An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR - A manikin study

Similar documents
ANZCOR Guideline 6 Compressions

The Concept of Q-CPR. The need for Quality CPR

What is the Role of Chest Compression Depth during Out-of-Hospital CPR?

2015 Guidelines Summary HeartSine samaritan PAD Automated External Defibrillators

Development of Android Based Chest Compression Feedback Application Using the Accelerometer in Smartphone

Q-CPR Measurement and Feedback Application Note

CPR: Are You a Machine or Do You Need One?

High Quality CPR: Demonstration and Analysis. Conflict of Interest (COI)

Peter J. Kudenchuk, MD University of Washington

EVIDENCE-BASED RESEARCH. Rescuer Fatigue in Cardiopulmonary Resuscitation: A Review of the Literature

Enhancing 4 th chain: Mechanical chest compression during transportation

New method of chest compression for infants in a single rescuer situation: thumb-index finger technique

Abstract. Keywords. Kyoko Tsukigase 1, Hideharu Tanaka 1,2, Hiroshi Takyu 2

University of Warwick institutional repository:

Rescuer Fatigue: Standard versus Continuous Chest-Compression Cardiopulmonary Resuscitation

LIFEPAK. CR2 Defibrillator. Better technology for better outcomes. Essential version

Resuscitation Science

12/03/2013. Conflict of interest. ERC 2010 Guidelines. Waar is nog winst te behalen in het reanimatieonderwijs?

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Academic Grant CPR process monitors provided by Zoll. conflict of interest to declare

Influence of rescuer strength and shift cycle time on chest compression quality

Guide to Compression-only Bystander CPR

community (out -of -hospital); thus, the success of the the willingness to perform CPR and decrease the fear of imperfect CPR performance.

AED Plus AL The Best Support For Rescuers

EMD CPR. The First First Responder. R. Darrell Nelson, MD, FACEP

Resuscitation Council of Southern Africa


Guidelines 2005 for Basic Life Support

CPR Quality During OHCA Transport

AutoPulse. Mechanical CPR. in the Hospital

EMD CPR. The First First Responder. R. Darrell Nelson, MD, FACEP. Emergency Medicine Wake Forest University Baptist Health

On-Scene Resuscitation. Brent Myers, MD MPH Director Medical Director Wake County EMS, Raleigh, NC

Basic Life Support. Based on UK Resuscitation Guidelines (2010)

THE SYSTEM FOR HIGH-QUALITY CPR

Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment

ABC versus CAB for cardiopulmonary resuscitation: a prospective, randomized simulator-based trial

High-Functioning EMS CPR Teams. Sally A Taylor - Paramedic Atlantic Partners EMS

A study comparing the usability of fully automatic versus semi-automatic defibrillation by untrained nursing students

Cardiac Arrest Cases and Automated External Defibrillator Use in Railroad Stations in Tokyo

Talking about teaching CPR at schools

UTSW/BioTel EMS System Training Bulletin June 1, 2015 EMS TB Adult CPR Update: Change to Continuous Chest Compressions (CCC)

MANAGEMENT OF COLLAPSED ADULT PATIENT

Save a life CPR Practice. CPR and AED practice for general public

AED Plus. The Best Support For Rescuers

Association of arterial blood pressure and CPR quality in a child using three different compression techniques, a case report

DESIGNED FOR PROFESSIONAL RESCUERS

Cardiac Arrest General

THIS STUDY WAS approved by the ethics committee

Frequently Asked Questions About AEDs updated 11/2/2015

European Resuscitation Council. Basic Life Support & Automated External Defibrillation Course

Prof. dr. P. Calle Emergency physician Ghent University Hospital, Belgium No conflict of interests

Introducing Intellisense CPR Feedback Sensor and Technology Overview. Internal Use Only Not For Distribution

CMEARTICLE. HIGHLIGHTS OF CHANGES IN BCLS GUIDELINES SINCE 2010 Recognition of cardiac arrest. Technique of chest compression

Resuscitation 81 (2010) Contents lists available at ScienceDirect. Resuscitation. journal homepage:

Hot Topics in Telephone CPR

Basic life support updates

Rainer Nitzschke 1*, Christoph Doehn 1, Jan F. Kersten 2, Julian Blanz 1, Tobias J. Kalwa 3, Norman A. Scotti 3 and Jens C.

