Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Similar documents
Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Chapter 14 Water Shuttle Operations

Apparatus Operator Refresher Training Program

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Driver Operator Pumps: Basic Pump Operations

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

Essentials of Fire Fighting

TurboDraft Fire Eductor

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

TurboDraft. Fire Eductor Operating Instructions.

Topic: Equipment Scramble Reference #: DG14-03 Date: March 10, 2014 Level of Instruction: In service personnel Time Required: 3 Hours

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed:

Varying pump capacity affects the required hoseline diameter

Water Supply for Suburban and Rural Firefighting

Essentials of Fire Fighting 6 th Edition Firefighter I

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Fire Apparatus Operator: ARFF

Galva Fire Department SOP

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

San Ramon Valley Fire Protection District

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

Wilton Fire Protection District. TRAINING DIVISION New apparatus

2017 Volunteer Week - Course Descriptions

Fire Apparatus Operator: Pumper

Apparatus Operator/Pumper

PERFORMANCE CRITERIA AND INSTRUCTIONS

Cozumel Turbodraft. Operational Considerations

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

Fire Apparatus Operator: Pumper

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

Driver Releasal Manual

ENGINE 260 REVISED

North Carolina Fire and Rescue Commission Live Fire Audit Form

Florissant Valley Fire Protection District Monthly Training Schedule

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

AUTOMATED PNEUMATIC TANKER HATCH

Iowa s s Minimum Training Standard. How to Be Prepared?

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

22. Specialty Valves.

Tanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

Emergency Vehicle Driver

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

17 15 NOVA SCOTIA FIRE SERVICE TRAINING EXTERIOR LEVEL (PHASE 2)

Ocean County Fire Academy. Fall 2018 Course Listings

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

Industrial Fire Brigade: Interior Structural

Evaluating 2-1/2 Direct Fill Lines Colton, New York

Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig Level of Instruction: In service personnel Time Required: 3 hours

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Chapter 1 FF I Orientation and Fire Service History

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

===============================================================

FSRS Relative Point Value Guide

Idaho Fire Service Technology Fire Fighter II

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

Standard Operating Procedures S.O.P. Sample Template Drafted by: Oklahoma State Firefighters Association Educational Advisory Committee

NEVADA STATE RAILROAD MUSEUM

Volunteer Firefighter Applicant Information Package

FIRE FIGHTER I EMERGENCY PROCEDURES WHEN USING SCBA TOPIC: TIME FRAME: 0:30. Level II LEVEL OF INSTRUCTION:

NFPA Firefighter 1 Skills Verification Task Book

Des Plaines Fire Dept. Engineer Program

Button style shirt and firefighting gloves are not required. (This will be a requirement in 2019.)

FIRE FIGHTER II JPR: FFII-1A

SINGLE VALVE WITH LOW-FLOW BYPASS

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P

Skilled and Technical Sciences Contests Contest Information

Establish and Deliver Water Supplies for fire fighting

KILGORE FIRE DEPARTMENT

SEPTEMBER 22-24, 2017

KJ4000 Operating Instructions & Parts Manual NSN

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Student Workbook SW2. Fireground Support operations

INSTALLATION AND OPERATION INSTRUCTIONS

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

WATER CONTROL SYSTEM QUICK START

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

TRAINING NEEDS ASSESSMENT DRILL

INCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL

Flow Material Length. Weight GPM LPM. Style 3095

USER GUIDE EMERGENCY PUMP KIT ULTRAFILTRATION ULTRAFILTRATION SYSTEMS. safe drinking water ULTRAFILTRATION UNIT FOR USE WITH:

Aqua Pilot Suction Pool Cleaner

20 10 SCOUT BLAST Fire Explorer Competition

Transcription:

