EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS

Similar documents
An Experimental Performance Study of Vortex Tube Refrigeration System

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

Development of Two Opposing Nozzle Vortex Tube Using Air as Working Fluid

DEVELOPMENT OF TWO OPPOSING NOZZLE VORTEX TUBE USING AIR AS WORKING FLUID

An Efficient Vortex Tube With Max C.O.P

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

FABRICATION AND OPTIMIZATION OF PERFORMANCE OF VORTEX TUBE PARAMETERS

Experimental Investigation and Modification of Ranque Hilsch Vortex Tube

Fabrication and Experimental Analysis of a Vortex Tube Refrigeration system

Modification and experimental research on vortex tube

An Experimental Investigation of the Optimum Geometry for Energy Separation of the Ranque- Hilsch Vortex Tube

To Study the Effects of Design Parameters on Vortex Tube with CFD Analysis

EXPERIMENTAL STUDY OF THE ENERGY SEPARATION IN COUNTER FLOW VORTEX TUBE

Hermetic Compressor With Improved Motor Cooling

THE EFFECT OF L/D RATIO ON THE TEMPERATURE SEPARATION IN THE COUNTERFLOW VORTEX TUBE

EXPERIMENTAL ANALYSIS OF FIN TUBE AND BARE TUBE TYPE TUBE-IN-TUBE HEAT EXCHANGER

VORTEX TUBE COOLING SYSTEM

Figure 1 Schematic of opposing air bearing concept

OPERATING CONDITIONS OF A RANQUE-HILSH OR VORTEX TUBE

Effect of Cold Fraction and Orifice Diameter on the Performance of Modified Vortex Tube with Dual Forced Vortex Flow

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

PERFORMANCE STUDY OF A MODIFIED RANQUE-HILSCH VORTEX TUBE

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Vortex Tube Short Course February 2017

Concept of modernization of input device of oil and gas separator

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Experimental Investigation of Vortex Tube Refrigeration

SIMULTANEOUS OPTIMIZATION OF HOT AND COLD OUTLET AIR TEMPERATURES OF VORTEX TUBE USING GREY RELATIONAL ANALYSIS AND TAGUCHI METHOD

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Fabrication and Experimental Analysis of Vortex Tube by Varying the Geometry and Material

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

ISSN (Print) : Wasan Naksanee et al. / International Journal of Engineering and Technology (IJET)

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF HELICAL NOZZLES EFFECTS ON THE ENERGY SEPARATION IN A VORTEX TUBE

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Compressors. Basic Classification and design overview

Performance Evaluation of Inverted Triangular Notch and Trapezoidal Plate Fins with Natural Convection

Applied Fluid Mechanics

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Post Graduates, Department of Mechanical Engineering, King College of Technology, Namakkal, Tamil Nadu, India

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

ASSIGNMENT 2 CHE 3473

Continuously Variable Inertance Tubes for Pulse Tube Refrigerators

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

ASSIGNMENT 2 CHE 3473

Integral type Differential pressure flowmeter VNT Series

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Computational fluid dynamics analysis of a mixed flow pump impeller

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Valve Losses in Reciprocating Compressors

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Enter your parameter set number (1-27)

A review on design criteria for vortex tubes

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

CFD ANALYSIS OF CENTRIFUGAL PUMP IMPELLER HAVING DIFFERENT EXIT BLADE WIDTH, EXIT DIAMETER AND TRAILING EDGE BLADE ANGLE TO ENHANCE PERFORMANCE

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

Investigation of Suction Process of Scroll Compressors

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

Design Review Agenda

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

Model 4000 Pressure Controller

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

The Discussion of this exercise covers the following points:

Instruction Manual. Pipe Friction Training Panel

Optimization of rotor profiles for energy efficiency by using chamber-based screw model

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

HON 219 Pressure Reducer (D119a)

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Performance Characteristics of Airlift Pumps with Vortex Induced by Tangential Fluid Injection

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Investigation of failure in performance of linear compressor & its rectifications

Tightening Evaluation of New 400A Size Metal Gasket

Transcription:

