FlowSol B / B HE * * Manual for the specialised craftsman. Installation Operation Commissioning

Similar documents
Installation and commissioning instructions 255 series and 256 series

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

Installation and Commissioning Manual Solar Stations FlowCon FA Evolution II

Solar Technology. Advantages. Everything from a single source Compact and modern design Customized models on request

Two-stage valve type NE

553 Series.

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

MANUAL. Sesame. Thermoplastic Tank Technologies

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

VIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Installation and Operating Instructions Bypass Flow Meter DST

Flamco Flamco-Fill STA Flamco-Fill STM

Operating and maintenance manual Filter and reducing station Series / 1.0

Siphon vessel / Priming aid

Operating manual for Material pressure tanks Vol./1 and Vol./2

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

GM-7000 Series CE Approved Gas Control Valve

System Pressure Manager Standard & System Pressure Manager Plus

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10

Flowmeter. Original operating manual DFM

Electronic Single and Twin Pump System Pressure Managers

Two-port valves, male threaded, PN25

Type BBS-03, BBS-05, BBS-06, BBS-25

2-port seat valves PN25 with externally threaded connections

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Overview of types. Technical data. Safety notes

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

VIESMANN. Service instructions VITOSOL-F. for contractors. Vitosol-F. For applicability, see the last page GB 3/2009 Please keep safe.

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Scald Protection Three-Way Thermostatic Mixing Valve

OPERATING INSTRUCTIONS

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Pressure Limiting Valve SPVF Operating Instructions

BOSS PULISCI PROVA IMPIANTI MEDIA

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

80 Litre Suction Oil Drainer

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Installation and Maintenance Instruction Manual

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

DECLARATION OF INCORPORATION

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Operating instructions - Translation of the original -

Pressure-controlled shut-off valve type CNE

PRAHER PLC-MP AQUASTAR MANAUL 2009

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

SCA Series Inverted Bucket Steam Traps

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure relief valve

64 Series Pressure Reducing Regulators

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Safety and operating instructions

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

OWNER S TECHNICAL MANUAL

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Experiment Instructions. Circulating Pumps Training Panel

INSTALLATION & MAINTENANCE INSTRUCTION

Pressure maintenance valve SDV-P / SDV-P-E

Direct Operated Precision Regulator Modular Style. Standard Specifications

Instructions for SILEX 1C Mixed bed cartridge filter

ATS430 turbidity sensor Retractable insertion assembly

Products no longer available

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Overview of types. Technical data

Propane Conversion Kit Instruction

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Transcription:

FlowSol B / B HE Manual for the specialised craftsman Installation Operation Commissioning *80060* 80060 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this unit. Please keep this manual carefully. Manual www.resol.com

Safety advice Please pay atttion to the following safety advice in order to avoid danger and damage to people and property. Instructions Atttion must be paid to the valid local standards, regulations and directives! Information about the product Proper usage The pump station may only be used in the solar circuit of solar thermal systems in compliance with the technical data specified in these instructions. Due to its design the station must be mounted and operated as described in these instructions! CE-Declaration of conformity The product complies with the relevant directives and is therefore labelled with the CE mark. The Declaration of Conformity is available upon request, please contact RESOL. Target group These instructions are exclusively addressed to authorised skilled personnel. Only qualified electricians should carry out electrical works. Initial installation must be effected by qualified personnel named by the manufacturer. Description of symbols WARNING! Warnings are indicated with a warning triangle! They contain information on how to avoid the danger described. Signal words describe the danger that may occur, wh it is not avoided. WARNING means that injury, possibly life-threating injury, can occur. ATTENTION means that damage to the appliance can occur. Note Notes are indicated with an information symbol. Arrows indicate instruction steps that should be carried out. Disposal Dispose of the packaging in an vironmtally sound manner. Dispose of old appliances in an vironmtally sound manner. Upon request we will take back your old appliances bought from us and guarantee an vironmtally sound disposal of the devices. Contts 1 Overview... Mounting the station... Flushing and filling the solar system... Ball valve positions... Draining the system... 6 Non-return valves... Flowmeter... 6 8 Air separator... 6 9 Maintance... 6 10 Safety devices... 6 11 Accessories... 1 Information about the pump... 1 Lists of spare parts... 1 Overview Pre-assembled twin-line pump station Integrated controller of choice from the DeltaSol BS, DeltaSol C, DeltaSol CS Plus or DeltaSol BX series Safety assembly with connection for the diaphragm-type expansion vessel, safety valve and pressure gauge Fill and drain valves Wall mounting bracket and mounting material Design insulation Standard or high-efficicy pump Ball valves in flow and return Air separator Subject to technical change. Errors excepted. 01091_80060_FlowSol_B.mon.indd

