Development of small, easy to build and low gas consumming timing RPCs

Similar documents
Long term stability tests of INO RPC prototypes

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

arxiv: v1 [physics.ins-det] 6 May 2016

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Analysis of RPC Performance with Different Gas Mixture

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

arxiv: v1 [hep-ex] 18 Sep 2012

arxiv: v1 [physics.ins-det] 16 Aug 2014

Application Note AN-107

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Performance of a triple-gem detector for high rate charged particle triggering

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

The Transition Radiation Detector of the AMS-02 Experiment

Technical Data Sheet MF010-O-LC

The Experts in Vacuum Solutions

Study of Mixed Gas Flow Pattern Inside RPC

MIL-STD-883G METHOD

ATLAS RPC QA results at INFN Lecce

GOLFER. The Golf Putting Robot

Design and Construction of a GEM-TPC Prototype for R&D Purposes

HASTAC High stability Altimeter SysTem for Air data Computers

Test Plans & Test Results

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Leak Checking Large Vacuum Chambers

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

STRIP EDGE SHAPE CONTROL

Customer Responsibilities

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Study of the IBF of Double/Triple THGEM

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

arxiv: v1 [physics.ins-det] 4 May 2016

Additel 761 Automated Pressure Calibrators

Vibration Analysis and Test of Backup Roll in Temper Mill

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

CBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

LFE OEM TCD - Thermal Conductivity Detector

AMS 6916 Board mount pressure sensor with ratiometric analog output

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

living with the lab control of salinity 2012 David Hall

HumiSys HF High Flow RH Generator

sorting solutions osx separator series

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

RM-80 respiration monitor

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Code Basic module and level control complete with optionals code

Constant Pressure Inlet (CCN) Operator Manual

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Investigation of Cr Etch Chamber Seasoning Pavel Nesladek a, Guenther Ruhl b, Marcel Kristlib b

Improve Process Reliability

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

This test shall be carried out on all vehicles equipped with open type traction batteries.

Additel 761 Automated Pressure Calibrators

SPD Pressure Sensor Families

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Mitos Fluika Pressure and Vacuum Pumps Datasheet

LIFE TIME OF FREAK WAVES: EXPERIMENTAL INVESTIGATIONS

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

LEAP CO 2 Laboratory CO 2 mixtures test facility

Customer Responsibilities

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

Additel 761 Automated Pressure Calibrators Selection Guide

Next Generation Quartz Pressure Gauges

ADVANCES IN NDT TECHNIQUES FOR FRICTION STIR WELDING JOINTS OF AA2024

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

PENETRATION OF N95 FILTERING- FACEPIECE RESPIRATORS BY CHARGED AND CHARGE- NEUTRALIZED NANOPARTICLES

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

Tokyo: Simulating Hyperpath-Based Vehicle Navigations and its Impact on Travel Time Reliability

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

Practical approach and problems in in-situ RGA calibration

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

Vacuum Simulations of the KATRIN Experiment

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Electronic gas volume corrector model DGVC-04

Alice TPC Review Short Summary

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Transcription:

Development of small, easy to build and low gas consumming timing RPCs LabCAF/Univ. de Santiago de Compostela, Spain. E-mail: miguel.morales@usc.es J.L. Rodríguez-Sánchez Department of Particle Phisics/Univ. Santiago de Compostela, Spain. N. Teigel Department of Particle Phisics/Univ. Santiago de Compostela, Spain. D. Ramos Department of Particle Phisics/Univ. Santiago de Compostela, Spain. J. A. Garzón LabCAF/Univ. de Santiago de Compostela, Spain. Timing Resistive Plate Chambers (trpcs) have become a very popular detectors due to the very good timing capability they offer for covering big surfaces at a very good performance/price ratio. However, such kind of detectors could also be very useful for small experimental setups as an alternative to other methods if their very bulky and uncomfortable gas system could be removed. They are not only very cheap, but they can be built very easily with very simple materials and a few fast electronic components. Recently, we have opened a research line aiming to develop small and portable sealed trpcs (srpcs) and to analyze the evolution of their performances along the time. As a first step, we built a few small one-gap and two-gap detectors and we installed in our laboratory a fast and reliable acquisition setup able to monitorize the main features of the detectors on real time. We tested some of the developed detectors under different environments and a comparison was made. XI workshop on Resistive Plate Chambers and Related Detectors - RCP202, February 5-, 202 INFN Laboratori Nazionali di Frascati Italy Speaker. Thanks: Diego Gonzalez (GSI, Germany), Luis Lopes (LIPC, Portugal). c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

