Hydro Microdermabrasion and Oxygen Spray Instruction

Similar documents
DM-02A OXYGEN & BIO SKIN LIFTING BEAUTY EQUIPMENT

2D HIFU Machine. User Manual

LUNA V. User Manual. Warning

AIR PRESSURE MASSAGER #Unwind

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

Warning. This product does not belong to medical, please don t use for disease treatment!

1. NAME OF THE MEDICINAL PRODUCT. Medicinal Air, Air Liquide 100%, medicinal gas, compressed. 2. QUALITATIVE AND QUANTITATIVE COMPOSITION

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Oxygen Concentrator Instruction

Introduction of HIFU

UNOSETION+Bipolar &BIO + Quadrupole &BIO + Quadrupole Vacuum + Sextupolar RF Slimming Machine. Model: YH-5403

Typical fields in which hyper baric oxygen therapy is applied

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

SUMMARY OF PRODUCT CHARACTERISTICS

USER MANUAL LTH-255A Hand Piece

CO 2 and O 2 scrubbers

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

oxyoasis oxygen facial system

AND OPERATION INSTRUCTIONS

Safety Rules for the Science Lab

Optimized Oxygen System for Fresher Life

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Infrared Pressotherapy Lymphatic Drainage Equipment USER MANUAL. Many thanks for purchasing our company s product,please kindly read the manual

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Refresher

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

HKS306 SLIMMING FAST USER MANUAL

Instructions for use Compressed air injector with water trap

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

MATERIAL SAFETY DATA SHEET

Magic Carbo CMV1.3. Carboxytherapy Equipment. User Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Sample Concentrator SBH CONC/1 Instructions for use

B E C O M E A N E V E N B E T T E R Y O U

Material Safety Data Sheet (MSDS) Test liquids TL1, TL2, TL3 & TL4

3. HEALTH INFORMATION AND PROTECTION

OPERATION MANUAL NTF-15

Flow meter. bellow vaporizer. APL valve. Scavenging system

SAFETY DATA SHEETS. This SDS packet was issued with item: N/A

O 2 For Health. The Best In Oxygen Therapy. **MOST IMPORTANT. First 3 charges must be for over 8 hours even if the light turns green.

The MSDS format adheres to the standards and regulatory requirements of the United States and may not meet regulatory requirements in other countries.

B E C O M E A N E V E N B E T T E R Y O U

OPERATION MANUAL NTF-60 Plus

Spa Start Up & Maintenance

MSDS CODE: ADDRESS: NFPA HAZARD IDENTIFICATION DEGREE OF HAZARD HAZARD RATINGS EMERGENCY TELEPHONE NO.:

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

VAPOMATIC ANESTHETIC VAPORIZER

Installing ASI Umbilical Delivery Systems

1020 Industrial Drive, Orlinda, TN fax

Safety Data Sheet Lyden Oil Company

MATERIAL SAFETY DATA SHEET "W" TEST SOLUTION NFPA HAZARD RATINGS* 2 Moderate health hazard 3 Highly flammable SECTION 1: PRODUCT INFORMATION

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

2 Sentry MCL Installation, Operation & Maintenance

1. Label a diagram of the respiratory system. Objective sheet 3 Notes

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

MATERIAL SAFETY DATA SHEET. Section I Identification. Section II Hazardous Ingredients

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

Hot Water Stationary Unit

MATERIAL SAFETY DATA SHEET

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

3. HEALTH INFORMATION AND PROTECTION

BS ml Bottle Sampling Unit

Student Information Document

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Operating Instructions and Parts Manual 24529

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Wolfson Campus Natural Science Department. Biology Laboratory. Student Safety Contract

SAFETY DATA SHEET PRODUCT NAME Sulfur hexafluoride 1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST :

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Safety Data Sheet Lyden Oil Company

SCUBA - self contained underwater breathing apparatus. 5 million sport scuba divers in U.S. 250, ,000 new certifications annually in U.S.

MATERIAL SAFETY DATA SHEET A Colorant

Cold Weather Emergencies

FORM 125: SAFETY DATA SHEET - DAMPERS

OPERATING MANUAL LO-CROSS-FLOW CF M

Frigitronics CRYO-PLUS

1/4 SHEET PALM SANDER

User s Manual EN. 1. General Details Safety Warnings... 3

First Aid - immediate care that is given to the victim of an injury or illness until experts can take over - Oftentimes, it s the difference between

Experience the healing powers of PURE OXYGEN. Hyperbaric Oxygen Therapy is as natural as BREATHING

3. HEALTH INFORMATION AND PROTECTION

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

2008 by Controlmatik ABW

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

My CoughAssist. A patient guide to CoughAssist T70. Please visit

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

Mass Spec will not Autotune

MATERIAL SAFETY DATA SHEET

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Understanding Tracheostomy Care

ATMOS Wound Therapy. The choice is yours! ATMOS S 041 Wound ATMOS S 042 NPWT. MedizinTechnik

Issue Date no data available Revision date 04-Dec-2012 Version 1. Section 1: PRODUCT AND COMPANY IDENTIFICATION

Transcription:

Hydro Microdermabrasion and Oxygen Spray Instruction

Technical Parameter Input: 220V/50HZ 110V/60HZ Power: 150VA Vacuum: 5~70kg/ Theory of hydro dermabrasion Spa skin beauty machine completely changed the traditional way, which is hand-cleaning skin relying on individual s practice skills, SPA skin beauty machine, using vacuum suction mode controlled by intelligent process, through the combination of products and equipment, deep cleaning the skin and pores off horny, acne, blackheads and other impurities in very short period of time. Effect of hydro dermabrasion: Improve the deep absorption of nutrition products, promote pores tighting, smooth skin, increase skin moisture, and make your skin whitening, moisturizing and good texture, reach deep cleaning, cleaning skin stratum corneumlayer, cleaning blackhead. Attention of hydro dermabrsion: 1, do not use on wound 2, pour out the water in the waste recycling bottle in time, to avoid damage caused by overflowing. 3, different size of heads can be flush with water directly, then soaked with 75% alcohol. Forbidden group of hydrodermabrasion people who has fever, infections diseases, acute diseases people with hemorrhagic desease, trauma, vascular rupture, skin inflammation, skin disease

