The instrument should have a mass range from 2 to 2000 m/z or better Interface

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

Prep LC Training Manual

Prep LC Training Manual S.V.

CMA4000 Specifications

HPLC. Solvent Delivery Module Systems

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

GCMSD-Headspace Analysis SOP

Setting a New Standard in Flash Chromatography Performance

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

FTC130 Transmitter. Operating Manual

LUMAZOTE T ECHNICAL BRO CHU RE

Customer Responsibilities

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Electronic Volume Correctors

5890II GC Standard Operating Procedure 9/2/2005

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Mass Flow Controller (MFC) for Gases

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Automatic Isokinetic Sampler. ST5 Evo

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Pneumatic high-pressure controller Model CPC7000

Design Features. General Description

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Peak Biotech - Company & Product Presentation

HumiSys HF High Flow RH Generator

159 mm 154 mm. Subject to changes 10/2012

PRC CO ² -LASER PRESENTATION

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

NGN Series nitrogen generator

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

For Multi-Parameter Meters see mvx

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Mass Flow Controller (MFC) for Gases

SOP: Buck Scientific BLC-20P HPLC Operation

Complete Range of Force Tensiometers

Department of Nephrology

Mass Flow Meter (MFM) for Gases

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Gas Network Craftsperson

AKTA pure 25 New Owner s Intro

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Pneumatic high-pressure controller Model CPC7000

Instruction Manual. BZ7002 Calibration Software BE

This test shall be carried out on all vehicles equipped with open type traction batteries.

Customer Responsibilities

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Customer Responsibilities

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Panther 5 Acute Care Ventilator

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

For Multi-Parameter Meters see mvx

Rimage Everest 600 Thermal Retransfer Printer

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

TGA100A Trace Gas Analyzer Overview

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Model EXAxt AV550G. Averaging Oxygen Analyzer

SonoMeter 30 Energy Meters

The latest automotive systems require innovative leak test methods and fixturing.

The instrument will process the samples one by one till all the samples have been cleaned up.

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Convergent Technologys product overview

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Major Design Features

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

HYDRAULICS. H89.8D - Hydraulic Bench

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Code Basic module and level control complete with optionals code

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

RM-80 respiration monitor

Osmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin

SHIMADZU LC-10/20 PUMP

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Quick Start Guide for SA-9600 Series Surface Area Analyzer

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Transcription:

Sl No UNIVERSITY OF MYSORE DOS in Food Manasagangotri, Mysore 570 006. TENDERS FOR THE SUPPLY OF EQUIPMENTS, NETWORKING & COMPUTATIONAL FACILITIES FOR UNIVERSITY OF MYSORE (UNDER UGC XI SCHEME) INVITATION FOR TENDERS ( I F T ) ( SHORT TERM ) No. MGFSN/565/ 2010-11, 06-01-2010 Ref: DC Office Bulletin No. 39/2010-11, 7.01.2011 Supply of Approxim EMD reference & Good/Equipment ate Value Amount Details (Rs) (Rs) date Name of the Global Positioning and time for Date and time of and time Opening er System receipt of issue for receipt date and application of blank of filled time PARA for Blank METER 1 2 3 4 5 6 7 8 9 10 11 12 1 The Chairpers on, DOS in Food University of Mysore, Mysore- 570 006 MGFSN/ 565/ 2010-11 dated 06.01.2011 HPLC SPECIFICATION (For Binary system):- Should have an easy to read display and keypad user interface Stepper motor control of dual reciprocating pistons should provide pulse-free solvent delivery over the flow of 0.001-10.000 ml/min Programmable Compressibility Compensation 16.00 25,000/ - 12 18' 28 N 76 38' 21 E 17.01.2011 5.00 pm 20.01.2011 5.00 pm 24.01.2011 5.00 pm 25.01.2011 Receiving Authority The Chairpers on, DOS in Food University of Mysore, Mysore- 570 006

Flow range of 0.000 to 10.000 ml, in 0.001 ml/min increments, std 100 µl heads Pump control module should have more than 7 Gradient curves for efficient method development Should be upgradable to operate at semi preparative scales. Should have automatic purging, programmable flow calibration and on board diagnostics MANUAL INJECTOR 20 ul standard loop (changeable 5, 50 and 200 ul) Zero sample holdup needle port Built-in inject signal switch TEMPERATURE CONTROL MODULEshould be able to operate from few degree above ambient to 150ºC

