Infrared Thermometer Instruction manual

Similar documents
Infrared Ear and Head Thermometer Instruction Manual

Digital Ear Thermometer

Ambient Weather WS-03 Thermo-Hygrometer

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

GentleTemp 510. Digital Ear Thermometer

Contents. Safety Notice. Wrist Type

WARNING: EXPLOSION HAZARD

Digital Blood Pressure Monitor. Model UA-787

testo Leakage detector for refrigerants Instruction manual

Fingertip Pulse Oximeter

Vet-Temp Ear Thermometer Frequently Asked Questions

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Operating Manual Body fat balance

EC214 EC215 - EC215R Bench Conductivity Meters

6 digital caliper with case

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Cadence Sensor W.I.N.D. User Manual

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

HawkEye Handheld Sonar System PX Instruction Manual

model 304 ShrinQ PEDOMETER

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Blood Pressure Monitor Instruction Manual

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Fischer 1588GU-22 Brass Tide Clock and Ship's Bell with Wood Plaque User Manual

Fischer Instruments 103PMTD 6" Navigator Series Tide Clock User Manual

ETE-68B4. Infra-red Ear Thermometer

! Warning, refer to accompanying documents.

User Manual PTW-DensiX. D / Di/Zi

U S ER S AN D M AI N TEN AN CE M AN U AL

Fischer 1605GU /8" Solid Brass Nautical Quartz Tide and Time Clock User Manual

Manufactured by: AAA

Ambient Weather GL152-TT Marine Time and Tide Clock User Manual

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

9A5N Solid State CW Paddle

User s Manual. Copyright 2014 Trick Technologies Oy

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

Auto Arm Blood Pressure Monitor

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Ambient Weather TIDECLOCK-25 6" Nautical Brass Quartz Time and Tide Clock with Bayonet User Manual

HI 2314 HI 2315 HI 23151

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

Owner s Manual Humiport 10/20

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

NEULOG OXYGEN LOGGER SENSOR GUIDE

1. Features CONTENTS. English

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

American Weigh Scales, Inc. LB User Manual

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Blood Pressure Monitor Instruction Manual

444C DUAL PERFORMANCE VALUE PACK

.$2;,)*3/6$ USER MANUAL

REF CH-302B IDENTIFICATION OF PARTS

Notes Before Use...2 Notes on charging your watch...2. Your Watch...4 Name of Components...6 About the crown...7

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

Altimeter and Compass Watch Instruction Manual

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

300C/ 800C/ 990C Plus Series

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

12V AIR STATION ALL-IN-ONE

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Operating Instructions Part No

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

VER: A00. Model No:BA2010

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Sports Wrist Digital Blood Pressure Monitor Item #

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

480C DUAL PERFORMANCE VALUE PACK

SVEA II GSM Connector User Manual

Arena by Oregon Scientific

CITIZEN QUARTZ TRAINING TIMER. Model No. ME4xxx Cal. No. D320 INSTRUCTION MANUAL CTZ-B8020

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Constant Pressure Inlet (CCN) Operator Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

REF CH-602B IDENTIFICATION OF PARTS

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OxiQuant S. Operating Instructions

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Short manual testo

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

PitchTracker User Guide. Model: DKPT01 User Guide

metal detector 98760

PitchTracker Softball User Guide

Transcription:

Dual Mode Infrared Thermometer Instruction manual DMT-489 Manual Ver.: 1.0 Issuing Date: 2016/09/26

Thank you for choosing the iprovèn Dual Mode Digital Infrared Thermometer. With its unique technology, the Dual Mode Infrared Thermometer DMT-489 can be used for measuring the body temperature in two different ways. You can either measure the body temperature from the forehead by using the Head-mode or from the eardrum by using the Ear-mode. The Ear-mode can also be used to measure the ambient temperature. The Ear mode is suitable for children older than six months and adults. The Head mode is suitable for people of all ages. To ensure accurate and stable measurements the thermometer performs a self-test every time it starts up. The eardrum and the forehead radiate infrared heat. This thermometer accurately measures the body temperature as it scans the infrared heat radiated from the forehead and the ears. Please read the instructions carefully in order to perform measurements in the most accurate way. Body temperature measurements will NOT be valid or accurate if they are not performed in accordance with the instructions given in this manual. Please keep these instructions handy for later reference. It is our passion to develop high quality products that can easily be operated by every home user and provide the best tailored education accompanying the products. We love to help you get the most out of the product and be more vvhealth aware. Our products are selected, developed and continually improved to meet our clinical standards of quality, durability and consistency, without compromising simplicity for any home user. In order to make sure that what we deliver is exactly what you need, we welcome your feedback. So if you have any issues, questions or recommendations, you would greatly help us when you share your thoughts with us. Visit www.iproven.com iprovén - Professional care brought home iprovén is a Masena Invest company - 2 -

