ATEX installation and service instruction

Similar documents
Operating instruction

HEAVY DUTY KNIFE GATE VALVE

Declaration of Conformity as per Directive 97/23/EC

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Telefon (+45) Telefax (+45)

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Knife Gate Valves Pricelist 2017

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

DK46 - DK800 Supplementary instructions

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Translation assembly instructions with operating manual and technical appendix

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

6-5 Maintenance Manual

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Type BBS-03, BBS-05, BBS-06, BBS-25

CAST IRON SAFETY VALVE TYPE 6301

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

2-Port Seat Valves with Flange, PN 16

FLANGED TWO-PIECE BALL VALVES

VA FLOWMETERS Supplementary Instructions

2-Port Seat Valves with Flange, PN 16

Horizontal Bladder Tanks

II 2G EEx ia IIC T6. Ignition protection class

Vertical Bladder Tanks

Installation, operation & maintenance manual - original version

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

FLANGED TWO-PIECE BALL VALVES

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Magnetic level switch type MR783 Instruction Manual

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Declaration of Conformity as per Directive 97/23/EC

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

64 Series Pressure Reducing Regulators

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

M18W49_MME75_F_EN MANUAL

M18W49_MME100EX_F_EN MANUAL

RTD temperature probes

Proportional Relief Valves

627 Series Pressure Reducing Regulators

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Booster Regulator/Air Tank

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Declaration of Conformity as per Directive 97/23/EC

Temperature gauge Installation Guide

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

VG5 Supplementary instructions

M18W49_MME100_MUS_EN MANUAL

Safety Relief Valve HON 832

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

3-port seat valves with externally threaded connection, PN 16

Two-port seat valves

OPERATION MANUAL PNEUMATIC VALVES

ATEX and explosive atmospheres

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Pressure and Flow Control Valves DBGM, German and European Patents

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE. REF. DOC.MMM900N Rev.1 March 2014 SERIES M DIN / ANSI. Page 1 of 17

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

Instruction Manual Differential Pressure Transmitter

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: K

FLANGED MULTI-PORT BALL VALVES

Gas Pressure Regulator HON 502

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE FOR LCV BALL VALVES REF. DOC. MMM LCVE Rev.0 July 2010 SERIES SFF & SFR.

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

safety Shut-Off Valve HON 721

Gas Pressure Regulator HON 200

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

6301 TYPE CAST IRON SAFETY VALVES

Ball Valve with ball/stem unit and Richter ENVIPACK universal packing

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

OFFICINE OROBICHE S.p.A. 1/9

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Transcription:

ATEX installation and service instruction 2014/34/EU for Cat 1 Zone 20 Knife gate valves series XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV, D2G

ATEX installation and service instruction 2014/34/EU for Cat 1 Zone 20 Knife gate valves series XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV, D2G Content 1 Service destination... 2 1.1 General destination... 2 1.2 Service in - zone area... 2 2 Safety requirements... 2 2.1 General safety requirements... 2 2.2 Instruction to the user... 2 2.2.1 Specific conditions for safe use... 2 2.3 Safety requirements for use of the valve in -area... 4 2.3.1 Safety warnings at service and maintenance of the valve... 4 2.3.2 Hazards arising from surface overheating on valve body... 4 2.3.3 Inflammable medium in the valve: Hazards arising from leakage at the valve body... 4 2.3.4 Hazards arising from electrostatic charge and discharge... 5 2.3.5 at overload... 6 2.3.6 of dust deposits... 6 2.3.7 Instructions for use of the valve... 6 3 Complementary information... 7 1 Document: ex-valve-cat1, 2017-03-02, issue: 6