Comparison of the Conventional and Hands-only Cardiopulmonary Resuscitation Skills Performance of Some Nigerian University Students

Proficiency with Zoll in Manual Mode: There is a new Dashboard screen that you will see on the Zoll while in manual mode

Once student shouts for help, instructor says, Here s the barrier device. I am going to get the AED. STOP TEST

Training Presentation. TFD-EMS Ver. 1 09/15

QCOVER1.qxd 11/17/05 1:50 PM Page 4

LUCAS 2 Mechanical Chest Compression Device

Ain't Nobody Got Time for That Epi, Fool: ACLS in the 20-Teens Comes of Age Disclosures Updated Syllabus

Basic Life Support Adult

CPR competition 2016 Rules. The ERC Congress on Education. Reykjavik, Iceland

Basic Life Support & Automated External Defibrillation Course. OBJECTIVES

This presentation should be viewed in its entirety by rescuers being trained for the first time on LUCAS.

County of Henrico Verification Originator Revised Issued Human Resources Initials Risk

Achy breaky makey wakey heart? A randomised crossover trial of musical prompts

AED Plus. The Best Support For Rescuers

ORIGINAL ARTICLE Emergency & Critical Care Medicine INTRODUCTION

Even Better Support For. Professional Rescuers

AED Plus. The Best Support. For Rescuers

Bystander s bravery and action can rescue a life of victims. Guideline Training Course

A Turbine-Driven Ventilator Improves Adherence to Advanced Cardiac Life Support Guidelines During a Cardiopulmonary Resuscitation Simulation

CPR + AED Topic 6 TECS TECS FIRE & SAFETY TRAINING PTE LTD

BLS Guideline 3 COMPRESSIONS

Chest Compression-only Cardiopulmonary Resuscitation in Nigerian University Students

Evaluation System for Chest Compression Training Shinnosuke-kun

Overview. The user must follow the instructions below.

Even Better Support For Rescuers

At the end of this course participants should be able to demonstrate:

Health Informatics Journal

THE AED THAT LEADS THE WAY

DECLARATION OF CONFLICT OF INTEREST

American Heart Association Health Care Provider CPR 2010 Curriculum

Key statistics from the National Cardiac Arrest Audit 2016/17

AED Plus. The Best Support For Rescuers

LUCAS CHEST COMPRESSION SYSTEM PRODUCT BROCHURE

Resuscitation 85 (2014) Contents lists available at ScienceDirect. Resuscitation. journal homepage:

CPR & ECC COURSE MATRIX

How might GRADE work for ILCOR? Summary of specific components of GRADE using example worksheet

bls guidelines B42EFDD89A9AB6A33D869587D2D61D4E Bls Guidelines 1 / 6

New pre-arrival instructions can avoid abdominal hand placement for chest compressions

Journal of Problem-Based Learning. The effect of rescuers body mass index on chest compression performance during simulation training in Hong Kong

Minimum equipment list for cardiopulmonary resuscitation Primary dental care

SMJ Singapore Medical Journal

AMERICAN HEART ASSOCIATION UPDATES:

March 2018 FSN Medical Device Recall/Notification HeartStart FRx, HeartStart Home, and Heartstart OnSite AEDs

Transcription:

Hiroshima J. Med. Sci. Vol. 63, No. 1-3, 7~11, September, 2014 HIJM 63 2 7 An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR - A manikin study Yoshitaka SHIMIZU 1,*), Koichi TANIGAWA 2), Masami ISHIKAWA 3), Kazuhisa OUHARA 4), Kana OUE 1), Taiga YOSHINAKA 1), Hidemi KURIHARA 4) and Masahiro IRIFUNE 1) 1) Department of Dental Anesthesiology, Division of Integrated Health Sciences, Graduate School of Institute of Biomedical & Health Sciences, Hiroshima University, Hiroshima 734-8551, Japan 2) Department of Emergency and Critical Care Medicine, Division of Applied Life Sciences, Graduate School of Institute of Biomedical & Health Sciences, Hiroshima University, Hiroshima 734-8551, Japan 3) Department of Anesthesiology and Critical Care Medicine of Kure Kyousai Hospital, 2-3-28 Nishichuo, Kure-city, Hiroshima 737-8505, Japan 4) Department of Periodontal Medicine, Division of Applied Life Sciences, Institute of Biomedical & Health Sciences, Hiroshima University, Hiroshima 734-8551, Japan ABSTRACT It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive oneminute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p<0.05 vs. the first set). However, no significant differences were observed between the first and second sets at pace-100-g and pace-90-g. The results obtained for pace- 110-g were compared in detail by gender. In the male group, the percentage of compressions deeper than 5 cm was 43.5 ± 7.5% in the first set, and this decreased significantly to 34.6 ± 7.6%* in the second set (*p<0.001 vs. the first set). However, the percentage of compressions deeper than 5 cm in the female group was 2.3 ± 1.6%* in the first set and 0.2 ± 0.2%* in the second set (*p<0.05 vs. male). Our study demonstrated that the compression pace of 110 compressions per min was inadequate to provide chest compressions of an appropriate depth, which decreased rapidly. Therefore, limiting the rate of compressions to within a certain number per min may contribute to minimizing deteriorations in compression depth in hands-only CPR. Key words: Hands-only CPR, Chest compression, Compression pace High quality chest compressions with an appropriate compression pace may facilitate the successful return of spontaneous circulation (ROSC) 7,12). A previous study investigating the rate of chest compressions demonstrated that optimal blood flow could be obtained by maintaining chest compressions at a rate of at least 100 per min 9). Accordingly, a rate of chest compressions faster than 100 per min was recommended by the American Heart Association (AHA) 2010 Guidelines (G2010) 3). However, the rate of chest compressions is often much lower during training and actual CPR attempts 1,15,18). An improved survival rate was reported in a clinical study of out- of-hospital cardiac arrest when chest compressions were implemented at a mean chest compression rate of above 110 per min 4). Faster chest compression rates also improved ROSC and 24h survival rates after ventricular fibrillation in an animal study 8). Thus, the implementation of a good quality chest compression pace to obtain ROSC is important. In a previous study, males performed chest compression of greater quality compared with female participants 16). Therefore, chest compression rate *Corresponding author: Yoshitaka Shimizu; Department of Dental Anesthesiology, Division of Integrated Health Sciences, Graduate School of Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima 734-8551, Japan Tel: 082-257-5733 Fax: 089-82-257-5779 E-mail: yshimizu@hiroshima-u.ac.jp

