Wind effects on tall building frames-influence of dynamic parameters

Similar documents
Critical Gust Pressures on Tall Building Frames-Review of Codal Provisions

Effect of Wind Pressure on R.C Tall Buildings using Gust Factor Method

Along and Across Wind Loads Acting on Tall Buildings

Numerical Analysis of Wind loads on Tapered Shape Tall Buildings

Quantification of the Effects of Turbulence in Wind on the Flutter Stability of Suspension Bridges

Wind Pressure Distribution on Rectangular Plan Buildings with Multiple Domes

SPECTRAL CHARACTERISTICS OF FLUCTUATING WIND LOADS ON A SEPARATE TWIN-BOX DECK WITH CENTRAL SLOT

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Wind Loading Code for Building Design in Thailand

GEA FOR ADVANCED STRUCTURAL DYNAMIC ANALYSIS

CIVL473 Fundamentals of Steel Design

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Comparison on Wind Load Prediction of Transmission Line between Chinese New Code and Other Standards

Effect of Depth of Periphery Beams on Behavior of Grid Beams on Grid Floor

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY

EXPERIMENTAL STUDY OF WIND PRESSURES ON IRREGULAR- PLAN SHAPE BUILDINGS

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

International Journal of Advance Engineering and Research Development

UNIVERSITY OF HONG KONG LIBRARY. Hong Kong Collection

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 3, 2012

External Pressure Coefficients on Saw-tooth and Mono-sloped Roofs

Analysis and Design of Elevated Intze Watertank and its Comparative Study in Different Wind Zones - using SAP2000

Journal of Engineering Science and Technology Review 9 (5) (2016) Research Article. CFD Simulations of Flow Around Octagonal Shaped Structures

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

EXPERIMENTAL INVESTIGATIONS OF BARGE FLOATER WITH MOONPOOL FOR 5 MW WIND TURBINE

EXPERIMENTAL INVESTIGATION OF WAKE SURVEY OVER A CYLINDER WITH DIFFERENT SURFACE PROFILES

PRESSURE FLUCTUATIONS ACTING ON A TAPERED TALL BUILDING

Pushover Analysis of Water Tank Staging

Wind Turbine on Telecom Tower

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

Adaptive Pushover Analysis of Irregular RC Moment Resisting Frames

Non-Linear Seismic Analysis of Multi-Storey Building

International Journal of Advanced Engineering Technology E-ISSN

Catenary Mooring Chain Eigen Modes and the Effects on Fatigue Life

Basis of Structural Design

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION

Wind tunnel test and numerical simulation of wind pressure on a high-rise building

Yasuyuki Hirose 1. Abstract

Wave Motion. interference destructive interferecne constructive interference in phase. out of phase standing wave antinodes resonant frequencies

Vibration response of long cable-stayed timber footbridge case study

Geometry Modification For Minimizing The Aeroelastics Effect

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

THE TACOMA NARROWS BRIDGE FAILURE Revision A

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Aerofoil Profile Analysis and Design Optimisation

Determination of the Characteristics of High Winds in Istanbul

Compensator Design for Speed Control of DC Motor by Root Locus Approach using MATLAB

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

Effects of directionality on wind load and response predictions

Pressure coefficient on flat roofs of rectangular buildings

Using Experimental Procedure to Improve the Efficiency of the Two Stand Reversing Cold Mill

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading

Slope Bottom Tuned Liquid Dampers for Suppressing Horizontal Motion of Structures

Aerodynamic Analysis of a Symmetric Aerofoil

ITTC Recommended Procedures Testing and Extrapolation Methods Loads and Responses, Seakeeping Experiments on Rarely Occurring Events

EXPERIMENTAL ANALYSIS OF MECHANICAL PROPERTIES OF SELECTED TAKRAW BALLS IN MALAYSIA

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

Presented to the International Technical Rescue Symposium, November Abstract

The Seventh International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7) Shanghai, China; September 2-6, 2012 Wind tunnel measurements

