PRESSURE REDUCING VALVE EUROBRASSBLU CR FF

Similar documents
PRESSURE REDUCING VALVE EUROBRASS 143 FF

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Art PRESSURE REDUCER

Installation, commissioning and servicing instructions

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

PRV4 PT Pressure Reducing Valve

Flanged pressure reducer/stabilizer VRCD

Pressure reducing valves Index

TEC 1/2 3/ /4 1 1/ /2 3 4 DN A B 125,5 125,

STAINLESS STEEL OVERFLOW VALVE TYPE 417

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Slam Shut Valves SCN

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Gas Pressure Regulator HON 505

Pre-adjustable pressure reducing valves with self-contained cartridge

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

differential pressure regulating valve - threaded

Pressure reducing valves

HYDRAULIC CONTROL VALVES

Materials : Stainless steel ASTM A351 CF8M

CASH VALVE TYPE KP BACK PRESSURE VALVES

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

Pressure Reducing Valve DMV 750 set range: bar

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

WATER PRESSURE REDUCER (SBD)

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

4/2 way Pneumatic Solenoid Valve

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Dival 600. Pressure Regulators

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Solar Technology. Advantages. Everything from a single source Compact and modern design Customized models on request

Seated valves VRB 3, VRG 3

Air Operated Hydraulic Pumping Systems to 50,000 psi

CHECK VALVES APPLICATIONS

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Forged stainless steel ASTM A182 F316

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

6301 TYPE CAST IRON SAFETY VALVES

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Solenoid valves VZWF, force pilot operated

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

ACCREDITED. Function. series 5360/

Installation, commissioning and servicing instructions

Materials : Brass body dezincification-resistant up to DN1 1/4

Pressure Reducing Valve DMV 750

Self-operated Pressure Regulators for special applications

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

776 Cryogenic Safety Valve

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Pressure Relief Valve DHV 718

Ballorex Dynamic Description. Versions. Benefits. Balancing

Type 4708 Supply Pressure Regulator

VRPP 200/280 Pressure regulating valve by pneumatic control

AVPQ/AVPQ-F, PN 16. Application

Pilot HON 630a, HON 640

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

INSTALLATION, OPERATION AND MAINTENANCE HANDBOOK

Pressure Reducing Valve for steam RP 45

Pressure Reducing Valve DMV 755

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Installation, commissioning and servicing instructions

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Materials : Brass body dezincification-resistant

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Direct Operated Precision Regulator Modular Style. Standard Specifications

Pressure Reducing Valve for Steam Type 2333 A

627 Series Pressure Reducing Regulators

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Y-Pattern Strainer Valves Range

Power Valve: Precision Regulator. High precision, large capacity relief regulator

safety shut-off Valve HON 703 / HON 704

Materials : Stainless steel ASTM A351 CF8M

Gas Pressure Regulator HON 200

Materials : Forged carbon steel A105N

Dival 500 Pressure Regulators

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

VALVES HIDROMATIC VALVE.

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Transcription:

Scheda prodotto EurobrassBLU ENG Rev. 4 12/2014 PRESSURE REDUCING VALVE EUROBRASSBLU CR FF Direct acting brass pressure reducing valve; Part in contact with water made in DZR brass; Specific for alimentary use; PN 25; Adjustable outlet pressure between 0,5 and 6 bar; Brass diaphragm mechanism; Pressure compensation system; Female threading; Max temperature of use 80 C; FIELDS: The pressure reducing valves series EUROBRASSBLU 143 CR are suitable for reduction and control of pressure in plants with the following characteristics: Max inlet pressure: 25 bar Field of action (outlet pressure): 0,5-6 bar Max temperature of use: 80 C Threading of connection: ISO 228 Tested according to rules: DIN EN 1567 Suitable fluids: Water, compressed air Reduction rate : 10 : 1 MATERIALS: Metal of the body: Brass alloy CW602N UNI EN 12165 - CB753S EN 1984 Metal of the inner parts: Brass alloy CW602N UNI EN 12165 Seat: Stainless steel AISI 303 Bar: Stainless steel AISI 303 O-rings: NBR 70sh Flat gaskets: Fasit Italy Lubricant: Alimentary grease Plastic parts: Ultramid A3K (BASF)

MAIN DIMENSIONS OF THE PRESSURE REDUCING VALVES EUROBRASSBLU 143 CR ITEM DN Weight gr H L 143.12.BG ½" 930 122 88 143.34.BG ¾" 900 122 88 143.33.BG 1" 1.340 160 89 143.114.BG 1" ¼ 2.290 220 125 143.112.BG 1" ½ 2.400 220 130 143.58.BG 2" 3.950 250 138 143.58.BG 2" 3.950 250 138 FLOW RATE vs PRESSURE DROP CHART:

FLOW vs FLOW CHART: CAVITATION CHART:

BEST HYDRAULIC DISCHARGE OF PRESSURE REDUCERS EUROBRASSBLU 143 CR In order to choose the best pressure reducers for any plant, we suggest to follow the indications mentioned in the underexposed table with the best running pressure of the valves EurobrassBLU 143 CR; the values are exposed both in litres/minute and cbm/hour, and indicate the field of use where you can obtain the best functioning, silence and smaller loss of charge of the valves. MODEL SIZE AVERAGE HYDRAULIC DISCHARGE L/min AVERAGE HYDRAULIC DISCHARGE Cbm/hour EUROBRASS 143 ½" 20-50 1,2-3 EUROBRASS 143 ¾" 30-65 1,8-3,9 EUROBRASS 143 1" 75-95 4,5-6 EUROBRASS 143 1" ¼ 95-130 6-8 EUROBRASS 143 1" ½ 110-140 7-8,5 EUROBRASS 143 2" 120-160 7,5-10 INSTALLATION OF THE PRESSURE REDUCING VALVE The pressure reducers EUROBRASSBLU 143 don t get the effects for their functioning of the gravity force; therefore they can be installed in the plant in any position: Pressure reducing valves can be damaged by dirty water; therefore we advise to install a self-cleaning filter upstream before the pressure reducer, in order to protect the valve and any other mechanism (thermostatic mixers, taps, etc.). When there is a device which produce or store hot water or pipes are exposed to sudden changes in temperature, an increase of outlet pressure may occur; this event is due to the raise in pressure that follows the temperature rising: an expansion vessel between downstream the pressure reducing valve will avoid this problem. We recommend moreover to install a Stopshock valve to prevent water hammer which would damage the inner parts of the pressure reducer and other devices in the waterworks.

Recommended installation of the pressure reducing valve: 1 BALL VALVE 3 EUROBRASS PRESSURE REDUCER 5 EXPANSION VESSEL 2 NEPTUN SELF-CLEANING FILTER 4 STOPSHOCK VALVE 6 BALL VALVE HOW TO ADJUST THE PRESSURE All Malgorani pressure reducers are tested before being packaged; during the proof they are pre-set at the outlet pressure of 3 bars; the model 143. Installation or any change of outlet pressure must be performed by qualified personnel; In order to modify the outlet pressure, once removed the seal, you should only loosen the fixing ring and turn the spring holder as indicated in the pictures sequence. By turning clockwise the pressure increases, while counter-clockwise the pressure decreases. A right setting should be made while the plant outlet is closed.