8 Y. Shimizu et al and depth are compared here according to gender. The recommended chest compression rate has increased in recent years with every amendment to the AHA guidelines. In the AHA Guidelines 2010, the recommended rate of chest compressions is at least 100/min, while it was stated as about 100/min in the 2005 recommendation 5). However, the European Resuscitation Council Guidelines 2010 recommended an upper compression rate of 120/min 10). An appropriate compression pace is important to ensure the quality of chest compressions. Recent findings have revealed that a reduction in compression quality was more evident in chest-compressiononly CPR than in standard CPR after 90 sec 14), although this effect may not be significant for ROSC. In the present study, we measured the chest compression depth of different compression rate variables using a metronome sound guide when compression-only CPR was performed on a manikin by rescuers according to the G2010. MATERIALS AND METHODS Participants, ethical considerations, and study design Fifty sixth-year dentistry students agreed to participate in this study, which was approved by the Ethics Committee of Hiroshima University Graduate School of Medicine. All procedures were conducted according to the Declaration of Helsinki. The participants in this study were students in the same school year who had received the same CPR training at Dental School. Participants were instructed to perform chest compressions according to the G2010 (compression depth >5 cm) prior to the experiment. Each participant performed CPR at 3 different compression rates using a metronome sound guide with at least a 30-min rest between each 2-min set of compressions. An electronic metronome with an audible beeping tone was used to guide participants on the chest compression rate. 110, 100, and 90 compressions per min (pace-110, pace-100, and pace-90) were performed on the chest of a manikin at the sternum level (ALS Skillmeter, Laerdal Medical, Norway) for 2 consecutive one-minute sets with a ten-second break between the sets. Data were collected in a separate room without a clock, and oral announcements were made during the experiment. In previous studies, it was reported that applying a backboard significantly increased chest compression depth during cardiopulmonary resuscitation of a manikin. Therefore, our study subjects were asked to perform chest compressions on the hard floor. Measurement & Statistical quality of chest compressions We counted the number of chest compressions and those with an appropriate depth during each min of the CPR period in a manikin equipped with a ALS Skillmeter & Heartsim 4000 (Laerdal Medical, Stavanger, Norway). An appropriate depth was defined as 5 cm or more by the G2010. Data were compared between groups using the Student s t-test and repeated measures two-way analysis of variance (ANOVA). Values are shown as the mean ± the standard error (SEM). Analyses were performed using Stat View (SAS Institute, San Francisco, USA). Results were considered significant when p was less than 0.05. RESULTS The number of participants in each pace group (pace-110, pace-100, and pace-90) was 50. Table 1 shows the height, weight, completion of an AHA BLS provider course, and age of the participants (Table 1). The average number of chest compressions was measured at each pace. The average numbers of chest compressions in the first and second sets were 109.2 ± 1.4 and 109.2 ± 1.6 compressions per min, respectively, in the pace-110 group, 99.9 ± 1.3 and 99.5 ± 1.2 in the pace-100 group, and 89.7 ± 1.1 and 89.7 ± 1.1 in the pace-90 group. No significant difference was observed in the average number of compressions between the first and second set at each pace. Table 1. Baseline characteristics of male and female participants Values are shown as the mean ± S.E.M. *p<0.0001 (non-paired t-test: vs Male) AHA BLS course: American Heart Association Provider course. CPR: Cardiopulmonary Resuscitation.

An Appropriate Chest Compression Pace in Hands-only CPR 9 Figure 1 shows time-course changes in the number of chest compressions performed by male and female participants at each pace. The number of compressions performed in the second set was significantly higher in males than in females in the pace-110 group (109.7 ± 0.3 vs. 108.8 ± 0.3*, *p<0.05, respectively). The number of females able to maintain a rate faster than 110 per min was significantly lower in the second set than in the first set (Fig. 1). A slight decrease in the number of compressions performed during the whole 2-min study period was observed only in females in the pace-110 group. Figure 2 shows the percentage of compressions performed by male and female participants that reached 5 cm or deeper in the first and second sets of each pace. Compressions performed by male and female participants in the pace-110 group were compared in detail. In males, the percentage of compressions deeper than 5 cm of 43.5 ± 7.5% in the first set was significantly higher than that of 34.6 ± 7.6%* in the second set (*p<0.001 vs. the first set). However, in females, the percentages of compressions deeper than 5 cm in the first set and second set were 2.3 ± 1.6%* and 0.2 ± 0.2%* (*p<0.05 vs. male). On the other hand, pace 90 and pace 100 were not decreased in the second set (Fig. 2). Fig. 1. Time-course changes in the number of chest compressions performed by male and female participants in each group. Values are shown as the mean ± S.E.M. *p<0.05 (two-way ANOVA: between both groups) Fig. 2. The percentage of compressions performed by male and female participants that reached 5 cm or deeper in the first and second sets in each group. *p<0.001 (Paired t-test: between both groups) DISCUSSION Chest compressions are the most important treatment affecting the ROSC of cardiac arrest. The G2010 for CPR recommended that untrained bystanders should perform chest-compression-only CPR with an emphasis on push hard and fast (a chest compression depth of >5 cm at a rate of >100 compressions per min). A faster chest compression rate was shown to improve immediate and 24h survival rates following ventricular fibrillation arrest in an animal study 8). Clinical studies have also reported improvements in survival due to a faster compression rate 2). However, faster compression rates induce rescuer fatigue, which, in turn, decreases the quality of CPR. Therefore,

