INJECTION ODORIZING SYSTEMS : DOSAODOR TYPE

Similar documents
Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

RESIDENTIAL REGULATORS

64 Series Pressure Reducing Regulators

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TITAN FLOW CONTROL, INC.

MEGR-1912 Instruction Manual

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Float Operated Level Controllers

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Types 749B and R130 Changeover Manifolds

1805 Series Relief Valves

Types S100K and S102K Pressure Regulators

Temperature Controllers

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

BUTTERFLY VALVES Series 800

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

MEGR-1627 Instruction Manual

WHEATLEY Series 822/820 Swing Check Valve

TITAN FLOW CONTROL, INC.

TECHNICAL DATA. Q = C v P S

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Pilot-Operated Relief Valves

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Telefon (+45) Telefax (+45)

MUELLER. Xp, & Lineseal 350 Butterfly Valves

TECHNICAL DATA. Q= Cv S

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

TECHNICAL DATA. Q = C v P S

Type FEQ Slam-Shut Valve

Eaton Filtration, LLC

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TECHNICAL DATA. Q = C v P S

PRESSURE REGULATORS. Type B/240. Process Management TM

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

PRESSURE REGULATORS. Type A/140. Process Management TM

WHEATLEY Series 500 Swing Check Valve

TECHNICAL DATA. Q = C v P S

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

GREIG FILTERS, INC. OPERATION MANUAL

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

1305 Series Pressure Reducing Regulators

TECHNICAL DATA. Q = C v P S

1301 Series High-Pressure Regulators

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

553 Series.

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

DelVal Flow Controls Private limited

BS Series Basket Strainer

TECHNICAL DATA. Q = C v P S

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

SLAM-SHUT VALVES. Type BM5. Process Management TM

PRO-50 Instrument Supply Regulator

for the of and the EM55-1

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION and MAINTENANCE MANUAL

Operating Manual FSV, FSÖV, SSVF

CAST IRON SAFETY VALVE TYPE 6301

FV Flash Vessel Installation and Maintenance Instructions

Type OS/66 Slam-Shut Controller

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Wet pipe low flow foam/water system

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Manual Actuated Boiler Blowdown Valves

Model MTB-ASME Horizontal Bladder Tanks

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

HYDROSTATIC LEAK TEST PROCEDURE

Fisher DVI Desuperheater Venturi Inline

OPERATION AND MAINTENANCE MANUAL

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Eaton Filtration, LLC

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Type PS/79-1 and PS/79-2

Standard Pneumatic Test Procedure Requirements for Piping Systems

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

TECHNICAL DATA Q= C. Table 1 - Specifications

Transcription:

0198GB Rev. 02 - Page 1/6 - English INJECTION ODORIZING SYSTEMS : DOSAODOR TYPE The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. O.M.T. Officina Meccanica Tartarini s.r.l. Via P. Fabbri, 1 I - 40013 Castel Maggiore (Bologna) Italy Tel. : +39 0514190611 Fax: +39-0514190715 E-mail: tartarini@tartarini.it Web: www.tartarini.it

0198GB Rev. 02 - Page 2/6 - English INDEX 1) P.E.D. CATEGORIES AND SPECIFICATIONS 2) HAZARDS 3) HANDLING 4) PRESERVATION AND STORAGE 5) INSTALLATION 6) START UP AND SHUTDOWN 7) MAINTENANCE 8) DRAWINGS

0198GB Rev. 02 - Page 3/6 - English The DOSAODOR cylindrical tank is just a part of the electro-pneumatic panel of the DOSAODOR odorizing systems series produced by OMT Tartarini SpA : installation, operation, maintenance, start-up and shut-down procedures have to be in accordance with station s safety procedures and the Instruction Manual of the DOSAODOR system. This Safe Use Guide provides instructions and safety information on DOSAODOR cylindrical tank so as to avoid any foreseeable risk during the use. For further information refer to DOSAODOR Bulletin, nn 176 & 177, and their Instruction Manuals. To receive a copy of the Bulletin, please contact your local O.M.T. Tartarini Sales Office or O.M.T Tartarini Sales Representative. 1. P.E.D. CATEGORIES AND SPECIFICATIONS 1.1 P.E.D. Categories and Fluid Group 1.2 Specifications Volume : 1,3 and 2 liters Pipes connection style : ¼ NPT Type Category Fluid Group DOSAODOR Cylindrical tank II 1! WARNING! Type Maximum Allowable Pressure (PS) Hydrostatic Test Pressure (PT) bar bar DOSAODOR Cylindrical tank 100 150 Minimum/Maximum Allowable Temperature (TS) -10 +60 C N.B. : The pressure/temperature limits detailed in this Safe Use Guide and any applicable standard or code limitation should not be exceeded. 2. HAZARDS 2.1 Only qualified personnel shall install an odorizing system. Odorizing systems should be installed, operated and maintained in accordance with international and national applicable codes and regulations. Following notes and instruction point out, in particular, the pressure risk. Installation, operation and maintenance procedures performed by unqualified personnel may result in unsafe operation. This condition may result in equipment damage or personal injury. If a leak develops in the system, the escaping gas may accumulate and become a fire or explosion hazard. Immediately call qualified service personnel in case of trouble. 2.2 Hazards arising from mis-use and mis-operating are: Personal injury, equipment damage, or leakage due to escaping gas or bursting of pressure-containing parts may result if the equipment is installed where its capabilities (PS and TS) can be exceeded or where conditions exceed any ratings of the adjacent piping or piping connections. Physical damage could result in breakage, causing personal injury and property damage due to escaping gas. 2.3 Installing the equipment where its capabilities, or those of any downstream equipment, can be exceeded may cause personal injury or property damage due to bursting of pressure-containing parts or explosion of accumulated gas. To avoid above hazards, install the equipment where: - service conditions are within unit capabilities. - service conditions are within applicable local, federal or national codes or regulations. - the unit is protected from exposure to physical damage and/or corrosive substances. - suitable pressure-limiting or pressure-relieving devices have been installed in those instances where supply pressure is capable of exceeding the maximum allowable downstream equipment pressure.