FlowSol B / B HE Pump characteristics / pressure loss characteristics Technical data Circulating pump: Wilo Star ST 1/6 ECO or 1/ ECO Wilo Stratos TEC 1/6 or 1/1-; Wilo Yonos Para ST 1/ (HE pumps) Safety valve: 6 bar Pressure gauge: 0... 10 bar Flowmeter: 1... 1 l/min Non-return valves: Oping pressure 0 mbar, opable Connection to diaphragm-type expansion vessel: ¾'' ET, flat sealing Outlet safety valve: ¾'' IT Delivery height (m) 8 6 1 FlowSol B standard pumps FlowSol B Wilo ST 1/ ECO max. Wilo ST 1/6 ECO max. 0,8 0, 0,6 0, 0, 0, 0, 0,1 Pressure loss (bar) Connections to the solar pipes: ¾'' IT Maximum temperature flow / return: 10 C / 9 C 0 0,0 0 10 1 0 0 0 Flow rate (l/min) Maximum pressure: 6 bar Medium: Water with max. 0 % glycol Dimsions: Approx. 81 0 190 mm (with insulation) Distance ctres: 100 mm Distance ctre / wall: 6 mm Material: Fittings: brass Seals: AFM Insulation: EPP foam Delivery height (m) 8 6 FlowSol B HE high-efficicy pumps Wilo Stratos TEC 1/ max. Wilo Yonos Para ST 1/ max. Wilo Stratos TEC 1/6 max. FlowSol B 0,8 0, 0,6 0, 0, 0, Pressure loss (bar) 0, Wilo Stratos TEC 1/ min. 1 0,1 Wilo Stratos TEC 1/6 min. Wilo Yonos Para ST 1/ min. 0 0,0 0 10 1 0 0 0 Flow rate (l/min)

Mounting the station 10 11 Note All connections are already tighted such that they usually do not have to be tighted again. However, during commissioning of the system all connections have to be checked for leaks (pressure test). 8 1 9 6 1 1 10 Wall mounting bracket 11 Back half of the insulation 1 Front half of the insulation 1 Hinged controller panel Controller and controller panel depd on the version of the station Î Determine the mounting site of the station. Î Mark the drill holes by means of the template closed, th drill and insert wall plugs (see fi gure to the right). Î Take the station out of the packaging. Î Remove the front half of the insulation. Leave the pump station attached to the back half of the insulation! Î Fast the pump station to the wall with the closed screws. For this purpose, use a crosshead screw driver. Î Fold the hinged controller panel to the left. Î Connect the pipework betwe pump station and store and collector respectively. Flushing and filling the solar system WARNING! Scald danger! Pressure surge damage! If the medium ters strongly heated, empty collectors, pressure surges caused by evaporation can occur. Î In order to prevt the solar fluid from vaporising inside the collectors, do not fill or flush the system during times of strong irradiation! 1 Safety valve Pressure gauge Drain valve Ball valve (return) with thermometer and integrated non-return valve Fill valve 6 Pump Flowmeter 8 Ball valve (flow) with thermometer and integrated non-return valve 9 Air separator

Before flushing the system Disconnect the expansion vessel from the solar thermal system. After flushing the system Connect the expansion vessel to the solar thermal system Close the drain valve () of the pump station while the filling pump is running. BAR Ball valve positions Non-return valve in operating position, fluid flow in flow direction only Ball valve op, fluid flow in both directions possible Ball valve closed, no fluid flow Connect the pressure hose of the filling and flushing station to the fill valve () of the pump station. Connect the flushing hose of the filling and flushing station to the drain valve () of the pump station. Close the ball valve of the pump station (). Op the fill valve () and the drain valve (). Switch on the filling pump of the filling and flushing station. Flush the solar thermal system for at least 1 minutes by means of the filling and flushing station until the discharged solar fluid is free of gas bubbles and dirt particles. During flushing, bleed the solar thermal system several times until the discharged solar fluid (e. g. Tyfocor, see chap. 11) is free of air bubbles. Op the ball valve of the pump station (). Increase system pressure (approx.. - bar). The system pressure can be read from the pressure gauge. Close the fill valve (). Switch off the filling pump. Check the pressure gauge to see whether the system pressure reduces and eliminate leaks where necessary. Slowly discharge the heat transfer fluid by means of the drain valve () until the operating pressure is set. Remove the hoses of the filling and flushing station and screw the caps onto the fill and drain valves. Manually start the solar thermal pump at maximum speed (see controller manual) and let the fluid circulate for at least 1 minutes. Bleed the solar thermal system several times. Check the system pressure at the pressure gauge. % Draining the system Op the ball valve (). Op the air vt at the highest point of the system (above the collectors). Op the drain valve. 6 Non-return valves The non-return valves of the pump station are integrated into the ball valves in flow and return and have an oping pressure of 0 mbar. In order to completely drain the system, the nonreturn valves have to be oped. For this purpose, turn the handles of the ball valves by. For normal system operation, op the ball valves completely. Check the antifreeze ratio (not required if a ready mix is used).

