200602q PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES

Similar documents
PULMONARY EFFECTS OF EIGHT-HOUR MK16 MOD I DIVES

EVALUATION OF INTRAVENOUS THERAPY DEVICES IN THE HYPERBARIC CHAMBER

NN- NAVY EXPERIMENTAL DIVING UNIT SECNIALRPOR NO. 6-9 NAV EPEIMETAL DI VING UIT~ TIC-99 DTIC QUAJLIXDISPECTED X

POTENTIAL BENEFITS OF NAVY DIVE COMPUTER USE IN SHIPS HUSBANDRY DIVING: ANALYSIS OF DIVES CONDUCTED ON THE USS RONALD REAGAN (CVN-76)

Introduction. U.S. Navy Diving Manual (Mar-1970)

PULMONARY OXYGEN TOXICITY WITH EXERCISE: SINGLE MK 25 REBREATHER DIVES OR SPLIT 6-HOUR EXPO~SURES

Cumulative effects of repeated exposure to po 2 = 200 kpa (2 atm)

ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES

Pulmonary effects of submerged oxygen breathing: 4-, 6-, and 8-hour dives at 140 kpa

EVALUATION OF THE KMS 48 FULL FACE MASK WITH THE VIPER VERY SHALLOW WATER UNDERWATER BREATHING APPARATUS

D TIC 0 F U AD-A IllllllIII ELECTE f1 JUN2 71M4 DEPARTMENT OF THE NAVY

AD-A DIVING UNIT NAVY EXPERI:MENTAL ...DTIC ILKICT[ 000 CTL14 Ift,

ELEDT S APR24 19 DECOMPRESSION SICKNESS AFFECTING THE TEMPOROMANDIBULAR JOINT. Author:

DTIC 1111II IGI~ ~I HI II17 04 AD-A NAVY EXPERIMENTAL DIVING UNIT REPORT NO OMMERCIALLY AVAILABLE IDI SCUBA REGULATORE

AVExPERIMENTAL DVING UNIT

NAVY EXPERIMENTAL DIVING UNITC OTIC_

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

UNMANNED TEST AND EVALUATION OF THE TELEDYNE ANALYTICAL INSTRUMENTS R-10DN OXYGEN SENSOR FOR USE IN THE MK 16 MOD 1 UNDERWATER BREATHING APPARATUS

OXYGEN-ACCELERATED DECOMPRESSION OF SUBMARINE RESCUE AND DIVING RECOMPRESSION SYSTEM (SRDRS) OPERATORS AND TENDERS

EVALUATION OF THE KMS 48 FULL FACE MASK CONFIGURED FOR OPEN CIRCUIT UBA WITH CROSSOVER TO EITHER MK 16 MOD 0 UBA OR MK 25 UBA

CHAPTER 9 $LU'HFRPSUHVVLRQ

AD-A Ott, pp, ELECTE NAVY EXPERIMENTAL DIVING UNIT

S... q. Psychometric Evaluation of the Mindstreams Neuropsychological Screening Tool. Navy Experimental Diving Unit

VVal-79 Maximum Permissible Tissue Tension Table for Thalmann Algorithm Support of Air Diving

. Vann, Ph.D. P.B. Bennett, Ph.D., D.Sz. ,frice o, Naval Research Contract N C-01.O; February 13, S",i., i " ;, c,,a ppzoved

Cognitive effects of hypercapnia on immersed working divers

XVAL-HE-4B: A MAXIMUM PERMISSIBLE TISSUE TENSION TABLE FOR REAL-TIME THALMANN ALGORITHM SUPPORT OF CONSTANT 1.3 ATM PO 2 -IN-HELIUM DIVING TO 200 FSW

Unit 3: The Physiology of Diving and Nitrox

Challenges in Undersea Medicine

INCIDENCE OF CNS OXYGEN TOXICITY WITH MILD HYPEROXIA: A LITERATURE AND DATA REVIEW

Design Of Semi-Closed Rebreathers To Minimize Variations In Circuit Oxygen Levels