0198GB Rev. 02 - Page 4/6 - English 3. HANDLING 3.1 The equipment supplied with present package is shipped already installed in the electro-pneumatic panel of the DOSAODOR system. Above panel has been designed to hold tank weight: established transport and handling procedures shall be followed to avoid any damage on the pressure containing parts by shocks or anomalous stresses. 3.2 The equipment is self stiffened and standard lifting devices may be used for handling. 3.3 Special care must be taken over avoiding any damage to pressure accessories installed together with the DOSAODOR cylindrical tank. 4. PRESERVATION AND STORAGE 4.1 DOSAODOR equipment is delivered all surfaces completely protected (paint or inox steel material), hence the equipment doesn t need specific precautions for storage, providing to follow the recommendations listed below. 4.2 Upon arrival at site, the unit shall be completely inspected for eventual damage caused by transportation. Repair actions shall be carried out as soon as possible to avoid paint scaling and rust propagation, if any. 4.3 Inspection shall be done also on possible assembled pressure accessories (valves, level indicator, ) 5. INSTALLATION! WARNING! National safety standards and established rules shall be applied in odorizing system installation and operation, concerning, in particular, electrical works, fire and thunderbolt protection, safety procedures on odorisant handling. All means for venting have to be provided in the assemblies where the pressure equipment is installed. Before installation, check shall be done if service conditions are consistent with use limitations. Where this product is used : - provide the cathodic protection and electrical isolation to avoid any corrosion and - the gas shall be cleaned by proper filters/separators/scrubbers to avoid any technical & reasonable hazard of erosion or abrasion for pressure containing parts DOSAODOR cylindrical tank shall be installed in non-seismic area and hasn t to undergo fire and thunderbolt action. 5.1 Levelling The vessel should be installed to the correct level and vertical line if any within the limits agreed by data sheet or specifications. 5.2 Access The vessel should be installed with sufficient clearance from associated structures and equipment to provide safe, efficient working by operators and to provide ready access for cleaning, inspection and maintenance. Support should be so arranged to provide adequate facility for the inspection of every part of the vessel. 5.3 Ventilation Equipment should have adequate ventilation around them, particularly where vessels are located indoors. The ventilation requirements should take into account the type of medium which may escape from the equipment. Special requirements for lethal material should be agreed with the Authority involved. 5.4 Lighting Where necessary, the illumination level of lighting at the equipment should be sufficient to allow free movement of operating personnel in safety while in operation under normal conditions. Permanent lighting should provide an illumination level which ensures that portable lights will not be required in the normal operation. For further information on installation procedures refer to DOSAODOR Bulletin and their Instruction Manuals.

0198GB Rev. 02 - Page 5/6 - English 6. START-UP AND SHUTDOWN 6.1 Upon arrival at site the equipment must be inspected for eventual damages occurred during transportation. At least, the following points have to be inspected: a) integrity of nozzles closure and equipment sealing b) status of painted surfaces. If paint is damage any touch-up shall be carried out in accordance with the project coating specification c) visual check of critical areas such as pipe plugs, level gauge connection,... 6.2 Any damage shall be reported to the project team and to the vendor in order to agree and co-ordinate any repair work. 6.3 The equipment is been subject to hydrostatic test at the factory according to applicable codes requirements and thoroughly inspected for leakage during the above test. However, handling during transportation or moving into place may have loose gasketed seals: based upon the above, it is recommended to recheck all bolted connections prior to start up. 6.4 Equipment operating at high pressure should be warmed up slowly and uniformly before applying full pressure. Tank is particular sensitive to pressure increase very rapidly. Pressure should be increase in stages of approximately 10% of operating pressure up to the operating value. In case of leakage or other inconvenience, the procedure should be immediately stopped and the problem investigated and removed before a new start-up. 6.5 Gasketed connections Before start-up and after initial start-up, at normal operating pressure and temperature, it is recommended to inspect all gasketed joints for tightness. 6.6 Shutting down When possible, reduce slowly the pressure in order to avoid damage. In no case open the equipment before the pressure is completely released. For further information on start-up and shutdown procedures refer to DOSAODOR Instruction Manuals. 7. MAINTENANCE 7.1 At regular intervals and as frequently as experience indicates, an examination should be made of the tank condition. In case of need, specific procedures are prepared by Manufacturer according national and applicable codes and regulations. The frequency of inspection/checks and replacements depends upon the severity of service conditions and upon applicable codes and national standards/rules. 7.2 If any liquid leakage or gas escaping occurs, safety station procedures shall be applied to shut-down odorizing system. 7.3 No special spare part is foreseen for odorizing tanks. For further information on maintenance and cleaning procedures refer to DOSAODOR Instruction Manuals.

0198GB Rev. 02 - Page 6/6 - English 8. DRAWING 1 2 3 N Name 1 Top Threaded Plug 2 Cylinder 3 Bottom Threaded Plug