0 General The purpose of this instruction is to make installation, service and maintenance easy for the user of Stafsjö Knife Gate Valves in series XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV and D2G in -area. If these notes and warnings are not respected by the user, dangerous situations may occur and may invalidate the warranty of the manufacturer. The manufacturer will answer any questions. For addresses, see chapter 3. 1 Service destination 1.1 General destination Stafsjö valve types XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV and D2G are destined - after installation between flange(s) in a pipe system to shut off, to open or - in particular cases - control the flow within the admissible pressure/temperature limits. Further information on the valves; see Stafsjö Original Installation and Service Instruction Knife Gate Valves 1.2 Service in - zone area If Stafsjö valves types XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV and D2G are used in areas classified in accordance with Directive 1999/92/EG (ATEX 137): The safety warnings below must be imperatively followed The Stafsjö Original Installation and Service Instruction Knife Gate Valves must be followed to its full extent by the user. Can, if necessary, Stafsjö- document:< Assessment of risk of ignition XV, MV, MP, HG (HP), HL, HX, WB (WB11, 12, 14), RKO, JTV and D2G,> be consulted. A separate risk analysis must be done as well as corresponding precautions for the combination valve/actuator/solenoid valve (depending on what is present) and the (usually electric) control system. The analysis must at least correspond to demand described in the directive 1999/92/EG (ATEX 137) and DIN EN 13463, part 1 and 5 2 Safety requirements 2.1 General safety requirements For the valves the same safety regulations apply as for the pipe (system) and for the components in the control system necessary for actuation. This instruction includes only such safety warnings which are extra important to pay attention to in use of the valves in -areas. 2.2 Instruction to the user It is the user s responsibility to secure that the valve is being used according to the regulations in chapter 1. The knife gate valves in its total (valve, actuator, accessories) is only destined for use in dusty environments and cannot therefore be used in applications were inflammable gases do occur. The valve may not be changed in any way by the user. The manufacturer will not take any responsibility if the features of the valve have been changed. 2.2.1 Specific conditions for safe use The potentially explosive products handled should have the following safety parameters. The maximum permitted minimum ignition and smoulder temperatures depend directly on the conveying temperature TF of the products handled. 2 Document: ex-valve-cat1, 2017-03-02, issue: 6

It is always the component/material in the valve, with the lowest temperature that limits the temperature of the application. Seat Max. permitted conveying temperature TF Ignition temperature 3 /2* TF Smoulder temperature TF+ 75 C Min.- ignition energy EPDM MV, WB Nitrile MV, WB Viton (FKM Black) MV PTFE with O-ring nitrile* XV, MV, MP, HG, HP, HL, HX, RKO, D2G 120 C 180 C 195 C 100 C 150 C 175 C 180 C 270 C 255 C 100 C 150 C 175 C PTFE with O-ring viton (FKM black)* XV, MV, MP, HG, HP, HL, HX, RKO, D2G PTFE with O-ring EPDM* XV, MV, MP, HG, HP, HL, HX, RKO, D2G Metal with Grafoil MV, HG, RKO 180 C 270 C 255 C 120 C 180 C 195 C 300 C 450 C 375 C >1mj Polyurethane 90 C 135 C 165 C JTV * It is the material of the O-ring that limites the temperature. General temperature limits for body gaskets PTFE 260 C Grafoil 550 C Min. ignition energy According to SS EN 13821 Ignition temperature According to SS EN 50281-2-1 Smoulder temperature According to SS EN 50281-2-1 3 Document: ex-valve-cat1, 2017-03-02, issue: 6