NUMERICAL SIMULATION OF STATIC INTERFERENCE EFFECTS FOR SINGLE BUILDINGS GROUP

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

AIRMOUNT VIBRATION ISOLATION

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Computational Analysis of Cavity Effect over Aircraft Wing

Experimental Investigation Of Flow Past A Rough Surfaced Cylinder

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Computationally Efficient Determination of Long Term Extreme Out-of-Plane Loads for Offshore Turbines

COMPUTATIONAL FLUID DYNAMICS (CFD) INVESTIGATION TO ASSESS WIND EFFECTS ON A TALL STRUCTURES (WIND FORCE PARAMETERS)

Evaluating the Design Safety of Highway Structural Supports

Learn more at

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

Full scale measurements and simulations of the wind speed in the close proximity of the building skin

Reduction of Skin Friction Drag in Wings by Employing Riblets

Copyright by Turbomachinery Laboratory, Texas A&M University

SUBPART C - STRUCTURE

STABILITY OF MULTIHULLS Author: Jean Sans

FUTURE Flutter-Free Turbomachinery Blades

Waves. harmonic wave wave equation one dimensional wave equation principle of wave fronts plane waves law of reflection

Aerodynamic Terms. Angle of attack is the angle between the relative wind and the wing chord line. [Figure 2-2] Leading edge. Upper camber.

Wind-Induced Oscillations Parametric Wind Tunnel Test

Application of pushover analysis in estimating seismic demands for large-span spatial structure

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

A Study on Roll Damping of Bilge Keels for New Non-Ballast Ship with Rounder Cross Section

DYNAMIC POSITIONING CONFERENCE October 7-8, New Applications. Dynamic Positioning for Heavy Lift Applications

Turbulence and How to Avoid It

CFD ANALYSIS OF AIRFOIL SECTIONS

PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1

Journal of Engineering Science and Technology Review 6 (3) (2013) Research Article

TOWARD MORE ACCURATE PREDICTION OF DAMAGE DUE TO STRONG WINDS

Wind Action Effects on Mixed Reinforced Concrete Structures in Non Seismic Zones

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Steady State Comparisons HAWC2 v12.5 vs HAWCStab2 v2.14: Integrated and distributed aerodynamic performance

Volume 2, Issue 5, May- 2015, Impact Factor: Structural Analysis of Formula One Racing Car

RESEARCH ON THE WIND LOAD PARAMETERS AND THE WIND FENCES BEHAVIOR FOR WIND FENCES OF RAILWAY BRIDGE

Vibrations of table tennis racket composite wood blades: modeling and experiments

CHAPTER 113 Impact Loading and Dynamic Response of Caisson Breakwaters

Calibration and Validation of the Shell Fatigue Model Using AC10 and AC14 Dense Graded Hot Mix Asphalt Fatigue Laboratory Data

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

Transcription:

Indian Journal of Science and Technology Vol. 3 No. 5 (May 21) ISSN: 974-6846 583 Wind effects on tall building frames-influence of dynamic parameters B. Dean Kumar 1 and B.L.P. Swami 2 1 Department of Civil Engineering, JNTU College of Engineering, Hyderabad-585, India 2 Department of Civil Engineering, Vasavi College of Engineering, Ibrahim Bagh-531, India deankumar@yahoo.com Abstract In the recent past many tall buildings and high rise towers are being built in India. The impact of wind loads are to be considered for the design of these towers on par with steel towers like transmission towers, microwave towers, cooling towers and very tall multistoried building towers. Several failures of structures have occurred in India due to wind. The IS 875 Part-3 deals with wind loads on different types of structures. In the present work, the Gust Effectiveness Factor Method is used,which is more realistic particularly for computing the wind loads on flexible tall slender structures and tall building towers. In this paper frames of different heights are anlaysed and studied Keywords: Wind loads; dynamics; wind velocity; s; mean hourly wind. Introduction The development of modern materials and construction techniques has resulted in the emergence of a new generation of structures that are often, to a degree unknown in the past, remarkably flexible, low in damping, and light in weight. Such structures generally exhibit an increased susceptibility to the action of wind. Accordingly it has become necessary to develop tools enabling the designer to estimate wind effects with a higher degree of confidence than was previously required. Wind engineering is the discipline that has developed, primarily during the last few decades from effects aimed at developing such tools. It is the task of the engineer to ensure that the performance of structures subjected to the action of wind will be adequate during their anticipated life from the standpoint of both structural safety and serviceability. Under the action of wind flow, structures experience aerodynamic forces that include the drag (along-wind) force acting in the direction of the mean wind, and the lift (across-wind) force acting perpendicular to the direction. The structural response induced by the wind drag is commonly referred to as the along wind response. Xinzhong (28) studied the frequency domain analysis of along wind response to transient nonstationery winds. It has been recognized that in the case of modern tall structure which are more flexible lower in damping and lighter in weight than their predecessors, the natural frequencies of vibration may be in the same range as the average frequencies of occurrence of powerful s and that, therefore, large resonant motions induced by wind may occur, which must be taken into account in design. Davenport (1967) presented the procedure and formulation of dynamic factor. Structures that have performed inadequately or that have failed owing to lift and/or aerodynamic moment effects include slender towers and stacks, tall buildings, and suspended span bridges. Individual structural members, cables and power lines, may also be susceptible to aerodynamic, effects involving across wind and/or torsional response. Wind effects on structures In the case of structures the flow interacts only with the external shape of the structure. When the structure is very stiff, deflections under the wind loads will not be significant, and the structure is said to be Static. As the lowest mode frequencies are high, there is little energy in the spectrum of atmospheric turbulence available to excite resonance. The only design loading parameter of importance is the maximum load likely to be experienced in its lifetime. The parameters most relevant to the assessment of design loading are Influence functions, size parameters of the structure, load duration and assessment of load for design. Wind effects on dynamic structures In the case of dynamic structures, there is an additional interaction with the motion of the structure. When the structure is sufficiently flexible, the response to wind loads is significant to the design of the structure. The conventional approach to the analysis of dynamic response of lightly damped structures is by resolving the response into the natural modes of vibration, characterizing each normal mode as a set of model parameters: 1) Model shape, 2) Model mass, 3) Model stiffness and 4) Model damping. Using these parameters a frequency response function can be defined that describes the dynamic characteristics of the structures. Wind loads on tall buildings The wind load is the most important factor that determines the design of all buildings over 1 storeys. Buildings taller than 1 storeys would generally require additional steel for lateral system. Under the action of a natural wind, s and other aerodynamic forces will continuously affect a tall building. The structure will deflect about a mean position and will oscillate

