Standard Operating Procedure for Zooplankton Sample Collection and Preservation

Similar documents
METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Cell Respiration Laboratory PSI Biology

The use of the analytical balance, and the buret.

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Aerobic Respiration. Evaluation copy

Experiment #2. Density and Measurements

CHM250 Calibration and Measurement Lab. Balance Calibration

Production of alcohol-based handrub

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT

CHM Introductory Laboratory Experiment (r17sd) 1/13

Pipetting Small Volumes

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

PRODUCT SHEET. Order probe only as RXPROBE02

Part A How Many Drops Are in 1 ml of Water?

How to Measure R7.1. Reference. I. Linear dimensions

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Hands-On Experiment Density and Measurement

TO RECEIVE the most benefit from a

Experimental Procedure

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

2- Phytoplankton Sampling

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS

BOYLE S / CHARLES LAW APPARATUS - 1m long

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Running the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached

Simulating Microgravity with Buoyancy A Space School Lesson Plan

Register your instrument! Eppendorf Research plus. User Adjustment

Osmosis - dependence of the osmotic pressure on the concentration (Item No.: P )

R: The Ideal Gas Constant Pre-Lab Assignment

OPERATIONS CHALLENGE LABORATORY PROCEDURE 2019

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

OPERATING INSTRUCTIONS

Using Surveying Equipment

Powers Controls RC 195 Multiple Input Receiver- Controller

Standard Operating Procedure (SOP)

Technical Procedure for General Laboratory Equipment

CHM 317H1S Winter Section P Procedures and Tables

DQM Annual Hopper QA Checks

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Standard Test Procedures Manual

SOP Standard Operating Procedure. Etching All Materials

Pipettor. User Manual

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

Standard Operating Procedure for Site Selection and Sampling for Mercury in Lakewater

SSMSP Zooplankton Sampling Protocol Julie E. Keister (Last updated by Julie E. Keister and Amanda K. Winans, 22 October 2015)

Respiration Lab Instructions

Part 1: Distillation and Analysis of an Unknown Alcohol Mixture

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

MINI HIGH SPEED TRAWL TRAWLSHARE PROTOCOLS

Measurements. Metric System

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

UsER manual for Watersens ph -REDOX

Standard Operating Procedure. Air Displacement Pipette Calibration

BoatWasher Swede, , MS Float

QUIK-jet Micro-Injection System

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

RC 195 Receiver-Controller

VERTICAL AIR COMPRESSORS

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Sampling Gears and other method. Teerapong Duangdee: Department of Marine Science, Faculty of Fisheries, Kasetsart University

VITLAB Volumetric instruments

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Before you start sampling, be sure to read

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

WELLS JOHNSON HIGH VOLUME CANISTERS

Name: Period: DUE Friday 9/ 16 Honors Chemistry Lab #1: Metric System

Laboratory practice. Preparation and use of an ice point bath as a reference temperature. Document number TE-LP-001. Version: 07

Underwater Fiber-Optic Plane Irradiance Collector

tel: fax: web:

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Customer Responsibilities

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

QAM-I-117 Volumetric Equipment Calibration Verification

Shark Biology Buoyancy by Bill Andrake

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

Guidelines on Collection of Water Samples for Phytoplankton Analysis

Density of Granular Material by Modified Sand-Cone Method for Thin Layers

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Calibration of Volumetric Glassware

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Density and Buoyancy Notes

S/Y MORSKI ZEKAN TECHNICAL INFORMATION

Biosecurity Protocol for Field Survey Work

BROCKTON AREA MULTI-SERVICES, INC. MEDICAL PROCEDURE GUIDE. Date(s) Reviewed/Revised:

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Pipette apparatus. Meet the difference. Manual. T E I

Any laboratory is equipped with specific tools, equipment,

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

Transcription:

Standard Operating Procedure for Zooplankton Sample Collection and Preservation Grace Analytical Lab 536 South Clark Street 10th Floor Chicago, IL 60605 April 13, 1994

