Welding With Arc Welding Equipment

Similar documents
Safe Schools: A Health and Safety Check

Welding and Cutting With Oxygen-Fuel Gas

WELDING, CUTTING AND BRAZING

COMPANY HEALTH & SAFETY PROGRAM. Title: Welding & Cutting Section No: 45

Spray Finishing Self-Inspection Checklist

Dip Tanks Containing Flammable or Combustible Liquids Self-Inspection Checklist

Dip Tanks Self-Inspection Checklist

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Welding, Cutting, and Brazing

WELDING AND OTHER HOT WORK

Slings Steel Chain, Wire Rope and Metal Mesh

Risk Management Resources

DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

Slings Natural Rope, Synthetic Rope and Synthetic Web

Electrical Safety Work Practices

Definitions found in several locations:

OSHA Subpart I Tools - Hand & Power

Respiratory Protection Self Inspection Checklist

Ground Fault Circuit Interrupter(GFCI) Policy

Welding/Cutting/Brazing with Hot Work Permit

11/2/2017. Course Objectives. Overview

Check with local zoning official for property line distance requirements.

Management Plan for Electrical Safety ISD #535

CHAPTER 26 WELDING AND CUTTING

This training does not attempt to cover all safety regulations or precautions.

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

Welding & Cutting Written Program

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

HOT WORK SAFETY 29 CFR WELDING & CUTTING SAFETY (HOT WORK)

Tony Kuritz & Curtis Taylor INSafe Health & Safety Consultants A Safer Look at Welding

Gettysburg College. Energy Control Program

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Newsletter of Jointing, Welding & Cold-Formed Steel Group, HKISC UNDERWATER WELDING. Ir Dr Chan Wai Tai. Chairman of Welding Group, HKISC

PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT)

Bemidji Area Schools. Management Plan for Welding, Cutting and Brazing

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Hot Work Program. California State University, Chico. Department of Environmental Health and Safety

Bakery Flour-Handling equipment and ovens

Wilkins Safety Group

General Safety and Health Provisions for Construction Self Inspection Checklist

ES18 Security Theory/Regulations Answer Schedule

Electrical. OSHA Office of Training and Education 1

Underwater Wet Welding Products Operating Instructions

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

MECHANICAL POWER-TRANSMISSION APPARATUS SELF INSPECTION CHECKLIST

WARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS

KMU SUBSTATION WORKSHOP

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Hazardous Energy Control (Lockout-Tagout)

PERSONAL PROTECTIVE EQUIPMENT

OFFICE OF STATE HUMAN RESOURCES

Safety Powder Spray Systems

INTER PLANT STANDARD STEEL INDUSTRY

230-LOCKOUT/TAGOUT PROGRAM

Original Date of Issue: 04/09

Hot Work Safety Program and Procedures

Lockout / Tag out Program

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

A guide to Part 10 of the

Electrical Safety Program February 2, 2016

Welding Subpart Q

GAS FUEL VALVE FORM AGV5 OM 8-03

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Safety and Health Policy and Procedure Manual. WELDING, CUTTING, and BRAZING PROGRAM Section 0140

List all key terms and acronyms used in the procedure, and their definitions.

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

Servicing Multi-Piece and Single Piece Rim Wheels Self Inspection Checklist

Electrical Safety Program

WARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS

Lockout Tagout Policy

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Electrical Safety. Introduction

CHAPTER 28: HOTWORK (WELDING/OXYGEN-ACETYLENE GAS)

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

Provided by. Personal Protective Equipment. Workers Health & Safety Division HS96-101C (07-04)

SAFETY DIRECTIVE 2.0 DEPARTMENTS AFFECTED. This Administrative Directive shall apply to all Town of Marana departments and employees.

Selection of Electrical PPE Tables

2. The purpose of this program is to achieve the following objectives:

WELDING AND CUTTING GUIDELINES

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Lockout/Tagout - Energy Control Program

Page: 7/15/2009. Energy control procedures Use of lockout/tagout equipment to ensure safe work practices.