Contents 1. Safety instructions and precautions...4 2. Purpose...4 2.1 Description...5 3. Setup instructions...6 3.1 First use...6 3.2 Replacing Batteries...6 4. Operating instructions...6 4.1 How to get accurate measurements...6 4.2 How to use the Head-mode...7 4.3 How to use the Ear-mode...7 4.4 Memory retrieval...8 4.5 C / F switch...8 4.6 Automatic power off...8 5. Measurement results...8 5.1 Ear-mode/ Ambient temperature mode...9 5.2 Head-mode...9 5.3 Out-of-range temperatures...9 6. Cleaning...9 7. Storage...10 8. Troubleshooting...10 9. Technical Information...11 10. Warranty...12 Symbol Warning Description Electrical waste materials should be sent to dedicated collection points for recycling. Device damage or injuries may be the result of incorrect usage of this product. Please follow the instructions of this manual carefully. Incorrect usage or damage of the product may lead to inaccurate readings. Notice - 3 -

1. Safety instructions and precautions The ear measuring function is not suitable for children under 6 months. In this case we recommend using the Forehead-mode or a rectal digital thermometer with a flexible tip such as the iproven DTK-117A. The device is not intended to serve as a continuous monitoring device. This device is not waterproof. Please keep it away from water or other liquids. Cleaning and disinfection procedures should follow the instructions specified in the cleaning section. Please do not use the product if the temperature sensor of the thermometer shows any sign of damage. Do not try to repair the product if it is damaged. Please contact your supplier. The use of this thermometer is not intended to replace appropriate medical supervision. This thermometer consists of high quality, precise parts. The product is not designed to be impact or shock resistant. Avoid dropping the product or subjecting it to intense shock or vibration. Do not twist the thermometer or the temperature sensor. Remove the batteries if the thermometer will not be used for longer than three months. Warning! This item is not intended to replace insight from a doctor, pharmacist, or other licensed health-care expert. You ought not to utilize this item for self-diagnosis or for dealing with an illness. Get in touch with your health-care supplier quickly if you think that you have a clinical issue. Attention: Electromagnetic interference: this thermomometer contains sensitive electronic components and should not be used under conditions with electromagnetic interference (such as in the immediate vicinity of mobile phones or microwaves). Please dispose of the used products and batteries in accordance with local regulations and requirements. 2. Purpose This thermometer is intended for measuring your own or somebody else s body temperature. It can measure the body temperature from the forehead and from the eardrum. Although the thermometer has undergone clinical tests and is considered safe and highly accurate, it is intended for non-professional home use only. - 4 -

2.1 Description 1. Infrared sensor: (Take off the cover before detecting the eardrum temperature.) 2. Head-button: starts measurement of forehead temperature. 3. Ear-button: starts measurement of eardrum temperature. 4. LCD display 5. Battery cover 2 4 1 3 5 1 1. Ambient temperature 2. Ready for measurement 3. C / F 4. Memory 5. Head-function 6. Ear-function 7. Battery 8. Digits 8 2 6 5 3 7 4-5 -

3. Setup instructions 3.1 First use When using this product for the first time, the battery protection tab must be removed. Remove this plastic tab by gently pulling it out of the battery compartment. 3.2 Replacing Batteries 1. To replace the batteries, follow these instructions: 2. Release the battery cover by gently sliding it down. 3. Take off the battery cover. 4. Replace the AAA-type batteries in accordance to the depicted polarity. 5. Replace the battery cover and make sure the four pins of the cover are in the gaps. 6. Close the battery cover by sliding it upward until you hear a click. 4. Operating instructions 4.1 How to get accurate measurements To ensure accurate measurements, follow these instructions: 1. Please make sure that the temperature sensor is absolutely clean. 2. Please make sure that the device is used in a closed room where there is no strong breeze or draft. 3. Coverage of the forehead and the ears by hair or a hat will make the forehead and the ear warmer; therefore make sure that the forehead or the ear has not been covered during 5 minutes prior to the measurement. 4. Please make sure the forehead is dry and clean before measurement to prevent the sensor from getting stained. 5. Before measuring the ear temperature, please clean the ear canal. 6. Please be aware that intense emotions and exertion before taking a measurement can affect the accuracy of the reading. 7. If the thermometer is transferred from one environmental condition to another that has a different ambient temperature, it is suggested to wait at least 30 minutes to get the thermometer adjust itself to the new conditions in order to get the most accurate reading. 8. Do not hold the thermometer in your hands unnecessarily as it is highly sensitive to heat. Holding the unit for more than 3 minutes can result in inaccurate measurements. - 6 -