Accessories of hydro dermabrsion Vacuum SPA heads Oepration of hydro dermabrasion 1, connect the accessories to the hose and place them well Insert the inlet transparent tube of he vacuum SPA handle Insert the outlet transparent tube of the vacuum spa handle with water regulation valve Insert the power supply line 2, unscrew the liquid bottle in a clockwise direction, and put appropriate liquid into the bottle 3, fasten the liquid bottle in a clockwise direction, notice the sealing ring. 4, choose the vacuum work head, and connect to the vacuum spa handle 1# work head for clearing comedones, whitehead and acne 2# work head for deep cleaning of normal skin, uneven color and dark skin, dry aging skin 3# work head for thick cuticle, coarse pores, oil over secretion skin. 5, turn on the general power switch 6, adjust the vacuum regulating knob (left-small, right-big) to the appropriate vacuum 7, adjust the water regulating knob (left-small, right-big) to the appropriate amount of water 8, beautician hold the vacuum spa handle on skin for a while until the water flow into the work head, and then drop some water on skin by points, to make the skin surface wet, and then apply cleansing product on the skin, and move the vacuum work head on skin back and forth 9, adjust the water regulating valve to opened and closed

10, Check the waste water recycling bottle, before turn on the machine, if the bottle is full, please clean it first. Cleaning method: unscrew the waste water recycling bottle in a clockwise direction, cleaning the waste water, then fasten it in a anticlockwise direction. Source Spa theory and the effect of Oxygen spray Source Spa is the use of the high pressure physical separation method to extract the oxygen in the air, making 99% of pure oxygen, is a highly efficient, environmental protection equipment. Cooperate with specially designed nozzle, spray gun to the skin in oxygen, oxygen injection and smelling oxygen injection triple way directly into the skin wrinkles and dry place, make the skin rapid absorption of oxygen, increase the activity of human cells, accelerate metabolism, achieve various disagree with unexpected therapeutic effect. oxygen is the key to human life energy material. 1) oxygen can promote the regeneration of the epithelium of collagen fiber and capillary, conducive to the recovery of the organization. 2)overcome the hair follicle and surrounding tissue hypoxia state, improve aerobic metabolism. Promote the circulation of intradermal ischemia hypoxia group to blood and oxygen, accelerate the hair regeneration. Promote the atrophy of hair follicle returned to normal. Effectively restrain the growth of the acne propionic acid bacillus (anaerobic bacteria), improve the inflammation of the skin. 3) care at the same time, the inhalation of high concentration of oxygen, but also to the health of the body. 4)high purity, high active, natural and safe. Effects 1, replenish oxygen to skin quickly, back to life; 2, activate cells, restore elasticity; 3, remove wrinkles, anti-aging; 4, hydrating whiten and smooth the skin; 5, to remove facial defects, dodge various spots; 6, collaterals, and promote circulation, strengthen metabolism; 7, relaxing, reduced pressure regulation, adjusting endocrine, the symptom such as insomnia, upset, headaches, irritability, fatigue; Treatment

1, high pressure oxygen injection treatment: Through instruments, pressure device with activity in the form of rhythm massage essence of concentrated ingredients, make skin pure oxygen, oxygen at the same time, along with treatment products and active substances, into deep skin, treatment, and improve the hypoxia caused by wrinkles, relaxation, pigmentation skin problems. 2, oxygen injection treatment: Oxygen and course of product by spray a mixture of oxygen lance into mist sprayed on the surface of the skin, absorbed by the skin micro circulation, treatment of pruritus, sensitive skin, neurodermatitis, contact dermatitis, acne skin. Suitable People: 1, pregnant or lactating women. 2, heart disease or device equipped with cardiac pacing. 3 patients, surgical wound hasn't healed. 4, epilepsy, severe diabetes, patients with hyperthyroidism. 5, malignant tumor patients, patients with hemophilia or severe bleeding. 6, with caution in patients with skin diseases and infectious diseases. Attenttion 1, Please clean treatment head with clear water will be removed and properly kept. 2, Before use must be used with grounding of the plug and ensure that instrument outlet has real grounding. 3, to ensure the instrument is voltage adapter, if the local power supply voltage is not stable, we recommend that users increase the power matching between grid and instrument stabilized voltage supply. 4, in order to the treatment effect and ensure the normal service life, please unified use the original manufacturer to provide or recommend the use of specified accessories. 5, instrument shall not put wet place in or near water, also do not want to pass the instrument directly exposed to the sun to the place. 6, Do not place the machine near strong heat source, because it may affect the service life of equipment and normal use. 7, treatment requires the product to be used as the standard, please don't use too much product, so as not to reduce sucked into an instrument filters and the service life of the instrument. 8, please don't in the eyes, thyroid, parathyroid gland, testicle, pregnant women use in areas such as the abdomen and atrial pulse generator. 9, for pure oxygen is strong combustion-supporting gas, please pay attention to when using this instrument so far away from fire and heat source, lest cause an accident. 10, when using the instrument does not have a guest, please shut off the power switch apparatus, and ensure that personnel closed before you leave after daily use instrument of total power supply, ensure the safety of electrical products. 11, in strict accordance with the manual instructions use equipment or training equipment operators.