International Research Journal of Engineering and Technology (IRJET) e-issn: 9 - Volume: Issue: 9 Sep - www.irjet.net p-issn: 9-7 EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS S.A. Mule, Yogesh Bhosale, Shivraj Bhoi Department of Mechanical Engineering, JSCOE, Maharashtra, India Department of Mechanical Engineering, JSCOE, Maharashtra, India Departments of Mechanical Engineering, JSCOE, Maharashtra, India Abstract: The vortex tube (also called the Ranque- Hilsch vortex tube) is a mechanical device containing an entrance of nozzle with a central orifice, a vortex tube and a cone-shaped valve. A source of compressed gas (e.g. air) at high pressure enters the vortex tube tangentially through the inlet nozzle at high velocity. The expanding air inside the tube creates a rapidly spinning vortex. Once this vortex is set up in the tube, the air near the axis cools down while the air at periphery heats up in comparison with the inlet temperature. This phenomenon is known as temperature separation effect (also called the Ranque- Hilsch effect).in this study, three Ranque-Hilsch vortex tubes were used, which have. mm,.mm, and. mm inside diameter and length/diameter ratio was,, and respectively. Their performances were examined as one of the classical RHVT and other was cold cascade type RHVT. Performance analysis was according to temperature difference between the inlet and the cold outlet ( Tcold). The Tcold values of cold cascade type Ranque-Hilsch vortex tubes were greater than the Tcold values of classical RHVT, which were determined experimentally. The total inlet energy, total outlet energy, total lost energy and energy efficiency of cold stream were investigated by using experimental data. In both the classical RHVT and cold cascade type RHVT, it was found that as fraction of cold flow increases the total energy increases. It was also found that, the cold cascade type RHVT more energy efficiency of cold outlet than the classical RHVT. Excess Tcold value of cold cascade type Ranque-Hilsch vortex tube causes the excess energy efficiency of cold outlet. The range of operating conditions covered; Pressure: - bar to 7 bar; cold fraction: -.to. In order to investigate the effect of materials, vortex tubes of steel, aluminium and PVC are fabricated and tested. Keywords: Vortex tube of steel, Vertex tube of Aluminium and PVC, Compressed air, Ranque-Hilsch effect, Classical RHTV, cold cascade RHVT etc INTRODUCTION The vortex tube also known as Hilsch or Ranque tube is as impel device having no moving parts, whichproduceshotandcoldairstreamssimultaneouslyatits twoendsfromasourceofcompressed air. It consists of along tube having at tangential nozzle near one end and a conical valve at the other end, as shown schematically in Figure. A diaphragm called cold orifice, with a suitable sized hole in its centre is placed immediately to the left of the tangential inlet nozzle. The compressed air is the introduced into the tube through this nozzle. The tangential flow imparts whirling or vortex motion to the inlet air, which subsequently spirals down the tube to the right of the inlet nozzle. Conical valve at right end of the tube confines the exiting air to regions near the outer wall and restricts it to the central portion of the tube from making a direct exit. The central part of the air flow sin reverse direction and makes exit from the left end of the tube with size able temperature drop, thus creating a cold stream. The outer part of the air near the wall of the tube escapes through the right end of the tube and is found to have temperature higher than that of inlet air. Figure Schematic diagram of Vortex Tube OBJECTIVES OF PRESENT WORK In this work, an attempt was made to fabricate and test a counter flow vortex tube using UPVC, Aluminium & mild steel pipe. The performance of vortex tube was evaluated at different working parameters and geometry parameters. a) Design of vortex tube using UPVC, Aluminium & mild steel pipe & UPVC pipe fittings. b) Fabrication of three vortex tubes of different sizes. c) Experimentation for various operating conditions., IRJET Impact Factor value:. ISO 9: Certified Journal Page 7