4.2 How to use the Head-mode To measure the body temperature from the forehead, follow these instructions: 1. Cover the thermometer with the sensor cap. 2. Start the Three Point measurement by pointing the sensor to one side of the forehead. 3. Lightly touch the skin next to the eye and start holding the Head button. 4. Keep holding the Head button and lightly touch the spot between the eyebrows and the other side of the forehead, next to the eye. 5. The measurement is now completed and you can release the Head button. 6. You can read the temperature from the display. - 7 -

4.3 How to use the Ear-mode 94.28 ºF 98.24 ºF To measure the body temperature from the eardrum, follow these instructions: 1. Take off the sensor cover to expose the sensor probe. 2. Pull the ear backward and upward. 3. Gently insert the sensor into the ear canal. 4. Make sure the sensor points in the direction of the eardrum itself. 5. Press the Ear button once. 6. A beep indicates the measurement is successful. 7. Read the temperature from the display. The most accurate measurement will be obtained when the sensor probe has a direct view of the eardrum (image 2). Straighten the ear canal by tugging the ear upward and backward to get the most accurate measurement (image 2). To measure your own temperature, wrap your free hand around the back of your head and pull your ear upward and backward (image 4). Aged between 6 and 12 months Pull the ear backward (image 3). Aged 1 year and older Pull the ear upward and backward (image 4). 4.4 Memory retrieval Each time successful measurement is performed the measurement data is stored in the thermometer memory. The thermometer memory has a capacity of 20 sets of data. To retrieve stored data sets follow these instructions: 1. Make sure the thermometer is off. If it shows anything on the display, leave the buttons untouched for 10 seconds. 2. Press and hold the Ear-button for 4 seconds until the display shows - - -M. 3. Press the Ear-button once to get the last measurement in the display. - 8 -

4. Press the Ear-button once more to get to data set 2. 5. The data consists of the measured temperature and the saved type of measurement as shown by the accompanying symbols. 6. To shut down the thermometer press the Head-button once. 4.5 C / F switch To switch between Celsius and Fahrenheit follow these instructions: 1. Make sure the thermometer is off. If it shows anything on the display, leave the buttons untouched for 10 seconds. 2. Press and hold the Ear-button for 10 seconds until the display shows - - - C or - - - F. 3. Release the Ear-button. 4. Press the Ear-button once to switch from C to F or from F to C. 5. Wait 5 seconds for the thermometer to save the setting and shut off. 4.6 Automatic power off If the buttons are left untouched for 10 seconds the thermometer will automatically shut down. 5. Measurement results Body temperatures between 36.0 C and <37.6 C or 96.8 F and <99.7 F are considered normal body temperatures. When normal body temperature is measured; one beep will sound and the display will light green. The measured temperature is shown on the display. Body temperatures between 37.6 C <42.2 C or 99.7 F <108 F are considered fever. When the measurement is in this temperature range, the fever alarm will sound; 7 beeps will sound and the display will light red. The measured temperature is shown on the display. 5.1 Ear-mode/ Ambient temperature mode In Ear-mode/ Ambient temperature mode the temperature measurement range is 0.0 C - 100.0 C or 32 F - 212 F. After any successful measurement between 0.0 C < 37.6 C or 32 F < 99.7 F one beep will sound and the display will light green. When the measurement is between 37.6 C and <100.0 C or 99,7 F <212 F, the fever alarm will sound; 7 beeps will sound and the display will light red. The measured temperature is shown on the display. - 9 -