. Motivation: Small and portable trpcs Gas ionization detectors are one of the broader family of devices used to detect and to measure the ionization radiation. In some detectors of the family, like the Geiger Muller counters, a sealed volume is filled with the ionizing gas mixture and they are able for working continuously without any visible degradation. Other detectors, like Drift Chambers, have usually a very big size and need very complex gas systems. RPCs usually run quite well while the gas mixture keeps flowing through the chambers. But relying in a bulky gas system [] is not always perfect and some effort has been done to decrease this strong dependence, as recycling gas into the system [2], with benefits for the environment and with long run economic savings. Besides, the lack of portability of such bulky systems do not allow thinking about actual portable RPCs. This work has been focused mainly on the development of small trpcs able to work without the need of gas flowing systems, as the Geiger Muller counters, but offering very good timing capabilities. Table shows a rough comparison of gas constraints of a typical small Geiger counter and a small srpc. Typical magnitudes srpc Geiger Muller Example sizes 40x40x0.3 mm 3 x40 mm 3 Gas Volume (V) 2 mm 3 3 mm 3 Edge surface (S) 50 mm 2 0 mm 2 S/V ratio 0. mm 0 Gas mixture R34a/SF6/Isobutane Neon/Argon + Halogen gas Working mode Avalanche Geiger-Müller Typical Voltage 3000 V 00 V Electric field constant /r Table : Geiger Müller counter and srpc gas chamber comparative. At this first stage our main goal has been exploring the feasibility of such small and autonomous detectors, starting with the analysis of the evolution of the gas chamber responses. Fur such purpose we build the next prototypes:. A one-gap glass RPC, of about 4 4 cm 2, with a 0.3 mm width gas gap 2. Two small two-gaps glass RPCs of 5 5 cm 2 : one of them, a standard open RPC, has been operated inside an aluminum box with continuous gas supply and the second one, a sealed RPC, has been operated inside an air tight box filled of gas to avoid any possible degradation by air contamination. 2. One Gap srpcs Our first step was building a very simple sealed RPC (srpc) chamber of about 4 4 cm 2. One of the first prototypes could be seen in Fig. a: just a small one gap gas chamber, two RC circuits, one high frequency analog amplifier and a PT0 temperature sensor were included in the setup. The chamber was glued with an epoxy mixture over a non reactive polymer to avoid the glue to go inside the gap, and to avoid the chamber pollutes by outgassing from these components. 2

Development of low gas consumming trpcs Later, ten RPCs were handmade by the same method and tested in open gas circuit in order to choose the two better conditioned. Once the electric current felt to a reasonable value of 0.3 na/cm2, input and output gas tubes of one of the RPCs were cut and glued to ensure the gas chamber stayed sealed. Finally, their operational current (Fig. b) and prompt charge distribution (Figs. c, d), were tested under a 22 Na gamma source using the current monitor output of the power supply module and a GHz digital scope respectively. These measurements did not take into account neither pedestal subtraction nor RC overshoot or ionic component, etc. 7e Sealed RPC RPC in gas circuit Temperature 45 T [ C] Current [A/cm²] 40 5e 4e 35 3e 2e 30 e 0 (a) First prototype of a small one gap srpc. 2 3 4 5 time [days] 6 7 8 (b) Operational current and temperature evolution of both a srpc and a reference flowing gas RPC..0e+06 Day 7 Day 6 Day 5 Day 4 Day 3 Events / hour.0e+05.0e+04.0e+03.0e+02.0e 06.5e 06 2.0e 06 Prompt Charge (ADC Units) 2.5e 06 (c) Prompt charge evolutionof a srpc along first week. (d) Evolution of the Prompt charge of the srpc during of three weeks Figure : One-gap srpc analysis: a) detector setup; b-d) current and prompt charge evolution at different time periods. Since the third day, the operational current of the srpc started to grow faster than the one of the reference RPC working in a gas circuit (Fig. b). The same effect could be seen at the prompt charge evolution (Figs. c, d) after a few days working. Gas leaks, internal gas reactions or the outgassing of the materials close to the gap, are the most likely reasons of the observed degradation. 3. Two Gaps srpcs As a second stage, several two-gap chambers of an approximate size of 5 5 cm2, with four readout channels, were built and operated. In this stage we wanted to open the oportunity of 3 6e