SPUMS Journal Vol 27 No. 1 March

1 out of every 5,555 of drivers dies in car accidents 1 out of every 7692 pregnant women die from complications 1 out of every 116,666 skydives ended

GRAPHICAL ANALYSIS: DECOMPRESSION TABLES AND DIVE-OUTCOME DATA

D ivers are exposed to several factors that have effects on

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

ACCELERATED DECOMPRESSION USING OXYGEN FOR SUBMARINE RESCUE - SUMMARY REPORT AND OPERATIONAL GUIDANCE

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

EXECUTIVE SUMMARY USN DIVE MANUAL REVISION 7 Change A

Part 1: Inspiratory and expiratory pressures

20. TDI Advanced Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

20. Semi-Closed Circuit Rebreather Instructor, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

SCUBA - self contained underwater breathing apparatus. 5 million sport scuba divers in U.S. 250, ,000 new certifications annually in U.S.

Diving Medicine USN Diver/SEAL Submarine Overview / Tom Kersch, CAPT, MC!!

Temporary Flying Restrictions Due to Exogenous Factors

Chapter 53: Clinical Center Single-Breath Carbon Monoxide Diffusing Capacity (DLCO) MOP 53.1 Introduction

Spring 1999 Hyperbaric Medicine Newsletter. Fellows Presentations. Saturation Diving

Influence of Very High Breathing Resistance on Exercise Tolerance, Part 1 Dry Exercise

19. TDI Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

NOBENDEM. Advanced Decompression Tables

AFRL-RH-WP-TR

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Human Respiration Laboratory Experiment By

Lung Volumes and Capacities

11. TDI Semi-Closed Circuit Rebreather Diver Course, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Home ( Articles ( Oxygen Toxicity and CCR/Rebreather Diving

Syllabus Number: 3.B.35 / BOD n. 188 ( ) CMAS CCR Diver diluent air/nitrox Training Program Minimum Training Program Content

Naval Submarine Medical Research Laboratory

PULMONARY FUNCTION TESTING CORE

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

Submarine Base, Groton, Conn.

US NAVY DIVING PROGRAM: DIVING TO 300 FT DEPTHS USING SURFACE-SUPPLIED AND SATURATION FLY-AWAY DIVING SYSTEMS. Introduction

The impact of freediving on psychomotor performance and blood catecholamine concentration

SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 855

CLOSED-CIRCUIT OXYGEN diving is common. CNS Oxygen Toxicity in Closed-Circuit Diving: Signs and Symptoms Before Loss of Consciousness RESEARCH ARTICLE

Lung Squeeze: Coughing your lungs out...or not!

Decompression Sickness

Respiration Lab Instructions

Defense Technical Information Center Compilation Part Notice

RESA Standards V1.0 16/08/18

Medical Aspects of Diving in the Offshore Oil Industry

RESA STANDARDS V2.0 15/12/2018

UHMS/NOAA DIVING PHYSICIANS COURSE US NAVY NO-DECOMPRESSION TABLES REVIEW

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

:Q WfiEi~RW DIVING UNIT~

Defense Technical Information Center Compilation Part Notice

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

8. TDI Trimix Diver Course

Cornell Institute for. Biology Teachers. Respirometry Part I: Lung Volumes and Capacities. Lab issue/rev. date: 12/12/96. Title:

Imaging the Lung Under Pressure

29. Air Diluent Closed Circuit Rebreather Diver, Unit Specific

EasyWarePro Message Numbers

EasyWarePro Message Numbers

IATA Guidance for airline health and safety staff on the medical response to Cabin Air Quality Events

Instruction Guide for using Dive Tables (draft)

HYPERBARIC INTERVENTION IN SUBMARINE RESCUE SUT June 8 th Doug Austin Director, Asia Pacific

z Interim Report for May 2004 to October 2005 Aircrew Performance and Protection Branch Wright-Patterson AFB, OH AFRL-HE-WP-TP