5.2 Head-mode In head-mode the temperature measurement range is 0.0 C - 100.0 C or 32 F - 212 F. After any measurement between 32 C and < 37.6 C or 89.6 F and < 99.7 F one beep will sound and the display will light green. When the measurement is between 37.6 C and < 42.2 or 99.7 F and <108 F, the fever alarm will sound; 7 beeps will sound and the display will light red. The measured temperature is shown on the display. 5.3 Out-of-range temperatures Temperature measurements that are outside the measurement ranges will result in error codes L or H on the display, accompanied by three beeps and the display lighting red for three seconds. L : Measurement is below 32.0 C or 89.6 F in Head-mode or below 0.0 C or 32 F in Ear-mode/ Ambient temperature mode. Please make sure you are following the instructions on how to get accurate measurements. H : Measurement is exceeding 42.2 C or 108 F in Head-mode or over 100.0 C or 212 F in Ear-mode / Ambient temperature mode. Please make sure you are following the instructions on how to get accurate measurements. 6. Cleaning Regularly clean the thermometer with a damp cloth. Do not use alcohol or benzine for cleaning. Prevent the sensor from getting stained by cleaning the ears before using the Ear-mode. Prevent the sensor from getting stained by cleaning and drying before using the Head-mode. Caution: This thermometer is not waterproof! Do not expose this thermometer to water or any other liquid. 7. Storage Store this thermometer at room temperature; the most accurate temperature measurement is obtained when the thermometer has been exposed to the same ambient temperature as the user for at least 30 minutes. Always store this thermometer in the enclosed soft case to prevent it from collecting dust or getting unhygienic. 8. Troubleshooting Error: Display shows ER1 + backlight is red + 3 beeps sound. Meaning: Ambient temperature dropped below 10 C/ 50 F or exceeded 40 C/ 104 F. - 10 -

Desired action: Please store the thermometer at room temperature. Error: Display shows ERC + backlight is red + 3 beeps sound. Meaning: EEPROM data reading error or the correcting process is not finished. Desired action: Please contact your supplier. Error: Display shows low-voltage signal (not blinking). Meaning: The battery voltage is below 2.61V±2%. Desired action: Please replace the batteries according to the instructions. Other signals: L : Measurement is below 32.0 C or 89.6 F in Head-mode or below 0.0 C or 32 F in Ear-mode/ Ambient temperature mode. Please make sure you are following the instructions on how to get accurate measurements. H : Measurement is exceeding 42.2 C or 108 F in Head-mode or over 100.0 C or 212 F in Ear-mode / Ambient temperature mode. Please make sure you are following the instructions on how to get accurate measurements. 9. Technical Information Model: Dual Mode Infrared Thermometer DMT-489 Applicable regulations and laws: ASTM 1965/EN12470-5/GB/T 19146-2010 Temperature units: C/ F, adjustable Measurement range Forehead-mode: 0.0 C-100.0 C / 32.0 F-212.0 F Measurement range Ear-mode: 0.0 C-100.0 C / 32.0 F-212.0 F Precision: ±0.2 C /±0.4 F Display resolution: 0.1 C/0.1 F Latency Time: 1 second Sound: Volume 50 db (Distance from db Volume sensor to thermometer is 10cm) Automatic shutdown function: ±10s Low-voltage display function: low-voltage sign shows when the voltage is below 2.51V±0.15V Memory function: capacity of 20 data sets Current consumption: I stand-by<2μa; I working<0.5ma; I Buzzer on<2ma; I backlight<15ma LED backlight specifications: 1.2cd/m2 Operational conditions: ASTM 10 C-40 C (50 F-104 F)/15-95%RH Operational atmospheric pressure range: 860hPa to 1060hPa Battery: Two 1.5V AAA type batteries Battery life: 3000 measurements Accuracy (for clinical test): maximum allowable error for clinical test= Terror = T1-Tref + T2-Tref 2 0.3 C/0.6 F (for 95%) (T1 and T2 represent temperature value for thermometer under test; Tref represents the constant reference temperature). - 11 -

10. Warranty What does this limited warranty cover? This Limited Warranty covers any defects in material or workmanship under normal use during the Warranty Period. What will we do to correct problems? iprovèn will either replace the product or repair the Product at no charge, using new or refurbished replacement parts. How long does the coverage last? The Warranty Period for this iprovèn product is 730 days from the date of purchase. A replacement product or product part assumes the remaining warranty of the original product purchase. What does this limited warranty not cover? This Limited Warranty does not cover batteries and packaging neither any problem that is caused by: conditions, malfunctions or damage not resulting from defects in material or workmanship. What do you have to do? To obtain warranty service, please contact iprovén customer support: www.iproven.com WAREHOUSE Beaverton, Oregon 9450 SW Gemini Dr Beaverton, OR 97008-7105 Toll free phonenumber US: +18557001668 HEADQUARTERS Ebweg 12D 2991 LT Barendrecht The Netherlands Phone: +31(0)84-8838876 2015-2016. All rights reserved. iprovèn owns and reserves the rights comprised in the copyright of this document. No part of this document may be changed, copied, reproduced, or imitated in any form or by any means without prior written consent of iprovèn. All statements, information, and recommendations in this document are provided AS IS without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. iprovèn reserves the right of final interpretation of this document. - 12 - Version: DMT-489 20160816