Studying Vault Board Behavior: A Preliminary Look

Similar documents
Analysis of stroke technique using acceleration sensor IC in freestyle swimming

A COMPARISON OF SELECTED BIOMECHANICAL PARAMETERS OF FRONT ROW SPIKE BETWEEN SHORT SET AND HIGH SET BALL

Generation of Robot Motion Based on Measurement of Human Movement. Susumu Sakano 1, Satoru Shoji 1

COMPARATIVE STUDY OF KICKING PERFORMANCE BASED ON DIFFERENT KIND OF SHOES

KINEMATIC ANALYSIS OF SHOT PUT IN ELITE ATHLETES A CASE STUDY

KASAMATSU VERSUS TSUKAHARA VAULT

Impact Points and Their Effect on Trajectory in Soccer

1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia,

Twisting techniques used in freestyle aerial skiing

Investigating the Bubble Behavior in Pool Boiling in Microgravity Conditions Thilanka Munasinghe, Member, IAENG

Putting Report Details: Key and Diagrams: This section provides a visual diagram of the. information is saved in the client s database

Sample Solution for Problem 1.a

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

DP Ice Model Test of Arctic Drillship

Development of a load model for men-induced loads on stairs

Open Research Online The Open University s repository of research publications and other research outputs

FORCE MEASUREMENT. Part I - Jim Joy Presentation 12/11/09 by Jim Dreher and Coleen Fuerst

Swimming Stroke Mechanics

Application of pushover analysis in estimating seismic demands for large-span spatial structure

A MODEL FOR ANALYSIS OF THE IMPACT BETWEEN A TENNIS RACKET AND A BALL

BIOMECHANICAL MOVEMENT

Effects of foot-pedal interface rigidity on high frequency cycling acceleration. John Romanishin

PAPER 2 THEORY QUESTIONS

ZIPWAKE DYNAMIC TRIM CONTROL SYSTEM OUTLINE OF OPERATING PRINCIPLES BEHIND THE AUTOMATIC MOTION CONTROL FEATURES

#19 MONITORING AND PREDICTING PEDESTRIAN BEHAVIOR USING TRAFFIC CAMERAS

APPROACH RUN VELOCITIES OF FEMALE POLE VAULTERS

Phys 201A. Lab 6 - Motion with Constant acceleration Kinematic Equations

Walking Simulator Mechanism

Body Stabilization of PDW toward Humanoid Walking

Equine Cannon Angle System

HAWK-EYE INNOVATIONS LTD THE HAWK-EYE TENNIS COACHING SYSTEM

WAVE IMPACTS DUE TO STEEP FRONTED WAVES

Science&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching

ANZAI AZ-733VI. Respiratory Gating System. since 1976

Aerodynamics Principles

Techniques Used in the Triple Jump

Optimal Football Pressure as a Function of a Footballer s Physical Abilities

A QUALITATIVE ANALYSIS OF THE HIGH RACQUET POSITION BACKHAND DRIVE OF AN ELITE RACQUETBALL PLAYER

2017 National Qualifier and Hopes Classic Competitions GENERAL & TECHNICAL INFORMATION

2018 American Classic/Hopes Classic GENERAL INFORMATION

G.C.E (A/L) Examination March In collaboration with

Statistical Analysis Project - How do you decide Who s the Best?

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

In addition to reading this assignment, also read Appendices A and B.

DataCan. Linewise System. Description. Hardware. Applications

Use of On-Body Sensors to Support Elite Sprint Coaching

Dillon Thorse Flow Visualization MCEN 4047 Team Poject 1 March 14th, 2013

GROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

Introduction to Waves. If you do not have access to equipment, the following experiments can be observed here:

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Subsonic Wind Tunnel 300 mm

Biomechanical analysis of spiking skill in volleyball

TEMPORAL STRUCTURE OF A LEFT HAND TOSS VS. A RIGHT-HAND TOSS OF THE VOLLEYBALL JUMP SERVE

Preliminary design of a high-altitude kite. A flexible membrane kite section at various wind speeds

Project Title: Pneumatic Exercise Machine

Diving Questions PLAY AND PAUSE. Open the video file 10m Tuck

Measurement of court speed and bounce. Rod Cross, Physics Department, Sydney University 2nd July 2006

Acute Changes to Foot Strike Pattern Effects on the Biomechanics and Ground Reaction Forces in Collegiate Recreational Runners

THREE DIMENSIONAL STRUCTURES OF FLOW BEHIND A

Add this important safety precaution to your normal laboratory procedures:

SHAFTING VIBRATION PRIMER

Road Data Input System using Digital Map in Roadtraffic

Experiment of a new style oscillating water column device of wave energy converter

SERIES SIMULATORS SIMULATORS SIMULATORS

The Soccer Guy. By Marcus Hilgers Faisal Ahmad Jacob Borer

Essential ski characteristics for cross-country skis performance

Fig. 2 Superior operation of the proposed intelligent wind turbine generator. Fig.3 Experimental apparatus for the model wind rotors

ScienceDirect. Rebounding strategies in basketball

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Modeling of Hydraulic Hose Paths

Q1.Four students tested their reaction times using a computer program. When a green light appeared on the screen the students had to press a key.

