STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

Similar documents
MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

Electro-Proportional Valves. Selection Guide HYDRA FORCE

PRESSURE COMPENSATORS TECNORD

Chapter 10: Bidirectional Flow Controls

Full Range Pressure Compensating Variable Flow Control

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Lesson 6: Flow Control Valves

Copyright, 2005 GPM Hydraulic Consulting, Inc.

BACK PRESSURE / SUSTAINING

PTS1120TSJB PTS2120TSTSJB

BACK PRESSURE / SUSTAINING

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Hydraulic Reliability & Preventive Maintenance Report

Models 106-RF / 206-RF Rate of Flow Control Valve

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Hydraulics. Hydraulic Pressure Control

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

P.C. Flow Regulator Valve Series FR101. General Description

P r o d u c t R a n g e Data sheet: P

SINGLE VALVE WITH LOW-FLOW BYPASS

IFP C175-* REMOTE CONTROL RELIEF VALVE

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

PVK OPEN LOOP PUMPS. Bulletin E

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

ANTI SHOCK RELIEF VALVE

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Waterous Relief Valve

Electrically Operated Pressure-Relief Cartridge, Size 10

PVQ 13 A2 R SE 1 S 20 C-11 D

Monoblock Directional Control Valve RMB 202

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

SDM to 8 sections monoblock valve D1WWDA02A

WORKHOLDING APPLICATION BOOKLET

Cartridge Valves Technical Information Motor Mount HICs Quick Reference

Bulletin 2537-M2/USA Service Bulletin Series PRM

Axial piston pumps type PVC

Axial piston pumps type PVC

Whisper Pump Service and Repair Guide

Inverse Proportional Pressure-Relief Cartridge, Size 10

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

CASH VALVE TYPE KP BACK PRESSURE VALVES

Pilots Specifications

[You may download this article at: ]

Proportional Directional Valve System

PVV Open Loop Pumps. Bulletin E

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Document How to Set Single Stage Press Pressures

TECHNICAL DATA. than the water inlet pressure to the concentrate

Leak-Free Load-Control Valve SAE ½ psi flange

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Inverse Prop. Pressure-Relief Cart., Size 2 4

Controllers DR, DP, FR and DFR

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Hydronic Systems Balance

Cover headline. Cover subheadline. Check Valves

Leak free Pipe Rupture Valve for Excavators

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Priority (Swing) Motors Data and Specifications

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB

WW-730. Pressure Sustaining/Relief Control Valve

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inert Air (N2) Systems Manual

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

SERVICE MANUAL No. I-0043

Proper Pump Installation Practices

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Ratio Regulator Zero Governor. FRG/6 Series

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Pressure on Demand. Air Pressure Amplifiers

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Directional Control valves

Directional Controls

D62 - D63 Directional Control Valve l/min

TotalPac X Single interlock Preaction system Electric release

AS0403 Aircraft Systems & Instruments G.Mahendra Perumal

LPK1230 Hydraulic Crimping Tool 12 ton

Bobtail DOT 407 / 412 Vacuum

Discharge Relief Valve Operation & Maint.

Booster Regulator/Air Tank

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Liquid level regulating valves Types PMFL / PMFH and SV

Unit 24: Applications of Pneumatics and Hydraulics

(Refer Slide Time: 0:26)

Section 2 Proportional Quick Exhaust

directional control valve series cv691

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

SERVICE INSTRUCTIONS P-2 DUAL PRESSURE COMPENSATOR, SERIES F1U CONTROL

Transcription:

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS Muncie Power Products, Inc.

TABLE OF CONTENTS DESCRIPTION PAGE Features... 3 Hydraulic Specifications... 3 Workports... 4 Stand Alone Spreader Manifold... 5 Open Center Schematic... 6 Load Sense Schematic... 7 Relief Valve Adjustment... 10 Detailed Description of Stand Alone Spreader...9-11 2

STAND ALONE SPREADER FEATURES FOR GEAR PUMP APPLICATIONS Unloader for low pressure loads when not operating equals low heat and low energy consumption. DIRECT ACTING SOLENOID PROPORTIONAL VALVES For consistent and predictable flow control. POST PRESSURE COMPENSATION Flow stability under varying load. VERSATILE 2 DESIGN OPTIONS Load Sense (variable displacement pumps) or Open Center (fixed displacement pumps). 2 ADJUSTABLE RELIEF VALVES One inlet relief and one output relief. HYDRAULIC SPECIFICATIONS Maximum Inlet Flow... 30 GPM Maximum System Pressure...3,000 PSI Unloaded Pressure Drop... 40 PSI AT 25 GPM Auger Flow (Proportional)... 15 GPM (Pressure Compensated) Spinner Flow (Proportional)... 7 GPM (Pressure Compensated) Main Relief... Factory Setting 2,200 (PSI Adjustable) Spreader Relief... Factory Setting 2,000 (PSI Adjustable) 3