PDA DETECTOR Wavelength range 190-800nm Wavelength accuracy +1nm Data acquisition up to 80Hz 512 element photodiode array device Lamp optimization software Peak purity algorithm, automatic correction for noise Full spectral analysis and collection of 3D data in 3D mode HPLC Columns for routine analysis (C18-3, C8-1, NH2-1; 250x4.6 mm; 5 um) CHROMATOGRAPHY HPLC SOFTWARE a structurally validated, relational database, system security to be provided by the software and not by the operating

system. It should not have the dongle technology authentication, it should offer extensive custom calculation capabilities. Should be compliant with 21 CFR part 11 electronic signature and electronic record rules. UPS : 2kVA/5KVA with hour backup time Ultra Sonic bath- 3 lt 235x135x100mm height Timer: 0 to 60 min Temp: 0 to 60 degrees, in step of 1 deg.c, 100 watts heater Power: max. 70watts Branded PC- Intel Core i7, 4GB RAM, 500 GB hard disk, DVD writer, 18.5 screen, and Laser jet Printer-1No each

Sl No UNIVERSITY OF MYSORE DOS in Food Manasagangotri, Mysore 570 006. TENDERS FOR THE SUPPLY OF EQUIPMENTS, NETWORKING & COMPUTATIONAL FACILITIES FOR UNIVERSITY OF MYSORE (UNDER UGC SAP-I SCHEME) INVITATION FOR TENDERS ( I F T ) ( SHORT TERM ) No. MGFSN/565/ 2010-11, 06-01-2010 Ref: DC Office Bulletin No. 39/2010-11, 7.01.2011 Supply of Approxim EMD referenc Good/Equipment ate Value Amount Details (Rs) (Rs) e & date Name of the er Global Positionin g System PARA METER and time for receipt of applicati on for Blank Date and time of issue of blank and time for receipt of filled Opening date and time 1 2 3 4 5 6 7 8 9 10 11 12 1 The 2.41 5,000/- 12 18' 28 17.01.2011 20.01.2011 24.01.2011 MGFSN / Coordinator, N 566 /2010-5.00 pm 5.00 pm 5.00 pm UGC SAP (I) 11 dated 76 38' 21 DOS in Food 6.01.2011 E University of Mysore, Mysore-570 006 1) Body Composition Analyzer Frequency: 50Khz impedance, Phase, Resistance, Reactance Impedance Range: 100-1000 Ohms, Resolution: 1 Ohm Phase Range: 1.5-30.0 degree Resolution: 0.1 degree Resistance range: 100R - 1000R Reactance range: 8R - 200R Printer interface: medically isolated USB2 Relative humidity: 30% to 75% non-condensing Atmospheric Pressure: 700hPa to 1060hPa, Power: 4*1.5AA batteries Should display the following results: Impedance,Phase angle Receiving Authority 25.01.2011 The Coordinat or, UGC SAP (I) DOS in Food University of Mysore, Mysore- 570 006

Resistance,Reactance Capacitance,Dry Weight Glomerular filtration rate Total body potassium, calcium Protein & Mineral mass Fat%, Fat mass, Fat free mass, fat free mass%, Body volume, body density, Body Mass Index Resting Metabolic rate, Target Fat, target weight (min/max) Glycogen mass, Creatinine, Body Cell mass Muscle Mass Fluid status Extracellular fluid,intracellular water volume, extracellular water volume, total body water volume Intracellular water%,extracellular water %,Total body water Lt Total Body Water%,Extracellular Mass, Extracellular solids Extracellular / Intracellular Water Plasma Fluid 1. The er shall quote for one or all of the equipments mentioned in the price schedule of issued tender document. However the tenderer shall quote for the complete requirement of goods and services specified under each schedule. ers are advised to note the qualification criteria specified in Section VII of Karnataka State Transparency Act to qualify for award of the contract. 2. s must be accompanied by earnest money deposit as specified in the tender document, drawn in favour of The Finance Officer, University of Mysore, Manasagangotri, Mysore 570005. Earnest money deposit should be valid for 45 days beyond the validity of the tender. without earnest money will not be accepted. 3. s must be delivered to The Chairperson/Coordinator, Department of Studies in Food Science and University of Mysore, Manasagangotri, Mysore 570006 as mentioned. If the office happens to be closed on the last date of receipt of the tenders as specified, the tenders will be received and opened on the next working day at the same time and venue. 4. Instruction will be given to the accepted tenders that the equipment should be delivered within the prescribed date. If failed, earnest money will not be returned. 5. Rates once accepted will not be enhanced under any circumstances, and all types of existing taxes should be mentioned as per rules. The rates should hold good for at least SIX months from the closing date. 6. Conditional tender will not be accepted. 7. The Authority competent to accept the tenders shall have the right of rejecting all or any of the tenders without assigning any reasons and will not be bound to accept the lowest. The sealed tenders should reach the concerned address on or before 24.01.2011 by post or in person. DC Office tender bulletin is available on www.mysore.nic.in