CHAPTER 13 0L[HG*DV2SHUDWLRQDO3ODQQLQJ

Defense Technical Information Center Compilation Part Notice

CARBON MONOXIDE POISONING

Hypoxia Following Rapid Decompression to 18,288 m (60,000 ft) Attributable to Alveolar Hypoventilation

17. TDI Air Diluent Closed Circuit Rebreather Diver Course, Unit Specific- Inspiration / Evolution, KISS, Optima, Megalodon

9. Extended Range Instructor

MATHEMATICAL EVALUATION OF MULTI-LEVEL DIVING

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

SECOND EUROPEAN CONSENSUS CONFERENCE ON HYPERBARIC MEDICINE THE TREATMENT OF DECOMPRESSION ACCIDENTS IN RECREATIONAL DIVING

Respiratory System Lab

'40. j 1.8. IIJI25 11= L.6l MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU OF STANDARDS 1963 A

Transcription:

Navy Experimental Diving Unit TA 01-10 321 Bullfinch Rd. NEDU TR 05-05 Panama City, FL 32407-7015 April 2005 PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES Navy Experimental Diving Unit 200602q13 109 Author: B. E. Shykoff, Ph.D. Distribution Statement A: Approved for public release; distribution is unlimited.

UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE REPORT DOCUMENTATION PAGE l a. REPORT SECURITY CLASSIFICATION Unclassified 1b. RESTRICTIVE MARKINGS 2a. SECURITY CLASSIFICATION AUTHORITY 3. DISTRIBUTION/AVAILABILITY OF REPORT DISTRIBUTION STATEMENT A: Approved for public release; distribution 2b. DECLASSIFICATION/DOWNGRADING AUTHORITY is unlimited. 4. PERFORMING ORGANIZATION REPORT NUMBER(S) 5. MONITORING ORGANIZATION REPORT NUMBER(S) NEDU Technical Report No.05-05 6a. NAME OF PERFORMING 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION ORGANIZATION (If Applicable) Navy Experimental Diving Unit 6c. ADDRESS (City, State, and ZIP Code) 7b. ADDRESS (City, State, and Zip Code) 321 Bullfinch Road, Panama City, FL 32407-7015 8a. NAME OF FUNDING SPONSORING 8b. OFFICE SYMBOL 9. PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (If Applicable) Naval Sea Systems Command 00C 8c. ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS 2531 Jefferson Davis Highway, Arlington, VA 22242-5160 PROGRAM PROJECT NO. TASK NO. WORK UNIT ELEMENT NO.01A ACCESSION NO. A 01-10 11. TITLE (Include Security Classification) (U) PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES 12. PERSONAL AUTHOR(S) B. E. Shykoff, Ph.D. 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) 15. PAGE COUNT Technical Report FROM 2001 TO 2005 April 05 12 16. SUPPLEMENTARY NOTATION 17. COSATI CODES 18. SUBJECT TERMS (Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP Pulmonary oxygen toxicity, oxygen accelerated decompression, vital capacity, FEVI, diffusing capacity, hyperoxia 19. ABSTRACT (Continue on reverse if necessary and identify by block number) To remove personnel from a disabled submarine, rescuers will dive repeatedly with long bottom times and may use oxygenaccelerated decompression. We assessed pulmonary safety after repeated dives using proposed accelerated decompression schedules for 30, 40, or 60 feet of seawater with bottom times of 180, 240, or 360 minutes. Pulmonary function was evaluated within one hour of surfacing from the second dive ("immediate"), and two to four days after the dives ("delayed"). Of 115 divers, 26 had immediate low FEV 1 and 11 had immediate low FVC, but only four showed delayed low FEV 1, and none had delayed low FVC or DLCO. All changes resolved within one week. Immediate deficits were approximately proportional to oxygen exposure, though with a wide range of magnitude, while delayed changes appeared unrelated to dose. These oxygen exposures caused pulmonary stress with acceptable risk of short-term pulmonary function deficit and no evidence of long-term changes. 20. DISTRIBUTION/AVAILABILITY OF ABSTRACT 21. ABSTRACT SECURITY CLASSIFICATION UNCLASSIFIED/UNLIMITED SAME AS RPT. DTIC USERS Unclassified 22a. NAME OF RESPONSIBLE INDIVIDUAL 22b. TELEPHONE (Include Area Code) 22c. OFFICE SYMBOL NEDU Librarian 850-230-3100 DD Form 1473 UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE

CONTENTS Page No. DD Form 1473... I Table of Contents...... ii Introduction.... 1 M ethods..... 1 R esults....... 4 Discussion and Conclusions... 8 References... 9 FIGURES Figure 1: Pulmonary symptoms as a function of UPTD... 5 Figure 2: Forced vital capacity changes... 6 Figure 3: FEV 1 changes... 6 Figure 4: Peak expiratory flow changes... 7 Figure 5: Mid expiratory flow changes... 7 Figure 6: Diffusing capacity changes... 8 TABLES Table 1: Dive profiles for disabled submarine rescue simulation... 2 Table 2: Oxygen exposures (UPTD) for decompression... 2 Table 3: Symptoms list... 3

INTRODUCTION The Submarine Rescue and Diving Recompression System (SRDRS), the future disabled submarine rescue capability for the U.S. Navy, will include a module capable of transporting up to 16 submariners and two operators, and a surface chamber able to accommodate up to 36 people. A total of 10 dives would be required to rescue a 155-man crew. Oxygen-accelerated decompression as part of a repeated-dive profile could permit 10 operators to rescue a fully-manned submarine. Even emergency-use decompression schedules must keep the overall incidence of DCS within acceptable limits without imposing unacceptably severe symptoms or signs of pulmonary or CNS oxygen toxicity. NEDU was tasked to develop and test oxygen-accelerated decompression schedules for repetitive sub-saturation air sorties. 1 Eight oxygen-accelerated decompression profiles for tenders in a disabled submarine rescue vehicle were tested. Each profile involved two dives of the same duration to the same depth. NEDU Technical Report 05-042 describes the development and testing of the decompression profiles, while this report details the oxygen toxicity observed during testing of the profiles. GENERAL METHODS Fifty-seven divers completed 125 pairs of dives in the Ocean Simulation Facility (OSF) at Navy Experimental Diving Unit (NEDU), Panama City, FL. Each dive profile consisted of two dives of identical bottom time in the dry chamber separated by a surface interval of similar duration outside of the chamber. Divers breathed air during compression and on the bottom, but breathed 90-100% oxygen during most of decompression. Bottom times were 3, 4, or 6 hours at depths of 30, 40, or 60 feet of sea water (fsw). To simulate a rescue operation somewhat more closely, divers exercised for the first 40 minutes on the bottom and for 20 minutes immediately before decompression. The exercise consisted of 5 alternating arm-curls with 10-lb weights, one group every 5 minutes. Divers used the MBS 2000 closed-circuit Hyperbaric Oxygen Treatment Pack (HOTP) system 3 to support oxygen breathing requirements of the decompressions. After every 60 minutes of oxygen breathing on the system, they breathed chamber air for a 15-minute air break. The MBS 2000 HOTP systems had been fitted with sampling ports on the inspiratory side, and oxygen fraction was monitored using a mass spectrometer (EXTREL, Pittsburgh PA). When oxygen fraction fell below about 85%, divers were instructed to purge the system with oxygen. The C02 absorbent canisters were packed with 408 mesh Sofnolime, (Molecular Products, Thaxed, Essex, UK), each with 1.750 + 0.02 1

