Control Charting: Lessons Learned Along the Way Why, What, and How

Similar documents
Controls and Control Charting

Quality Assurance Charting for QC Data

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

EN ISO/IEC Technical Requirements

TPM TIP. Oil Viscosity

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

The use of Control Charts with Composite materials. E. Clarkson, Statistician ASQ Certified Quality Engineer

Conservation Limits and Management Targets

Effects of Dissolved Gases in Surfactant Dissolution Media

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Any active ERDI Emergency Response Diver Instructor may teach this course

Laboratory and Satellite Rodent Housing

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Hazard Communication Plan (HCP) 29 CFR

Bioequivalence: Saving money with generic drugs

Laboratory Performance Assessment. Spring Report. Test Material B

Introduction. Seafood HACCP Alliance Training Course 8-1

Chemical Analysis for Methyltestosterone

1 June Presented by: Jeff Kiley Risk Management Directorate Program Executive Office Assembled Chemical Weapons Alternative

Mott Manufacturing Limited

Laboratory Performance Assessment. Spring Report. Test Material A

ANALYSIS REPORT. Report Date: February 16, :56. Project: SGPP - McCaffrey Street

United States Commercial Vertical Line Vessel Standardized Catch Rates of Red Grouper in the US South Atlantic,

SKAC25 Operate plant to maintain the quality of pool water

Extended Application Note

Autosampler problems!

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Codex Seven HACCP Principles. (Hazard Identification, Risk Assessment & Management)

Craig P. Seltenrich Pacific Gas & Electric Company 3400 Crow Canyon Road San Ramon, California Introduction

Air Handling Unit (AHU) Air handling unit which serves to condition the air and provide the required air movement within a facility.

Discussion and guidance on the definition and qualification of porous loads

Rate Charts: Gandy Spreaders 24, 36 & 42-inch Models

Statistical Method Certification, Coal Combustion Residuals Landfill, Reid Gardner Generating Station

APPLICATION NOTE. GC Integrated Permeation Device

Int r oduct ion t o Int egr it y Tes t ing Theor y

If you need to reinstall FastBreak Pro you will need to do a complete reinstallation and then install the update.

The Complete Stability Testing for a Successful Application. Strategies

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

GAS CHROMATOGRAPHY MAINTENANCE USING UNCERTAINTY BASED CBM

Dissolution Failure Investigation. Ken Boda Dissolution Applications Engineer

Gas mixtures. Individual solutions specifically for your application

Review of ISO10723 Performance Test Frequency. By Anwar Sutan

CHM Basics of Gases (r14) Charles Taylor 1/9

The following article was authored by Jacques Chaurette of Fluide Design, Inc. ( All rights reserved. - HOW DOES A SIPHON WORK?

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Determination of Zn using Atomic Absorption with Multiple Standard Additions

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Addendum to SEDAR16-DW-22

Denise L Seman City of Youngstown

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Frequently Asked Questions about Mechanical Qualification. Ken Boda Applications Engineer Agilent Technologies

Safety Analysis: Event Classification

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION. Stephanie Wilkins, PE EMA Workshop June 2017

July 3 Twenty lawns can be mowed in 35 hours. The lawns per hour are about 0.57 or just over a half of a lawn per hour.

Review of oxygen deficiency requirements for graham s ratio

Contingent Valuation Methods

STANDARD OPERATING PROCEDURES

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

QAM-I-117 Volumetric Equipment Calibration Verification

GSA POLICY ON LOCAL EXHAUST AND OTHER VENTILATION (FUME CUPBOARDS)

COMPANY NAME Title: Document: Effective Date: Supersedes Date: Reason For Revision:

ISDS 4141 Sample Data Mining Work. Tool Used: SAS Enterprise Guide

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

FISH 415 LIMNOLOGY UI Moscow

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Renzo BAGNATI Mario Negri Institute of Pharmacological Research- IRCCS Milano - Italy

Dev Food Industry. Procedure for HACCP Plan. To establish and maintain a uniform approach to establish HACCP Plan.

MATERIAL SAFETY DATA SHEET FILE NO.: AB Protein Kinases Landscape (large format) PEP kit MSDS DATE: 9 September 2013

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Jan 14, Jan 14, 2019 RECEIVED DATE Jan 07, 2019

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Index. Batch processing 56 Branching xiii 52 62

Running HPLC Methods on an ACQUITY UPLC System

Benefits of Detailed CFD Ventilation Analysis During Early Design Phases. Josué Quilliou Gexcon Consulting

Using the Akta Prime plus October 22, 2012

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

FAQs about Directive 017


Write the definition of each term in your own words. Then make a sketch to describe each term visually.