LO/TO LOCKOUT/TAGOUT PROGRAM

Compressed Gases and Cryogens

HAZARD COMMUNICATION SELF INSPECTION CHECKLIST

University of Vermont Department of Physical Plant Personal Protective Equipment Program

Electrical Safety Program

THE OSHA LOCK-OUT/TAG-OUT STANDARD

ARKANSAS TECH UNIVERSITY FACILITIES MANAGEMENT HEALTH AND SAFETY MANUAL (LOCKOUT/TAGOUT) 30.0

CERTIFICATION OF HAZARD ASSESSMENT AND PERSONAL PROTECTIVE EQUIPMENT SELECTION WORKSHEET

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard

HEALTH AND SAFETY MANUAL

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

University of Tennessee Safety Program

Transcription:

Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Welding With Arc Welding Equipment Self Inspection Checklist Guidelines: This checklist covers some of the regulations issued by the U.S. Department of Labor - OSHA under the General Industry standards 29 CFR 1910.254 & 1910.306 and the Construction standards 1926.351 & 1926.353. All of these regulations were adopted by reference. The checklist also covers regulations issued by the New Jersey Department of Community Affairs (NJDCA) under the Uniform Fire Code (N.J.A.C. 5:70-3.2). The Uniform Fire Code has adopted by reference the model code of the Building Officials and Code Administrators International, Inc. known as the BOCA National Fire Prevention Code/1996." It applies to the use of arc welding and cutting equipment. This checklist must be used in conjunction with the checklist "Welding, Cutting and Brazing- General requirements." Questions marked with the symbol ( ) may require the help of an outside expert. Any question marked with the symbol ( ) indicates a history of previous violations in vocational schools. General 1. Are students/employees properly instructed and qualified to operate arc-welding equipment? [29 CFR 1910.254(a)(3), 1926.351(d) and N.J.A.C. 5:70-3.2{BOCA F-2203.2}] Please Circle 427

Application of Arc-Welding Equipment 2. Does arc-welding equipment comply with the Requirements for Electric Arc-Welding Apparatus, NEMA EW-1-1962, National Electric Manufacturers Association or the Safety Standard for Transformer-Type Arc Welding Machines, ANSI C33-2-1956, Underwriters Laboratories? [29 CFR 1910.254(b)(1)] 3. Are arc-welding machines designed and constructed to operate under their anticipated environmental conditions including unusual altitude, temperature, corrosive chemicals, steam, humidity, oil vapors, flammable liquids, vibration/shock, dust or weather? [29 CFR 1910.254(b)(2)] 4. Are alternating-current manual arc-welding and cutting machine voltages limited to 80 volts? [29 CFR 1910.254(b)(3)(i)(A)] 5. Are alternating-current automatic arc-welding and cutting machine voltages limited to 100 volts? [29 CFR 1910.254(b)(3)(i)(B)] 6. Are manual or automatic direct-current (DC) arc-welding and cutting machine voltages limited to 100 volts? [29 CFR 1910.254(b)(3)(ii)(A)] 7. Are terminals for welding leads protected from accidental contact? [29 CFR 1910.254(b)(4)(iv)] 8. Are only manual electrode holders used specifically designed for arc welding and cutting? [29 CFR 1926.351(a)(1)] 428

9. Are manual electrode holders of a capacity capable of safely handling the maximum rated current required by the electrodes? [29 CFR 1926.351(a)(1)] 10. Are all current-carrying parts passing through the portion of the holder which the arc welder or cutter grips in his hand and the outer surfaces of the jaws of the holder fully insulated against the maximum voltage encountered to ground? [29 CFR 1926.351(a)(2)] 11. Are arc welding and cutting cables completely insulated, flexible and capable of handling the maximum current requirement of the work in progress? [29 CFR 1926.351(b)(1)] Installation of Arc-Welding Equipment 12. Are arc-welding machine frames or cases electrically grounded? [29 CFR 1910.254(c)(2)(i) and N.J.A.C. 5:70-3.2{BOCA F-2206.1}] 13. Are grounding circuits checked to ensure that the circuit between the ground and the grounded power conductor has resistance low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current? [29 CFR 1926.351(c)(f)] 14. Do ground return cables have a safe current carrying capacity equal to or exceeding the specified maximum output capacity of the arc welding or cutting unit which it services? [29 CFR 1926.351(c)(1)] 429