WORKPORTS DESIGNATION DESCRIPTION SIZE (SAE) T TANK 12 T2 TANK 12 P PUMP 12 P2 PUMP 16 A AUGER 12 S SPINNER 12 LS LOAD SENSE 4 PGP PUMP GAGE PORT ¼" NPTF 4

STAND ALONE SPREADER MANIFOLD CARTRIDGE DESIGNATIONS, FUNCTIONS, & PART NUMBERS PV1 Spinner Pressure Compensated Flow Control NXPV7030AM0N00 PV2 Auger Pressure Compensated Flow Control NXPV7220M0N00 EV1 Pump Unloader NXEV16S340N10 LS1 Load Sense Shuttle NXLS08300N00 TS1 Main System Relief NXTS3820M0N12ER CP1 Cavity Plug NXVC042 CV1 Boost Pressure Check NXCV08200N270 RV1 Auger/Spinner Relief NXRV0820H0N1820 SV1 Pump Unloader Pilot NXSV0821K0N0 COIL PART NUMBERS SV1 NX4303612 PV1 NX4303212 PV2 NX4303212 5

OPEN CENTER SCHEMATIC 09/23/15 P2 P PGP PV1 S CV1 LS1 A ORF1 PV2 EV1 SV1 TS1 CP1 RV1 T T2 LS TS1 6

LOAD SENSE SCHEMATIC 09/23/15 P2 P S PGP CP3 PV1 LS1 A ORF1 PV2 EV1 CP2 TS1 CP1 RV1 T T2 LS TS1 SV1 Replaced with CP2 (NXCP0820N) in LS Configuration CV1 Replaced with CP3 (NXCP0820N) in LS Configuration 7

STAND ALONE SPREADER RELIEF VALVES To Decrease the Pressure Settings 1. The tools required to adjust the relief valves include a 5 16" Allen drive and a ¼" Allen drive. 2. Remove the caps from both of the relief valves. Oil may seep out of these cartridges when the caps are removed and the system is operating. TS1 3. Place A gage in the PGP port. If not accessible, tee a gage in between the Pump Outlet and the Pressure Port (P) of the MESP202H. 4. Start the truck and Deadhead flow at either the Auger or Spinner. 5. Observe the gage in the L.S. port and adjust the auger/spinner relief CCW to the desired pressure. 6. Observe the Gage in the (PGP) port. Adjust the main relief CCW until it is approximately 200 P.S.I. higher than the L.S. gage. To Increase the Pressure Settings (3,000 P.S.I. Max.) 1. The tools required to adjust the relief valves include a 5 16" Allen drive and a ¼" Allen drive. 2. Remove the caps from both of the relief valves. Oil may seep out of these cartridges when the caps are removed and the system is operating. 3. Place A gage in the PGP port. If not accessible, tee a gage in between the Pump Outlet and the Pressure Port (P) of the MESP202H. 4. Start the truck and Deadhead flow at either the Auger or Spinner 5. Both reliefs will need to be adjusted in small increments together. 6. Adjust the Auger/Spinner relief CW while observing both gages stop turning when there is no change in the gage. 7. Adjust the main relief CW while observing both gages stop turning when there is no change in the gage. 8. Repeat steps 5 and 6 until you arrive at desired P.S.I. 9. The main relief (PGP pressure) should have final setting about 200 P.S.I. higher than the spinner/auger relief (L.S. pressure). 8

DETAILED DESCRIPTION OF THE STAND ALONE SPREADER REFERENCE CIRCUIT SCHEMATIC FOR Pump Gage Port (PGP) Indicates the inlet pressure from the pump. This pressure will be approximately 300 PSI higher than the actual pressure at the motors due to the load-sensing operation of the valve network. Load Sense (LS) Indicates the pressure of the load (motor). If more than one function is operating concurrently then the higher load pressure is seen. There will only be a pressure from the LS port if a function is operating. The LS port can be used to adjust the spinner/auger relief. Remember, the PGP will display a pressure approximately 300 PSI higher than the pressure in the LS port while a function is operating. EV1 Pump bypass and pre-pressure compensation cartridge. EV1 is a normally closed -two position - two way -pilot cartridge. It can provide a very low pressure path for pump flow to escape to tank. This is its primary function when no functions are operating. The bypass pressure of the pump in this state will vary from about 20-60 PSI depending upon the pump flow. This pressure will show at PGP. The path to tank is opened by pump pressure being applied to the left side pilot of EV1 which forces it open. The right side pilot line of EV1 is drained to tank through SV1 (Unloader Solenoid Valve) to allow this to happen. Solenoid Valve (SV1) Unloader solenoid valve. SV1 is a normally open- two position - two way solenoid operated cartridge. When its solenoid is not energized it provides a drain path for the pilot pressure on the right side of EV1. This allows for pilot pressure on the left side of EV1 to push it open and expose a low pressure path for the pump flow to escape to tank. SV1 will energize whenever any function of the MESP 202H is operating. This closes the pilot drain on the right side of EV1 and that in-turn cause EV1 to begin shutting off the pump flow escape to tank. Pump flow is now forced to move toward motor valves as required. If SV1 was energized or manually overridden (if equipped) without any other system valves functioning, the pressure at PGP would be approximately 300 PSI. The L.S. port would not have pressure. 9