10 Y. Shimizu et al 1. Abella, B.S., Alvarado, J.P., Myklebust, H., Edelson, D.P., Barry, A., O Hearn, N., et al. 2005. Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest. JAMA. 293: 305-310. 2. Abella, B.S., Sandbo, N., Vassilatos, P., Alvarado, J.P., O Hearn, N., Wigder, H.N., et al. 2005. Chest compression rates during cardiopulmonary resuscilimiting the rate of compressions to within a certain number per min minimizes deteriorations in the depth of compressions. The influence of the chest compression rate on the depth of compressions performed by a single rescuer has yet to be determined. Our study showed that a chest compression pace of 90-110 per min for 2 min on a manikin whilst maintaining the chest compression depth recommended by the G2010 was not feasible. The main drawback to a faster compression rate was a significant decrease in the depth of compressions performed by both male and female participants. However, no significant decrease was observed in the depth of chest compressions performed over 2 min in the pace-100 and pace-90 groups, and the chest compression depth was maintained to an acceptable level according to the G2005. Furthermore, the female group showed a significant decrease in the number of chest compressions during pace-110 between the first set and second set. These findings suggest that maintaining the quality of chest compressions, i.e., appropriate p, in accordance with the G2010, may be difficult to achieve for females. Recent studies on adult CPR have suggested that the rates of defibrillation success and ROSC may be improved by performing chest compressions to a depth deeper than 5 cm 8). In addition, even deeper compressions were shown to lead to a higher survival rate in dogs 6). Therefore, the G2010 recommends that at least 100 chest compressions deeper than 5 cm per min should be maintained during CPR 9). However, a clinical study of in-hospital cardiac arrest revealed that sternal and rib fractures are frequent complications of chest compressions performed at an exact and ideal depth of chest compressions 11). These findings suggest that maintaining the quality of chest compressions, i.e., appropriate depth, in accordance with the G2010 may exceed the recommendation for chest compression. On the other hand, the compression rate and total number of compressions are important for maintaining the quality of CPR 2). The results of the present study showed that the chest compression rate did not decrease over time in the 3 groups. However, the total number of compressions performed was markedly higher and the number of compressions performed at the proper depth was markedly lower in the pace-110 group than in other groups. These results indicated that participants were unable to maintain the quality of chest compressions at a pace of 110 per min. As seen in other studies, when rescuers were provided with a rest period during continuouschest-compression (CCC) CPR (for example, a 10-s rest after 100 chest compressions), the mean chest compression depth and percentage of adequate compressions were higher than those during CCC without rest 13). Chika and coauthors reported that CPR quality during CCC-CPR with rest decreased after 1 min compared with conventional CPR 14). Our study protocol may also be different from actual continuous chest-compression CPR, which is performed without intervals for artificial respiration. There are several limitations to this study. First, the number of participants was small. Second, we used a manikin equipped with an ALS Skillmeter (Laerdal Medical, Stavanger, Norway) that requires a force of more than 45 kg to generate a compression deeper than 51 mm. This is the average force required to perform chest compression by a lay person 17). As a result, patient outcomes from different chest compression paces were not measured. We were unable to confirm how much force is required to perform a chest compression by a real lay person. Patient outcomes from different chest compression paces were also not measured. Third, we could not measure the average depth for chest compressions because the numerical count system of HeartSim 4000 (Laerdal Medical, Stavanger, Norway) was used in this study. Finally, we did not compare the quality of chest compressions with those performed during conventional CPR. CONCLUSIONS The present study compared the quality of chest compressions performed at three different paces by dentistry students. The depth of chest compressions at a rate of 110 compressions per minute was inadequate and decreased more rapidly over the 2-min test period. Female students were unable to deliver chest compressions deeper than 5 cm from the first set. We consider pace-100 to be a reasonable limit for the rate of compressions performed per min in order to minimize deteriorations in compression depth in chest-compressions-only CPR for dentistry students. ACKNOWLEDGEMENTS The authors sincerely thank the dentistry students at Hiroshima University who participated in the study. (Received April 17, 2014) (Accepted June 20, 2014) REFERENCES