kg (3.85 + 0.044 Ibs). Carbon dioxide fractions in inspired gas also were monitored, but no interventions were needed. The dive profiles are summarized in Table 1, and the approximate Unit Pulmonary Toxic Dose (UPTD) for each profile, calculated using the linear formula 4, is given in Table 2. UPTD calculations do not account for recovery between dives. The dive profiles are numbered in order of increasing total dive time. In order of depth first and bottom time second, profiles 3 and 6 went to 30 fsw, profiles 1, 4, and 7 to 40 fsw, and 2, 5, and 8 to 60 fsw. However, in order of increasing UPTD, the sequence is profile 3, 1, 6, 4, 7, 2, 5, and 8. Table 1: Dive profiles for disabled submarine rescue simulation Profile # Depth Bottom Total Total Total Profile # Depth Bottom Total Total Total (fsw) Time Stop Time Time (fsw) Time Stop Time Time (min) Time Dive Profile (min) Time Profile (min) (min) (min) (min) (min) 1 40 180 52 238 5 60 240 172 420 0 127 0 66 40 180 99 285 650 60 240 195 443 929 260 180 122 308 6 30 360 90 462 0 56 0 269 60 180 169 355 719 30 360 102 474 1205 3 30 240 43 291 7 40 360 131 503 0 196 0 228 30 240 82 330 817 40 360 159 531 1303 440 240 94 342 8 60 360 232 604 0 145 0 126 40 240 103 351 838 60 360 251 623 1353 Decompression to the first stop and between stops was at 30 fsw/min. Table 2: Oxygen exposures (UP TD for decompression Profile UPTD n Profile UPTD n 1 254 16 5 806 16 2 631 15 6 261 8 3 177 16 7 460 16 4 338 14 8 1068 16 n = the number of subjects for whom pulmonary function was measured after surfacing. 2

EXPERIMENTAL DESIGN AND ANALYSIS The subjects performed pulmonary function tests one to five days before the test dives (baseline), immediately before diving, within 90 minutes of leaving the chamber after the second dive, and on the second or fourth day after the test dives. Each pulmonary function measurement session involved three successful repeats of each test, according to the American Thoracic Society standards. 5 The average values from the three trials were used in all further analysis. We studied forced vital capacity (FVC), forced expired volume in one second (FEVI), and diffusing capacity (DLCO) corrected for hemoglobin concentration. Flow volume loops were measured on each occasion, and diffusing capacity was measured at baseline and at the later post-dive session. The baseline average values were used to assess changes in diffusing capacity, and the averages of baseline and immediate pre-dive measurements were used to assess changes in flow-volume loop parameters. In the NEDU population, 95% confidence limits have been found to be ±7.7% on FVC, ±8.4% on FEV 1, and ±14.2% on DLCO. 6 A post-dive pulmonary function measurement was considered to be depressed if it fell below these limits. Any pulmonary function test that showed a value significantly depressed at the second pulmonary function measurement was repeated approximately one week after the dive. Divers were questioned about specific symptoms (Table 3) at air breaks, between dives, and at each pulmonary function measurement session. Table 3: Symptoms list During the dives: Vision changes Ringing or roaring in ears Nausea Tingling or twitching Light-headedness or dizziness Chest tightness Shortness of breath Rapid shallow breathing Burning on inspiration Cough After the dives: Inspiratory burning Cough Chest pain or tightness Shortness of breath Lowered exercise tolerance Unreasonable fatigue 3