Flowmeter The flowmeter measures and indicates the flow rate with a range of 1-10 l/min. For the device to function faultlessly, the system must be flushed and free of grit. Read the flow rate from the upper edge of the float 8 Air separator WARNING! Scald danger! During vting, the air discharged can reach temperatures of more than 100 C. The air separator is used for vting the water / glycol mixture in the solar circuit. The air separated from the heat transfer fluid gathers in the air scoop and can be discharged manually at the air vt valve. Op the air vt valve and collect the discharged fluid in a suitable container. Check the system pressure after bleeding and, if necessary, increase it to the specified operating pressure. 9 Maintance In the case of maintance (such as a replacemt of the pump) proceed as follows: Close the ball valve (). Turn the slot of the flowmeter spindle by 90 anti-clockwise (see figure below). The heat transfer fluid can now be drained from the pump. Op the drain valve (). If necessary, op the union nut at the pressure side. Now dismount the pump. 10 Safety devices The pump station is equipped with a diaphragm safety valve which corresponds to the relevant directives and regulations. For installation and operation, please pay atttion to the following advice: The safety valve has to be easily accessible. The efficicy of the valve must not be influced or disabled by barriers! The strainer or other restriction devices must not be mounted betwe collector (-field) and safety valve! The diameter of the discharge pipe must correspond to the diameter of the valve outlet; the maximum lgth must not exceed m; more than bds are inadmissible. Wh these values are exceeded, you have to install a discharge pipe with larger dimsions. Do not use more than bds and pipes longer than m! If the discharge pipe leads into a drain pipe with a funnel, the diameter of the drain pipe has to be at least twice as large as the valve inlet. The oping of the discharge pipe must be inclined downwards. It must be routed such that the oping can be se but does not prest any risk to a person standing or passing by. We recommd placing a container below the discharge pipe. If the safety valve ops, the fluid will be collected and can be refilled into the system wh the pressure is too low. 6

11 Accessories 1 Lists of spare parts 10 11 1 8 1a,b Heat transfer and cleaning fluids In our product portfolio, you will fi nd a range of heat transfer fl uids for differt applications, available as readymix or conctrate, as well as cleaning fluids. 6a-d 1 SBS 000 filling and flushing station The SBS 000 has be especially designed for professionally fi lling and fl ushing solar thermal and heating systems. Its many thought-out details facilitate transport, operation and cleaning, the attractive design makes it the ideal companion for a professional performance. Article no: 80 010 9 Wall mounting for diaphragm-type expansion vessel Wall mounting for diaphragm-type expansion vessel with screws and wall plugs, high grade steel corrugated tube and connection thread ¾". Including quick release valve coupling abling removal of expansion without draining down of the system. Article no: 80 00 60 Filling and injection pump Filling and injection pump with non-return valve for pressure increase and refi lling of heat transfer fl uids. ½" OT self-sealing with O-ring, 1mm tube connection. Pump output l/min,. bar max. Article no: 80 00 0 ALS1 discharge hose 1. m hose for connection to the safety valve of the FlowSol B pump station. Article no: 80 00 9 See our full range of accessories on our website: www.resol.com 1 Information about the pump Depding on the version, the station is equipped with differt pumps. Data concerning the pump in your station are available at the pump manufacturer under www.wilointec.com. Upon request we will provide you with further information. Pos. Art. no. Article 1 11000 Safety valve 6 bar 110009 Pressure gauge 110008 Fill / Drain valve 1100069 Ball valve (return) with thermometer and integrated non-return valve 110008 Fill / Drain valve 6a 8000099 Pump WILO ST1/6 6b or 8000109 Pump WILO ST1/ 6c or Pump WILO Stratos TEC 1/6 6001 (HE pump) 6d or Pump WILO Stratos TEC 1/ 110116 (HE pump) 6e or Pump WILO Yonos Para ST 1/ 11019 (HE pump) 800090 Flowmeter 8 110006 Ball valve (fl ow) with thermometer and integrated non-return valve 9 800091 Air separator (not shown) 10 110001 Wall mounting bracket 11 00011 Back half of the insulation 1a 000161 Front half of the insulation DeltaSol BX 1b or Front half of the insulation DeltaSol 000161 B / C / CS Plus (not shown) 1 000161 Hinged controller panel

Distributed by: RESOL Elektronische Regelung GmbH Heiskampstraße 10 Hatting / Germany Tel.: +9 (0) / 968-0 Fax: +9 (0) / 968 - www.resol.com info@resol.com Important note The texts and drawings in this manual are correct to the best of our knowledge. As faults can never be excluded, please note: Your own calculations and plans, under consideration of the currt standards and directions should only be basis for your projects. We do not offer a guarantee for the completess of the drawings and texts of this manual - they only represt some examples. They can only be used at your own risk. No liability is assumed for incorrect, incomplete or false information and / or the resulting damages. Note The design and the specifications can be changed without notice. The illustrations may differ from the original product. Imprint This mounting- and operation manual including all parts is copyrighted. Another use outside the copyright requires the approval of RESOL Elektronische Regelung GmbH. This especially applies for copies, translations, micro films and the storage into electronic systems. Editor: RESOL Elektronische Regelung GmbH