Indian Journal of Science and Technology Vol. 3 No. 5 (May 21) ISSN: 974-6846 584 continuously. Swami (1987) studied that if the wind energy that is absorbed by the structure is larger than the energy dissipated by structural damping, then the amplitude of oscillation will continue to increase and will finally lead to destruction. The structure will become aerodynamically unstable. The structural forms used today have greater flexibility combined with less mass and damping than those used for traditional structures of the past. These factors have increased the importance of wind in design consideration. For estimations of the overall stability of a structure and of the local distribution on the building, knowledge of the maximum steady or time averaged wind loads is usually sufficient. Hence for this purpose the I.S code ascertains the importance of wind induced oscillations or excitations. Nature of wind in atmosphere Wind means the motion of air in the atmosphere and is caused by differences in temperature over earth s surface. The wind speed increases from zero at ground level to a maximum at a height called gradient height. The magnitude of fluctuating component of the wind speed, which is called the, depends, on the average time. In general, smaller the averaging interval, greater is the magnitude of the speed. Basic wind speed Davenport (1982) gave the procedure for developing design wind speeds. The wind speed recorded at DPT stations is analyzed to obtain the extreme wind speeds. The DPT has averaging time of about 3 seconds, analysis gives velocities averaged over 3 seconds and they correspond to 1metre height for the open terrain. Design wind speeds for structures Design wind speed (Vz) at any height can be calculated as follows: V Z = V b K 1 K 2 K 3 (1) Where, V b = Basic wind speed in m/s V z = Design wind speed at any height z in m/sec K 1 = Probability factor; K 2 = Terrain, height and structure size factor K 3 = Topography factor Design wind : The design wind at any height above mean ground level shall be obtained by the following relationship between wind and wind velocity. P z = design at height z due to hourly mean wind. Eq. (2) Where P Z = Design wind in N/m² at height z, Vz = Design wind velocity in m/s @ height z. Thus, wind loads are computed based on the considerations of the design wind speed and the height of the structure. The other properties of the structure like size, stiffness, damping, etc., are not considered. Gust effectiveness factor method (AS PER IS-875 PART- III-1987) As discussed already, Gust Effectiveness Factor Method is a more realistic and rational approach to deal with wind loads on tall building towers. Hourly mean wind speed with height: The variation of hourly mean wind speed with height shall be calculated follows. = V b *K 1 *K 2 *K 3 (3) Where = hourly mean wind speed in m/s at height z ; V b = basic wind speed in m/s; K 1 = Probability factor; K 2 = Terrain and height factor; K 3 = Topography factor. Along wind load Along wind load on structure on strip area (Ac) at any height (z) is given by: F z = C f *A e *P z *G (4) Where, F z = along wind load on the structure at any height z corresponding to strip area Ac, C f = force coefficient for the building, A e = effective frontal area considered for the structure at height z, P z = design at height z due to hourly mean wind obtained as (N/m 2 ) G= factor (peak load/mean load) and is given by: G = 1 + g f r (5) g r = peak factor defined as the ratio of the expected peak value to the root mean value of a fluctuating load, and r = roughness factor which is dependent on the size of the structure in relation to the ground roughness. The value of gf r is obtained from (IS 875 PART-3) B = background factor indicating a measure of slowly varying component of fluctuating wind load and is obtained from (IS 875 PART-3), S= Size reduction factor is obtained from (IS 875 PART- 3), E=measure of available energy in the wind stream at the natural frequency of the structure is obtained from (IS 875 PART-3), = Damping coefficient (as fraction of critical damping) of the structure. /4 and is to be accounted only for buildings less than 75m height in terrain category 4