EQUIPMENT AND INSTRUMENTATION The Collins CPX and Collins GS Modular Pulmonary Function Testing System instruments (W. R. Collins, Inc.; Braintree, MA) were used to measure pulmonary function. A CO-oximeter (Instrumentation Laboratory; Lexington, MA) determined carboxyhemoglobin and hemoglobin concentrations in venous blood. PULMONARY FUNCTION PROCEDURES Baseline flow volume loops and diffusing capacity were recorded several days before diving. After subjects surfaced from the first dive they were asked about symptoms but pulmonary function was not measured. After they surfaced from the second dive, they were asked again about symptoms and flow volume loops were recorded. At the pulmonary function session two to four days later, flow volume loops and diffusing capacity were measured and divers were asked again about symptoms. To record flow volume loops, a subject wearing nose clips breathed on a mouthpiece into and out of a spirometer. The subject first breathed normally, then inhaled rapidly and as fully as possible before exhaling with maximum force, and then inhaled fully. Measurements of FVC, FEV 1, peak expired flow, and other variables were read from the flow volume loops. The single-breath technique was used to measure DLCO: the subject exhaled as far as possible, inhaled a large breath of test gas from the spirometer, held his breath for 10 seconds, then exhaled rapidly past the analyzer probe. The test gas contained 0.3% carbon monoxide and 0.3% methane, and the variables used to obtain DLCO were calculated from the gas concentrations before and after the breath-hold. Adjustments were made for carboxyhemoglobin and hemoglobin concentrations. 7 Volumes expired before the gas concentrations were measured and the volumes of gas over which the concentrations were averaged were adjusted to ensure that the analyzer signal was stable when measurements were recorded. 8 Non-respiratory symptoms RESULTS Four divers reported nausea during decompression, three during profile 8 after breathing oxygen at 50 fsw (1068 UPTD) and one during profile 7 (460 UPTD) after 44 minutes of oxygen at 30 fsw and about 15 minutes of oxygen at 20 fsw. Three subjects, one of whom had been nauseated, reported fatigue, low exercise tolerance, and/or difficulty sleeping after profile 8. One subject reported unreasonable fatigue after profile 3 (177 UPTD), and one reported low exercise 4

tolerance after profile 5 (806 UPTD), while one subject, not the one who was nauseated, reported low exercise tolerance and difficulty sleeping after profile 7. Pulmonary effects Although pulmonary symptoms were reported after 24 man-dives, most were mild. Moderate to severe symptoms were reported after profile 2 (UPTD = 631), profile 5 (UPTD = 806) and profile 8 (UPTD = 1068), some with and some without changes in pulmonary function. Symptoms sometimes persisted for several days (Fig.1), often after associated changes in pulmonary function had resolved. All symptoms had cleared by one week after diving. # Divers 10 Pulmonary Symptoms 6 2 0- Surfacing -LO 2 days post co co CD CO Figure 1: Pulmonary symptoms as a function of UPTD. Symptom grading: Yellow = mild, orange = moderate, and red - moderately severe to severe. Flow-volume loops after surfacing were recorded for 115 subject dives. At least one parameter was significantly below baseline in 34 of the recordings. However, after two to four days, only five of the 122 subjects measured showed depressed pulmonary function parameters, and by one week after diving all divers had recovered. Changes for all subjects are shown in Figures 2-6. Although greater oxygen dose (UPTD) was associated loosely with more reduction in flow-volume parameters on surfacing, many divers experienced no significant changes, and some had increases in measured pulmonary variables. 5

Diffusing capacity, measured only at the later session, was within normal limits of baseline for all measurements. Late deficits in pulmonary function did not appear to be associated with UPTD. The most severe reductions recorded after surfacing were 16.4% in vital capacity after profile 8, with mild symptoms; 17.8% in FEVy and -29.6% in mid-expiratory flow after profile 5, with mild inspiratory burning; and -26.1% in peak expiratory flow with mild symptoms after profile 8. A notable change in pulmonary function was found after profile 1, also, when mid-expiratory flow from one diver was reduced by 31% from the baseline and pre-dive values, accompanied by mild chest tightness. Later %Changes in FVC 23.1 23.1 %Changes in FVC on surfacing 7.7 cc 7.7 M -7.o 7.7-23.1 - -23.1 0 500 1000 1500 0 500 1000 1500 Figure 2: Forced vital capacity changes from the average of baseline and immediate predive measurements. The scale has been chosen in bands of 95% confidence interval. The 95% confidence interval around baseline is ±7.7%. Later %Changes in FEV 1.%Changes in FEV 1 on surfacing 25.2 25.2- =-IIi i l... I.'=r l ll' I I 8.4 * 8.4 84-8.4 1 i -25.2-25.2 0 500 1000 1500 0 500 1000 1500 i Figure 3: FEV, changes from the average of baseline and immediate predive measurements. The 95% confidence interval is ±8.4%. I 6