International Research Journal of Engineering and Technology (IRJET) e-issn: 9 - Volume: Issue: 9 Sep - www.irjet.net p-issn: 9-7 d) Analysis of cascading of vortex tubes. e) Thermodynamic analysis of experimental data. f) Result and discussion on the above trials. DESIGN PROCEDURE The parameters investigated in the study, to understand their inter-relationships and their effect on the performance of the vortex tube are: a) of vortex tube b) Nozzle diameter c) Cold orifice diameter d) Length of the tube e) Area at the hot end. In the present investigation, a nozzle area to Inlet tube area ratio of. ±. for achieving maximum efficiency has been considered, as suggested by Soni and Thomson. The same researchers also mentioned that the length of the vortex tube should be - times the tube diameter. Keeping these suggestions in view, a vortex tube of size miner diameter of UPVC was selected. The vortex tube was mm long pipe. Materials were selected based on easy availability, ease of working, and insulating capability which is necessary for achieving the adiabatic conditions assumed. UPVC has high chemical resistance across its operating temperature range. To obtain optimum design and to perform experiment on vortex tube different diameters of UPVC pipes are selected. Table-: Design Parameters of equipment constructed Tube Inner Cold Plate Orifice Inlet Nozzle No. of Inlet Nozzle mm mm (d) (.d) mm (.d) (depending on flow rate of air) Length: Hot End mm (d-d) Length: Cold End mm (experimental Pressure Range bar - (experimental value) bar value) EXPERIMENTAL SETUP To study the effect of various parameters such as mass flow rates of cold and hot air, cold orifice area and hot end area on the performance of the vortex tube, an experimental set up was prepared as per design described earlier. The temperature of air at cold and hot ends was measured with digital thermometer with an accuracy of ± C. Air flow rotameter are provided for measuring mass flow rate of air. The pressures were measured by pressure gauges. All the instruments were calibrated before the measurements were actually recorded. The different parts of experimental set-up are as below: a) Compressor b) Various types of Vortex Tubes c) Inlet air flow Rotameter d) Cold stream air flow Rotameter e) Thermocouples with digital temperature indicator f) Clamps for mounting Various Vortex Tube g) M.S. frame Fig-: Photograph of experimental setup. TEST PROCEDURE The various parameters, which affect the performance of the vortex tube, were divided into following input and output variables: Input variables: Area of cold orifice, Effective Area of Hot End, Inlet Pressure, Inlet Mass Flow Rate Output variables: Temperature of cold air, cold fraction, and Temperature of hot air. Tests are conducted on experimental setup for various vortex tubes. The steps by steps procedures of each test are as below a) Mount the different diameters vortex tube using clamps provided. b) Provide connection of inlet air hose pipe to st vortex tube on which experiment is to perform. c) ConnectPT- temperaturesensorstocoldendandhotendres pectivelyto st vortex tube on which experiment is to perform. d) Check connections. e) Start the main power supply and check for all electrical supply and display u n i t s. f) Start compressor and Allow compressor to build pressure up to 7 bar. g) Adjust flow rate using flow control valve. h) Adjust mass flow rate of hot air escaping through hot end using conical valve provided. i) Note inlet temp, inlet mass flow rate, cold end mass flow rate, inlet temp, cold stream temp, hot stream temp for different cold fraction by adjusting position of conical valve. j) Repeat the above procedure for another remaining vortex tubes., IRJET Impact Factor value:. ISO 9: Certified Journal Page 77

International Research Journal of Engineering and Technology (IRJET) e-issn: 9 - Volume: Issue: 9 Sep - www.irjet.net p-issn: 9-7 RESULT. Analysis of cold side for different dimensions of UPVC pipe a) Performance Curves of Vortex Tube (Dia..mm) It is found that temperature difference increases with cold fraction reaches a peak value and then decreases suddenly. The temperature difference is lowest for % cold fraction for all cases. The temperature difference also varies with length of vortex tube, increases with decreasing length. The maximum value of temperature difference occurs for -9% cold fraction for all cases L=D L=D L=D... DIAMETER=.mm, PRESSURE= Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P= 7 bar DIAMETER=.mm, PRESSURE= temperature difference also varies with length of vortex tube, increases with increasing length. The maximum value of temperature difference occurs for -9% cold fraction for all cases. DIA.=.mm, PRESSURE=7.... L= L= L= Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P=7bar) L=D L=D L=D Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P=bar)..... COLD L= L= L= c) Performance Curves of Vortex Tube (.mm) Chart&Chart describes variation of temperature difference, (Inlet temperature- cold end temperature) for different cold fractions at inlet pressure of 7 bar & bar respectively. It is found that temperature difference increases with cold fraction reaches a peak value and then decreases suddenly. The temperature difference is lowest for % cold fraction for all cases. The Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P= bar) b) Performance Curves of Vortex Tube (Dia..mm) Chart &Chart describes variation of temperature difference, (Inlet temperature- cold end temperature) for different cold fractions at inlet pressure of 7 bar & bar respectively. It is found that temperature difference increases with cold fraction reaches a peak value and then decreases suddenly. The temperature difference is lowest for % cold fraction for all cases. The, IRJET Impact Factor value:. ISO 9: Certified Journal Page 7