Indian Journal of Science and Technology Vol. 3 No. 5 (May 21) ISSN: 974-6846 and for buildings less than 25m height in terrain category 3, and is to be taken as zero in all other cases. Cy b Cz h and F o = C z f o h/ V z Where Cy=lateral correlation constant which may be taken as 1 in the absence of more precise load data, Cz= longitudinal correlation constant which may be taken as 12 in the absence of more precise load data, b=breadth of a structure normal to the wind stream. h=height of a structure Vh=Vz=hourly mean wind speed at height z, Fo=natural frequency of the structure, and L (h) =a measure of turbulence length scale. Details of the present study Parameters considered for study The present study includes the study of nature and variation of s. For this study, multistory frames ranging from 2 to 1 storeys are considered. From this the variation of s with height will be clearly known. By considering single bay and two bay frames in all the cases, the influence of the size of the building on s will be known. The IS code (875 part-iii-1987) has suggested an empirical rule to compute the fundamental frequency for multi-storeyed frames. This is grossly approximate and doesn t take into consideration the size of the building and the relevant dynamic properties of the structure. In the present study, dynamic analysis of the frame is conducted, and the actual fundamental frequency is computed in different cases. Gust s are computed based on actual frequencies for comparison. Details of frames In the present analysis, multistory frames of 2, 4, 6 and 1 storeys with one bay and two bays are considered. The typical size of column is.3 m X.49 m. The size of beam is.3 m X.4 m. The height of each storey is 3.5 m. Gust s A computer programme is written for the Gust Effectiveness Factor Method. Gust factors and s are computed using the programme. The computed values of factors for different frames considered are obtained for single and two bays. The s are also computed for all the frames under consideration with one and two bays. Axial forces in columns The computed values of axial forces in columns based on Gust effectiveness factor method and method are obtained for all the frames with one and two bays. Results and discussions Criticality of wind loads for the design of multi-storeyed frames In structures of normal height, even upto 2 storeys height, dead and live loads are predominant. The wind 585 loading effects are covered by the increase of permissible stresses as recommended by the I.S. code (IS 875 Part 3). Hence, for the design of buildings of low to medium height the wind effects are usually ignored. As the height of the building frames increase, the wind effects become gradually considerable. In the case of very tall slender frames they even become predominant compared to dead and live load effects. Very tall slender building frames are flexible in nature and as a result they interact with the wind dynamically and the safety and the stability of structure may become critical. Hence, for design of very tall frames, a thorough study of wind effects and investigation of criticality are very much necessary. This is particularly so in regions where wind is more critical than earthquakes. Variation of s with height Swami (29) showed that in general, s increase with height in the case of multistory frames of different storeys. The variation of s with height for typical frames is plotted and shown in Fig. 1 to 4. In the case of a 2 storey building the s increase from 1.13 kn/m² to 2.52 kn/m² in the case of single bay and from 1.11 kn/m² to 2.48 kn/m² in the case of two bay. In general, the increase in s is about 18% over a height between 3.5 m to 7 m in the case of a 2- storey frame. In the case of 6 storey frame, the increase in s is more than 21% over a height up to 18 m. Similarly in the case of 1 storey frame the increase over a height of 28 m is more than 23% Hence, it is clear that the s increase with height of the frames, become considerable and may even become critical in the case of very tall buildings. Static s versus s By comparing the values of wind s computed by method and the Gust Effectiveness Factor Method, it can be seen that the s are more than the s. For example, in the case of 2-storeyed single bay, the s are more than the s by 15 to 38% from 3.5 m to 7 m. For a 2-storeyed two bay they are 13 to 37%. Similarly, in the case of 6-storeyed single bay the difference is from 33 to 58% and 6-storeyed two bay the difference is from 31 to 57% from 3.5 m to 21 m. The Gust Effectiveness Factor Method takes into consideration the aspect ratio and the size effect which influences the force co-efficient in the case of multistoried buildings. The method does not consider the size of the building and the dynamic properties of the building except the height. Hence, the s are safer compared to s, particularly in the case of tall, slender multistoreyed frames. Variation of factor with height It can be seen that the overall factor decreases with the height of building. For example, the factor is 3.9 for the 2-storey building with single bay and the

Indian Journal of Science and Technology Vol. 3 No. 5 (May 21) ISSN: 974-6846 Fig. 1. Variation of the & Fig. 2. Variation of the & s with height of a s with height of a 2-storeyed building (1-bay) 8 2-storeyed building (2-bay) 8 7 7 6 6 5 5 4 HEIGHT (M 4 3 2 1 25 2 15 1 5 2 4 (KN/sqmm ) Fig. 4. Variation of the & s with height of a 6-storeyed building (2-bay) 1 2 3 4 5 (KN/sqmm) Fig. 5 Variation of the axial loads with height of 2-storeyed (1-bay) 8 7 6 5 4 3 2 1 w indw ard leew ard 5 1 15 2 25 AXIAL LOADS (KN) AXIAL LOAD (KN) 25 2 15 1 5 3 2 1 2 4 (KN/sqm m ) Fig. 3. Variation of the & s with height of a 6-storeyed building (1-bay) 1 2 3 4 5 (KN/sqmm) Fig. 6. Variation of the axial loads with height of 1-Storeyed (1-bay) 4 35 3 25 2 15 1 5-4 -2 2 4 6 w indw ard leew ard 586