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Mar 13, Mar 13, 2018 RECEIVED DATE Mar 06, 2018

SOP-I-101 Operation and Calibration of the Analytical Balance

Choosing the Right Pump for Your Project

Country report. Swedish bathing water quality in Sweden. May Photo: Peter Kristensen/EEA

Gas chromatographic determination of 1,4-dioxane at the

Australian Supplement Survey Summary

FireWorks NFIRS BI User Manual

INSPECTION OF MEDICINAL GASES

API Standard Venting Atmospheric and Low-Pressure Storage Tanks: Nonrefrigerated and Refrigerated

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

SOP: Buck Scientific BLC-20P HPLC Operation

How To Win The Ashes A Statistician s Guide

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

7. Ranking the States with the Greatest Energy Intensity and Residual Effect Reductions

5.1 Introduction. Learning Objectives

Transcription:

Control Charting: Lessons Learned Along the Way Why, What, and How Stacie Hammack Florida Department of Agriculture and Consumer Services Food Laboratories

Why? Because it is required: ISO/IEC 17025 section 5.9 with numerous additional requirements within the AOAC Guidelines for Laboratories performing Microbiological and Chemical Analyses of Food and Pharmaceuticals Because it is a good idea: allows you to visualize changes in a method Done right, it can make calculation of measurement uncertainty easy

What to Control Chart In most cases, the answer is obvious; the value or percent recovery of the Laboratory Control Sample (LCS) that is run with each batch of samples But...what about qualitative methods? What about screening methods? What about methods that are estimates like Most Probable Number (MPN) methods?

How to Determine Appropriate Control Chart Limits Fixed limits versus moving average limits Do I have to use + 3SD for my control chart limits? How do I determine a limit for a screening method? How do I determine a limit for a qualitative method?

Qualitative Methods I have a method that is presence/absence, what do I control chart? This has to be evaluated on a case by case basis Our HPLC method for artificial colors is a presence/absence method based on a retention time match and a spectral match to the standard

Charting of Spectral Match

Screening Methods Most screening methods are based on an analyte exceeding some predetermined limit. The control sample itself should be at a level meaningful to the determination Usually, a positive sample from a screen is then confirmed using another method Much like control charting of qualitative methods, charting of screening methods has to be evaluated on a case by case basis Some questions to ask are: Does the upper limit matter? Does the lower limit matter? How good is my screening method? What level does the analyte have to be before I make a regulatory determination or go to a confirmation method

Aflatoxin Screening Control Limits A method used to screen out negative samples and reduce the number of samples requiring HPLC confirmation What do I want to control, false positives (high recoveries) or false negatives (low recoveries)? Do I care about the upper limit for the control chart? The upper control chart limit is not critical to this method Do I care about the lower control chart limit? The lower control chart limit is critical to this method Do I care about the average? No, not really

Aflatoxin Screening Facts The regulatory limit for corn and peanuts is 20ppb. Our control samples are corn and peanut butter at levels as close to 20ppb as we can find acceptable controls. Our screening method is an immuno affinity column cleanup with determination by a fluorometer. It specifies that any sample at 10ppb or higher will be confirmed by HPLC.

Aflatoxin Screening, Setting the Lower Control Limit Have I establish some critical value for the lower control limit? Yes! With the statement that all samples screened at or above 10ppb, which is 50% of the regulatory limit, a critical value was established. Does my lower limit have to be 50% recovery? No, if the method performs better than that, or there is a high bias, then your lower limit should be greater than 50% recovery. Does my lower limit have to be 50% recovery? Unless the criteria for which samples move on to confirmation is changed, there is no justification for setting your lower control limit below 50% recovery it would no longer be fit for purpose

Control Chart for Aflatoxin in Peanut Butter

Control Chart for Aflatoxin in Corn

What to Control Chart for MPN Methods Our laboratory uses a commercially produced pellet of known value for the control sample We have tried control charting the log 10 value of the control sample, the percent recovery based on the log 10 value (from the expected value), and the number of positive MPN tubes (water samples only, no dilution). Each option for control charting MPN has its pros and cons there is not a best method

MPN Control Charting and Lessons Learned MPN is an estimate: Most Probable Number Add in variability from the pellets, especially if there are problems with the dissolution of the pellets or clumping Additional dilutions of the control that are not done to the customer samples can result in additional variation in the control that is not seen in the samples There are a finite number of possible answers so there tends to be clusters of the same result There is a ceiling beyond which there cannot be any other answer for a given dilution All of these factors combined cause the MPN control charts to behave differently than other control charts

Charting Log 10 value of MPN Results Pro: very simple for the analyst to enter the control values Con: Control Charts have to be changed when pellet lots change due to the change in expected value for the organism Con: This method can give very large apparent ranges Con: Does not give useful information if needed for calculation of MU

Log 10 MPN with High Variability: The Early Days

% Recovery from Log 10 values Still simple to enter the control values, but does require a calculation and knowing the expected value Pro: Control Charts do not have to be changed when pellet lots change that is accounted for in the calculation Calculating as % Recovery does smooth the chart though there can still be large apparent ranges Pro: This can be used to help with determination of Measurement Uncertainty (MU) if needed

Normal Distribution using % Recovery with MPN

% Recovery Chart for MPN: Today Use of CRM for Control Sample

Number of Positive Tubes in MPN Used for our bottled and vended water method MPN is used if samples are not suitable for analysis by membrane filtration Water has a very low regulatory limit Control sample concentration is low, but still turns most MPN tubes positive Control chart is of limited use for the calculation of MU

Control Chart of Number of Positive MPN Tubes

Dealing with Exceptions to Control Chart Requirements For my laboratory, the main SOP governing Control Charting gives general guidelines and those rules are programmed into the control chart application (circles are trending, squares are out of control) The Control Chart SOP allows for exceptions to be specified in specific method SOPs The method SOP will state if there is an exemption to the requirements of the Control Charting SOP Analysts refer to the method SOPs more often than they do to the Control Chart SOP; the method SOP will tell them if they can ignore a trending point out of control points always require a corrective action