WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Similar documents
RM051S-XXX-XX SINGLE POST LIFT / RAM

RM052S-XXX-XX TWO POST LIFT / RAM

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. y Use only genuine ARO replacement parts to assure compatible. RM051S-XXX-XX Single Post Lift / Ram

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. RM052S-XXX-XX Two Post Lift / Ram

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn ).

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

TWO POST RAM PACKAGE 55 GALLON

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Techcon Systems TS1254 Pressure Pot

Installation and Service Manual

GREIG FILTERS, INC. OPERATION MANUAL

Owner's Manual Sealweld SuperSeal II Pump

HPB25 Hydraulic Paving Breaker

Rhino VE CE Bulk Unloader Operator s Card

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Hydraulic Punch Drivers

WW-730. Pressure Sustaining/Relief Control Valve

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

JACK MODULE HYDRAULIC CYLINDERS

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

ModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Smooth Vent Valve. XVD Series

750 Cable Cutter INSTRUCTION MANUAL

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions for NP100 Series Nitrogen Control Panels

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

DK ton, Double-acting, Die-type Crimping Tool

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RS(H)20, 25 USER MANUAL

Pressure Regulators. Operating Instructions. Instrumentation

OPERATING AND MAINTENANCE MANUAL

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

LRS(H)4 Pressure-Reducing Regulator User Manual

MEGR-1912 Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Universal Valve Company Inc

Techcon Systems TS1258 Pressure Pot

Introduction. Part one: Identify the Hydraulic Trainer Components

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

APPS-160 Gen 2 User Manual

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

RHPS Series PRV 2 all types of connections User Manual

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

1200B2 Series Service Regulators. Instruction Manual

RHPS Series PRV 6 User Manual

Hydraulic Punch Drivers

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

WW-720. Pressure Reducing Control Valve

Type CT88 Backpressure Regulator

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Operating Instructions for: PQ120 Pump Series. PQ120 Series Pump SPX

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

HIGH RATE BASKET STRAINER

Operating Instructions Model and Hydrostatic Test Pump

Smooth Vent Valve XVD. Series

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Booster Pump PB4-60 Replacement Kits

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

CSA Sample Draw Aspirator Adapter Operator s Manual

Universal Valve Company Inc

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

INSTRUCTION AND PARTS MANUAL MODELS #13000 TO HYDRAULIC CYLINDERS

Medical Gas Control Panel

Anti-flood device Model B-1

WW-720. Pressure Reducing Control Valve

PDY TON HYDRAULIC CRIMPING TOOL WARNING

RD(H)20/25 Pressure-Reducing Regulator User Manual

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

MEGR-1627 Instruction Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

1.0 - OPENING AND CLOSING THE DOOR

DBML-60/80 Squeeze Tool

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pilot Check Valve: Metal Body Type

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

SPECIFICATIONS CAPACITY

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Pressure Dump Valve Service Kit for Series 2300 Units

Fisher DVI Desuperheater Venturi Inline

3/8" Dr. Air Butterfly Impact Wrench

Specifications Testing & Adjusting Disassembly & Assembly

Instruction Manual. Maximum Operating Pressure 1,500 bar

Transcription:

GSR500 Ram Assembly

General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling pump and follower in and out of a standard 5 gallon / 20 liter pail, or when used as a ram, it can force high viscosity flow able material into the pump inlet. When properly secured this unit has the ability to raise a pump to clear a standard 5 gallon / 20 liter pail. The operator is then able to easily remove the pump from the pail. This lift / ram uses a rotary 3-way control valve which controls the air necessary to raise and lower the lift / ram. This unit includes and auxiliary manual air valve which is used to supply a controlled amount of air pressure to the bottom of the follower plate. When the control valve is in the up position, a small amount of air pressure applied under the follower plate will help raise the follower plate, pump and lift / ram by relieving the vacuum. OPERATING AND SAFETY PRECAUTIONS Read and heed all warnings, cautions and safety precautions before operating. WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION. WARNING: Store and operate the lift on a level surface. WARNING: ANCHOR THE LIFT BASE TO A CONRETE FLOOR OR CART. An improperly secured lift could be unsafe. Do not attempt to use the lift until all possible measures have been take to insure that the lift has been properly installed and the base has been secured. It is the duty of the installer to provide anchor bolts / studs (not included) and for them to be securely embedded in concrete which is more than 2 (50.8mm) thick. WARNING: PREVENT ELECTRICAL SHOCK. Be certain the area above lift is clear of electrical fixtures, devices and wiring. Examine the working area and take necessary action to assure adequate clearance for the lift and pump assembly to raise to the fullest limit and function properly. WARNING: PINCH HAZARD. Follower can descend quickly, causing injury. Keep hands clear when aligning with container. In the raising and lowering function, the lift could get hung up or the descent could be temporarily restricted. The lift could, in some situations, drop suddenly and be hazardous. If the follower plate does not enter the drum properly, DO NOT ATTEMPT TO RE-POSITION IT WITH YOUR HANDS. Release the downward pressure, raise the lift, realign the pail and restart.

