assessments and equipment selections required by the standard. Similarly, in OSHA enforcement actions, they can be used as evidence of whether the employer acted reasonably.

Chapter 1 of NFPA 70E provides guidance on establishing electrically safe work conditions and developing such safetyrelated work practices as a safety program and worker training. And while it emphasizes that working on live parts is the last alternative work practice, NFPA 70E contains extensive requirements for working on or near electrical conductors or circuit parts that have not been put into an electrically safe condition. One of the requirements is electrical hazard analysis, which includes arc flash hazard analysis. IEEE Standard 1584 TM-2002 As implied by its title, Guide for Performing Arc Flash Hazard Calculations, IEEE Standard 1584 provides techniques for performing a comprehensive arc flash hazard analysis. Its systematic, nine-step approach enables designers and facility operators to determine the arc flash-protection boundary, defined as an approach limit at a distance from exposed live parts within which a person could receive a second-degree burn if an electrical arc flash were to occur. Of course, there are other benefits to performing an electrical hazard analysis. By providing an in-depth look at your plant s electrical system, it supplies data that can be used to improve overall system performance, reduce downtime and manage costs. NFPA 70, the National Electrical Code While the NEC has traditionally addressed installation techniques intended to prevent fire, electrocution and shock hazard, it now contains requirements related to arc flash hazards. Section 110-16, Flash Protection, requires that markings be placed on switchboards, panelboards, industrial control panels and motor control centers to warn qualified persons of potential arc flash hazards. We can help you mitigate arc flash hazards Personal protective equipment is a worker s last line of defense against arc flash hazards. In addition, here are ways to reduce the hazard level: Upgrade branch circuit fuses to Ferraz Shawmut s Amp-Trap 2000 current-limiting fuses. Extensive testing to IEEE 1584 test protocols has shown that these fuses our A6D Class RK1, A4BQ Class L, and AJT Class J limit arc flash incident energies to very low values for arc fault currents within their current-limiting range. Applied properly, they can reduce the category of PPE required to protect workers. Make sure you have the right fuses on hand. Obsolete and out-of-stock fuses increase the potential for dangerous misapplications. Ferraz Shawmut s inventory analysis and upgrade services help ensure that your inventory is complete and up to date. Provide safety training for your staff. In addition to in-depth seminars on arc flash hazards designed for engineers and safety managers, we provide circuit protection safety training for electrical workers, purchasing professionals and storeroom personnel. Use IP20-rated devices wherever possible. Ferraz Shawmut offers a complete line of finger-safe products, including Socomec disconnect switches, UltraSafe fuse holders, and our FSPDB, the industry s first finger-safe power distribution block. Ferraz Shawmut current-limiting fuses and finger-safe devices can help reduce the risk of arc flash. Visit ferrazshawmut.com/arcflash for the latest developments in arc flash safety and our online arc flash calculator.

Visit the Arc Flash Info Center Arc flash safety is an expansive topic and one that continues to evolve. Ferraz Shawmut s Arc Flash Info Center is a valuable, 24-hour source of current information. Visit ferrazshawmut.com/arcflash, and you ll find more about current limitation, other suggestions for reducing arc flash energies, and an online calculator you can use to determine incident energies and PPE categories for Ferraz Shawmut fuses. You can also register for our keep me informed alerts, and be the first to know about new arc flash solutions. Should you have specific questions about arc flash hazards, arc flash hazard mitigation, or circuit protection in general, contact your Ferraz Shawmut sales representative or field engineer, or call our Technical Services applications engineers at 978-465-4853. Protecting your workers from the hazards of arc flash is a big responsibility, but it doesn t have to be a difficult task. With our assistance, you ll see how Ferraz Shawmut products and services can help mitigate arc flash hazards. OSHA Standards OSHA outlines these employer responsibilities in Standard 29 CFR Part 1910, Subpart S: Equipment must be deenergized before work is performed In addressing work on electrical equipment, 1910.333(a)(1) states: Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Lockout/tagout procedures must be used In Note 2 of 1910.333(b)(2), it states: Lockout and tagging procedures that comply with paragraphs (c) through (f) of 1910.147 will also be deemed to comply with paragraph (b)(2) of this section, provided that: [1] The procedures address the electrical safety hazards covered by this Subpart; and [2] The procedures also incorporate the requirements of paragraphs (b)(2)(iii)(d) and (b)(2)(iv)(b) of this section If equipment cannot be deenergized prior to work: Employees must be properly protected When employees are required to work where there is a potential electrical hazard, 29 CFR Part 1910.335 mandates that employees: shall be provided with, and shall use electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. In addition, the appendix to Part 1910 Subpart S includes NFPA 70E as a reference that provides information which can be helpful in understanding and complying with the requirements contained in Subpart S. Employers are responsible for performing a hazard assessment 29 CFR Part 1910.132(d), hazard assessment and equipment selection, states: The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: 1910.132(d)(1)(i) Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; 1910.132(d)(1)(ii) Communicate selection decisions to each affected employee; and, 1910.132(d)(1)(iii) Select PPE that properly fits each affected employee. This is the section referenced in the OSHA standard interpretation that discusses the relevance of NFPA 70E. The remainder of 1910.132 outlines the requirements for the design, application, proper selection, training and documentation required for the use of personal protective equipment.

Why arc flash is a vital and timely topic If previous statistics hold true, the explosive energy released during arcing faults will send more than 2,000 workers to burn centers this year. This type of event an arc flash can occur in any type of plant, and can result from something as simple as a tool accidentally dropped on an energized part. The cost to human life can be incalculable. The cost to a business, in medical expenses, equipment replacement and downtime, can easily exceed $1 million. Today, that cost can also include significant fines. OSHA has become much more vigilant, and is using the requirements of NFPA 70E, Standard for Electrical Safety in the Workplace, to judge whether an employer acted reasonably in protecting its workers from arc flash hazards. As an employer, you have a moral responsibility to protect your employees from harm. And now, the financial and legal obligations inherent in electrical accidents are even greater.

North American Headquarters 374 Merrimac Street Newburyport, MA 01950-1998 Phone: 978-462-6662 Fax: 978-462-0181 Global Headquarters 1, rue Jean Novel F-69100 Villeurbanne, France Phone: +33 (0)4 72 22 66 11 Fax: +33 (0)4 72 22 67 13 Ferraz Shawmut Canada 88 Horner Avenue Toronto, Ontario, Canada M8Z 5Y3 Phone: 416-252-9371 Fax: 416-252-6572 ferrazshawmut.com/arcflash ferrazshawmut.com 2005 Ferraz Shawmut