Gait Analyser. Description of Walking Performance

Questions. Background. Equipment. Activities LAB 3. WAVES

Texas High School Women s Gymnastics Rules These rules will be maintained and updated on the THSGCA website, HIGH SCHOOL VAULT VALUES

POWERED FLIGHT HOVERING FLIGHT

WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS

The Study of Bubbly Gas-Water Flow Using

Kinematics Lab #1: Walking the Graphs Results and Discussion. By: Alex Liu Teacher: Mr. Chung Due: October 28, 2010 SPH3U1-01

Video recording setup

Body conguration in multiple somersault high bar dismounts

Biomechanical Analysis of a Sprint Start. Anna Reponen JD Welch

Goodyear Safety Research Project 2008 Presentation by Competitive Measure at the FEI Eventing Safety Forum. Presented by Tim Deans and Martin Herbert

Waves. harmonic wave wave equation one dimensional wave equation principle of wave fronts plane waves law of reflection

Vaulting. Level 10 - All Vaults from Groups 1-5 Allowed Bonus Vaults: If performed successfully, selected 10.0 SV vaults receive +0.

Exploring the relationship between the pressure of the ball and coefficient of restitution.

14 The Divine Art of Hovering

ITTC Recommended Procedures and Guidelines

E/ECE/324/Rev.1/Add.47/Rev.9/Amend.2 E/ECE/TRANS/505/Rev.1/Add.47/Rev.9/Amend.2

Analysis of Movement

Updates and Clarifications

Development of an end-effector to simulate the foot to ball interaction of an instep kick in soccer

Root Cause Determination of Excessive Hull Vibration On a First-In-Class Tugboat Design By Wylie Moreshead, P.E., Azima DLI

A differerential pressure anemometer

EXAMINATION OF AE WAVE PROPAGATION ROUTES IN A SMALL MODEL TANK

CT PET-2018 Part - B Phd COMPUTER APPLICATION Sample Question Paper

VALVE CRITICALITY MODELING

Lesson: Airspeed Control

Questions OSCILLATIONS AND WAVES

ADVANCES IN NDT TECHNIQUES FOR FRICTION STIR WELDING JOINTS OF AA2024

Transcription:

Studying Vault Board Behavior: A Preliminary Look Wm A. Sands, Ph.D., Head Sport Biomechanics and Engineering, U.S. Olympic Committee Sarah L. Smith, Ph.D., Senior Biomechanist, U.S. Olympic Committee Thomas Piacentini, Intern, Sport Biomechanics and Engineering The purpose of this study was to provide some preliminary information on the vault board. These initial results are part of a much larger ongoing study of the behaviors of gymnastics apparatuses. The vault board is used for vaulting take-offs, drills and skills for tumbling and vaulting, and other apparatus mounts. The vault board has undergone a limited amount of scrutiny with regard to its behavior (Greenwood & Newton, 1996; Fie, 1984; Sano, Ikegami, Nunome, Apriantoni, & Sakurai, 2004). However, the interaction of the vault board with gymnasts has scarcely been addressed. The following information is largely descriptive and meant to portray vault board movement behaviors during vaulting takeoffs and our current preliminary efforts at studying the vault board. Vault board behavior was analyzed by two primary means: high-speed video and magnetic motion tracking. Video analyses of vault board behavior were undertaken using high-speed video (NAC HSV 400) at 200 frames per second. Four reflective markers were placed on the board as shown in Figure 1. The reflective markers were video taped and then rendered to x-y coordinates (two-dimensional analyses) via Peak Performance Technologies software. The raw data were analyzed for position, displacement, and velocity information. Figure 1 shows the vault board response that occurred when a young male gymnast performed a handspring vault over a vault table. Note that the response of the board indicated an intermediate recoil and a complex wavelike movement of the upper surface of the board that resulted in tipping of the board from side to side as well as a whipping movement of the most forward board marker.

Intermediate Board Recoil Figure 1. Note the white markers attached to the side edge of the vault board. These markers permit automatic digitizing of the vault board movements during a take-off impact. Note that the impact resulted in a side-to-side tipping of the vault board and a fore-aft complex wave-like motion. The graphic depictions below the photos show the traced movements of the four markers. The upper-left marker that corresponds to the top forward corner of the vault board shows an intermediate recoil. The 2D Raw Coordinates Spread Display plots each point while moving the image sequentially to the right to prevent marker positions from being drawn on top of each other. The Spread Display shows most clearly the intermediate recoil of the upper-left marker of the vault board. In addition to the high-speed video of the vault board movement, later work has taken advantage of a magnetic motion tracking system. The Liberty TM magnetic motion tracking system was provided by Polhemus, Inc. and the software was provided by Advanced Motion Measurement, LLC. Eight magnetic sensors were taped rigidly to the side edge of the top and bottom surfaces of the vault board. These sensors provide six degrees of freedom sensing which means that the sensors are able to record positions in x, y, and z planes; the sensors also provide angular position and displacement information in a roll, pitch, and yaw type format. These sensors provide sub-millimeter precision and sample at 240 Hz. The precision was so great that the gymnast s last few running steps were detected by the sensors due to the deformation of the wooden gymnasium floor as the gymnast approached. Figure 2 shows the sensor configuration. The magnetic motion tracking system is important due to the issue of the vault safety mat that will be used for Yurchenko-type vaults. Reflective video makers will be obscured by the safety