W A T E R S U P P L Y O P E R A T I O N S R U R A L ( 2. 1 ) Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 Revised by Lt. Greg Van Heel, Eng. Chris Wining, and FF. Uriel Sanchez in Oct 2016 NFPA 1142 Standard on Water Supplies for Suburban and Rural Fire Fighting. T A S K S K I L L D E S C R I P T I O N A N D D E T A I L Having a consistent water supply in place is essential to support fire attack ground operations. In a rural setting acquiring a sustainable water supply can be very challenging due to the lack of available hydrants. In this environment, water tender shuttles, dump sites, fill sites, and nursing operations are common tactics used to create a water supply in a rural environment. Water Tender Shuttle Using apparatus to continually retrieve water from a remote location and drive it to the fire ground using onboard tanks. Dump Site - The dump site will be in the area of where the fire operation will commence. This is where the attack engine will be positioned and the port-a-tank operation will be set up. Fill Site The fill site will be located at the closest water source. When a hydrant is not available, a static water source such as a lake, pond, river, stream, or ditch is utilized to create a water supply for the operation. If this is the case, it is important to consider using a dedicated engine to set up a drafting operation to fill water tenders. Nursing Ops- Positioning a water tender or fire engine immediately adjacent to the attack engine and serving as a portable water reservoir rather than as a shuttle tanker. Water from the nurse engine/ tender will be pumped into the attack engine s intake.

Dump Site Equipment used to set up for a single port-a- tank drafting operation at the dump site. For this manual we will be using the 5 appliances in photos. Low level strainers, hard suction hose Removing the port-a-tank 1 The tools and appliances needed for a dump site include: 1) One to two sections of 2 ½ or 5 hard suction hose. 2) 2 ½ or 5 low level strainer. 3) One port-a-tank. Note: Removal of the port-a-tank is a minimum two person operation. 4) One basketball The purpose of the basketball is to float in the port-a-tank and keep air from being introduced into the low level strainer when a whirlpool occurs. Low level strainer and hard suction hose

Connect the hard suction hose to the intake on the driver s side of the pump panel. Hard suction hose into intake on driver s side. Make certain the connections are tight. If they are not secured tightly, air will be introduced into the system and in turn will disrupt the drafting process. The end result should look like the picture below. Hard suction hose and strainer secured tightly to intake.

Set-up and positioning the port-a-tank for operation When positioning the port-a-tank for operation the initial set-up is critical because it significantly impacts the incident. There are a few things you will want to keep in mind while setting up the tank such as water tender access to the tank, avoiding obstructing access to and from the incident, and incident operations. Position the port-a-tanks so they can be easily accessed by water tenders dumping water. It is favorable for port-a-tanks to be set up so that they can have multiple access points for tenders. Tank Placement Options Tank on DO side Tank in front Double tank Tank Corner Double Diamond If you are on a slope, position one of the drain chutes on the downward slope.

Setting up double porta-tanks for operation Setting up a second porta-tank will follow the same steps as in Task 1 to include a second port-a-tank and a jet siphon. The jet siphon will move water from one tank to another. Additional tools and appliances needed for the double tank include: 1) A second port-a-tank. 2) A second low level strainer. 3) A second 10-5 section of hard suction. 4) At least one section of 1 ¾ hose. 5) A second basketball. 6) Two straps or pieces of webbing. Set up the second port-a-tank Choose a configuration which allows best access by tenders off-loading water. Below are shown doublediamond and a side-by-side arrangements. Double Diamond Side-by-Side Jet Siphon Hard Suction Hose Low Level Strainer

Set up jet siphon Connect the 1 ¾ hose to a discharge on the engine and then connect it to the low level strainer. Once the connection is made you will then attach the second piece of 5 hard suction to the low level strainer. Set the second piece of hard suction into the second port-a-tank When setting the second piece of hard suction, the side with the low level strainer should be placed in the second port-a-tank and the other half of the hard suction should be placed above the first port-atank. Keeping the hose above the will prevent a backflow siphon from occurring when transfer has stopped. Strainer in 2 nd tank. End of siphon hose above 1 st tank. Tie off the hard suction and the 1 ¾ hose lines Be sure to tie both of these hose lines down. These are tied down because this part of the system will be charged and this will prevent them from moving out of place and possibly injuring someone.