Indian Journal of Science and Technology Vol. 3 No. 5 (May 21) ISSN: 974-6846 value becomes 2.82 for the 1-storey building. This clearly indicates that as the building height increases its flexibility also increases. The fundamental frequencies decrease and overall factor decreases. When wind s are computed, as per I.S 875 part-iii, it is quite clear that wind s increase with height of the building. This increase occurs in the case of factor method also. The factor decreases with height. Though s increase with height of the building the variation becomes smaller. Hence, s are safer for design particularly for structures of greater height and at the same time they are more rational and realistic. Variation of column axial forces The Column axial forces are less on the windward side than on leeward side. The variation of axial force with height for typical frame is plotted and shown in Fig. 5 and 6. For example, for a 2-storeyed single bay building, the axial force due to 1.2(DL+LL+WL) at a height of 17.5m is 647 kn on windward side and 1586 kn on leeward side. Also for frames beyond 2-storeyed the windward columns are subjected to tensile axial force. Hence, in the design of columns of tall multistoried frames, the axial compressive forces in the leeward columns are critical and windward columns are to be checked for tensile axial forces. Variation of column bending moments: The column bending moments are less on the windward side than on the leeward side. For a typical 2- storeyed single bay frame, the values of moments at a height of 17.5 m above the base are 93 knm for leeward column and 46 knm for the windward column. In the case of typical 1-stroreyed single bay frame, moments are 499 knm and 452 knm respectively at a height 14 m above the base. Validity of factor method: From the above discussion it is clear that the factor method is very much valid for computing design wind s on tall structures. Very tall structures are slender and flexible. The fundamental frequency is lower and the structure dynamically interacts with wind. Wind has two components like mean and fluctuating. Hence the dynamic interaction between tall flexible structures and wind is to be investigated. The possibility of resonance and its influence on the structure are to be clearly known. Hence, the factor method gives not only safer design s but also it is more rational compared to the method. Thus, factor method gives more confidence to the designer because it takes into account all aspects. Conclusions Based on the computed results and the discussion made, the following conclusions are drawn: The s computed by effectiveness factor method increase with the height of the building and they are more critical than 587 s and as such effectiveness factor method gives critical wind s to be considered in the design of tall multistoreyed frames. The difference in the values of s computed for single and two bays is small, however for exact determination of internal stresses, the size effect given by number of bays is to be considered. The size reduction factor increases with the height of the building frame. In arriving at the effectiveness factor, it is very much necessary to investigate the resonance effects on the basis of actual computed fundamental frequency. As the height of building frame increases, the energy content in the fluctuating component of wind also increases. The peak factors increase with the height of the building because of the decrease in wind turbulence. The overall factor decreases from one. building frame to other as the height is increased. In the design of columns of tall multistoreyed frames the axial compressive forces in the leeward columns are critical and it is quite predominant when wind is considered. The windward columns of tall multistoreyed frames are to be checked in the design for tensile axial forces and they are to be compensated by means of heavy foundations and other dead loads. The Column moments due to wind are becoming critical for the design. On the whole, the wind s computed by the effectiveness factor method are not only safer for design but also they are more rational and realistic. This is an important and valid point to be considered for the design of very tall buildings and structures. References 1. Davenport AG (1967) Gust loading factors. Struct. Div. ASCE. Proc. Paper 5255, 93, 11-34. 2. Davenport AG(1982) The interaction of wind and structure. Engg. Metoro. 269, 527-572. 3. IS-875 (1987) Code of practice for design loads for building and structures. Part-3 wind loads. Published by Bureau of Indian Standards. 4. Swami BLP (1987) Study of wind speeds in India and their effects on typical structures. Ph.D. Thesis submitted to the I.I.T., Delhi. 5. Swami BLP, Dean Kumar B and Narasimha Rao J (29) Critical effects on tall building framesinfluence of various dynamic parameters. ICAMB. 3, 244-252. 6. Xinzhong Chen (28) Analysis of along-wind tall building response to transient nonstationary winds. ASCE. 134 (5), 782-791.