2.3 Safety requirements for use of the valve in -area 2.3.1 Safety warnings at service and maintenance of the valve Advice The equipment may only be used in -areas as long as the safety requirements are followed and the valve is correctly installed. Installation and maintenance may not be done in -areas, this to avoid potentially explosions due to ignitable sparks caused by internal friction or external strain, such as stroke impact Wear parts must be regularly checked and immediately exchanged when worn out. 2.3.2 Hazards arising from surface overheating on valve body A high temperature on the conveyed material must not cause the surface temperature of the valve high enough to ingnite. The manufacturer Stafsjö cannot mark the valve with temperature class according to EN 13463-1:2009 table 1, but instead must provide this designation TX due to that the surface temperature of the valve depends directly on the service temperature of the products handled. Electrical motors shall not exceed a power over 4KW unless the valve size and travel speed so requires, special care shall be taken in consideration to avoid hot surfaces and ignition risk. The user shall make an ignition risk analysis. It is the user s responsibility to make sure to fulfill the regulations according to EN 13463-1:2009 chapter 6.2.5 and 6.2.7. 2.3.3 Inflammable medium in the valve: Hazards arising from leakage at the valve body If the valve is built in to a pipe system transporting an ignitable medium, could this at an eventually leakage from the valve end up in the surrounding environment. A leakage could also - if an ignition source exists nearby the valve become a hazard. In this type of application the user must perform maintenance on the valve periodically in accordance with Stafsjö Original Installation and Service Instruction Knife Gate Valve, in such a way that the valve, and, in particular glandbox packing (at the gate), as well as the bolting of the two valve bodie halves (when applicably) is inspected in respect of risk of leakage. The user must inspect the tightness when taking in service and thereafter establish monitoring periods and change of wear parts depending on the risk of ignition in the system. At gaseous medium with a temperature <50 C a suitable method of testing is to spray a foaming liquid all over the exterior of the valve. The manufacturer Stafsjö can on demand send a spare part kit for every valve. This kit includes all the usual wear parts. No substances which are sensitive to impact and friction based on their flammability or explosive properties, may be transported through the valve. Basically, the valve types are not suitably for transporting, shut off or regulate self-igniting materials. 4 Document: ex-valve-cat1, 2017-03-02, issue: 6

2.3.4 Hazards arising from electrostatic charge and discharge According to regulations, a metal valve must be fastend close on to metal pipework, wich leads to the valve conducting electricity. If the valve is not grounded through this connection (this is not likely), there is a potentially risk of ignition. The valve body must therefore be grounded separately according to SS- EN13463-1:2009 chapter 6.7.2. On the valve there is an earthing cable for this purpose. The user has to make sure that an istalled valve is correctly grounded and that the valves function throughout its useful life is ensured. Make sure that the speed of the moving gate is less than 1m/s, to avoid the risk of ignitable sparks caused by impact or friction. Because it is not possible to rule out electrical charge of the gate at high flow speed, valve designated for - use is equipped with a spring unit, i.e. from the factory. Caution! The installation must be checked at regular periods to verify that the spring has full function and that it so remains. By safety reasons must the spring be replaced after 10 000 strokes of the gate. For spare parts, contact the manufacturer. A valve where the spring is broken must under no circumstances be operated, since it can be a risk of ignition in the separation between the isolating gate and the handled medium, this because of electrostatic charging. The spring must be replaced immediately. Advice If the valve is equipped with pneumatic actuator, type Stafsjö AC, the cylinder pipe of the actuator must be connected to the top end cap by a contact spring, alternative mounted on a connecting coupling. This because the cylinder pipe is sealed with a gasket and therefore contact cannot be secured by certainty. At installation it must be ensured that this contact spring is replaced after changing the gaskets that the contact spring continuisly have contact with the metal wall on the cylinder pipe of the actuator Note! For valve intended for category 1, no aluminum is permitted! Make sure to select an actuator permitted for the corresponding category. 5 Document: ex-valve-cat1, 2017-03-02, issue: 6