Charge the jet siphon system Once everything is set up and there is water in the second port-a-tank you can now charge the jet siphon system. This will be done by the engineer charging the 1 ¾ line. Off-loading of water from a tender into the port-a-tank The water supply officer, or someone who has been designated by them, will be the one directing the water tenders into place at the dump site. The operator will have controls inside the cab for operating the chutes and will usually be the ones who will control this process. If not, there are typically controls on the outside of the apparatus as well.

Fill Site The fill site should be at the closest suitable water source. It is important to be aware that the closest water source may have some problems associated with it such as: 1) Traffic issues or unsuitable road conditions. 2) Water flow requirements. 3) Access to the water source (can the fill site engine position close enough). 4) Can other apparatus position and maneuver around easily within the site. NFPA 1901 recommends that tenders be filled at the rate of 1,000 GPM so keep this in mind when choosing a fill site. Utilizing a fire hydrant as a fill site: When hooking up to a hydrant, follow the instructions that you have seen in the municipal water supply portion of the training manual. With using the hydrant as a fill site however there will be a few items you will need keep in mind. 1) Make sure there will be plenty of room for apparatus to maneuver. 2) Make sure you use 5 hose when filling apparatus to cut down on the fill time. 3) Connect a 2 ½ gate valve to the hydrant in order to quickly relieve pressure when filling is complete. 4) A double hose setup can be used from the hydrant for faster filling. 5) If there is not a dedicated engine at the hydrant fill site, tools and appliances needed for the fill operation may be left in place. This will save time as each tender will not have to set up the system. Hydrant with 5 hose and 2.5 gate. Hydrant with double 5 hose for fast filling.

Using an Engine at the fill site to refill the Water Tenders. - Choose a 5 piece of hose to insure maximum transfer rate. - Connect the 5 fill hose to a discharge on the fill engine. - Connect the other end to an intake on the tender needing filled and open the valve. - Signal the engineer that the fill operation can commence. - Once the tank is full you can close the valve on the tender and disconnect the hose. Static water source for your fill site: When a static water source, such as a stream, ditch, or lake has been chosen, you will have to set up for drafting operations. If streamflow is low, you can create more depth by creating a small dam with rocks or using a tarp over a ladder to create water backup. Stream as water source. Pond as water source. Tarp and ladder to dam water.

Set up a drafting operation at a fill site At a static water source, you need to set up drafting operations and dedicate an engine to the fill site operation. Once that engine has set up a draft, it will stay there for the remainder of the incident. Step # 1 Locate tools and appliances needed for operation 1) 10 20 of hard suction hose. 2) Barrel strainer. 3) Attic ladder or roof ladder. Step # 2 Connect the barrel strainer to the hard suction hose When making the connection, ensure the connection is tight. The barrel strainer will prevent large debris from being introduced into the pump. Step # 3 Connect hard suction hose to the intake Verify all drains on the pump panel are in the closed position. As mentioned earlier, if air is introduced into the system, the draft will be disrupted and the engineer will have to spend valuable time regaining the draft.

Step # 4 Place a ladder in the static water source Placing a ladder in the static water source will ensure two things: 1) The ladder will prevent the barrel strainer from falling to the bottom of your static source keeping out debris that could slip by the strainer out of the pump. 2) There should be 24 of water space around the strainer, which is optimum when using a barrel strainer for drafting. Once this is done, the engineer will be the one actually obtaining the draft. Your water supply is now limited to the size of your static water source and size of the apparatus pump.

Nursing Operations A nursing operation is a water supply that involve water being fed from one apparatus (typically the water tender) to the other (typically the fire attack engine). A 5 or 2.5 hoseline is normally connected from the discharge on the Water Tender to the intake on the Attack Engine. Nursing operations are typically fast to set up and require minimal personnel, but water supply is limited by the size of the onboard water tanks. R E F E R E N C E I N F O R M A T I O N The following material was used for reference: NFPA 1142 Standard on Water Supplies for Urban and Rural Fire Fighting. IFSTA Pumping Apparatus Driver/Operator Handbook, First edition 1999 Jones and Bartlett Publishers, IAFC and NFPA Fundamentals of Fire Fighting Skills First Edition 2004. IFSTA Pumping Apparatus Driver/ Operator Handbook, Third Edition 2015