15. Are chains, wire ropes, cranes, hoists, elevators and conduits containing electrical conductors prohibited from being used to complete work-lead circuits? [29 CFR 1910.254(c)(2)(ii) & (iii) and 1926.351(c)(2)] 16. If pipes are temporarily used to complete work-lead circuits, are pipes free from threaded, flange bolted or caulked joints? [29 CFR 1910.254(c)(2)(ii)] 17. If a structure or pipeline is used as a ground return circuit, are periodic inspections performed to determine that the required electrical contact exists at all joints? [29 CFR 1926.351 )(3) and N.J.A.C. 5:70-3.2{BOCA F-2206.2}] Note: The generation of an arc, sparks, or heat at any point shall cause rejection of the structures as a ground circuit. If the structure or pipelines are used continuously, all joints should be bonded and periodic inspections conducted to ensure that no condition of electrolysis or fire hazard exists by virtue of such use. 18. Are all grounding connections checked to determine that they are mechanically strong and electrically adequate for the required current? [29 CFR 1910.254(c)(2)(v), 1926.351(c)(6) and N.J.A.C. 5:70-3.2{BOCA F-2206.1}] 19. Is a disconnecting switch with overcurrent protection located at or near each arc-welding machine which is not equipped with such a switch? [29 CFR 1910.254(c)(3)(i) and 29 CFR 1910.306(d)(1)] 430

20. Is a disconnecting switch with overcurrent protection provided for each outlet intended for connection to a portable welding machine? [29 CFR 1910.254(c)(3)(i)] 21. For individual welding machines, is the rated currentcarrying capacity of the supply conductors not less than the rated primary current of the welding machine? [29 CFR 1910.254(c)(3)(ii)] 22. Are all DC arc-welding machines connected with the same polarity? [29 CFR 1910.254(c)(3)(iv)(A)] 23. Are all AC arc-welding machines connected to the same phase of the supply circuit and with the same instantaneous polarity? [29 CFR 1910.254(c)(3)(iv)(B)] Operation and Maintenance 24. Are students/employees assigned to operate or maintain arc welding equipment acquainted with the requirements of 29 CFR 1910.252 and 1910.254? [29 CFR 1910.254(d)(1)] 25. Are students/employees engaged in gas-shielded arcwelding acquainted with Recommended Safe Practices for Gas-Shielded, Arc-Welding A6.1-1966, American Welding Society? [29 CFR 1910.254(d)(1)] 26. Are arc-welding machine hook-ups checked before starting operations? [29 CFR 1910.254(d)(2)] 27. Is coiled welding cable spread out before use to avoid serious overheating and damage to insulation? [29 CFR 1910.254(d)(2)] 431

28. Is the grounding of the welding machine frame checked before starting operations? [29 CFR 1910.254(d)(3)] 29. Are arc-welding machines checked for leaks of cooling water, shielding gas or engine fuel before starting operations? [29 CFR 1910.254(d)(4)] 30. Is it determined that proper switching equipment for shutting down the machine is provided? [29 CFR 1910.254(d)(5)] 31. Are the manufacturer's printed rules and instructions covering operation of the equipment supplied strictly followed? [29 CFR 1910.254(d)(6)] 32. When not in use for 1 hour or more, are electrodes removed from the holders, the holders safely placed so they cannot make contact with people, conductive objects, fuel or compressed gas tanks and the machines disconnected form the power source? [29 CFR 1910.254(d)(7), 1926.351(d)(1) & (d)(3) and N.J.A.C. 5:70-3.2{BOCA F-2206.3}] 33. Are electrode cables free from splices within 10 feet from holders? [29 CFR 1910.254(d)(8) and 1926.351(b)(1)] Note: The General Industry standard 1910.254(d)(9)(iii) and the Construction standard 1926.351(b)(1) permit joining lengths of cable by standard insulated connectors specifically designed for that purpose. The Construction standard, however, also permits splices which are insulated as well as the original cable. 432

34. Is the operator required to report any equipment defects or safety hazards to the teacher and to discontinue use until its safety has been assured? [29 CFR 1910.254(d)(9)(i) and 1926.351(d)(4)] 35. Are arc-welding machines repaired only by qualified personnel? [29 CFR 1910.254(d)(9)(i)] 36. If arc-welding machines become wet, are they thoroughly dried and tested before use? [29 CFR 1910.254(d)(9)(ii)] 37. Is dipping of hot electrode holders into water prohibited? [29 CFR 1926.351(d)(2)] 38. Are cables with damaged insulation or exposed bare conductors replaced? [29 CFR 1910.254(d)(9)(iii)] Note: The Construction standard 1926.351(b)(4) permits repair of cables with rubber and friction tape or other equivalent means as long as the areas are protected by sufficient insulation. 39. When metal-arc welding using inert gas, are chlorinated solvents kept at least 200 feet away or shielded from the exposed arc? [29 CFR 1926.353(d)] Note: Inert-gas metal-arc welding produces 5 to 30 times more ultra-violet radiation then shielded meta-arc welding. Extra precautions should be used to protect direct skin and eye exposure as well. 433

This page was left intentionally blank 434