(a) Acquisition setup. Figure 2: Two-gap RPCs acquisition and readout layouts. (b) Two-gap RPC configured with two RC circuits. analyzing in the future the behavior along greater time periods and having the chance of analyzing also time and position resolution, crosstalk, etc.. For the sake of a better insight over the process, the data acquisition system was significantly upgraded and improved with offline analysis. 3. Acquisition setup and measurements The same inbox electronics used with the one-gap srpcs was used (Fig.[2b]) to deal with coincidences and parallel event counting. Also, to improve the resolution of the operational current monitoring (Fig.[2a]), an electronic add-on was included. It is remarkable that we reached an almost ten times resolution improvement, from ± 2 na to ± 0.2 na, upgrading our acquisition layout with the help of a not very expensive acquisition board and some amplifiers. It is well known that operational current gives a good insight of the intensity of the gas drifting [3], as long as it is related with the multiplication and attachment coefficient of every specific gas [4]. Therefore, as the gas is the main driven factor of the expected degradation behavior, in order to get some insight of the processes evolving in the gas, a minimum current resolution power is required. Figs. [3a, 3b] show how different gas mixtures give rise to different ionization rates and how different gas degradation evolutions could be discriminated by the new system. In order to analyze the particular effects arising in a sealed RPC and to be sure that no air contamination appear during our measurements we decided to take the data with two alternative configurations:. An open standard two-gap RPC operated inside a normal flowing gas box. 2. A sealed two-gap RPC (srpc) operated in a tight closed box filled with gas. 3.2 Discussion Fig. 4 shows the evolution of the rate and the operational current of both chambers. The inset shows the corresponding evolution of the mean temperature, that at this stage was not stabilized yet in our laboratory, for a period of one week. We observe how the standard RPC seems to stabilize after the first days of operation keeping it s behavior almost constant despite a small decrease in the mean temperature along the whole period. The sealed RPC seems also to keep their performance 4

Current[nA].0 0.4 R34a R34a/SF6/Isobutane (85//5) Current[nA]- Offset.0 0.4 Boxed trpc Day Day Day 20 0.2 0.2 0.0 2.7 2.8 2.9 3.0 3. 3.2 Veff[kV] (a) Operational current dependence with the effective electric field for both pure R34a and standard gas mixture. 0.0 2.6 2.7 2.8 2.9 3.0 3. Veff[kV] (b) Operational current dependence with the effective electric field for both pure R34a and standard gas mixture. Figure 3: Analysis of the operational current behavior with both R34a and standard gas mixture with the Boxed RPC. Rate (Hz).65.6.55.5.45.4.35 Rate Current T ( C) 25.5 25.0 24.5 2 3 4 5 6 7 8 2 3 4 5 6 7 8 (a) Standard RPC..4.3.2. 0.7 Current (na) Rate (Hz) 0.7 0.5 0.4 Rate Current T ( C) 2.5 2.0 20.5 20.0 0 2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 (b) srpc in a gas box..2. 0.7 Current (na) Figure 4: Rate and operational current for the different RPCs setups along one week time. The insets show the laboratory temperature as reference. Probability - day (Events = 2532) day 8 (Events = 853) Probability - day (Events = 2758) day 8 (Events = 904) -2-2 -3-3 0 500 00 500 2000 2500 Prompt charge [ADC units] (a) Standard RPC. 0 500 00 500 2000 2500 Prompt charge [ADC units] (b) Boxed srpc. Figure 5: Evolution of the prompt charge distribution for the different RPC setups. 5

8 6 trpc srpc-box Low/High prompt charge ratio 4 2 8 6 4 0 2 3 4 5 6 7 8 9 Figure 6: High vs Low prompt charge ratio for boxed srpc and standard RPC. Threshold between low and high prompt charge is defined around 300 ADC units. stable during that time. Fig. 5 shows the evolution of the prompt charges for both detectors. Any of the chambers seem to show any significant evolution of the charge although the srpc shows since the first day a significant presence of big charge events. 4. Summary and conclussions One-gap and two-gap sealed RPCs (srpcs) have been built and tested in our laboratory in order to analyze their physical behavior looking at their operational current, rate and prompt charges distributions. At the one-gap prototype, first signs of aging are depicted from the diversion of the operational current from the one provided by a standard RPC. At a second two-gap prototype, their performances were compared with the ones of a reference chamber using an upgraded data acquisition setup and a accurate offline analysis. Preliminary results show that the sealed RPC operated in a box filled with gas, to avoid any air contamination, keeps its performances during at least one week. However, a better temperature stabilization are advisable in order to get more precise conclusions. References [] S.D. Kalmani, N.K. Mondal, B. Satyanarayana, P. Verma, Avinash Joshi, On-line gas mixing and multi-channel distribution system, NIM A, Volume 602, Issue 3, May 2009, Pages 845-849. [2] Dominic M. Rossi and Haik Simon, A closed-circuit gas recycling system for RPC detectors, NIM A, 202, 66, Supplement, pp S230 - S233. [3] S. Ramo, Proc. IRE 27, p.584 (939). [4] Werner Riegler, Christian Lippmann, Rob Veenhof, Detector physics and simulation of resistive plate chambers, NIM A, Volume 500, Issues 3, March 2003, Pages 44-62. 6