Check Valve (CV1) Boost pressure check valve. CV1 is a simple spring biased ball check cartridge. Its purpose is to raise the differential or boost pressure between PGP and LS by a margin of approximately 300 PSI. It comes into play when SV1 is energized. At that point the pilot pressure on the right side of EV1 can only drain through CV1. CV1 s internal bias spring is set for 270 PSI. That means the pressure of EV1 s pilots (both sides) must build to at least 270 PSI before the right side pilot can drain through CV1 and allow EV1 to begin to open. This boost pressure is required to allow flow to get through other cartridge valves in the system to operate functions. When CV1 has a load-sense pressure applied to its right side which is communicated from LS1 (Load Shuttle) this will add to the pressure required for EV1 to drain its right side pilot and open. For example, if the load-sense pressure for a spreader motor is 1000 PSI, this will be added to the (270 PSI) spring bias pressure of CV1. Now EV1 cannot begin to open its path to tank until the pump pressure has achieved something slightly higher than 1,270 PSI. PGP would display 1,270 + PSI and L.S. port would display 1000 PSI. In this way the system will always attempt to sustain a differential or boost pressure of approximately 300 PSI. Relief Valve (TS1) Main system relief valve. TS1 is an adjustable relief cartridge that is used in conjunction with EV1 to limit the maximum pump pressure. TS1 is located in the pilot path on the right side of EV1. It is preset from the factory at 2,200 PSI. This can be adjusted to a maximum of 3000 PSI. When TS1 opens it begins to drain the pilot on the right side of EV1 at whatever pressure TS1 has been set. The pressure of the pump and the left side of EV1 will build slightly higher and force EV1 to begin to open and provide a tank path for the pump. Orifice (ORF1) Load sense drain orifice. ORF1 provides a controlled drain for the load-sense pilot line/ev1 control pilot. Its function is to ensure that the pressure cannot be trapped in this pilot and result in EV1 not being able to fully open at low pressure when required. Proportional Valve (PV1) Spinner flow control valve. PV1 is a proportional solenoid flow control valve that also incorporates pressure compensation. In its unenergized state it provides a blocked path between the pump flow and the spinner work port. When it is energized it provides an increasing orifice opening to flow as a result of increasing electric current to its solenoid coil. Its range of flow control is 0-7 gallons-per-minute. A second internal stage of PV1 provides pressure compensation of the flow control. This stage will react to changes of pump pressure conditions relative to the spinner load pressure demands. If the pressure difference goes too high the compensator stage will squeeze down to prevent extra flow from shooting through the proportional valve orifice setting. The basis of stable flow control requires this feature. 10

Proportional Valve (PV2) Auger/Conveyor flow control valve. PV2 is a proportional solenoid flow control valve that also incorporates pressure compensation. In its non-energized state it provides a blocked path between the pump flow and the auger/conveyor work port. When it is energized it provides an increasing orifice opening to flow as a result of increasing electric current to its solenoid coil. Its range of flow control is 0-15 gallons-per-minute. A second internal stage of PV2 provides pressure compensation of the flow control. This stage will react to changes of pump pressure conditions relative to the auger/conveyor load pressure demands. If the pressure difference goes too high the compensator stage will squeeze down to prevent extra flow from shooting through the proportional valve orifice setting. The basis of stable flow control requires this feature. Relief Valve (RV1) Spreader pressure relief. RV1 limits the pressure of the spreader motor circuits. This gives independent protection to the motors from the rest of the system. Load Sense (LS1) Load shuttle cartridge. LS1 is similar to two check valves set back-to-back. Its purpose is to communicate the load pressure of the highest spreader motor pressure back to CV1. 11

Muncie Power Products, Inc. Member of the Interpump Hydraulics Group General Offices and Distribution Center P.O. Box 548 Muncie, IN 47308-0548 (765) 284-7721 FAX (765) 284-6991 E-mail info@munciepower.com Web site http://www.munciepower.com Drive Products, Exclusive Agents for Canada, ISO Certified by an Accredited Registrar IN09-05 Printed in the U.S.A. Muncie Power Products, Inc. 2009