An Appropriate Chest Compression Pace in Hands-only CPR 11 tation are suboptimal: a prospective study during in-hospital cardiac arrest. Circulation 111: 428-434. 3. Berg, R.A., Hemphill, R., Abella, B.S., Aufderheide, T.P., Cave, D.M., Hazinski, M.F., et al. 2010. Part 5: adult basic life support: 2010 American Heart Association guideline for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 122: S685-705. 4. Christenson, J., Andrusiek, D., Everson-Stewart, S., Kudenchuk, P., Hostler, D., Powell, J., et al. 2009. Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation. Circulation 120: 1241-1247. 5. ECC Committee, Subcommittees and Task Forces of the American Heart Association. 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 112: IV19-34. 6. Edelson, D.P., Abella, B.S., Kramer-Johansen, J., Wik, L., Myklebust, H., Barry, A.M., et al. 2006. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 71: 137-145. 7. Edelson, D.P., Litzinger, B., Arora, V., Walsh, D., Kim, S., Lauderdale, D.S., et al. 2008. Improving in-hospital cardiac arrest process and outcomes with performance debriefing. Arch. Intern. Med. 168: 1063-1069. 8. Feneley, M.P., Maier, G.W., Kern, K.B., Gaynor, J.W., Gall, S.A., Jr., Sanders, A.B., et al. 1988. Influence of compression rate on initial success of resuscitation and 24 h survival after prolonged manual cardiopulmonary resuscitation in dogs. Circulation 77: 240-250. 9. Halperin, H.R., Tsitlik, J.E., Guerci, A.D., Mellits, E.D., Levin, H.R., Shi, A.Y., et al. 1986. Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs. Circulation 73: 539-550. 10. Handley, A.J., Koster, R., Monsieurs, K., Perkins, G.D., Davies, S. and Bossaert, L. 2005. European Resuscitation Council guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 67: S7-23. 11. Hellevuo, H., Sainio, M., Nevalainen, R., Huhtala, H., Olkkola, K.T., Tenhunen, J., et al. 2013. Deeper chest compression - more complications for cardiac arrest patients?. Resuscitation 84: 760-765. 12. Kramer-Johansen, J., Myklebust, H., Wik, L., Fellows, B., Svensson, L., Sørebø, H., et al. 2006. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 71: 283-292. 13. Min, M.K., Yeom, S.R., Ryu, J.H., Kim, Y.I., Park, M.R., Han, S.K., et al. 2013. A 10-s rest improves chest compression quality during hands-only cardiopulmonary resuscitation: a prospective, randomized crossover study using a manikin model. Resuscitation 84: 1279-1284. 14. Nishiyama, C., Iwami, T., Kawamura, T., Ando, M., Yonemoto, N., Hiraide, A., et al. 2010. Quality of chest compressions during continuous CPR; comparison between chest compression-only CPR and conventional CPR. Resuscitation 81: 1152-1155. 15. Olasveengen, T.M., Tomlinson, A.E., Wik, L., Sunde, K., Steen, P.A., Myklebust, H., et al. 2007. A failed attempt to improve quality of out-of-hospital CPR through performance evaluation. Prehosp. Emergency Care 11: 427-433. 16. Peberdy, M.A., Silver, A. and Ornato, J.P. 2009. Effect of caregiver gender, age, and feedback prompts on chest compression rate and depth. Resuscitation 80: 1169-1174. 17. Tomlinson, A.E., Nysaether, J., Kramer-Johansen, J., Steen, P.A. and Dorph, E. 2007. Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation. Resuscitation 72: 364-370. 18. Wik, L., Kramer-Johansen, J., Myklebust, H., Sørebø, H., Svensson, L., Fellows, B., et al. 2005. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA. 293: 299-304.