The valve body is in most cases in cast iron or in cast steel and are delivered, if appropriate, with a conductive painting acc. ATEX (with max. surface resistance < 10^9 Ω) in order to fulfill corrosion class EN12944: C3 from the manufacturer. 2.3.5 at overload The valve are equipped with a stem/piston rod wich connection to the actuator/ the gate can breake at excessively overload. If this happens suddenly, there is a risk of ignition. Stafsjö eliminates this risk by a. specifying the maximum force for the actuator to what is stated in data sheet under pneumatic actuator. These values are valid regardless of type of actuator. Any deviation from these values has to be approved by Stafsjö. b. the valve in - execution are delivered with a stem in ductile material with ultimate elongation >20%. At overload the threads are deformed and will block. Warning! If such a situation should arise, all operating must immediately stop. Warning! Modification of the valve parts made by the user can pose a risk of ignition and is strictly prohibit 2.3.6 of dust deposits Dust deposits in the split between the gate and the box packing must periodically be brushed off. Avoid using compressed air because the dust that swirls up can cause a - atmosphere. The higher the operating temperature and the actuation frequency are and the greater the dust deposist are, the more frequently must the valve be cleaned. The dust deposists thickness may not be more than 5mm to avoid underpass safety distance to the filament temperature as described in paragraph 2.2.1. 2.3.7 Instructions for use of the valve Valves, covered by the Atex directive, must when placed in - environments be marked accordingly Atex 2014/34/EU by the manufacturer. Ser.No: Serial number consisting of year individual no - order number. CE-marking. 1) Beside the marking, the number of the responsible notified body, who have been involved in the product verification, must be indicated. The marking may possibly already have been made on the valve, as it satisfies the Pressure Equipment Directive (PED). 6 Document: ex-valve-cat1, 2017-03-02, issue: 6

3 Complementary information This instruction, the mentioned Stafsjö brochures and other information and detailes can be found on www.stafsjo.com. The material can also be ordered from following address: Stafsjö Valves AB Störningsväg SE-618 95 Stavsjö +46 (0)11 39 31 00 Fax +46 (0)11 39 30 67 www.stafsjo.com info@stafsjo.se 7 Document: ex-valve-cat1, 2017-03-02, issue: 6

Declaration of conformity with EU-Directives ATEX, cat. 1 Within the meaning of the European directive 2014/34/EU, issued on February 26th 2014 and its current legal version, as well as for its implementation enacted legal regulations, the manufacturer declares, that the products Type: Series: Knife Gate Valves XV, MV, HG, HL, (HP), HX, WB (WB, WB11, WB12, WB14), RKO, JTV, D2G Based on European directive 2014/34/EU and its harmonized European Standards SS EN 13463 Nonelectrical equipment for use in potentially explosive atmospheres 13463-1:2009, Part 1: Basic method and requirements 13463-5:2011, Part 5: Protection by constructional safety c Were tested by performing a conformity assessment procedure with the following result: The knife gate valves can be used in EX- areas according to 2014/34/EU, group II, category 1D, provided that the valve is labeled and equipped accordingly. This is in accordance with European directive 1999/92/EC 1/1 D (and also 1/2D and 1/3D) Category 1 is fulfilled through a type examination test at Notified Body DEKRA EXAM GmbH No 0158, with its number BVS 15 ATEX H 031 X The knife gate valves are labeled according: For 1D 1) II 1D 4) c 2) TX 3) -20 C T a +60 C 1) stamp is followed by the number by the no. of the notified body. 2) The marking "c" is the symbol for the ignition protection class "constructional safety" according to EN 13463-5:2011, chapter 1) 3) Footnote "TX": As the outer temperature is not dependent on the actual product, but only on the operating conditions (the temperature of the medium in the pipeline), the manufacturer are not allowed to mark a temperature class (T1 to T6), acc. to SS EN 13463-1, section 6.2.5, chart 3 4) The category identification of the delivered valves is in accordance to the purchase order. When operating, only dust or gas may be present, the use in hybrid mixtures is not permitted. This manufacturer certification is valid for the above mentioned type and series. Other configurations, in particular as an assembly with an actuator, requires a separate ATEX certification of the actuator according to the European directive 2014/34/EU Pneumatic actuator according to SS EN 13463-1 Electrical actuator according to SS EN 6079-0 Stafsjö, July 2018 Maria Persson, General Manager Stafsjö Valves AB Phone: 011 39 31 00 info@stafsjo.se A Bröer Group company SE-618 95 Stavsjö, Sweden Fax: 011 39 30 67 www.stafsjo.com

Stafsjö Valves AB SE-618 95 Stavsjö Sweden Tel: +46 11 39 31 00 Fax: +46 11 39 30 67 info@stafsjo.se www.stafsjo.com