mat making the detection of board motion impossible by traditional video means (Figure 3). Figure 2. Magnetic sensors are shown taped to the side edge of a vault board s upper and lower surfaces. Note the transmitter for the magnetic sensors is shown on the tripod to the left of the vault board. The magnetic field created by the transmitter is sensed and the relative positions of the sensors are recorded by a laptop computer.

Figure 3. The vault board is shown with the safety mat surrounding the board on three sides. An example of the type of data provided by the magnetic sensors is shown in Figures 4 and 5. Both figures show screen images of the Advanced Motion Measurement software with the sensor triads depicted along with a graph of the Z direction (up and down) sensor positions for six of the eight sensors. Figure 4 shows the results of a takeoff on one type of vault board. Figure 4. Sensor configuration and sensor movement are shown above. The graph shows the movement of sensors 1 through 6. Note that the take-off from this board presented an intermediate recoil that occurred during the initial descent of the magnetic sensors during the initial impact of the gymnast onto the vault board.

Figure 5 shows the movement of the sensors on a different type of vault board. Note that the take-off from this board does not show an intermediate recoil. Figures 4 and 5 were the result of the same athlete performing the same handspring vault. Figure 5. Sensor configuration and movements (graph above) are shown.

Figure 6 shows the vault board response for a Yurchenko vault. The Yurchenko vault take-off from the vault board is usually performed with a take-off impact much closer to the higher end of the board (i.e., closer to the vault table). This type of take-off is performed after a round off which serves to turn the gymnast 180 degrees from his/her run, and thus the athlete is facing backward when contacting the board. Figure 6. Yurchenko take-off. Note that the vault board movements are more subtle and displacement patterns show that the gymnast s take-off has a more prolonged contact time with the board.

To conclude this initial discussion of vault board behavior, Figures 7 and 8 display the vault board recoil patterns as depicted by the sensors. Note that the recoil movements of the two measured vault boards are quite different for the same type of vault performed by the same gymnast. One of the boards (Figure 7) shows the sensors rising almost directly vertical. Figure 8 shows the sensors rising vertically initially and then move obliquely backward. At present, whether one movement is superior to the other is unknown.

Figure 7. Vertical recoil actions of one type of vault board. Note that the sensors rise almost directly vertical during recoil. Figure 8. Note that the triads move vertically during the early phase of the major board recoil, but then the triads move rearward and upward during the latter phase of the recoil.

Figure 9 shows the displacement of sensors during a Yurchenko vault take-off in a multiimage format. Note that the forward-end (rightmost) of the board (Sensor 1) is deflecting the farthest and this corresponds to the take-off impact striking the forward end of the board. This deflection pattern is in marked contrast to the typical type of impact pattern that is observed when gymnasts perform a handspring type vault where board contact occurs nearer the rear or leftmost part of the board (e.g., sensors 3 and 4).

Figure 9. Yurchenko vault, initial impact. Note that Sensor 1 is descending farther and more rapidly than the remaining sensors. This indicates the position of the feet where the gymnast contacted the board. Conclusion This preliminary report has shown that the two types of vault boards analyzed thus far behave differently. Moreover, it was shown that individual athletes often have markedly different impact signatures with regard to vault board movements. In order to determine if these differences in both athlete and vault board behaviors are good or bad, further analyses will be necessary. Moreover, the results indicated that the board actions, gymnasts impressions of these actions, and resulting take-off actions are often counter-intuitive and may defy conventional coaching wisdom. These analysis techniques will be applied to the floor exercise apparatuses and balance beams. The capabilities of these measurement techniques look very promising. Reference List Fie, J. (1984). Synthetic boards spring past wood. Technique, 4(1), 12-13,19. Greenwood, M., & Newton, J. W. (1996). Direct force measurement of the vault take-off in gymnastics. J. M. C. S. Abrantes Proceedings XIV International Symposium on Biomechanics in Sports (pp. 332-334). Lisbon, Portugal: Edicoes FMH Universidade Tecnica de Lisbon. Sano, S., Ikegami, Y., Nunome, H., Apriantoni, T., & Sakurai, S. (2004). An accurate estimation of the springboard reaction force in vaulting table of gymnastics. Proceedings of XXII International Symposium of Biomechanics in Sports University of Ottawa, Ottawa, Canada: Faculty of Health Sciences, University of Ottawa, Ottawa, Canada.