International Research Journal of Engineering and Technology (IRJET) e-issn: 9 - Volume: Issue: 9 Sep - www.irjet.net p-issn: 9-7 temperature difference also varies with length of vortex tube, increases with increasing length. The maximum value of temperature difference occurs for -9% cold fraction for all cases. DIAMETER=.mm, PRESSURE=7... Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P=7 bar) Cascading of L= L= L= Pr=7 bar Pr= bar..... Cold Operating Conditions: Inlet Pressure = 7 bar, Ambient temperature = C Table-: Observations for cascaded configuration for pressure7 bar Sr. m m T T Δ µ i c i c T 9.... 7.... Operating Conditions: - Inlet Pressure = bar, Ambient temperature = C Table-: Observations for cascaded configuration for pressure bar Sr. m m T T Δ µ 9 9. Chart describes the temperature drop for selected cascading arrangement of vortex tube. This configuration gives better results at inlet pressure of 7 bar 9 DIAMETER=.mm, PRESSURE= Chart-: Effect of Length of tube on temp.difference ( Tc) (D =. mm, P= bar) d) Adiabatic Efficiency of Vortex Tubes Chart 7 describes variation of Adiabatic Efficiency for different cold fractions. 7.... L=D L=D L=D Chart-7: Adiabatic Efficiency Chart of All lengths and diameters Vortex Tub By observing the above graphs we decided to cascade three vortex tubes as follows: a) D=.mm,L=D b) D=.mm,L=D c) D=.mm, L=D. So, analysis and graphs of this configuration are as follows: Chart-9: Graph of temperature difference vs cold fraction for selected config.. Analysis of cold side for different materials of vortex tube Analysis is done using different materials of vortex tube i.e. aluminum, mild steel and polyvinyl chloride. Geometric parameters selected are diameter=. mm and Length= D. From Chart vortex tube made from aluminum gives better temperature drop than it can achieve in mild steel and polyvinyl chlorides pipe., IRJET Impact Factor value:. ISO 9: Certified Journal Page 79

International Research Journal of Engineering and Technology (IRJET) e-issn: 9 - Volume: Issue: 9 Sep - www.irjet.net p-issn: 9-7 7) The percentage change in temp of aluminium pipe over steel pipe is increase by %. ) For a diameter of.mm, the percentage change in temp of length D over D is decrease by%. 9) For a diameter of.mm, the percentage change in temp of length D over D is decrease by%. ) For a diameter of.mm, the percentage change in temp of length D over D is decrease by9%. ) The percentage change in temp of cascade pipe over single pipe is increase by 9%. Chart-: Graph of temperature difference vs cold fraction for different materials CONCLUSION ) The effect of various parameters, such as nozzle area, cold orifice area, hot end area and L/D ratio of the tube length to the tube diameter, on the performance of the vortex tube can be investigated. ) There were experimentally tested variations of the cold air temperature Tc and hot air temperature Th with respect to the change of the hot end area for L/D =,, ) Experimentally tested, the temperature differences between the inlet air and the cold exit air, Tc = Ti-Tc, as functions of the cold air mass ratio is defined as follows: µc = mc/mi, where mc is a mass flow rate of the cold air and mi is a total air mass flow rate, with the pressure of the inlet air as a parameter. ) The cold stream temperature increases slightly with µc in the range of about µc = ~ %. And the temperature difference between the inlet stream and the cold one approaches its maximum value in the range of about µc = ~ %. Again further increase in µc cold stream temperature decreases. ) The hot stream temperature decreases slightly with µh in the range of about µh = ~%.Andthetemperaturedifferencebetweent heinletstreamandthehot.one approaches its maximum value in the range of about µc = ~ % Again further increase in µc cold stream temperature decreases. ) The percentage change in temp of aluminum pipe over PVC pipe is increase by %. REFRENCES [] Ranque G. Experiences sur la Detente Giratore avec Productions Simultanees d'un Echappernent d'air Chaud et d'un Echappement d'air Froid. J. de Phys. et Radium Series 7, :,9. [] Hilsch R. The use of the expansion of gases in a centrifugal field as cooling process. The Review of Scientific Instruments, Vol., No., pp -, 97. [] Arbuzov V A, Dubnishchev Yu N, Pravdina M Kh and Yavorskilf N. Observation of large-scale hydrodynamic structures in a vortex tube and the Ranque effect. Technical Physics Letters, Vol., No., pp 9-9, 979. [] Gulyaev A I. Investigation of conical vortex tubes, Inzhenerno-Fiziccheskii Zhurnal, Vol., No., pp -,9. Original in Russian. Translation appears in Journal of Engineeringphysics. [] Singh P K, Tathgir R G, Gangacharyulu D and Grewal G S. An experimental performance evaluation of vortex tube. Journal of Applied Physics, Vol.,. [] Saidi M H and Valipour M S. Experimental modelling of vortex tube refrigerator. Applied thermal engineering. Vol., No. pp 97-9,. [7] Stephan K, Lin S, Durst M, Hunag F and Seher D. An investigation of energy separation in a vortex tube. International Journal of Heat and Mass Transfer, Vol., No., pp -,9. [] Ting-Quan MA, Qing-Guo, Jian YU, Fang YE, and Chong-Fang. Experimental investigation on energy separation by vortex tubes. th international Heat Transfer Conference,, Paris. [9] Soni W J, Thomson. Optimal design of the Ranque- Hilsch vortex tube. Journal of Heat and Mass Transfer Transactions of the ASME, pp -7, 97 [] C P Arora..Refrigeration & Air Conditioning. Second Edition., IRJET Impact Factor value:. ISO 9: Certified Journal Page