WARNING: STAND CLEAR. When raising or lowering the lift keep clear and operate from a safe position. WARNING: HAZARDOUS PRESSURE. Do not exceed maximum inlet air pressure of 125 p.s.i. (8.6 bar). Operating lift at higher pressure may cause lift damage and / or personal injury and / or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized. WARNING: DO NOT EXCEED DRUM PRESSURE LIMITS. Know the pressure limitations of the drum and regulate the air pressure within safe limits when supplying air to the follower plate. WARNING: Place the main valve in the neutral (center) position before air pressure is directly connected or turned on to the system. WARNING: Depressurize the lift / ram before performing maintenance by disconnecting the main air line and rotating the main valve to relieve pressure. CAUTION: Be certain all operators of this equipment have been trained for safe working practices, understand it s limitations and wear their safety goggles / equipment as required. CAUTION: When the lift is in the raised position, the pump mount may be rotated away from the bucket. Rotating the pump 360 degrees may damage tubing. NOTICE: The prevent premature failure of the piston rod and / or seals, it is good practice to keep the piston rod clean and free debris and any other type of contamination. LIFT / RAM INSTALLATION WARNING: Failure to properly install the lift assembly can result in severe injury and property damage. Read the warning above. 1. This lift / ram assembly comes completely assembled. 2. Establish the desired location of the lift / ram and pay special attention to the work area above. This area above the lift must be open, without obstructions and safely away from any electrical devices. 3. THE LIFT MOUNTING BASE PLATE MUST BE SECURELY ANCHORED TO THE CONCRETE FLOOR. The mounting plate itself can be used as a template for establishing the proper anchor locations. 4. Assemble the pump to the pump mounting plate. NOTE: The combined weight of the piston pump and accessories (follower plate, etc.) must not exceed 150 lbs (68.0 kg).

5. Install the pump air hose and follower plate air hose from the control valve. 6. Assemble the vent plug to the follower plate. NOTE: The ram was tested at the factory. The unit should be generally checked over for leakage, because the fittings on the system may have loosened in shipment. NOTE: Re-torque all fasteners before operation. TO RAISE LIFT, (THE FIRST TIME): 1. Take note of the pump / pail clearance above. Be certain the lift / ram is clear of any objects above. Also, refer to Operating and Safety Precautions, found on page 2. 2. Connect the air supply (125 p.s.i. / 8.6 bar maximum) to the air inlet. Adjust the air pressure on the lift / ram pressure regulator (turn knob clockwise) to 20 p.s.i. (1.4 bar). 3. Shift the control valve lever to the up position. 4. Raise the lift / ram high enough to clear the height of the pail. Stop the lift upward travel by moving the control valve lever to the neutral (center) position. 5. Once the lift / ram assembly and pump are in the up position, place and center an opened pail of material on the lift / ram base. 6. Check the vent plug on the follower plate to be sure it easily threads in and out. It is recommended to lubricate the threads of the plug to help prevent possible set up of the compound at this point. TO LOWER LIFT: WARNING: PINCH HAZARD. Follower can descend quickly, causing injury. Keep hands clear when aligning with container. NOTE: Be curtain the follower plate vent plug has been removed so that the air trapped between the follower and the material is allowed to escape from this vent. NOTE: The lift / ram may hesitate momentarily before starting downward. The air pressure inside the post air chamber must decrease before it will begin to descend. 1. Shift the control valve lever to the down position and proceed to lower the pump. 2. Increase the ram air pressure as required until material ozzes out of the vent port. 3. Re-install the vent plug. 4. Open the material by pass valve at the outlet of the transfer pump. 5. Increase the transfer pump air pressure slowly until the pump starts to stroke.

6. Pump until material exits the by-pass valve. 7. Close the by-pass valve. 8. Continue to pump until the material transfer hose is loaded and the pump stalls. 9. Increase the ram and transfer pump air pressures an additional 10-20 PSI, or as required to have a continuous flow / operation of the transfer system to the metering pump assembly. TO RAISE LIFT, (NORMAL OPERATION): 1. Lower the transfer pump air pressure to zero. 2. Shift the control valve lever to the up position. 3. Raise the lift / ram high enough to clear the height of the pail. Stop the lift upward travel by moving the control valve lever to the neutral (center) position. TO CHANGE DRUM: NOTE: The control valve lever should be in the neutral position and the pump air supply valve should be closed. 1. To avoid damage, DO NOT OVER-PRESSURIZE THE PAIL. 2. Open the follower plate air supply valve to allow air under the follower plate. 3. Shift the control valve lever to the up position. 4. Place and center a new pail into position. Remove cover.