Later %Changes in Peak Flow 50.4 50.4 - %Changes in peak flow on surfacing 16.8 16.8-16.8 16 8-50.4-50.4 0 500 1000 1500 0 500 1000 1500 Figure 4: Peak expiratory flow changes from the averages of baseline and immediate pre-dive measurements. The 95% confidence interval for peak expiratory flow is ±16.8%. 51.9 Later % Changes in Mid-expiratory Flow % Changes in 51.9 -Mid-expiratory Flow on surfacing -773-173 -' -i- I -51.9 1-51.9 0 500 1000 1500 0 500 1000 1500 Figure 5: Mid-expiratory flow (25% to 75% of forced expired volume) changes from the averages of baseline and immediate pre-dive measurements. The 95% confidence interval for peak expiratory flow is ±17.3%. 7

Later % Changes in DLCO 28.4...... ' 14.2 0.0 S-14.2-28.4 0 500 1000 1500 Figure 6: Diffusing capacity changes from baseline measurements. Diffusing capacity was measured only at baseline and two to four days after surfacing. The 95% confidence limits are ±14.2%. DISCUSSION AND CONCLUSIONS The nausea reported during decompression may have been caused by oxygen exposure, but also could have resulted from prolonged breathing of air warmed by passage through the MBS 2000 scrubber unit. However, recorded inspiratory gas temperatures rarely exceeded 3 52C. The fatigue and difficulty sleeping also may have been related to CNS oxygen toxicity, but may just as well have been caused by the disruption of diurnal rhythms caused by the long profiles plus preand postdive testing - even the relatively-short profile 3 was 13 hours long, and profiles 7 and 8 were longer than 20 hours. The highest oxygen exposures - longest and deepest - in the short term caused significant pulmonary distress in a number of divers. However, divers were not incapacitated and they recovered quickly. From the standpoint of oxygen toxicity, these profiles are acceptable for the emergency use for which they were developed. 8

REFERENCES 1. Naval Sea Systems Command letter, NAVSEA OOC Task Assignment 01-10: Submarine Rescue Decompression and Tender Management, 10560/TA 01-10 Ser 00C32/3035 of 14 Feb 01 2. W.A. Gerth. Oxygen-Accelerated Decompression of Submarine Rescue and Diving Recompression System (SRDRS) Operators and Tenders. NEDU Technical Report 05-04, Navy Experimental Diving Unit, Panama City, FL, 2005. 3. D.D. White, D.M. Fothergill, D. Warkander, and C. Lundgren. Submarine Rescue System - Hyperbaric Oxygen Treatment Pack. NSMRL Report 1215, 2000. 4. A.L. Harabin, L.D. Homer, P.K. Weathersby, and E.T. Flynn. An analysis of decrements in vital capacity as an index of pulmonary oxygen toxicity. J. Appl. Physiol. 63(3): 1130-1135, 1987. 5. American Thoracic Society, "Standardization of Spirometry 1994 Update," American Journal of Respiratory and Critical Care Medicine, Vol. 152 (1995), pp. 1107-1136. 6. B.E. Shykoff, Pulmonary Effects of Submerged Breathing of Air or Oxygen, NEDU TR 02-14, Navy Experimental Diving Unit, Nov 2002. 7. Instruction Manual for the Collins Comprehensive Pulmonary Laboratory (CPL) (Braintree, MA: Collins Medical, 2000). 8. B.E. Shykoff, Measurement of Diffusing Capacity for Carbon Monoxide (DLCO), NEDU TR 02-04, Navy Experimental Diving Unit, May 2002. 9