Standard Operating Procedure for Zooplankton Sample Collection and Preservation 1.0 Scope and Application This standard operating procedure describes the sampling operations and the preservation methods for open lake zooplankton samples taken for the GLNPO Great Lakes surveys. 2.0 Summary of Method Samples are taken using a plankton tow net that is maneuvered using a winch on the starboard side of the rear work area of the R.V. Lake Guardian. The tow net, with a screened sample bucket attached to the end, is lowered to the desired depth, and raised at a constant, slow speed to collect the sample. Once the net is lifted out of the water, it is rinsed from the outside to free organisms from the side of the net, and to concentrate them into the sample bucket. The sample is transferred to a sample container, the organisms are narcotized and preserved. The samples are brought back to the CRL for analysis. 3.0 Safety and Waste Handling Formaldehyde is a known carcinogen. During the preservation of samples, the formalin should be dispensed under a hood, using gloves and safety glasses. 4.0 Equipment and Supplies Plankton tow net 64 Fm pore size (#25). Tow net sample bucket with a 61 Fm pore size metal screen. Flowmeter Weights 10-20 lbs. Safety line for sample bucket Lines for attaching weights Garden hose with attached water source Spray bottle Soda water (Club soda) Formalin (37% formaldehyde) 500 ml plastic sample bottles Repipettor with 10 ml delivery capability Graduated cylinder 50-100 ml capacity Waterproof notebook CDT 5.0 Sample Depth Sample tows are generally taken from a depth of 20 meters from the water surface (integrated sample). In waters which are shallower than 20 meters, (Western basin of L. Erie) samples (B-1 sample) are collected from 1 meter above the bottom to the surface. In cases such as this, only a B-1 sample will be taken. At Master stations, duplicate tows are taken. 1-279

SOP for Zooplankton Sample Collection and Preservation Volume 1, Chapter 4 Note: During each survey season, when calm weather permits, the flowmeter should be calibrated by repeatedly lowering it to 20 meters in very calm seas, and recording the reading. This is performed using just the flowmeter with the accompanying support ring (no net). This should be repeated 20 times. The mean value of these 20 readings divided by the depth will be used to calculate filtering efficiency for sample tows. Note: If a CDT instrument is being used on the tow line, real depth will be used for sampling instead of line length. In this case, the distance from the depth meter on the CDT to the rim of the plankton net (about 1 meter) must be measured and that distance will taken into account when reading the CDT depth. Subtract this distance from the sample depth, and have the winch operator stop the winch when the CDT indicates the corrected depth. 6.0 Sampling Procedure 6.1 Once on station, obtain the bottom depth from the rosette information provided in the wet lab. 6.2 Convert the bottom depth into meters by means of a conversion table, or 3.281 ft = 1 M. 6.3 Screw on the sample bucket so that it becomes snug. Do not over tighten. Attach the net to the winch line. Attach the safety line from the winch cable to the net ring. 6.4 Open the hatch on the flowmeter and reset all the dials to zero. 6.5 Inform the winch operator the depth of the sample to be taken. 6.6 Have the winch operator lower the net to the desired depth. The zero point for the depth on the winch is when the top of the net is at the water surface. Make sure that the tow line is as vertical as possible. If the angle exceeds 30E, repeat the tow using the CTD, and if needed, contact the bridge to have the ship re-positioned. Note: If weather conditions continually produce drifting net tows, inform the EPA Chief Scientist. 6.7 The net should be raised at a constant speed until the rim is above the water. Refer to the factory calibration for each flowmeter as each one has an optimal speed at which it functions most efficiently. Currently, the winch speed used for flowmeter #3478 is on setting "8" and corresponds to approximately 0.60 m/s. It is very important to complete each zooplankton tow using this setting. When the flowmeter or winch is eventually replaced, a new speed will have to be determined. 6.8 Do not interrupt the tow by stopping and starting the which while the net is being raised to the surface. If this occurs, repeat the tow. 6.9 Rinse the net down gently with the garden hose from the outside to wash all of the organisms off of the side of the net. Detach the sample bucket. Rinse the screening and the sides of the bucket with the spray bottle or very gently with the garden hose to collect all of the sample into the 500 ml sample container which has been appropriately labeled. Double check the labels on the bottles to make sure that the caps and bottle labels match, and that the sample is going into the appropriate 1-280

Volume 1, Chapter 4 SOP for Zooplankton Sample Collection and Preservation bottle. 1-281

SOP for Zooplankton Sample Collection and Preservation Volume 1, Chapter 4 6.10 Record the date, station, flowmeter reading, depth of tow, and angle of tow into the waterproof notebook while on deck. 6.11 In the biology lab, pour 20 ml of soda water into the sample to narcotize the organisms. Let sit for 30 minutes. Adjust the volume of the sample, using distilled water, to accommodate 20 ml of formalin solution. Once the formalin has been added, the container should be nearly full. If the container is too full to add the correct amount of formalin, allow the sample to sit for at least 1 hour after addition of the soda water. Using a pipette covered with netting, draw off enough solution in the top portion of the sample to accommodate the formalin. Store the sample in the area designated by the sample coordinator. 6.12 Transfer the recorded information taken during the sampling process from the field notebook to the Zooplankton Field Collection Sheet in the biology lab on the ship immediately after the sample is put into the cooler. The following information should be entered on each sheet: Lake, Survey, Date, Flowmeter #. The following information should be entered for each sample taken: Station, Sample type (INT, B-1), Angle, Meter start, Meter reading end, Station depth. 1-282